Вы находитесь на странице: 1из 121

Dear Valued Customer,

Congratulations on acquiring the new Accura Edger. We appreciate and thank


you for the confidence you have entrusted in our name.

This Edger has been manufactured with the greatest of care and inspected to
meet the most rigorous Briot standards. We recommend you read this manual,
carefully, for the proper use and enhancement of the life of your new equipment.
Please, keep it in a safe place for future reference.

As with all mechanical and electronic devices, however, your Briot machine will
require periodic adjustments, routine maintenance, and eventually the
replacement of certain hard-working parts. To ensure that your Briot unit is
continually operating at peak efficiency, it will be beneficial to have your unit
periodically inspected by an authorised Briot service representative.

Once again, thank you for choosing Briot.

The information contained in this manual are not contractual and can be
modified without notice. On top of that, errors and omissions can occur,
although all is performed to avoid them.
Briot does not assume any responsibilities or liabilities for damages
caused by errors or omissions.

BRIOT INTERNATIONAL
2, rue Roger Bonnet - BP 8
27340 PONT DE L'ARCHE
FRANCE

Tel. : (33) 02 32 98 91 32
Fax : (33) 02 35 02 02 94
Table of Contents

Issue: July 2003


Reference: FC 00 456-02
Accura Cx & Pro

Table of Contents

1 Installation/Preparation
Main Controls and Components.....................................................................................1-3
Unpacking Machine......................................................................................................1-4
Safety Precautions.......................................................................................................1-7
Installing the Machine...................................................................................................1-8
2 System Introduction
Keypad .......................................................................................................................2-3
Scanform™ Scanner ....................................................................................................2-6
Basic Concepts ...........................................................................................................2-7
3 Scanning
Scanning Mode............................................................................................................3-3
Frame Shape Scanning ................................................................................................3-5
Pattern or Demonstration Lens Shape Scanning .............................................................3-7
4 Layout/Blocking
Layout/Blocking Mode..................................................................................................4-3
Layout and Blocking the Lens .......................................................................................4-5
5 Edging
Edging Mode ...............................................................................................................5-3
Edging a Lens .............................................................................................................5-6
Controlled Bevel......................................................................................................... 5-10
Controlled Groove....................................................................................................... 5-13
Retouching a Lens ..................................................................................................... 5-15
6 System Adjustments
Edging Wheel Differential Adjustment ............................................................................6-3
Frame Correction Adjustment........................................................................................6-4
User's Language Selection............................................................................................6-5
Using Level Selection ...................................................................................................6-6
Enable/Disable the Aestheticism Control........................................................................6-7
Enable/Disable the Retouch control ...............................................................................6-8
Screen Contrast Adjustment .........................................................................................6-9
Scanform Set-up........................................................................................................ 6-10
Wheel Dressing ......................................................................................................... 6-18
Size Adjustment (reset sizes)..................................................................................... 6-19
Wheel Counters Consultation...................................................................................... 6-20
Adjusting the Scanform Unit........................................................................................ 6-23
Lens Feelers Adjustment ............................................................................................ 6-28
7 System Cleaning
Cleaning the Edger.......................................................................................................7-3
8 Maintenance
Scanform messages ....................................................................................................8-3
Edger messages..........................................................................................................8-5

Table of Contents iii


Accura Cx & Pro

Table of Contents (continued)

Appendix A Installing a Recirculating System


Installing a Recirculating System.................................................................................. A-3
Cleaning the Pump Recirculating System...................................................................... A-4
Appendix B Functioning with Memory Board & Network Connection
Bar Code Reader ........................................................................................................ B-3
Memory Extension Circuit Board .................................................................................. B-4
Communication Extension Circuit Board ....................................................................... B-9
Appendix C Specifications
Specifications: Accura Cx & Pro .................................................................................. C-3
Specifications: Accura Cx............................................................................................ C-5
Specifications: Accura Pro........................................................................................... C-6

iv Table of Contents
Accura Cx & Pro

Evolution in relation to the previous version

This manual brings you the following information regarding the V3.70 and V3.71 Accura programs.

Page(s) New releases / Modification

2-3
key

2-4
key

2-6
key

5-5
Hydrophobic (water repellent) lenses

5-6 Warning: risk of collision of the adapter with the wheels

5-8 Safety mode

5-12, 5-14,
Hold the key to clamp
5-15

8-7 to 8-10 New messages

Table of Contents v
1 Installation/Preparation
Accura Cx & Pro

Main Controls and Components

Diagram

Edging Station Layout/Blocking Device

Scanform™

Installation/Preparation 1-3
Accura Cx & Pro

Unpacking Machine

Warning

If you proceed to install your edger yourself, please do not discard boxes or any of its
packing contents.

Procedure

Follow the steps below to unpack your edger unit.

Step Action Diagram

1 Remove the nose piece from the wedge inserted into the
scanform.
Nose
piece

2 Pull up carefully the scanform wedge.

3 Insert the centring nose piece into the scanform.

4 Remove the edger cover guard, by using the key


contained in accessory box.

1-4 Installation/Preparation
Accura Cx & Pro

Unpacking Machine (continued)

Procedure (continued)

Step Action Diagram

5 Unscrew and remove the Allen screw from the


carriage shipping flange.

6 Remove the carriage flange. -

7 Remove the wedge located between the chassis


and the carriage.

8 Remove the wedge of the lifting jack head.

9 Loosen and remove the nut and the two washers of


the threaded rod coming from the left of lifting jack.

10 Remove the lifting jack wedge and its rod inserted


in the translation tube.

Installation/Preparation 1-5
Accura Cx & Pro

Unpacking Machine (continued)

Procedure (continued)

Step Action Diagram

11 Remove the wedge located between the safety-


bevel motor and the edging chamber.

12 Remove the stopper located at the rear of the


machine in order to get access to the concerned Opening in
the rear cover
screw.

13 Bring the carriage on the extreme left side


2mm Allen
(Operator located behind the machine). Wrench

14 Check the set screw of the gear A is lined up with Gear A


the hole. If not, turn the gear in order to get to this
situation. Stopper

Important: Before tightening the screw, the 1 &


2 marks on the small gear and 3&4
on the large gear must be lined up
(make several turns if needed).

15 Put a 2-mm Allen wrench into the screw.

16 Tighten the screw strong.

17 Put back the edger cover guard, by using the key


contained in accessory box.

1-6 Installation/Preparation
Accura Cx & Pro

Safety Precautions

Warning

1 For the Accura Pro, before any operation on the machine (installation or servicing), check that
main power switch is off and power plugs are both (Accura and inverter) not inserted in wall
socket.
2. Do not place the edger near or on top of a source of energy (radiator or heater).
3. Make sure your voltage source corresponds to the voltage specified on edger nameplate,
located on the rear of the machine.
4. If the machine is not going to be used for a long period of time you should unplug the power
cords from the wall outlet.

• The external inverter for use with the Accura must be the Listed Telemecanique
Inverter, model ATV18U29M2 or Leroy Somer, model SE 2.5M/TL BRE.

• The inverter is delivered complete, with cables, plugs, strain relieves, correct
configuration and tested by the manufacturer.
• Please note that no field servicing is permitted for this unit.

Briot does not assume any responsibilities or liabilities for damages caused by
negligence or ignoring the safety precautions enlisted in this manual.

Installation/Preparation 1-7
Accura Cx & Pro

Installing the Machine

Installation Conditions

Before installing the machine, make sure the bench is made up of the following components:

1. The bench
The bench receiving the machine must steady and leveled and be made up of a foot print of about
800 x 700 mm.

2. The electricity
• Accura Cx: 1 power outlet: 2P+T - 16 A - 220 V or 110 V protected with differential breaker of
30 mA. The outlet must be connected to the EARTH.
• Accura Pro: 2 power outlets: 2P+T - 16 A - 200 V–240 V protected with differential breaker of
30 mA. The outlets must be connected to the EARTH.

3. The water
• A water supply with a stop faucet equipped of a male connector 20x27 mm.
This faucet must be kept for the machine and drilled at 80 cm maximum from the place
excepted for the machine. The access must be easy and the faucet must be turn off when
the machine is not used.

For a well functioning of the machine, the maximum water supply pressure must be
between 4 and 7 bar.

• A water draining of ∅ 80 mm or higher. For proper drainage slope, angle pitch should be at
least 5 %.
• For machine type Polycarbonate, provide a place under the machine with a minimum of
600w x 510h x 460d mm to place the water container.
4. The pump

Briot supplies pump system especially made for required water supply to Accura and for filtering
of the edging waste. The pump dimensions are as follows:
• Dimensions:
• Width: 600 mm (24”)
• Depth: 400 mm (16”)
• Height: 800 mm (32”).

1-8 Installation/Preparation
Accura Cx & Pro

Installing the Machine (continued)

Bench Preparation

Follow the steps below to prepare the bench.

Step Action

1 Drill the bench as follows.

∅ 120 mm
270 mm
598 mm
Bench

305 mm
Edger

660 mm

2 Drill the drain water hole(s).

3 Place the edger on the bench by positioning it in relation to the drilled holes.

Installation

Follow the steps below to install the machine.

Step Action Diagram

1 Level the machine by screwing or unscrewing the four


feet.

2 Plug the drain pipe to the chassis of the machine.

Installation/Preparation 1-9
Accura Cx & Pro

Installing the Machine (continued)

Installation (continued)

Step Action Diagram

3 Connect the drain pipe(s) to the machine and to the


faucet or the pump. Please refers to Appendix A for
pump installation important notice.

Note: In case of installation on direct water only,


add a filter joint contained in the accessory
box.

4 Check that the main switch of the machine is on OFF


position.

5 Connect the machine to the power outlet.

6 For the Accura Pro, connect the inverter as follows:


1. Connect the inverter control cable to the edger.
2. Connect the inverter power cable to the edger. Inverter
Control
3. Fix the plate n° 11 22 165 (2x screws). Cable
4. Fix the cable strain relief to secure the motor
Inverter
cable. Power
Cable

7 For OMA machines, connect the edger to the OMA Bar Code
network and connect the bar code reader. Reader
Connector
OMA Network
Connector

8 Mount the chucks and the centring nose piece -


(scanform) contained in the accessory box.

9 Remove the cover. -

10 Adjust the water flow by starting a cycle without lens. -

1 - 10 Installation/Preparation
Accura Cx & Pro

Installing the Machine (continued)

Installation (continued)

Step Action Diagram

11 Adjust each watering by acting on 1-2 and 3 solenoid


2
valves (see paragraph Adjustments below).

3 1

12 Close the cover and make one or two jobs to check -


the well functioning of the machine.

Adjustments

Types Description

Main Water Spray (1) • Adjustable by operator.


• Must be sufficient to correctly lubricate the edging point.

Visor (2) • Not accessible by operator.


• Must be adjusted while installation.

Cleaning of the back of Must be adjusted as follows:


the edging station • Water spray must be enough to remove the polycarbonate dust
(Polycarbonate) (3) that hit the back of edging station (near the feelers).
• Water spray must not be too high to avoid a mist creation that can
moisten the TP roughing wheel and create an undesired edging “in
ribbon” of polycarbonate.

Installation/Preparation 1 - 11
Accura Cx & Pro

Installing the Machine (continued)

Installation of the bench

Pro Cx & Pro


Speed
Inverter
Accura

> 1,3 m

1 - 12 Installation/Preparation
2 System Introduction
Accura Cx & Pro

Keypad

Keys: Diagram

N° 000000000008

METAL

+70.38

Keys: Description

The following table describes each key of the keypad.

Key Function/description

Enters numerical values.

Confirms the numerical value entered.

Decrements the selected numerical value.

Increments the selected numerical value.

Moves the lens left during roughing and/or rimless.

Moves the lens right during roughing and/or rimless.

Releases and clamp the lens. (Press and hold the key to clamp.)

Note: This key exists also to the left of the edging station, for left-handed people.

System Introduction 2-3


Accura Cx & Pro

Keypad (continued)

Keys: Description (continued)

Key Function/description

Open the visor (inactive during edging cycle)

Corrects error while in entry process.

In combination with the following key:


• Consults wheel counters.

• Accesses to optician adjustment screens.

• Increases the screen contrast.

• Optician Size Adjustment equipped with digital calliper rule


(accuracy: 1/100mm).
• Decreases the screen contrast.

• Reverses the screen color.

• Gives a positive sign to a data input.

• Gives a negative sign to a data input.

Validates a function.

Does an emergency stop.

Unmarked key (Fct0 to Fct5), its meaning depends of the parameter displayed to
the left of this key.

Unmarked key (Fct6 to Fct9), its meaning depends of the parameter displayed
facing this key.

2-4 System Introduction


Accura Cx & Pro

Keypad (continued)

Initialisation Screen

On turning the machine starts and reads the following screen while the initialization cycle is running.

ACCURA CX

V01.00 # 0108 V01.00 V01.00

System Introduction 2-5


Accura Cx & Pro

Scanform™ Scanner

Keyboard: Diagram

Keyboard: Description

The following table describes each key of the integrated scanform™ keyboard.

Key Description

Releasing and clamping the lens. (Press and hold the key to clamp.)

Note: Key established on this keyboard to be more accessible by left-handed


people.

Setting and adjusting use only.

Setting and adjusting use only.

Setting and adjusting use only.

ON Displays the message ON during regular operation. Setting and adjusting use only.

Interruption of Frame Shape Scanning.

Note: This key has a blinking red LED warning that an error has been detected on
the scanform™.

Scanning Frame Shape.

Note: This key is linked with a green LED allowing to attract your attention to the
necessity to press on this key to execute the shape scanning cycle.

2-6 System Introduction


Accura Cx & Pro

Basic Concepts

Three Working Modes

The edger makes three basic operations corresponding to a screen called "mode" that you can
identify by a symbol located on right side of the screen.

Mode Screen Functions

Scanning N° 000000000008 Allows to enter the following parameters:


(Blue • Job Number
METAL
background)
• Frame Type
• Lens Side to Scan
+70.38
• Frame PD or Bridge
• Symmetry
• Scanning Type

Layout/ Allows to enter the following parameters:


N° 000000000008
Blocking ∅
∅ 45 Π
Π
• Lens Side for Layout
(Green
background) • Vision Type
• Horizontal Decentration
+62.00 • Height Decentration
+28.00 • Segment Width for Near Vision
28 • Layout/Blocking Mode
• Height Reference.

Edging Allows to enter the following parameters:


Π
Π
N° 000000000008
(Ochre • Lens Side to Edge
background)
• Lens Type to Edge
ORGANIC
• Lens Finishing Type
• Bevel/Grooving Type
• Lens Final Size
+00.00 • Safety-Bevelings
• Edging Pressure
• Lens Polishing.

System Introduction 2-7


Accura Cx & Pro

Basic Concepts (continued)

Going One Mode to the Other

To go one mode to the other, press the following key until displaying the desired screen.

N° 000000000008
The screens scroll in the following order:
METAL
1. Scanning Screen (blue):

+70.38 2. Layout/Blocking Screen (green):

3. Edging Screen (ochre)

Current Job/Previous Job

• If your machine is not equipped with a memory extension circuit board, the buffer can
contain two jobs (First-In/First-Out) being managed as follows.

Type Diagram Managing

Current
Job:
N° 000000000008
Key:
Job Number METAL
• Access to the previous job, in the three
in Inverse modes.
Video
+70.38

Key:
• Creation of a new job and deletion of
the previous job, in scanning mode.
• Inactive, in layout and edging modes.

Previous N° 000000000008

Job: Key:
OPTYL
Job Number • Inactive, in the three modes.
in Normal
Video +66.20
Key:

• Access to the current job, in the three


modes.

• If your machine is equipped with a memory extension circuit board, see Appendix B
Functioning with Memory Board & Scannet Network Connection to manage the memory.

2-8 System Introduction


3 Scanning
Accura Cx & Pro

Scanning Mode

Function/Diagram

N° 000000000008
Fct0
METAL Fct1
Fct2
+70.38 Fct3
Fct4
Fct5

Functions: Description

The following table describes each scanning screen function of the Accura.

Function Selection Description

Fct0 Scanning mode

Fct1 Metallic frame


METAL

PLASTIC Plastic frame

OPTYL Optyl frame

PATTERN Pattern or demonstration lens scanning

Fct2 Frame Scanning right side

Frame Scanning left side

Frame Scanning both sides

Scanning 3-3
Accura Cx & Pro

Scanning Mode (continued)

Functions: Description (continued)

Function Selection Description

Fct3 Distance between centers (DBC)


+70.40

Fct4 Symmetry

No symmetry

Fct5 Automatic scanning

Manual scanning: Manual Stylus Positioning in the groove – Slow


scanning

3-4 Scanning
Accura Cx & Pro

Frame Shape Scanning

Procedure
Follow the steps below to scan the frame shape.

Step Action

1 Create a job number. To do this, press the key or enter a job number aid of the

keypad and press the key.


Note:
• If your machine is not equipped with a memory or communication extension
circuit board, see paragraph Current Job/Previous Job of the Basic Concepts
procedure in Chapter 2
• If your machine is equipped with a memory or communication extension
circuit board, see Functioning with Memory Board & Scannet Network Connection in
Appendix B.
2 Select the frame type: metallic, plastic or Optyl.

3 Select the side(s) to scan: right, left or both sides.

4 If necessary, select symmetry function.

5 Select the scanning type: Auto or Manual.

6 Press the key to validate the parameters.

7 Before scanning, clean the frame with an ultrasonic cleaning device.

8 Put the frame into the frame holder of the scanform™.

Check the eyewire joint is well closed (tighten the joint


screw).

Scanning 3-5
Accura Cx & Pro

Frame Shape Scanning (continued)

Procedure (continued)

Step Action

9
Press the key of the scanform™ to scan the frame.

Result: When the scanning is finished, the shape is drawing on the screen.
N° 000000000008

METAL

+70.38

Scanning Interruption

In case of problems, you can stop the shape scanning cycle at anytime.

Step Action

1
Press the key of the scanform™.

Result: The scanning is stopped and the following message comes up.
N° 000000000008

METAL

+70.38

*****WARNING***** *****WARNING*****
Origin : Scanform EO01
Type : Tracing aborted
Ok

Fct8

2 Press the Fct8 key.

Result: The message disappears from the screen.

Note: You can resume the scanning again. See previous procedure.

3-6 Scanning
Accura Cx & Pro

Pattern or Demonstration Lens Shape Scanning

Procedure

Follow the steps below to scan the pattern or demonstration lens shape.

Step Action

1 Create a job number. To do this, press the key or enter a job number aid of the

keypad and press the key.


Note:
• If your machine is not equipped with a memory or communication extension
circuit board, see paragraph Current Job/Previous Job of the Basic Concepts
procedure in Chapter 2
• If your machine is equipped with a memory or communication extension
circuit board, see Functioning with Memory Board & Scannet Network Connection in
Appendix B.
2 Select the PATTERN frame type.

3 Select the side to scan. To do this, follow the steps below.

If you scan… Then…

Left side 1. Press the key.


2. Insert the pattern placing the nasal part to
the right or insert the right demonstration
lens onto the pattern holder.

Pattern
holder

Scanning 3-7
Accura Cx & Pro

Pattern or Demonstration Lens Shape Scanning (continued)

Procedure (continued)

Step Action

3 Right 1. Press the key.


(conti-
nued) 3. Insert the pattern placing the nasal part to the
left or insert the left demonstration lens onto
the pattern holder.

Pattern
holder

4 Select the symmetry function.

5 Select the scanning type: Auto or Manual.

6 • Place the lower part of the pattern


holder in order to push away the
nose of the pattern holder and to
insert the lower pins between of the
scanform clips.
• Make the top of the pattern holder
rest on the upper jaw of the
scanform in the positioning lugs.

7 N° 000000000008

Press the key of the scanform™


PATTERN

to start the scanning cycle.

Result: The frame scanning is in +00.00

progress and the value of the


bridge value is equal to
zero.

8 Enter a bridge value or a frame distance value.

Note: The machine interprets automatically the entered value as bridge or frame
distance.

9 Remove the pattern holder.

3-8 Scanning
4 Layout/Blocking
Accura Cx & Pro

Layout/Blocking Mode

Function/Diagram

N° 000000000008

∅ 45 Π
Π Fct0
Fct1
Fct2
+62.00 Fct3
+23.00 Fct4
28
Fct5

Fct6
Fct7

Functions: Description

The following table describes each layout/blocking function of the Accura.

Function Selection Description

Fct0 Layout/Blocking Mode

Fct1 Layout/Blocking of the right side

Layout/Blocking of the left side

Fct2 Single Vision Lens Layout

Near Vision Layout (for multifocals)

Layout/Blocking 4-3
Accura Cx & Pro

Layout/Blocking Mode (continued)

Functions: Description (continued)

Function Selection Description

Fct3 Horizontal millimetric decentration


+06.00

Monocular Pupil Distance


+30.00

Binocular Pupil Distance


+62.00

Fct4 Vertical millimetric decentration:


+05.00
A vertical decentration height from the boxing center

BOX height: From the pupil center, to the lowest point of the lens, at
+28.00
the bottom of the frame

MIX height: The height is measured from where the pupil vertically
+25.00
aligns to the edge of the lens at the lower half of the frame

Fct5 Segment width


28

Fct6 Optical center:


Lens is laid out and blocked on the optical center

Geometrical center:
The optical center is displaced from the mechanical center

Fct7 BOX decentration:


Height calculated from the optical center to the extreme bottom point
of the frame

MIX decentration:
Height calculated from the optical center to the frame point at the
vertical of the optical center

4-4 Layout/Blocking
Accura Cx & Pro

Layout and Blocking the Lens

Procedure

Follow the steps below to layout and block the lens.

Step Action

1 Select the right or left lens to layout.

2 Select the vision type (see paragraph Comment & Layout Examples below).

3 Enter the pupil distance of the customer.

Result: The machine interprets automatically the entered value as a total pupil
distance, monocular pupil distance or a decentration.

4 Enter the height of the optical center.

5 If necessary, enter the segment width for bifocals.

6 If necessary, select the centering mode.

7 If necessary, enter the height type.

8 Place a double-sided adhesive tape on a block.

You can use the blocks up to 125 times.


Any use beyond this limit could lead to axis or distance problems whose Briot
refuses all responsibilities.

9 Place the block inside the blocker of the machine.

10 Remove the protective paper from the tape.

11 Place and center the lens to be blocked on the screen


according to the desired layout method (See Comment &
Layout Examples paragraph below).

In case of thin or high cylinder lenses, place the lens


holder ring contained in accessory box between the
screen and the lens to hold and avoid it to break or
move.

12
Press and hold the key to block the lens.

Layout/Blocking 4-5
Accura Cx & Pro

Layout and Blocking the Lens (continued)

Comment & Layout Examples

In case of doubt regarding the lens size for cut out, you can:
• Visually inspect the lens shape on the screen, under the lens blank to verify the lens
blank is large enough or
• Compare the lens blank side diameter to the diameter value displayed at the top of
the screen.
Example: ∅ 45

Lens Layout/Blocking Diagram

Single Vision: w/Raised Optical Center N° 000000000008



∅ 45 Π
Π

+62.00

+23.00

28

Bifocal: w/28 mm Segment Width N° 000000000008



∅ 45 Π
Π

+62.00

+15.00

28

Progressive: Laid out in Distance Vision N° 000000000008



∅ 45 Π
Π

+62.00

+23.00

28

4-6 Layout/Blocking
5 Edging
Accura Cx & Pro

Edging Mode

Functions: Diagram

N° 000000000008 Fct0
Π
Π

Fct1

ORGANIC Fct2

Fct3

Fct4

+00.00 Fct5

Fct6
Fct8
Fct7 Fct9

Functions: Description

The following table describes each layout/blocking screen function of the Accura.

Function Selection Description

Fct0 Edging Mode

Fct1 Edging of the right side

Edging of the left side

Fct2 Glass lens


MINERAL

ORGANIC Organic lens

HI PLASTIC High index lens - organic (Accura Pro)

POLY Polycarbonate lens

Edging 5-3
Accura Cx & Pro

Edging Mode (continued)

Functions: Description (continued)

Function Selection Description

Fct3 Bevel finishing

Rimless finishing

Grooving Finishing

Warning: Grooving is not allowed on mineral lens.

Fct4 Front Side Bevel:


The bevel is placed on the front side of the lens

1/3-2/3 Bevel:
The bevel is placed at 1/3 of the front face and at 2/3 of the rear face of
the lens

1/2-1/2 Bevel:
The bevel is placed in the center of the lens

Rear Side Bevel:


The bevel is placed on the rear side of the lens

Operator Bevel (Hand Symbol):


The operator (see Controlled Bevel below) places the bevel

Esthetical bevel:
Automatic bevel ; based on a 1/3 – 2/3 bevel, the machine places the
bevel as much as possible to the front surface of the lens. The lens size
is also adapted to the possible frame bending before lens fitting. Lens
circumference and eye wire circumference are equal

Expert bevel:
Automatic bevel ; the machine uses the frame curve to place the bevel
and position it as much as possible to the front surface of the lens.
Lens fitting without frame bending

Expert single groove:


Automatic lens grooving – 0.6mm wide

Expert double groove:


Automatic lens grooving – 1mm wide

5-4 Edging
Accura Cx & Pro

Edging Mode (continued)

Functions: Description (continued)

Function Selection Description

Fct 4 Controlled Grooving:


(continued) Lens grooving controlled by the operator who can change the groove
position or curve (see paragraph Controlled Groove below)

Fct5 Retouch: Lens Final Size


+00.00

Fct6 Safety-bevel: not selected for front side

Safety-bevel on front side

Fct7 Safety-bevel: not selected for rear side

Thin safety-bevel on rear side

Medium safety-bevel on rear side

Thick safety-bevel on rear side

Fct8 Minimum Edging Pressure: Edging Thin Lens for example

Medium Edging Pressure: Edging Medium Lens for example

Maximum Edging Pressure: Edging Thick Lens for example

Edging Pressure for Fragile Lenses: Edging Fragile Lens for example

Hydrophobic lenses: special edging program for hydrophobic ( water


repellent) lenses.

Fct9 Lens Polishing:


Only for Organic Lenses

No Edge Polishing

Edging 5-5
Accura Cx & Pro

Edging a Lens

Procedure

Follow the steps below to edge a lens.

Step Action

1 Call a job aid of the bar code reader or entering manually the number aid of the keypad
and press the key.

Result: The shape appears on the screen with its edging parameters.

2 Place the lens to edge in the edger, already centered and blocked, as follows.
• Press the key to open the visor.

• Press the key (or the one located at left of the edging station) to open the lens
clamping.
• Place the blocked lens into the left side adaptor.
• Press and hold the key (or the one located at left of the edging station) to
close the lens clamp.

3 Adjust the water flow by turning the knob, located under the machine at the center.
Note:
• If using direct water supply, check if the water valve is open.
• If using recirculating system, check if the system is correctly installed.
See Appendix A Installing a Recirculating System.

4 Select the side to edge, using function Fct1 (see paragraph Functions: Description
formerly).

5 If necessary, you can modify the edging parameters (see paragraph Functions:
Description formerly).

6 Risk of collision of the adapter with the wheels.


• Two types of “small” adapters are used on the machine (19mm and 17 mm
height). The use of the 19mm adapters when the 17mm ones are required will
make a collision of the adapter with the wheels!
• Use the 19mm height adapter when the message “Small adapters mounted?”
is displayed.
• Use the 17mm height adapter when the message “Small flat adapters
mounted?” is displayed.

5-6 Edging
Accura Cx & Pro

Edging a Lens (continued)

Procedure (continued)

Step Action

6
(continued)
Press the key to start the edging cycle.
Result: The visor closes automatically and the edging cycle starts in the following
order:

1. Roughing Do not open cover, during edging operation.


2. Tracing Do not touch moving parts inside.

Result: If the uncut lens is too small for the shape, a message appears on the screen.
Go to paragraph Lens Re-feeling below.

7 If you… Then...

The bevel is automatic after roughing and lens


Did not select the function
feeling. Go to step 9 of this procedure.

Go to paragraph Controlled Bevel below.


Selected the function

8 If you… Then...

The bevel is automatic after roughing and lens


Did not select the function
feeling. Go to step 9 of this procedure.

Go to paragraph Controlled Groove below.


Selected the function

3. Finishing
4. Polishing (optional)
5. Safety-beveling (optional).
Result: After the edging cycle is complete, the visor opens automatically

9 Hold the edged lens and press the key of the keypad (or the one located at left of
the edging station) to open the right side chuck.

10 Remove the lens from the left side adaptor. Do not remove the block from the lens
until the lens size has been confirmed with the optical frame.

Edging 5-7
Accura Cx & Pro

Edging a Lens (continued)

Safety mode

For the operator’s safety, some controls and actions have been implemented

Wheel rotation:
• The main motor starts only if the visor is closed

• The door opening key is inactive during the wheels rotation


• Opening manually the visor stops the wheel motor and switches the machine in error “visor
function”

Clamping:

• To clamp the lens you have to hold the key until the clamping shaft gets in contact
with the lens.
• Releasing this key when clamping will automatically open the clamp.

• You have two seconds to release the key when the clamp is in contact with the lens
otherwise the clamp opens back if this delay is over.
• Starting the cycle with the clamp open will generate the warning message “Clamp the lens
before start”

Cycle Interruption

The edging cycle can be interrupted at any time by pressing the key.

Result: The edging cycle stops immediately.

Edging a ½Eye Lens

To edge a ½eye lens you must:


1. Replace the standard chucks by the small chucks (∅ 19mm) located in the accessory box.
2. Proceed to edge as any other normal lens (see paragraph Edging a Lens formerly).

5-8 Edging
Accura Cx & Pro

Edging a Lens (continued)

Lens Re-feeling

Follow the steps below to re-feel a lens.

Step Action

1 When the message Lens too small for shape is displaying, press OK key.

Result: The following screen comes up.

Π
Π

Π
Π 1.48 2.97

4.45

Fct9

2 Press the Fct9 key to re-feel the lens 0.5 mm inside.

Note: You can re-feel the lens up to three times with 0.5 mm inner.

Result: If these three re-feelings are not still enough, the lens is too small, the
machine can not edge it.

3 Start the finishing cycle. To do this, go to step 7 of paragraph Edging a Lens formerly.

Edging 5-9
Accura Cx & Pro

Controlled Bevel

Screen Description

Π
Π

Π
Π 1.48 2.97

4.45

Symbol Description

1 2 Developed curved of the lens edge and the bevel:


1. Back Side of Lens 3. Front Side of Lens
3 4 2. Bevel Apex 4. Position Index

Move the bevel apex towards the back of the lens

Move the bevel apex towards the front of the lens

Pivot the bevel apex towards the back of the lens to current index position
+
Pivot the bevel apex towards the front of the lens to current index position
+
Position Index

Lens profile corresponding to the current index:


1 1.48 2.97 2
1. Bevel Position from Front

3 4.45 2. Bevel Position from Rear


3. Value of the lens thickness

→ Move position index view of the lens clockwise

← Move position index view of the lens counterclockwise


Select the bevel point whose position will be modified (opposite point is
the pivot; it won’t move)
Allow the re-trace of the lens

5 - 10 Edging
Accura Cx & Pro

Controlled Bevel (continued)

Screen Description (continued)

Symbol Description

Allow the selection of the following bevel types:

Front Bevel

Rear Bevel

1/3 2/3 Bevel

1/2 1/2 Bevel

Expert bevel

Base Bevel identical to Frame Base

05 Defined Curve Bevel: modifying value (from 1 to 9) by

and/or keys

3-D Bevel: copies identical bevel as for the frame eye wire

Edging 5 - 11
Accura Cx & Pro

Controlled Bevel (continued)

Procedure

Follow the steps below to control the bevel position after roughing and feeling.

Step Action

1 After roughing and lens feeling cycles:


• Modify the bevel type if necessary, aid of the Fct5 key

Result: The new bevel position is released


• If necessary feel the lens again, aid of the Fct9 key.
Π
Π

Π
Π 1.48 2.97

4.45 Fct5

Fct9

2 Select the bevel point whose the position will be modified (opposite point at 180° won’t
move).

3 Modify the bevel point on selected place, aid of the + and/or + keys.

4 Move forward the curved drawn by the bevel towards the front or the back, aid of the
and keys.

5 Sweep the lens around to display the lens section, aid of the and keys.

6
When the bevel position is correct, press the key to start edging.

Result:After the edging cycle, the visor opens automatically.

7 Hold the edged lens while pressing and holding the key of the keypad (or the one
located at left of the edging station) to open the right side shaft.

8 Remove the lens from the left side adaptor, making sure not to remove the block as
some re-edging might be necessary for proper sizing of lens.

5 - 12 Edging
Accura Cx & Pro

Controlled Groove

Screen Description
Π
Π

Π
Π 1.48 2.97

5.05
00

Symbol Description
1 2
Developed curved of lens slice and grooving centre position:
1. Back Side of Lens 3. Front Side of Lens
3 4
2. Groove Center 4. Position Index
Move the groove towards the back (0.4 mm maximum)

Move the groove towards the front (0.4 mm maximum)

Pivot the groove towards the back of the lens


+
Pivot the groove towards the front of the lens
+
Position Index

1 2 Lens profile corresponding to the current index:


1.48 2.97
1. Front Side Distance from the front edge of the groove
3 5.05
2. Rear Side Distance from the back edge of the groove
3. Value of the lens thickness

→ Move position index view of the lens clockwise

← Move position index view of the lens counterclockwise

Select the groove point whose position will be modified (opposite point is
the pivot; it won't move)
Re-feel the lens

Select the simple groove type (thickness: 0.6 mm) or the double groove
or type (thickness: 1mm, jobs with metal wire)

Automatic lens grooving

Edging 5 - 13
Accura Cx & Pro

Controlled Groove (continued)

Procedure

Follow the steps below to control the lens grooving.

Step Action

1 After roughing and lens feeling cycles, select:


• The grooving type, aid of the Fct5 key.

• The groove base, aid of the and/or .keys.

Π
Π

Π
Π 1.48 2.97

5.05 Fct5
00

2 Select the grooving point whose the position will be modified (opposite point at 180°
won’t move).

3 Modify the grooving point on selected place, aid of the + and/or +


keys.

4 Move forward the curved drawn by the grooving towards the front or the back, aid of the
and keys.

5 Sweep the lens around to display the lens section, aid of the and keys.

6
When the grooving position is correct, press the key to start rimless, polishing
(possibly) then grooving cycles.

Result: After the edging cycle, the visor opens automatically.

7 Hold the edged lens while pressing and holding the key of the keypad (or the one
located at left of the edging station) to open the right side shaft.

8 Remove the lens from the left side adaptor, making sure not to remove the block, as
some re-edging might be necessary for proper sizing of lens.

5 - 14 Edging
Accura Cx & Pro

Retouching a Lens

Prerequisites
Before retouching a lens, make sure of the following:
• The lens block has not been removed from its original lens placement
• The edging parameters have not been altered.

Procedure
Follow the steps below to retouch a lens after edging.

Step Action

1 Place the lens in the edger again.

2
If the lens to retouch comes from the previous job, press the key, if not go to the
following step.

3 Select the side to retouch aid of the Fct1 key. N° 000000000008


Π
Π Fct1

4 Press the Fct5 key.


ORGANIC

Result: The size value appears in inversed


color.
Fct5
+00.00

5 Enter the value to reduce the size, by:


• The keypad or

• The and/or keys.

Note: The correction value is always in a negative form and is limited to a minimum
increment of 00.05 mm.
Warning: If the correction value is > to 0.1 mm then the safety-bevel won’t be
performed.

6
Press the key.
Warning: The retouch cycle can be performed only when the correction value
has been entered.

7 Hold the edged lens while pressing and holding the key of the keypad (or the one
located at left of the edging station) to open the right side shaft.

Edging 5 - 15
6 System Adjustments
Accura Cx & Pro

Edging Wheel Differential Adjustment

Condition

To adjust the wheel differentials, the system must be in rest position (not in scanning or edging
process).

Procedure

Follow the steps below to adjust edging wheel differentials.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

2
Press the key.

Result: The following screen comes up (default values).

Metal frame correction +00.00


Plastic frame correction +00.30
Optyl frame correction +00.50

Roughing differential before Bvl +01.20


Roughing differential before Rim +02.00
Roughing differential before Pol. +00.20

Final size correction - 00.10


Plastic correction +00.00
Polycarbonate correction - 00.10
Pattern correction +00.00

3 Press the key until the appropriate value is highlighted.

Result: The selected value is displaying in inverse colour.

4 Enter the value of the desired wheel differential aid of the keypad.

5 Press the key to validate your entry.

6 Go to the step 3 of this procedure until you adjust all the necessary wheel differentials.

7 Press several times the key to get back to the working mode.

System Adjustments 6-3


Accura Cx & Pro

Frame Correction Adjustment

Condition
To adjust the frame correction, the machine must be in rest position (not in scanning or edging
process).

Procedure
Follow the steps below to adjust the frame correction.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

2 Press the key.

Result: The following screen comes up.

Metal frame correction +00.00


Plastic frame correction +00.30
Optyl frame correction +00.50

Roughing differential before Bvl +01.20


Roughing differential before Rim +02.00
Roughing differential before Pol. +00.20

Final size correction - 00.10


Plastic correction +00.00
Polycarbonate correction - 00.10
Pattern correction +00.00

3 Press the key until the appropriate value is highlighted.

Result: The selected value is displaying in inverse colour.

4 Enter the desired value with the keypad.

IF the frame is in... THEN the value by default is equal to...

Metal 0 mm
Plastic 0.3 mm
Optyl 0.5 mm

5 Press the key to validate your entry.

6 Go from the step 3 of this procedure until you adjust all the corrections.

7 Press several times the key to get back to the working mode.

6-4 System Adjustments


Accura Cx & Pro

User's Language Selection

Procedure

Follow the steps below to select the language.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

SCANFORM ACCURA
V05.00 # 0108 V01.00

User’s language English

Level Expert

Aestheticism control Enable

Retouch control
Patent #97/15242 Enable

2 Press the key facing the line User’s language: English until you display the
desired language:
• English •
• Français • Norge
• Español • Svenska
• Italiano • Srpsko-HrvatskiI
• Deutsch • Suomen
• Nederlands •
• • Japanese
• Portugues •
• Magyar •

3 Press twice the key to get back to the working mode.

4 Switch the machine off then on to confirm the language changing.

System Adjustments 6-5


Accura Cx & Pro

Using Level Selection

2 Levels

The following table describes the 2 using levels of the machine.

Level Using Type

Expert Intend to be used for more advanced functions of the machine such as lens
(Default) layout/blocking (see paragraph Layout and Blocking the Lens in Chapter 4).

Novice Intend to be used for simple functions of the machine.

Procedure

Follow the steps below to select using level.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

SCANFORM ACCURA
V05.00 # 0108 V01.00

User’s language English

Level Expert

Aestheticism control Enable

Retouch control
Patent #97/15242 Enable

2 Press the key facing the line Level until you display Expert or Novice.

3 Press twice the key to get back to the working mode.

6-6 System Adjustments


Accura Cx & Pro

Enable/Disable the Aestheticism Control

Description

• If expert bevel has been selected, the machine performs a control of the bevel placement and
alerts if the calculated bevel may result a non-aesthetic glazing.
• In that case, the edger displays the warning message "Aestheticism" and switch to the bevel
control screen for an eventual modification of the base curve and/or the bevel position by the
operator.
• This control is also performed in case of expert grooving selection.
• It is possible to enable or disable the automatic control for any lens with the following procedure.

Procedure

Follow the steps below to enable/disable the Aestheticism test.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

SCANFORM ACCURA
V05.00 # 0108 V01.00

User’s language English

Level Expert

Aestheticism control Enable

Retouch control
Patent #97/15242 Enable

2 Press the key facing the line Aestheticism control until you display Enable or
Disable.

3 Press twice the key to get back to the working mode.

System Adjustments 6-7


Accura Cx & Pro

Enable/Disable the Retouch control

Introduction

• The retouch control is a test procedure patented by Briot. When this system is activated, and
when a lens retouch is programmed, the machine tests the lens in the machine is effectively the
lens to retouch.
• This procedure increases the security control on the lens but also the process time. You can
enable or disable this test.

Procedure

Follow the steps below to enable/disable the retouch control test.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: According to the type of machine, the following screen comes up.

SCANFORM ACCURA
V05.00 # 0108 V01.00

User’s language English

Level Expert

Aestheticism control Enable

Retouch control
Patent #97/15242 Enable

2 Press the key facing the line Retouch control until you display Enable or Disable.

3 Press twice the key to get back to the working mode.

6-8 System Adjustments


Accura Cx & Pro

Screen Contrast Adjustment

Description

There are 3 types of adjustment to improve visibility of the lens on the scanform™ screen.

Type Function Possible Use

Inverse Colour Key Improve the visibility of the bifocal Bifocal Lens Layout
segment

Screen Brightness Adjust the brightness of the Adapts to the ambient light in the
recorded shape with the screen working lab

Polarizing View Finder Adjust the contrast of the lens with Improves view when decentering of a
the screen dark lens

Inverse Colour

The inverse colour may be changed at any time, by pressing the and keys.

Result: The screen reverses colour.

Notes: The colour will default back to black on white after the system has been switched off.
To return to black on white, press again the and keys.

Screen Contrast Adjustment Keys

• + : Allow to darken the screen contrast

• + : Allow to lighten the screen contrast.

Polarizing Visor

To adjust the brightness of the recorded shape with the screen, rotate the polarizing eyepiece in
either direction to suit you best.

System Adjustments 6-9


Accura Cx & Pro

Scanform Set-up

Purpose

This section provides you with the information required to change the screen contrast, the operator
language and other setting.

Entering the Configuration Mode

To enter the configuration mode, proceed as follows.

Step Action

1 Turn on the Accura.

2
While the machine is initializing, press and hold down for approximately two
seconds. You must do so before the screen changes (loading bar disappears).
Otherwise:
• Wait until the initialisation phase has finished
• Turn the Accura off and on again
• Repeat the procedure from step 1.

Result: The general menu is displayed.

CONFIGURATION
ADJUSTMENT
MTR
COUNTER

Press to enter the configuration mode.

6 - 10 System Adjustments
Accura Cx & Pro

Scanform Set-up (continued)

Exiting the Mode

To exit the configuration mode, proceed as follows.

Step Action

1
In the menu « CONFIGURATION », press to scroll down the menu until « Exit »

is displayed and press .

Result: The general menu is displayed.

2
In the general menu, press to scroll down the menu until « Exit » is displayed

and press .

Result: The scanform is back to normal operation.

Setting the screen contrast

To set the screen contrast, proceed as follows.

Step Action

1 Enter the « CONFIGURATION » menu as indicated in paragraph Entering the


Configuration Mode formerly.

Select the mode « SCREEN CONTRAST » by pressing .

3
Adjust the screen contrast by pressing (clearer) or (darker).

When the contrast is correct, press .

5 Exit the menu « CONFIGURATION » as indicated in paragraph Exiting the Mode


formerly.

System Adjustments 6 - 11
Accura Cx & Pro

Scanform Set-up (continued)

Setting the Operator Language

To set the operator language, proceed as follows.

Step Action

1 Enter the « CONFIGURATION » menu as indicated in paragraph Entering the


Configuration Mode formerly.

2
Press to scroll the line «TEXT LANGUAGE » up to the first line, between the

two arrows and press .

Select the appropriate language and press .


You can choose between the following languages:

• Français

• English

• Deutsch

• Español.

4
In the menu « TEXT LANGUAGE », press to scroll down the menu until « Exit »

is displayed and press .

Result: The menu « CONFIGURATION » is displayed.

5 Exit the menu « CONFIGURATION » as indicated in paragraph Exiting the Mode


formerly.

6 - 12 System Adjustments
Accura Cx & Pro

Scanform Set-up (continued)

Checking the communication protocol

To check the communication protocol, proceed as follows.

Step Action

1 Enter the « CONFIGURATION » menu as indicated in paragraph Entering the


Configuration Mode formerly.

2
Press to scroll the line « PROTOCOL » up to the first line, between the two

arrows and press .

Check that the selected protocol is effectively « San4 ». If not, select it and press .

4
In the menu « PROTOCOL », press to scroll down the menu until « Exit » is

displayed and press .

Result: The menu « CONFIGURATION » is displayed.

5 Exit the menu « CONFIGURATION » as indicated in paragraph Exiting the Mode


formerly.

System Adjustments 6 - 13
Accura Cx & Pro

Scanform Set-up (continued)

Activating / Deactivating the scanform security

To Activate / Deactivate the scanform security, proceed as follows.

Step Action

1 Enter the « CONFIGURATION » menu as indicated in paragraph Entering the


Configuration Mode formerly.

2
Press to scroll the line « PHOTOCELL » up to the first line, between the two

arrows and press .

Activate or deactivate the security (ON or OFF) and press .

4
In the menu « PHOTOCELL », press to scroll down the menu until « Exit » is

displayed and press .

Result: The menu « CONFIGURATION » is displayed.

5 Exit the menu « CONFIGURATION » as indicated in paragraph Exiting the Mode


formerly.

6 - 14 System Adjustments
Accura Cx & Pro

Scanform Set-up (continued)

Setting the stylus type

To set the type of stylus, proceed as follows.

Step Action

1 Enter the « CONFIGURATION » menu as indicated in paragraph Entering the


Configuration Mode formerly.

2
Press to scroll the line « TIP VERSION » up to the first line, between the two

arrows and press .

Set the type of stylus present on your scanform and press .


You can select the following types:

• V1 (the second stylus tip will not be used)

• V3 (the second stylus tip will not be used)

4
In the menu « TIP VERSION », press to scroll down the menu until « Exit » is

displayed and press .

Result: The menu « CONFIGURATION » is displayed.

5 Exit the menu « CONFIGURATION » as indicated in paragraph Exiting the Mode


formerly.

System Adjustments 6 - 15
Accura Cx & Pro

Scanform Set-up (continued)

Set the interface by icons

When using the tracer (Mode Scanform Net 2 only), the messages displayed on the screen (Type of
frame, right or left side, etc.) can be replaced by explicit icons. This menu is to select whatever
interface (text or icons).

To set the interface by icons, proceed as follows:

Step Action

1 Enter into the “ICON” menu.

2 Select and validate the option ON or OFF.

3 Exit from the “ICON” menu

Set the tracing speed

It is possible to modify the tracing speed of the tracer. The selection « Fast scan » (selection by
default) will make the scanner to trace in fast speed. The selection « Slow scan » will make the
scanner to trace in slow speed (speed is identical to the slow tracing selected on the keypad but
the stylus insertion is automatic).

To set the tracing speed, proceed as follows:

Step Action

1 Enter into the “SCANNING SPEED” menu.

2 Select and validate the option « Fast scan » or « Slow scan ».

3 Exit from the “ SCANNING SPEED” menu.

6 - 16 System Adjustments
Accura Cx & Pro

Scanform Set-up (continued)

Set the calibration test

In order to guarantee a correct and constant scanform calibration, it is possible to start the
procedure « Calibration test », see adj.3 each time the scanform is turned on. This check-up can be
enabled or disabled.

To set the calibration test, proceed as follows:

Step Action

1 Enter into the “CALIBRATION TEST” menu.

2 Select and validate the option ON or OFF.

3 Exit from the “CALIBRATION TEST ” menu.

Enable / disable the display of the parameters

When adjusting the scanform, it is possible to display or not the adjustment parameters of the
calibration step that has just been performed.

Not displaying the adjustment parameters can lead to a non detection of a latent
problem laying in the scanform.

To enable or disable the display of the parameters, proceed as follows:

Step Action

1 Enter into the “ADJ. PARAM. DISP” menu.

2 Select and validate the option ON or OFF.

3 Exit from the “ADJ. PARAM. DISP” menu.

System Adjustments 6 - 17
Accura Cx & Pro

Wheel Dressing

Procedure

Follow the steps below to dress a wheel.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

Automatic dressing

Lens sizes adjustment

2 Select the line Automatic dressing.

3 Select the wheel to dress.

4 Load the dressing disk adapted to the wheel to dress, contained in the accessory box.

5 Press the OK key.

6 When the dressing is completed, remove the disk from the edger.

7 Press the Valide key.

8 Press several times the Esc key to quit the adjustment.

9 Adjust the sizes (see paragraph Size adjustment (reset sizes) below).

6 - 18 System Adjustments
Accura Cx & Pro

Size Adjustment (reset sizes)

Procedure
Follow the steps below to adjust the sizes.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

Automatic dressing

Lens sizes adjustment

2 Select the line Lens size adjustment.

3 Insert a lens with a diameter ≥ to 60 mm.

Adjustment Lens Using


1. Finishing Rimless Mineral
2. Mineral roughing Mineral
3. Plastic roughing Plastic
4. Finishing bevel Mineral
5. Polishing Rimless Plastic
6. Polishing Bevel Plastic

4 Press the OK key.

5 When the edging is completed, measure the diameter of the edged lens with a digital
calliper.

6
Enter the measured value, with the and/or keys or with the keyboard.

7
Press the key to confirm the finishing rimless size adjustment.

8 Adjust the following size. Repeat from step 3 of this procedure.

9 When the size adjustment is completed, save your adjustment.

System Adjustments 6 - 19
Accura Cx & Pro

Wheel Counters Consultation

Procedure

Follow the steps below to consult the wheel counters.

Step Action

1 When you are in scanning mode, press simultaneously the and keys.

Result: The following screen comes up.

Roughing
F Wheel 221 0

TP or E Wheel 516 60 Partial Lens


Plastic 482 46
Hi 10 10
Counter
Poly 24 4

Permanent
and Total
Lens Counter

2 Press the key.

Result: The following screen comes up.

Finishing

Rimless 96 45
Mineral 51 10
Plastic 35 25
Hi 10 10
Poly 0 0

Bevel 318 318


Mineral 173 173
Plastic 135 135
Hi 10 10
Poly 0 0

6 - 20 System Adjustments
Accura Cx & Pro

Wheel Counters Consultation (continued)

Procedure (continued)

Step Action

3 Press the key.

Result: The following screen comes up.

Polishing

Rimless 45 35
Plastic 35 25
Hi 10 10
Poly 0 0

Bevel 145 145


Plastic 135 135
Hi 10 10
Poly 0 0

4 Press the key.

Result: The following screen comes up.

Safety bevel

Front side 10 10
Mineral 3 3
Plastic 6 6
Hi 1 1
Poly 0 0

Back side 0 0
Mineral 0 0
Plastic 0 0
Hi 0 0
Poly 0 0

System Adjustments 6 - 21
Accura Cx & Pro

Wheel Counters Consultation (continued)

Procedure (continued)

Step Action

5 Press the key.

Result: The following screen comes up.

Groove Number in
simple width
Groove (Nylon wire)
Total 60 19
Plastic 43 9
Hi 10 10
Poly 7 0

Double 4 1

Groove Number in
double width
(Air-Titanium Type)

6 Press the key.

Result: The following screen comes up.

Retouch

Rimless 0 0
Mineral 0 0
Plastic 0 0
Hi 0 0
Poly 0 0

Bevel 7 7
Mineral 3 3
Plastic 3 3
Hi 1 1
Poly 0 0
Retouch rate 0% 0%

7 Press the key to come back to the working mode.

6 - 22 System Adjustments
Accura Cx & Pro
Adjusting the Scanform Unit

Purpose

This section enables you to adjust the Scanform unit using the various tools supplied.

Running the Adjustment Procedure

This “Start” option will actually start the calibration procedure.


It’s a step by step procedure, requiring the use of 4 specific tools, located into the user black box.

For safety purpose, previous calibration values will be preserved if the ongoing calibration fails before
reaching it’s very end.
Once fully performed, new calibration values will be taken into account, only if the “Save” option is
chosen.

Step Action

1
Select Run and press .

Result: The initialisation sequence is performed.

2
When the icon comes up, insert the gain adjustment jig (shown below)

as requested and press .

Result: The icon comes up. You are asked to confirm the tool
length engraved on the tool (default = 40.00 mm). You can change the length
in increments of 0.01 mm using and .

3
When the required length is displayed, press .

Result: The icon comes up. You are asked to confirm the tool
height engraved on the tool (default = 24.00 mm). You can change the height
in increments of 0.01 mm using and .

System Adjustments 6 - 23
Accura Cx & Pro

Adjusting the Scanform Unit (continued)

Running the Adjustment Procedure (continued)

Step Action

4
When the required height is displayed, press .

Result: The machine starts adjusting the gain.

5 When the machine has finished, use and to scroll through the following
values:
• Tip offset
• Rho gain
• Z gain

Note: ! signifies that the value is out of range, in which case you must perform
the Scanform calibration procedure again.

6 To… Press…

Repeat the adjustment (go to step 2)

Confirm the values and perform


the next adjustment (go to step 7)

7
When the icon comes up, insert the scanform axis adjustment jig

(shown below) as requested and press .

Result: The icon comes up. You are asked to confirm the
diameter of the round section (on the right) engraved on the tool
(default = 40.00 mm). You can change the diameter in increments of 0.01 mm
using et .

6 - 24 System Adjustments
Accura Cx & Pro

Adjusting the Scanform Unit (continued)

Running the Adjustment Procedure (continued)

Step Action

8
When the required diameter of the round section is displayed, press .

Result: The machine scans the round section.


9 When the machine has finished, use and to scroll through the following
values:
• Thickness
• Offset:
• R insertion
• Rho
• Circumference
• Radius:
• Minimum
• Maximum

Note: ! signifies that the value is out of range, in which case you must perform
the Scanform calibration procedure again.

10
To scan the rectangular section on the left, press .

11 When the machine has finished, use and to scroll through the following
values:
• Frame axis
• Circumference
• Right Dx
• Left Dx
• R Dx - L Dx

12 To… Press…

Repeat the adjustment (go to step 7)

Confirm the values and perform the next


adjustment (go to step 13)

System Adjustments 6 - 25
Accura Cx & Pro

Adjusting the Scanform Unit (continued)

Step Action

13
When the icon comes up, insert the pattern jig as requested with the

round pattern (shown below) attached and press .

Result: The icon comes up. You are asked to confirm the
diameter engraved on the tool (default = 40.00 mm). You can change the
diameter in increments of 0.01 mm using and .

14
When the required diameter is displayed, press .

Result: The machine scans the round pattern.

15 When the machine has finished, use and to scroll through the following
values:
• Pattern offset
• Circumference
• Radius:
• Minimum
• Maximum

16 To… Press…
Repeat the adjustment (go to step 13)

Confirm the values and perform the next


adjustment (go to step 17)

6 - 26 System Adjustments
Accura Cx & Pro

Adjusting the Scanform Unit (continued)

Running the Adjustment Procedure (continued)

Step Action

17
When the icon comes up, insert the pattern jig as requested with the

rectangular pattern (shown below) attached and press .

Result: The machine scans the rectangular pattern.

18 When the machine has finished, use and to scroll through the following
values:
• Pattern axis
• Circumference
• Pattern D
• Pattern Dy

19 To… Press…
Repeat the adjustment (go to step 17)

Save the adjustments and return to the


Adjustment menu

Return to the adjustment menu without


saving the parameters

System Adjustments 6 - 27
Accura Cx & Pro

Lens Feelers Adjustment

Procedure

Follow the steps below to adjust the scanning system.

Step Action Diagram

1 Go to the scanning screen. -

2 Press simultaneously the and


keys.

Result: The following screen comes up.

Lens feelers adjustment


Yes No

3 Press the Yes key.

Result: The following screen comes up.

Assemble tool n° 14 04 199


Valid Esc

4 Put adjustment tool n° 14 04 199 on the lens


adapter shaft (left side).

5 Press and hold the key to close lens -


clamping.

6 Press the Valid key. -

Result: The adjustment is automatically


performing.

6 - 28 System Adjustments
Accura Cx & Pro

Lens Feelers Adjustment (continued)

Procedure (continued)

Step Action Diagram

7 When the adjustment is performed, -


remove the tool n° 14 04 199 and press on
Valid.

8 Press the Fct7 key to save the adjustment.

Result: The scanning screen comes up.

Fct7

Note: This calibration influences the bevel tracking. A calibration performed poorly can
induce a bad work quality of the edger.

System Adjustments 6 - 29
7 System Cleaning
Accura Cx & Pro

Cleaning the Edger

Introduction
In order for your new system to retain its new appearance and ensure proper mechanical operation,
simple care must be taken on a routine basis:
• Clean the edger daily after use
• Follow the direction mentioned in this section
• Care your Briot after sales technician to arrange periodic maintenance.

Daily Cleaning
Basic daily cleaning consists of :

• Dust removal by using:


• Pure water or Briot Rex Net
• A soft sponge
• Mild soap or glass cleaner or
• A soft brush. Always wet edger surfaces with a spray bottle with water, to avoid scratching
when cleaning.

• Carefully dust removal of the scanform™ feeler tip.

Caution

Do not use any type of spray hose to clean your system. Avoid any heavy splashing or
spraying that may penetrate the system's scanning and keyboard/interface. This can cause
electrical damage to the system.

Never use chemical solvents, agents or derivatives of such products as:


• Acetone
• Trichlorethylene
• Benzene
• Kerozene
• Lighter Fluid or
• Any product that claims "Do not use on plastic or painted surfaces" or that contains
CHLORINE, AMMONIA, SODA.
These products directly or even by their simple vapors:
• Might alter the structure and appearance of your system
• Usage of any of these materials will void any guarantee or warranty of the whole unit
or its components.

Never manipulate the lens feeler pliers located in the edging station.

System Cleaning 7-3


8 Maintenance
Accura Cx & Pro

Scanform messages

What to Do in Case of a Warning Message

The following tables list the most common messages that you might encounter when using the
Accura.

Message Possible cause(s) Solution(s)

Incorrect tool The tool used is not recognized as Use exclusively tools and
a standard scanform tool. accessories provided

No tool The required tool has not been Insert the correct tool
inserted

No pattern The required pattern has not been Insert the correct pattern
inserted

Frame moved The frame moved during scanning Ensure that the frame is placed
correctly in the scanform

No frame The required frame has not been Insert the correct frame
inserted

Scanform™ VI Errors

If any of the following errors are detected, take the relevant action described.

Error # Error message Solution(s)

EC03 Carriage error, loss of steps Ensure that there is no obstruction to the carriage

EL03 Impossible connect., Job Ensure the Scanform Net is correctly connected to the
not sent OMA server and that the OMA application is started

EM01 Jaws error, No frame Insert a frame in the Scanform

EM02 Jaws error, timeout Ensure that there is no obstruction to the jaws

EM03 Jaws error, Frame present Ensure that the frame is removed prior to the initialisation
phase

EP01 Stylus out, Invalid trace The stylus has come out of the frame. Restart the scan
using the slow setting

Maintenance 8-3
Accura Cx & Pro

Scanform messages (continued)

Scanform™ VI Errors (continued)

Error # Error message Solution(s)

EP02 Frame moved, Invalid trace Closing error - the point at which the scan began does not
correspond to the point at which it finished (rho and Z).
Restart the scan using the slow setting. This error is
normally caused by the frame moving during the scan

EP04 Stylus error, Insufficient Ensure that there is no obstruction to the stylus horizontal
stroke movement

EP05 Insert. error, Insufficient The stylus cannot reach the end of its horizontal stroke.
stroke Ensure that there is no obstruction preventing the stylus
from moving back and forth during the initialization step

EP07 Height error, insufficient The stylus cannot reach the end of its stroke. Ensure that
stroke there is no obstruction preventing the stylus from moving
upwards

EP08 Stylus out, Scan pattern The tracer could not trace the pattern. Restart the scan
error using the slow setting

ER01 Turret, timeout Ensure that there is no obstruction to turret

ER03 Turret, Jamming: photocell The turret is jamming. Ensure there is no stopping point
along its rotation movement

ET01 Rods error, timeout Ensure that there is no obstruction to the rods

ET03 Rods error, Insufficient Ensure that there is no obstruction to the rods and frame
stroke clips

EA01 Adjustment error The calibration failed. Do it again

8-4 Maintenance
Accura Cx & Pro

Edger messages

Message Types

The following table describes the messages of the operator dialogue.

Type Description Acquittal

Warning Allow to pay attention on an By OK.


illogical procedure or a minor
N° 000000000008
event. Π
Π

ORGANIQUE

*****WARNING***** *****WARNING*****
Origin: Edging
Type: Radius < 10 mm +00.00
OK

Question Indicate that you must choose By Yes or No.


between two solutions.
N° 000000000008
Π
Π

ORGANIQUE

*****WARNING***** *****WARNING*****
Origin: Edging
Type: Re-edge same lens? +00.00
Yes No

• While the message is displayed, the operator dialogue is inhibited.

• The message area disappears from the screen when the message is acknowledged.

Maintenance 8-5
Accura Cx & Pro

Edger messages (continued)

Scanform™ origin

The following table shows the messages that can display during the scanform™ use.

N° Message Cause

01 05 Tracing aborted
You pressed the key during scanning cycle for

example.

01 09 No Scanform Link problem with the scanform™.

01 10 Shape closure prob., The frame has possibly moved during tracing. The
continue? calculation algorithm can correct this problem but the
lens edged may not match the frame shape ( size a
little too large)

• Yes: correct the problem and carry on.

• No: stop the process and trace the frame again.

Layout origin

The following table shows the messages that can display in the layout mode.

N° Message Cause

02 03 Unknown job Call of one job number being neither the current job nor
the previous job aid of the keypad.

Scanning origin

The following table shows the messages that can display in the scanning mode.

N° Message Cause

03 01 Memory full More than 300 jobs in memory (permanent or volatile


jobs not edged).

03 04 Overwrite the present job? You start a scanning cycle of a job already scanned.

03 05 Edging previous job While you create the job n° 3 whereas the job n° 1 is
in edging cycle.

8-6 Maintenance
Accura Cx & Pro

Edger messages (continued)

Scanning origin (continued)

N° Message Cause

03 06 Overwrite the job in memory? • The job number to save already exists in memory.
• If not, the job is saved under another number.

03 08 Edging present job You try to scan again the present job during the
edging of this job.

03 09 Are you sure? If yes, the current job is deleted.

03 11 Incompatible edger config. Incompatibility problem between job parameters and


edger setting.

Example: Job with Polycarbonate lenses on a


machine not equipped with TP wheel.

Edging origin

The following table shows the messages that can display in the edging mode.

N° Messa ge Cause

04 01 Retouch impossible A retouch is required while a lens has not been edged
yet.

04 02 Lens feelers not in position One of the lens feelers was not in correct position
before sensing the lens. Check there is no lens debris
preventing a normal motion of the lens feelers.

04 04 Small adapters mounted? Frame shape requires the adapters Ø 19mm. Make
sure they are mounted before going on.

04 05 Lens too small for shape Lens too small or too decentered in comparison with
the shape.

04 06 Radius < 10 mm Shape too small. (Try to work in boxing mode.)

04 07 Re edge same lens? Lens edging from a job on the screen already edged.

04 08 Bevel too much at the back Top of the bevel more than 5 mm from the front face.

Maintenance 8-7
Accura Cx & Pro

Edger messages (continued)

Edging origin (continued)

N° Message Cause

04 09 Safety bvl: radius too small Radius too small for safety bevel.

04 10 Do you want to continue? This message appears when the edging time
exceeded the limit of the machine (8 min). The
operator has the choice to continue or stop the edging
process.

04 11 Lens too thick for rimless Lens thickness higher than 10.4 mm.

04 12 Finishing impossible Finishing time upper than 3 min (carriage contact


problem).

04 13 Groove. Lens too small One of the diameter of the lens is too small and the
sockets may touch the safety-bevel/grooving wheel.

04 14 Impossible edge Problem on the main motor. Rotation speed too low or
null.

05 02 Grooving wheel too small Grooving wheel worn out. The depth can not be
reached.

05 03 Lens too thick to groove • Lens thickness upper than 9.55 mm between front
face and grooving (lens safety-bevel/bush collision
possible).
• Lens thickness upper than 9.60 mm between rear
face and grooving (lens safety-bevel/wheel collision
possible).

05 04 Groove. Lens too thin <1.5 mm Lens thickness is lower than 1.5 mm.

05 05 Grooving impossible Too much lens curve.

05 06 Bevel top out lens During automatic bevel, the machine detects that the
Continue? bevel may go out of the lens edge. Shall we finish the
lens?

05 07 Lens feelers : Aberrant spots Irregular points detected during lens tracing.

Example: For a 1/2 eye lens, the adhesive has not


been cut before blocking.

8-8 Maintenance
Accura Cx & Pro

Edger messages (continued)

Edging origin (continued)

N° Message Cause

05 08 Job not aesthetical The bevel or groove calculated by the expert program
might result a non aesthetic glazing. The operator can
modify its base curve and/or position upon his criteria.

05 09 Improper lens to retouch The inserted lens doesn’t match with the lens to
retouch – Check lens side (R/L) or that the lens is not
an uncut lens.

05 10 Finish. dressing recommended The Accura recommends to dress the finishing (bevel)
wheel (more than 800 lenses edged since the last
dressing).
Acknowledge the message and proceed to the
finishing wheel dressing.

05 12 Small flat adapters mounted? Frame shape requires the adapters Ø 17mm. Make
sure they are mounted before going on.

05 13 Thin lens to groove, continue? Part of the lens has a thickness between 1mm and
1.4mm and the groove may be fragile.

05 14 Large adapters mounted? Frame shape requires the large adapters. Make sure
they are mounted before going on.

Extension circuit board origin

The following table shows the message that can display because of the extension circuit board.

Type Message Cause

06 01 Extension board failure Communication problem between main circuit board


and memory extension circuit board.

06 02 <Server message> There is no connection with the OMA server.

Maintenance 8-9
Accura Cx & Pro

Edger messages (continued)

Safety mode origin

The following table shows the messages that can display in the safety mode.

Type Message Cause

08 01 Clamp the lens before start The lens has to be clamped before starting the edging
cycle. Put the lens between the chucks, clamp it and
start the cycle.

08 02 Clamp the tool before start The tool has to be clamped before starting the
calibration cycle. Put the tool between the chucks,
clamp it and start the cycle.

8 - 10 Maintenance
Appendix A Installing a Recirculating
System
Accura Cx & Pro

Installing a Recirculating System

Warning

Only pumps that comply with the relevant safety requirements are permitted:
• 230 V: Output of pump outlet
• 350 W: Power available (for the pump).

Procedure

Follow the steps below to install a recirculating system.

Step Action

1 Place system assembly under workbench.

2 Feed the following through the pre-drilled holes on the work bench top:
• Main Supply Water Hose (Accura Pro)
• Visor and Polycarbonate Supply Water Hose.
To do this, see the diagram below.

3 Connect the recirculating system's power cord into the electrical outlet.

4 Fill the recirculating tank with water ¾full.

5 Start the machine without a lens to prime the pump.

Diagram

The following diagram shows the installation of your recirculating system.

Edger
Electrical (Front View)
Connection Visor/Polycarbonate Do not mount the joint filter on
Water Supply
Main Water the water supply in case of a
Supply recirculating system.
(Acura Pro) Drain
Pump
Filter Decantation/Filter

Installing a Recirculating System A–3


Accura Cx & Pro

Cleaning the Pump Recirculating System

Procedure

Cleaning the pump recirculation system can be done at different levels.

Note: The recirculating tank should be cleaned periodically, with more frequency if the workload
increases. It is recommended to clean the tank and change the water every 50 jobs.

Level Condition Action Diagram

1 Everyday's Slide out the drawer filter and clean it.


cleaning

2 • Low water Take out the pump tank with the pump.
flow • Brush the filter (sides) of the pump tank
• Pump • Put back the assembly on the main tank.
floats in
the tank • Add water if necessary.

3 Low water flow Complete cleaning of the system :


even after • Empty the main tank (See paragraph
intervention Emptying Main Tank below).
on 1st and 2nd
level • Take out the pump tank with the pump.
• Remove, empty and clean the decantation
tank with a brush. The mud will be dumped in
the main tank.
• Remove and throw away the plastic bag of the
main tank.
Empty
• Put back all the parts of the system after decantation
installing a new plastic bag in the main tank. tank in the
• Fill the tank up to 6 to 7 mm (2-3 inches) from plastic bag
the top of the main tank.

• Make a void cycle (no lens) to prime the


pump and edger.

A–4 Installing a Recirculating System


Accura Cx & Pro

Cleaning the Pump Recirculating System (continued)

Emptying Main Tank

Follow the steps below to empty the main tank.

Step Action

1 Switch off the edger.

2 Press the key while you switch on the edger.

Result: The following screen comes up.

Fct1
ON

3 Disconnect the main water supply pipe (edger side) and connect the dump pipe to the
main drain (bucket, sink, sewer, etc.).

4 Start the pump by pressing the Fct1 key until you display OFF.

5 Turn on the faucet of the dump pipe.

Result: The main tank dumping starts.

6 When the dumping is finished, press the Fct1 key to display ON.

Result: The pump stops.

7 Turn off the faucet of the dump pipe.

8 Re-connect the water supply pipe to the edger.

9
Press the key to reboot the machine.

Installing a Recirculating System A–5


Appendix B Functioning with Memory
Board & Network
Connection
Accura Cx & Pro

Bar Code Reader

Connection to the edger

Connect the bar code reader cable on the back connector (9-pin connector).

I
O ATTENTION: Débranchez la prise
de courant avant toute intervention
sur la machine
WARNING : Disconnect supply before
removing covers
WARNUNG : Bitte ziehen sie
unbedingt den stecker aud d e r
steckdose bevor sie die maschine off CE
FRANCE: Conforme aux réglements du ministère du travail à la
Constructe Année de
Herstel BRIOT Jah
Manufactur F27 - PONT DE 1996
Year
Immatricula
Seriennumm N° Q 51
Serial 22034
230 V 1~ 50 Hz 1000 W 4 A

Servi Contin T/min. a Protecti IP 20


Betriebsa D B 2800 U/min Schutza
Runnin Continuou RPM
Leerlauf
g Made in

Using

When you are in the scanning mode, move closer the bar code reader over the bar code label of
the tray or of the frame for example.

Result:
• A new job is created (if no number in the memory) wearing the number referenced by the bar
code reader.
Or
• The job number, the shape and/or the selected job parameters come up on the screen (if
already present in memory).

Functioning with Memory Board & Network Connection B–3


Accura Cx & Pro

Memory Extension Circuit Board

Creation and Saving a Job

Follow the steps below to create and save a job.

Step Action

1 Press one or several times the Fct0 to access to scanning mode.


F c t 0

N° 000000000008

METAL

+703
.8

F c t 6 F c t 8 F c t 9

2 Enter a job number aid of the keyboard or the bar code reader.

3 Press the Fct6 key to display job origin (in this case the scanform™ ).

4 Press the Fct8 key to indicate to the machine that you wish to save this new job.

5 Press the Fct9 key to select the memory zone where the job will have to locate.

Setting Function

Save the job in non protected memory: the job is staying in memory:
• As long as there is room left in memory and
• As long as the job has not been edged.

Save the job in protected memory: the job is staying always in


memory (except if you wish to delete it).

6 Enter the scanning parameters and scan your job. To do this, see Chapter 3 Scanning.

7 Access to layout/blocking screen and enter data concerning this job (distance, high…).
To do this, see Chapter 4 Layout/Blocking.

8 Access to edging screen and enter data concerning this job (lens type, bevel, safety-
bevel…). To do this, see Chapter 5 Edging.

B–4 Functioning with Memory Board & Network Connection


Accura Cx & Pro

Memory Extension Circuit Board (continued)

Creation and Saving a Job (continued)

Step Action

9 Press the Fct0 key to access again to scanning screen.

10
Create a new job, aid of the keyboard, the bar code reader or the key.

Result:

If the job Then…


number…

Is not in memory The job is now saved on specified number.

Is in memory The following message comes up:


N° 000000000008

METAL

+70.38

*****WARNING***** *****WARNING*****
Origin : Tracing
Type : Overwrite the present job ?
Yes No

If you… Then…

Press Yes • The job that existed before under the same number
is overwritten.
• The job just created is now in memory.

Press No • The following screen is displaying with the job


number on which the new job will be saved.
N° 000000000008

METAL

+703
.8
*g**in**W ARN ING**********WARNING*****
Ori
Type ::Job
Traci
#ngOk 00007

Functioning with Memory Board & Network Connection B–5


Accura Cx & Pro

Memory Extension Circuit Board (continued)

Advises

• Note properly the job number you just created. It equivalents to the new job number
for a further call.

• If you wish to save the last job of the day, do not forget to press the key in
scanning mode before switching off the machine.

• If you use the tray number as job number, it is advisable to answer Yes to the
message Overwrite the present job?. Otherwise, the job will be saved under another
number.

B–6 Functioning with Memory Board & Network Connection


Accura Cx & Pro

Memory Extension Circuit Board (continued)

Call a Job in Memory

Follow the steps below to call a job in memory.

Step Action

1 Press one or several times the Fct0 key to access to scanning mode.

Fct0
N° 000000000008

METAL

+70.38

Fct6 Fct8

2 Enter the job number to recall, aid of the keyboard or the bar code reader.

3
Press the Fct6 key to display the job origin (in this case the memory ).

4 If necessary, press the Fct8 key to save the job if you think you will modify it.

5
Press the key to call the job.

Result: The saved job is displaying.

6 Access to layout/blocking and edging screens to block the job lenses and to edge them.
To do this, see Chapter 4 Layout/Blocking and Chapter 5 Edging.

7 If you selected saving option , repeat steps 9 and 10 of procedure Creation and
Saving a Job formerly.

Functioning with Memory Board & Network Connection B–7


Accura Cx & Pro

Memory Extension Circuit Board (continued)

Deletion of Jobs

Follow the steps below to delete all or part of jobs in memory.

Step Action

1 When you are in the scanning screen, press simultaneously the and
keys.
Result: The following screen is displaying.

Mem VXX.XX

Fct3
Fct4
Fct5

2 Press one of the following keys according to the desired deletion.

Key Function

Fct3 Delete all the jobs in memory.

Fct4 Delete all the non-protected jobs in memory.

Fct5 Delete all the protected jobs in memory.

Result: The following message comes up.

Mem VXX.XX

*****WARNING***** *****WARNING*****
Origin : Tracing
Type : Are you sure ?
Yes No Non

3 Press the Yes key to confirm the deletion.

4
Press the key to get back to the working mode.

B–8 Functioning with Memory Board & Network Connection


Accura Cx & Pro

Communication Extension Circuit Board

Creation and Saving a Job

Follow the steps below to create and save a job.

Step Action

1 Press one or several times the Fct0 to access to scanning mode.


F c t 0

N° 000000000008

METAL

+703
.8

F c t 6 F c t 8

2 Enter a job number aid of the keyboard or the bar code reader.

3
Press the Fct6 key to display job origin (in this case the scanform™ ).

4 Press the Fct8 key to indicate to the machine that you wish to save this new job.

5 Select the server memory zone where the job will have to locate.

6 Enter the scanning parameters and scan your job. To do this, see Chapter 3 Scanning.

7 Access to layout/blocking screen and enter data concerning this job (distance, high…).
To do this, see Chapter 4 Layout/Blocking.

8 Access to edging screen and enter data concerning this job (lens type, bevel, safety-
bevel…). To do this, see Chapter 5 Edging.

9 Press the Fct0 key to access again to scanning screen.

Functioning with Memory Board & Network Connection B–9


Accura Cx & Pro

Communication Extension Circuit Board (continued)

Creation and Saving a Job (continued)

Step Action

10
Create a new job, aid of the keyboard, the bar code reader or the key.

Result:

If the job number… Then…

Is not in server The job is now saved on specified number.


memory

Is in server memory The following message is displaying:


N° 000000000008

METAL

+703
.8
*****W
Origin ARNING**********WARNING*****
:Overwri
Tracing
Type
Yes No tethepresentjob?
:

If you… Then…

Press YES • The job that existed before under the same
number is overwritten.
• The job just created is now in server memory.

Press NO • The following screen is displaying with the job


number on which the new job will be saved.
N° 000000000008

METAL

+70.38

*****WARNING***** *****WARNING*****
Origin : Tracing
Type : Job # 00007
Ok

B – 10 Functioning with Memory Board & Network Connection


Accura Cx & Pro

Communication Extension Circuit Board (continued)

Advises

• Note properly the job number you just created. It equivalents to the new job number
for a further call.

• If you wish to save the last job of the day, do not forget to press the key in
scanning mode before switching off the machine.

• If you use the tray number as job number, it is advisable to answer Yes to the
message Overwrite the present job?. Otherwise, the job will be saved under another
number.

Functioning with Memory Board & Network Connection B – 11


Accura Cx & Pro

Communication Extension Circuit Board (continued)

Call a Job in Memory

Follow the steps below to call a job in the memory of the server.

Step Action

1 Press one or several times the Fct0 key to access to scanning mode.
F c t 0

N° 000000000008

METAL

+703
.8

F c t 6 F c t 8

2 Enter the job number to recall, aid of the keyboard or the bar code reader.

3 Press the Fct6 key to display the job origin (in this case the server ).

4 If necessary, press the Fct8 key to save the job if you think you will modify it.

5
Press the key to call the job.

Result: The saved job comes up.

6 Access to layout/blocking and edging screens to block the job lenses and to edge them.
To do this, see Chapter 4 Layout/Blocking and Chapter 5 Edging.

7 If you selected saving option , repeat steps 9 and 10 of procedure Creation and
Saving a Job formerly.

B – 12 Functioning with Memory Board & Network Connection


Appendix C Specifications
Accura Cx & Pro

Specifications: Accura Cx & Pro

Scanform™ Scanner

• Automatic Initialization • Automatic Tracing in 3D of two or one circles


• Automatic Frame Positioning as required

• Automatic Insertion of the Stylus • Frame groove angle automatic measurement


by insertion of a second stylus tip into the
• Scan frame, pattern, cut lens or presentation frame
lens
• Automatic Measuring of the frame deviation
• Automatic detection of insertion of a pattern or
demonstration lens • Tracing frame Diameter:
∗ Maximum: 80 mm
∗ Minimum: 21 mm

Layout/Blocking

• Operator Interface using Icons • Servo controlled lens blocking


• LCD colour screen • Lens blocking by Adhesive only
• Screen Contrast and Video Reverse Control • Patient’s data entered via the keypad
• Lens Wheels Choice: (minimum step: 0.10 mm):

∗ Roughing: Glass or Plastics (CR 39, ∗ Horizontal input: Boxing shift, Mono PD, or
Polycarbonate and High Index Organic) full PD.

∗ Finishing: Controlled bevelling (Automatic, ∗ Vertical Input: BOX height, pupil height in
Expert, Front Face, Rear Face, 1/3-2/3, boxing center, or pupil center blocking
1/2-1/2, Frame Base, Lens Base), Note: All data combinations are accepted by
Rimless, Polishing, Safety-bevel, Grooving the computer:
• Assembly Job Number Display ∗ Blocking cross for single vision, bifocal
• Optical Center Blocking (with adjustment of bifocal segment width),
• Boxing Center Blocking with Automatic progressive
Parallax Correction ∗ Adapter / grinding wheels anti-collision
• Possible lens viewing before finishing: profile, device (warning of the operator with small
front, full bevel track. sockets)

Specifications C– 3
Accura Cx & Pro

Specifications: Accura Cx & Pro (continued)

Edging Station

• Automatic Initialization • Quick Connect Water Connection


• Lens front and rear face tracing: 3D • Lens Edging Diameter:
• Equipment: ∗ ≤ to 80 mm
∗ Roughing Glass Edging ∗ Rimless: 17.75 mm
∗ All Plastics Edging (CR 39, High Index, ∗ Bevel: 19.50 mm
Polycarbonate) ∗ Grooving: 18.50 mm
∗ Bevel/Rimless Finishing Edging ∗ Rimless safety-bevel: 21.30 mm
∗ Bevel/Rimless Polishing Edging ∗ Safety-bevel: 22.90 mm
• Automatic Clamping Pressure • Automatic cleaning of lens chucking system
• Edging pressure controlled according to the and edging chamber
lens material • Water supply: 20x27 mm Adapter
• Safety-bevelling: Front and/or Rear Sides • Drain Size: ∅ 100 mm (4.0”)
• Built-in Job Memory: 2 jobs • Water Supply Pressure: from 4 to 7 bars
• Optional memory extension: 300 jobs • Network Connection
• Lens Grooving in 0.6 mm Plain Width (Nylon
wire) or 1 mm Double Width (Metal wire)

C–4 Specifications
Accura Cx & Pro

Specifications: Accura Cx

Specifications

• Dimensions: • Fuses to be used for 115 V edger:


∗ Width: 26” (660 mm) ∗ F1 & F2 : 25 AT Ferraz 125 V
∗ Depth: 24” (620 mm) SA 6,3x32 Ref. T84 427

∗ Height (visor close): 17” (430 mm) ∗ F3 : 5 AT Ferraz 250 V 5ST 5x20

∗ Height (visor open): 20.5” (520 mm) ∗ F4 & F5 : 5 AT Ferraz 250V


55T 5x20
• Weight: 165 lb. (75 kg)
∗ F6 : 5 AT Ferraz 250V 55T 5x20
• Power Supply: 230 V/50 Hz, 115 V/60 Hz
• EC Standards for 230V EC Version:
• Power Consumption: 1000 W
∗ In compliance with Safety EC Requirement
• Sound Level: 72 dB Di 89/392/CEE
• Pollution Degree: 2 ♦ EN 60204
• Installation Category: II ♦ EN 60950
• Ambient Temperature: 13° C to 35° C ♦ EN 60742
• Relative Humidity: 10% to 80% ∗ In compliance with EMC EC Requirement
• Maximum Water Pressure: 7 Bar Di 89/336/CEE
• Maximum Pump Pressure (with Pump): 7 Bar ♦ EN 55022 "Class B"
• Output of Pump Outlet: ♦ EN 61000 - 4 - 2
∗ 115 V/230 V: Supply Voltage ♦ EN 61000 - 4 - 3
∗ 350 W: Power available (for the pump) ♦ EN 61000 - 4 - 4
• Fuses to be used for 230 V edger: • UL Standards for 115V US Version:
∗ F1 & F2 : 10 AT Little Fuse 32606 ♦ UL 3101
∗ F3 : 3,15 AT Little Fuse 2183-15 ♦ FCC part 15, subpart J. Class A
∗ F4 & F5 : 2 AT Little Fuse 218002
∗ F6 : 5 AT Ferraz 250V 55T 5x20

Specifications C– 5
Accura Cx & Pro

Specifications: Accura Pro

Specifications

• Dimensions: • Fuses to be used for 230 V edger:


∗ Width: 26” (660 mm) ∗ F1 & F2: 10 AT Little Fuse 32606
∗ Depth: 24” (620 mm) ∗ F3: 3,15 AT Little Fuse 2183-15
∗ Height (visor close): 17” (430 mm) ∗ F4 & F5: 2 AT Little Fuse 218002
∗ Height (visor open): 20.5” (520 mm) ∗ F6: 5 AT Ferraz 250V 55T 5x20
• Weight: 165 lb. (75 kg) ∗ F7: 2 AT
• Power Supply: 230 V/50 Hz, 60 Hz • EC Standards for 230V EC Version:
• Power Consumption: 500 W ∗ In compliance with Safety EC Requirement
• Sound Level: 72 dB Di 89/392/CEE

• Pollution Degree: 2 ♦ EN 60204

• Installation Category: II ♦ EN 60950

• Ambient Temperature: 13° C to 35° C ♦ EN 60742

• Relative Humidity: 10% to 80% ∗ In compliance with EMC EC Requirement


Di 89/336/CEE
• Maximum Water Pressure: 7 Bar
♦ EN 55022 "Class A"
• Maximum Pump Pressure (with Pump): 7 Bar
♦ EN 61000 - 4 - 2
• Output of Pump Outlet:
♦ EN 61000 - 4 - 3
∗ 230 V: Supply Voltage
♦ EN 61000 - 4 - 4
∗ 350 W: Power available (for the pump)
♦ UL Standards for 115V US Version: UL
3101

C–6 Specifications

Вам также может понравиться