Вы находитесь на странице: 1из 3

HELP  847-549-7600 REQUEST A QUOTE ORDER STATUS  MY ACCOUNT SIGN IN

Enter Keyword, Item #, or Part #  QUICK ORDER  CART 0

PRODUCTS INDUSTRIES BRANDS SERVICES PRODUCT SUPPORT

Save up to 77% on select Spectrum chemicals through October 31!

 EMAIL US  SHARE  PRINT

Shimadzu UV-1800 UV/Visible Scanning Spectrophotometer; 115


VAC
Shimadzu– Mfr # 220-92961-01 – Item # EW-83400-20

Write a Review

Powerful 1-nm resolution in a compact double-beam


instrument $12,500.00 USD / EACH


Extremely versatile with full functionality from 190 to
1100 nm 1 ADD TO CART


Control as a stand-alone unit or through a PC with
+ADD TO LIST
included UVProbe software

 
PC interface and ash-drive data transfer via USB
Usually Ships in 5 Days
connectivity

Built-in validation software ensures operational
Representative image only.
accuracy

MORE +
ADD TO COMPARE

SPECS & DESCRIPTION REVIEWS Q&A CUSTOMER SUPPORT

Speci cations & Description


Stray Light <0.02%T at 340 nm, 400 nm; <1.0%T at
198 nm INCLUDES
Source Lamp Deuterium; Tungsten-Halogen USB interface cable, UV Probe software, and power cable with US plug.

Source Lamp Life 2000 hours


MORE ABOUT THIS ITEM
Beam Type Double The UV-1800 is an advanced high-resolution spectrophotometer utilizing a precision
Czerny-Turner optical system. Operation can be either as a stand-alone instrument or
Bandwidth 1.0 nm
as a PC-controlled instrument with the included UV Probe software. USB memory can
Min Wavelength (nm) 190 be connected directly to the UV-1800 for simple data transfer and printing is possible
with the optional screen-copy printer or printers that support PCL control codes.
Max Wavelength (nm) 1100 Photometric Mode measures the absorbance or transmittance at a single wavelength
or at multiple (up to eight) wavelengths. In multiple-wavelength measurement,
Wavelength Accuracy ±0.1 nm
calculations can be performed on the data obtained for up to four wavelengths,
Wavelength Reproducibility ±0.1 nm including the calculation of the difference between, or ratio of, the measurements
obtained for two wavelengths.
Min Photometric - Transmittance (%T) 0 Spectrum Mode obtains sample spectra using wavelength scanning. Changes in the
sample can be tracked using repeated scans. Data processing operations, such as the
Max Photometric - Transmittance (%T) 400
enlargement or reduction of the spectra obtained, peak detection, and area
Min Photometric - Absorbance (A) -4 calculations, are also possible.
Quantitation Mode generates a calibration curve from standard samples, and uses it to
Max Photometric - Absorbance (A) 4 calculate the concentrations of unknown samples. Various combinations of
wavelengths (1 to 3 wavelengths and derivatives) and calibration curves (K-factor and
Photometric Drift <0.0003 A/hr rst-to-third order regression calibration curves) are possible.
Kinetics Mode measures the change in absorbance as a function of time, and calculates
Detector Silicon photodiode
enzymatic activity values. You can select either the kinetics measurement method or
Output USB the rate measurement method.
Time-Scan Mode measures the change in absorbance, transmittance, or energy as a
Display Type LCD (4.75" x 3.5") function of time.
Multi-Component Quantitation Mode separately quantitates up to eight components
Width (cm) 45
mixed in a single sample. Pure components or mixtures of components can be used as
Height (cm) 49 standard samples.
Biomethod Mode is capable of analyzing DNA and proteins using the several common
Depth (cm) 26 quantitation methods including quantitation of DNA or protein using the absorbance
at 260/230 nm or 260/280 nm and protein quantitation via the Lowry method, BCA
Width (in) 17 45/64
method, CBB method, Biuret method, and UV absorption method (direct measurement
Height (in) 19 19/64 at 280 nm).
Security and validation functionality are also preprogrammed. Security functions allow
Depth (in) 10 1/5 you to restrict functions according to three user levels: administrator, developer, and
operator. Automatic or semiautomatic validation functions include wavelength
Power (Hz) 60 accuracy, wavelength repeatability, resolution, stray light, photometric accuracy,
photometric repeatability, baseline atness, baseline stability, and noise level. The
Description UV/Visible Scanning
Spectrophotometer; 115 VAC operating time of the lamps can be recorded and displayed so that you can anticipate
replacement and avoid downtime.
Available for sale in the United States only
Product may contain trace amounts of mercury; cautions should be used in
breakage, cleanup, shipping and/or disposal.

REVIEW SNAPSHOT® by PowerReviews


Not yet rated. Be the rst to Write a Review

Do you have questions about this product?

Get answers from real customers and in-house experts with AnswerBox.

4 Questions | 4 Answers

Displaying questions 1-4

Q: what is the price of 1800 UV Spectrophotometer and 2600-2700 uv spectrophotometer in india

Asked on 6/10/2016 by neelam from gurgaon,delhi-ncr

1 answer

STAFF EXPERT

A: Please contact our India branch directly for all formal quotes. We are represented in India by:

Cole-Parmer India

403 A-Wing, Delphi

Hiranandani Business Park, Powai

Mumbai 400 076, India

Phone: +91-22-61394444 (Board)

Fax: +91-22-61394422

Email: info@coleparmer.in
Website: wwww.coleparmer.in
Answered on 6/13/2016 by Anthony from Technical Support

Q: I am Dr. Satyendra Prasad, Asst Professor at Nagpur University. I would like to have quotations for double beam UV spectrophotometer

Asked on 10/19/2015 by sattu from Nagpur, Maharashtra, India

1 answer

STAFF EXPERT

A: Please contact our India branch directly for all formal quotes. We are represented in India by:

Cole-Parmer India

403 A-Wing, Delphi

Hiranandani Business Park, Powai

Mumbai 400 076, India

Phone: +91-22-61394444 (Board)

Fax: +91-22-61394422

Email: info@coleparmer.in
Website: wwww.coleparmer.in
Answered on 10/19/2015 by Danielle from Technical Support

Q: how the procedure if we want buy this one?

Asked on 5/31/2015 by harry from west java

1 answer

STAFF EXPERT

A: There are different operational procedures based on the mode that you choose to use. There are many modes, which are: Photometric mode, Spectrum mode,
Quantitation mode Kinetics mode, Time Scan mode Multi component mode, Bio-method mode, Utilities mode, Maintenance, and PC control.
Answered on 6/1/2015 by Danielle from Technical Support

Q: Price in india? need for research project.

Asked on 10/17/2014 by varsha from bareilly, india

1 answer

STAFF EXPERT

A: You can contact Cole Parmer India for pricing at info@coleparmer.in or by phone at 91-22-6716-2222.

Answered on 10/17/2014 by Danielle from Technical Support

Displaying questions 1-4

Do you have a question about this product?

NEED HELP WITH THIS PRODUCT?


CALL US AT
Our specialists are here to help you nd the best product or part OR
available for your application. Call or Chat Online with us and we 847-549-7600  EMAIL US
will make sure you get the right product or part for the job.

You Might Also Like...

Oakton Buffer pack, 500 mL InnoCal NIST-Traceable Gast High-Capacity Vacuum C-Flex Tubing, Opaque
each of 4.01, 7.00, and 10.00 Calibration; Thermocouple Pump DOA-P704-AA White 1/8"ID x 1/4"OD, 25
buffer Thermometer System (Met… SI-07061-40 ft/pack
SI-05942-10 SI-17002-10 SI-06424-67

$37.00 USD / PKG OF 3 $198.00 USD / EACH $642.00 USD / EACH $37.50 USD / PKG OF 1

Connect With Us Enter your email address SIGN UP

Sign up to receive the latest in industry news, products, & services.

COMPANY INFO ORDER SUPPORT CUSTOMER SUPPORT


      About Us Request a Quote Contact Us
Quality Policy Order Status Locate a Dealer
Careers Returns & Cancellations Catalog Request
Testimonials Shipping Policy Virtual Catalog
Equal Employment Opportunity Warranty Policy Site Support
Business Pro le Terms & Conditions FAQs

Meeting the needs of the Press Releases


Event Calendar
scienti c and engineering
Greener Business
communities since 1955.

Cole-Parmer | 625 Bunker Court Vernon Hills , IL 60061 United States


Telephone: 847-549-7600 , 847-549-7600 | Fax: 847-549-1700 | Email: export@coleparmer.com

© 2017 Cole-Parmer Instrument Company, LLC. All Rights Reserved. TERMS OF USE PRIVACY POLICY SITE MAP
OTHER SITE MAPS

Вам также может понравиться