Вы находитесь на странице: 1из 8

Technical

Information Pressure Transmitter


TI 291P/24/ae
cerabar T PMP 131

Pressure transmitter with polysilicon sensor


for absolute and gauge pressures up to 6000 psi

Applications Measuring system


The Cerabar T PMP 131 pressure • Cerabar T PMP 131 pressure
transmitter is suitable for a wide variety transmitter with 4 to 20 mA output or
of industrial pressure processes of switch output
liquids, gases, and vapors. It is a • 12 to 30 VDC power supply
compact, economical system that
provides measurement in gauge or 4 to 20 mA
absolute pressures from full vacuum to
6000 psi.

Features and benefits


• Fixed measuring ranges up to
6000 psi (400 bar)
• Up to 4 times overload resistance
• Extremely stable
• Flush diaphragm process connection
Power supply
or 1/2” NPT connection
• Electronic versions with:
- 4 to 20 mA analog output
- PNP transistor switch output

The Power of Know How


Operation Zero point adjustment
For the PMP 131 with analog output and
plug, the zero point can be adjusted to
±5%. The potentiometer used for this
adjustment is located below the plug
base.
+

1+ 2–

Mounting boss

Zero point adjustment


• Remove plug Potentiometer for zero
• Loosen coupling nut point correction, ± 5%
(potentiometer is located on
• Remove mounting boss the component side)
Do not turn the cap nut
when loosening or
tightening the base of
the plug!

Switch point and deadband


adjustment
For the PMP 131 with switch output, both Endress+Hauser offers a test cable for
the switch point and deadband can be connecting the voltmeter to the test pin.
adjusted. This can also be carried out at Part Number: 52005674
atmospheric pressure using a test cable
and voltmeter. The potentiometer used
for this adjustment is located below the
plug base.

R +

1+ 3+ 2–

Deadband adjustment
1.5 to 20% FS Mounting boss
(factory setting, 10% FS)

Switch point and


Deadband adjustment + – LED color code
RED = ON
• Remove plug GREEN = OFF
• Loosen coupling nut
• Remove mounting boss Switch point adjustment Adjustment at atmospheric pressure:
0 to 100% FS Connect the voltmeter to the test pin.
Do not turn the cap nut (factory setting, 50% FS) 0 to 1 V corresponds to 0 to 100% FS
when loosening or
tightening the base of
the plug!

Instructions for switch point and


deadband adjustment

Deadband
Uout 1.5 to 20% FS
ON
Red LED

Switch ON Switch OFF

Green LED OFF

Switch point and deadband


adjustment
FS: Full Span (measuring
range) p
Uout: output voltage Switch point
p: acting pressure Adjustment 0 to 100% FS

2
Electrical Connections
Red
+
Plug-in White
housing –
Green
GND

Plug-in Atmospheric pressure


connector reference tube
Gasket
Coupling nut

Mounting boss
O-ring

PMP 131 with plug connector PMP 131 with cable

Connector Analog output 4 to 20 mA


DIN 43 650/A 2-wire
1 Power supply and output (+)
2 Power supply and output (–)
3 not assigned
Ground (GND)
1
Switch output
2 3-wire
1 Output (+)
2 Power supply and output (–)
3
3 Power supply (+)
Ground (GND)

PMP 131 plug version, pin assignment

Switch output PNP


Preferably used with programmable PMP 131
logic controllers (PLC).
Positive signal at the switching output of
the electronics (PNP); output blocked on
reaching limit.
3 2 1
(+)

0.5A

e.g. Relay,
PLC (-)

L+ L-
Input power 18 to 32 VDC

Three-wire PNP DC connection

3
Technical Data

General Specifications Manufacturer Endress+Hauser


Instrument designation Cerabar T PMP 131

Application Measuring absolute and gauge pressure of gases, vapors and liquids

Function and system design Measuring principle


With analog output The process pressure acting upon the metallic
separating diaphragm of the sensor is transmitted to a
resistance bridge via a fluid. The change in the output
voltage of the bridge is proportional to the pressure
and can be measured directly.
With switch output The process pressure acting upon the metallic
separating diaphragm of the sensor is transmitted to a
resistance bridge via a fluid. A differential amplifier
creates a standard signal from the pressure-
proportional change in output voltage of the bridge. A
comparator with an adjustable deadband compares
this signal with the pre-set switch point and then
activates the power amplifier and the LED.
Design Analog output: pressure sensor is optionally supplied
with DIN 43650 A / ISO 4400 plug or cable
Switch output: pressure transmitter supplied with plug
DIN 43650 A / ISO 4400 (refer to page 3)

Input Measured variable Gauge or absolute pressure


Measuring ranges Maximum 6000 psi (400 bar), refer to ordering
information on page 6

Output Analog output 4 to 20 mA


Output signal 4 to 20 mA, loop powered
Load RB (Ω) ≤ (US - 12V) / 0.02 A (US = power supply)

Switch output PNP


Output signal Voltage (depends on power supply)
Output current Switch status ON, Ia ≤ 0.5A;
switch status OFF, Ia ≤ 1 mA
Power Maximum 6 W (current consumption 20 mA plus load)
Switch frequency Maximum 10 Hz
Input resistance/Input current PLC Ri ≤ 2 kΩ or Ii ≥ 10 mA
NOTE: To prevent electrical interference, inductive
loads (relays, contactors or solenoid valves) may only
be operated when directly connected to a protective
circuit (diode or capacitor).

Accuracy Terminal-based linearity inluding Analog output: ≤ 0.5% FS (limit point method to
hysteresis and reproducibility DIN IEC 770)
Accuracy Switch output: ≤ 1% FS for the switch point
Reproducibility Switch output: ≤ 0.5% FS for the switch output
Response time 2 to 5 ms (to reach 99.9% of output)
Effect of ambient temperature Analog output:
- Zero: typically 0.2%/10 K, maximum
0.5%/10 K of measuring span. Values are 0.1%/10 K
higher for measuring spans ≤ 90 psi (6 bar)
- Span: typically 0.2%/10 K, maximum 0.5%/10 K of
measuring span
Switch output:
- Typically 0.2%/10 K of measuring span
Long-term stability Typically 0.15% per year

4
Operating conditions Mounting conditions Any position, flush-mounted for process connection
G 1/2 (order code B), maximum torque for mounting,
354 in. lb. (40 Nm)

Environment
Normal operating temperature -13° to +158°F (-25° to +70°C)
Ex areas, -13° to +149°F (25° to +65°C)
Storage temperature -40° to +185°F (-40° t +85°C)
Climate class 4 Z with Z = 158°F (70°C) to VDI/VDE 3540
Ingress protection With plug, NEMA 4 (IP 65); with cable, NEMA 6P
(IP 68)
Vibrational resistance 4M5 to DIN EN 60721-3
Electromagnetic compatibility Interference emission to EN 61326 electrical device
B, interference immunity to EN 61326 appendix A
(industrial use) and NAMUR recommendation NE 21

Process
Normal process temperature -13° to +158°F (-25° to +70°C)
Process pressure limits Overload resistance, see Order Code, page 6
Vacuum resistance to 0.14 psia (10 mbarabs)

Mechanical construction Process connections 1/2” NPT (male), 304SS; G 1/2 (male), 304 SS;
G 1/4 (male), 304 SS; or G 1/2 (male) flush
diaphragm, 304 SS
Electrical connection Plug connection (ISO 4400), 1/2” NPT, NEMA 4
(IP 65); plug connection (ISO 4400), PG 11, IP 65;
cable, 16.4 ft. (5 m), NEMA 6P (IP 68)
Cable Outer covering, PUR, non-flammable to VDE 0472,
external diameter, 0.23” (5.8 mm). Internal wires,
4 x 24 AWG (0.22 mm2). External diameter of
air tube, 0.08” (2 mm).
Connection Plug to DIN 43650 A / ISO 4400, PA material

Materials for wetted parts


Process connection and housing 304 SS
Process diaphragm 316L SS
Fill fluid Silicone oil AK3

Power Power supply Analog output: non-hazardous, 12 to 30 VDC


Hazardous, no load voltage ≤ 26V; short-circuit
current, ≤ 100 mA; power consupmtion ≤ 0.8 W
Switch output: 18 to 32 VDC, current consumption
without load < 20 mA, with reverse polarity protection
Ripple Analog output, 5%; switch output, 10%

Certificates and approvals Analog output EEx ib IIC T6


CE mark By attaching the CE mark, Endress+Hauser confirms
that the instrument fulfills all the requirements of the
relevant EC directives.

Supplementary documentation Cerabar T System Information SI 035P/00/en


Cerabar T Operating Instructions KA 103P/00/a6
Cerabar T PMC 131 Technical Information TI 279P/24/ae
Cerabar T PMP 135 Technical Information TI 372P/24/ae
EMC test procedures Technical Information TI 241F/00/en

5
Ordering Information Cerabar T PMP 131
1 2 3 4 5
PMP 131 -

1 Version / cable entry / protection


A1 Plug (ISO 4400) / Pg 11 / IP 65
A2 Plug (ISO 4400) / 1/2” NPT / NEMA 4 (IP 65)
A3 16.4 ft (5 m) cable / NEMA 6P (IP 68)
99 Special version
2 Process connection / type / material
1 G 1/2 (male) / DIN 16 288 / 304 SS
2 1/2” MNPT, 1/4” FNPT / 304 SS
3 1/2” MNPT, 11 mm internal / 304 SS
4 G 1/4 (male) / DIN 16 288 / 304 SS
B G 1/2 (male) / DIN 3852-A flush diaphragm / 304 SS
9 Special version
3 Output signal, certificate
0 Analog 4 to 20 mA, 2-wire, standard
1 Analog 4 to 20 mA, 2-wire, EEx ib IIC T6
2 Switch output, PNP-Transistor, 3-wire (with plug only)
9 Special version
4 Accessories
1 None
9 Special version
5 Measuring range, units Overload
Gauge pressure (psi)
Q4H 0 to 15 psig 60 psi
Q4K 0 to 30 psig 150 psi
Q4N 0 to 50 psig 240 psi
Q4R 0 to 150 psig * 600 psi
Q4S 0 to 300 psig * 1500 psi
Q4T 0 to 500 psig * 2400 psi
Q4V 0 to 1000 psig * 3600 psi
Q70 0 to 1500 psig * 6000 psi
Q73 0 to 3000 psig * 9000 psi
Q74 0 to 6000 psig * 9000 psi
Absolute pressure (psia)
R4H 0 to 15 psia 60
R4K 0 to 30 psia 150 psi
R4N 0 to 50 psia 240 psi
R4R 0 to 150 psia 600 psi
R4S 0 to 300 psia 1500 psi
R4T 0 to 500 psia 2400 psi
R4V 0 to 1000 psia 3600 psi
R70 0 to 1500 psia 6000 psi
R73 0 to 3000 psia 9000 psi
R74 0 to 6000 psia 9000 psi
Gauge pressure (bar) (kPa, MPa)
A1G 0 to 1 bar 0 to 100 kPa 4 bar
A1H 0 to 1.6 bar 0 to 160 kPa 6.4 bar
A1N 0 to 2.5 bar 0 to 250 kPa 10 bar
A1Q 0 to 4 bar 0 to 400 kPa 16 bar
A1R 0 to 6 bar 0 to 600 kPa 24 bar
A1S 0 to 10 bar 0 to 1 MPa 40 bar
A1T 0 to 16 bar 0 to 1.6 MPa 64 bar
A1W 0 to 25 bar 0 to 2.5 MPa 100 bar
A1X 0 to 40 bar * 0 to 4 MPa * 160 bar
A1Z 0 to 60 bar * 0 to 6 MPa * 240 bar
A70 0 to 100 bar * 0 to 10 MPa * 400 bar
A71 0 to 160 bar * 0 to 16 MPa * 600 bar
A73 0 to 250 bar * 0 to 25 MPa * 600 bar
A74 0 to 400 bar * 0 to 40 MPa * 600 bar
Absolute pressure (bar) (kPa, MPa)
A2G 0 to 1 bar 0 to 100 kPa 4 bar
A2H 0 to 1.6 bar 0 to 160 kPa 6.4 bar
A2N 0 to 2.5 bar 0 to 250 kPa 10 bar
A2Q 0 to 4 bar 0 to 400 kPa 16 bar
A2R 0 to 6 bar 0 to 600 kPa 24 bar
A2S 0 to 10 bar 0 to 1 MPa 40 bar
A2T 0 to 16 bar 0 to 1.6 MPa 64 bar
A2W 0 to 25 bar 0 to 2.5 MPa 100 bar
A2X 0 to 40 bar 0 to 4 MPa 160 bar
A2Z 0 to 60 bar 0 to 6 MPa 240 bar
B70 0 to 100 bar 0 to 10 MPa 400 bar
B71 0 to 160 bar 0 to 16 MPa 600 bar
B73 0 to 250 bar 0 to 25 MPa 600 bar
B74 0 to 400 bar 0 to 40 MPa 600 bar
999 Special version

* Absolute pressure sensors

6
Dimensions
Version Version
Order code A1: plug with Pg 11 gland Order code A3: cable
Order code A2: plug with 1/2" NPT gland

2.05"
(52)
1.54"
(39)
2.13"
(54)
1.46"
(37)

1/2" NPT
or PG 11

L
L

2.72"
3.11"
(69)
(79)

∅ 1.02" ∅ 1.02"
(26) (26)

27 AF
Pressure Distance
rating L Pressure Distance
< 360 psi 4.96" rating L
(25 bar) (126 mm) < 360 psi 5.63"
> 580 psi 5.16" (25 bar) (143 mm)
(40 bar) (131 mm) > 580 psi 5.83"
(40 bar) (148 mm)

Order code 2: 1/2" MNPT Optional with process connection Order code 3: 1/2" MNPT Order code 4: G 1/4
1/4" FNPT Order code 1: G 1/2 11 mm female
L L L L

0.51"
0.98" 0.79" 0.59" 0.98" (13)
0.59" (20) (25)
(15) (25) (15)

1/4" 0.43" ∅ 0.19"


FNPT (11) 0.12" (5)
1/2" G 1/4
1/2" (3)
0.19" MNPT
MNPT
(5) G 1/2

Order code B: G 1/2 flush diaphragm


to DIN 3852-A-G 1/2

2.05"
(52)
1.54"
2.13" (39)
(54)
1.46"
(37)

1/2" NPT
or PG 11 5.27"
(134)

4.61"
(117) 2.76"
(70) 2.76"
(70)

∅ 1.02" ∅ 1.02"
(26) (26)
0.12"
(3)
27 AF

0.51"
(13)

G 1/2
Threaded hole
∅ 1.02"
(26) to DIN 3852-X-G 1/2
∅ 1.06"
(27) 0.098"
(2.5)
∅ 0.83"
(21)

0.55"
(14) 0.87"
(22)

Dimensions are in inches (mm)

7
For application and selection assistance,
in the U.S. call 888-ENDRESS

For total support of your installed base, 24 hours


a day, in the U.S. call 800-642-8737

Visit us on our web site, www.us.endress.com

United States Canada Mexico

Endress+Hauser, Inc. Endress+Hauser Endress+Hauser


2350 Endress Place Canada Ltd. Paseo del Pedregal No. 610
Greenwood, IN 46143 1440 Graham’s Lane Col. Jardines del Pedregal
Phone: (317) 535-7138 Unit 1, Burlington 01900, Mexico D.F.
888-ENDRESS ON, L7S 1W3 Mexico
FAX: (317) 535-8498 Phone: (905) 681-9292 Phone: (525) 568-2405
800-668-3199 FAX: (525) 568-7459
FAX: (905) 681-9444
Endress+Hauser
The Power of Know How

TI 291P/24/ae/02.03
© 2003 Endress+Hauser, Inc.