Вы находитесь на странице: 1из 12

G6C

PCB Power Relay

Miniature High Capacity Relays


with SPST-NO 10A and SPST-NO +
SPST-NC 8A
• SPST-NO 10A and SPST-NO + SPST-NC 8A for power switching and
output that satisfy the needs for space-saving.
• Small High-capacity Relays Compact: 20 × 15 × 10 mm (L × W × H).
• Low power consumption: 200 mW.
• Ultrasonically cleanable models is available.
• Exclusive P6C model for sockets is now available.

RoHS Compliant

■Model Number Legend ■Application Examples


G6C- @- @ @ @ @@- @- @-@- @ Ideal for output applications of control
1 2 3 4 5 6 7 8 9 equipments
G
6
1. Relay Function 6. Contact Material
C
None: Single-side stable None: Standard (Ag-alloy (Cd free))
U : Single-winding latching FD : AgSnIn Contacts
K : Double-winding latching (Suitable for DC inductive load
2. Contact Form with high inrush current)
11: SPST-NO (1a) 7. Approved Standards
21: SPST-NO (1a) + SPST-NC (1b) US: UL/CSA
3. Contact Type 8. Washability
1: Single None: Standard model
4. Enclosure rating (not compatible with ultrasonically
4: Fully sealed cleanable models)
7: Flux protection U : For ultrasonically cleanable
5. Terminal Shape 9. Mounting
P: PCB terminals None: Mounted directly to PCB
Socket mounting Terminals P6C : Mounted to Socket
C: Self-clinching PCB

1
G6C PCB Power Relay

■Ordering Information
●Standard Models (UL, CSA certified)
Relay Function Single-side stable Single-winding latching Double-winding latching Minimun
Enclosure Rated coil Rated coil Rated coil packing
Model Model Model unit
rating Contact form Terminals voltage voltage voltage
3 VDC 3 VDC 3 VDC
5 VDC 5 VDC 5 VDC
G6C-1117P-US 6 VDC G6CU-1117P-US − G6CK-1117P-US 6 VDC
12 VDC 12 VDC 12 VDC
Straight PCB
24 VDC 24 VDC 24 VDC
5 VDC 5 VDC −
SPST-NO (1a)
G6C-1117P-FD-US 12 VDC G6CU-1117P-FD-US 12 VDC G6CK-1117P-FD-US 12 VDC
24 VDC 24 VDC −
3 VDC − −
Self-clinching 5 VDC − −
G6C-1117C-US − G6CK-1117C-US
PCB 12 VDC − 12 VDC
24 VDC − 24 VDC
Flux 100 pcs/
3 VDC 3 VDC 3 VDC
protection tray
5 VDC 5 VDC 5 VDC
G6C-2117P-US 6 VDC G6CU-2117P-US 6 VDC G6CK-2117P-US 6 VDC
12 VDC 12 VDC 12 VDC
Straight PCB
24 VDC 24 VDC 24 VDC
5 VDC 5 VDC 5 VDC
G SPST-NO (1a) +
G6C-2117P-FD-US 12 VDC G6CU-2117P-FD-US 12 VDC G6CK-2117P-FD-US −
6 SPST-NC (1b)
24 VDC 24 VDC 24 VDC
C
3 VDC − 3 VDC
5 VDC 5 VDC 5 VDC
Self-clinching
G6C-2117C-US 6 VDC G6CU-2117C-US − G6CK-2117C-US −
PCB
12 VDC 12 VDC 12 VDC
24 VDC − 24 VDC

Relay Function Single-side stable Single-winding latching Double-winding latching Minimun


Enclosure Rated coil Rated coil Rated coil packing
Model Model Model unit
rating Contact form Terminals voltage voltage voltage
3 VDC 3 VDC 3 VDC
5 VDC 5 VDC 5 VDC
G6C-1114P-US 6 VDC G6CU-1114P-US 6 VDC G6CK-1114P-US 6 VDC
12 VDC 12 VDC 12 VDC
Straight PCB
24 VDC 24 VDC 24 VDC
5 VDC 5 VDC 5 VDC
SPST-NO (1a)
G6C-1114P-FD-US 12 VDC G6CU-1114P-FD-US 12 VDC G6CK-1114P-FD-US 12 VDC
24 VDC 24 VDC 24 VDC
3 VDC − 3 VDC
Self-clinching 5 VDC − 5 VDC
G6C-1114C-US G6CU-1114C-US G6CK-1114C-US
PCB 12 VDC 12 VDC 12 VDC
24 VDC − 24 VDC
Fully 100 pcs/
3 VDC 3 VDC 3 VDC
sealed tray
5 VDC 5 VDC 5 VDC
G6C-2114P-US 6 VDC G6CU-2114P-US 6 VDC G6CK-2114P-US 6 VDC
12 VDC 12 VDC 12 VDC
Straight PCB
24 VDC 24 VDC 24 VDC
5 VDC 5 VDC −
SPST-NO (1a) +
G6C-2114P-FD-US 12 VDC G6CU-2114P-FD-US 12 VDC G6CK-2114P-FD-US −
SPST-NC (1b)
24 VDC 24 VDC 24 VDC
3 VDC − −
5 VDC 5 VDC 5 VDC
Self-clinching
G6C-2114C-US 6 VDC G6CU-2114C-US − G6CK-2114C-US 6 VDC
PCB
12 VDC − 12 VDC
24 VDC − 24 VDC

Note. When ordering, add the rated coil voltage to the model number.
Example: G6C-1117P-US DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.

2
G6C PCB Power Relay

●Ultrasonically Cleanable Models (UL, CSA certified)


Relay Function Single-side stable Single-winding latching Double-winding latching Minimun
Enclosure Rated coil Rated coil Rated coil packing
Model Model Model unit
rating Contact form Terminals voltage voltage voltage
3 VDC − −
5 VDC 5 VDC 5 VDC
Straight PCB G6C-1114P-US-U 6 VDC G6CU-1114P-US-U − G6CK-1114P-US-U −
SPST-NO (1a) 12 VDC 12 VDC 12 VDC
24 VDC − 24 VDC
Self-clinching 12 VDC − −
G6C-1114C-US-U − − 100 pcs/
Fully sealed PCB 24 VDC − −
tray
5 VDC − 5 VDC
Straight PCB G6C-2114P-US-U 12 VDC − − G6CK-2114P-US-U 12 VDC
SPST-NO (1a) + 24 VDC − −
SPST-NC (1b) 5 VDC − −
Self-clinching
G6C-2114C-US-U 12 VDC − − − −
PCB
24 VDC − −
Note. When ordering, add the rated coil voltage to the model number.
Example: G6C-1114P-US-U DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.

●Connecting Sockets (Sold Separately)


Applicable relays Model Minimun packing unit G
G6C-2114P-US-P6C 6
G6C-2117P-US-P6C C
G6C-1114P-US-P6C
G6C-1117P-US-P6C
P6C-06P
G6CU-2114P-US-P6C
G6CU-2117P-US-P6C
G6CU-1114P-US-P6C 20 pcs/tube
G6CU-1117P-US-P6C
G6CK-2114P-US-P6C
G6CK-2117P-US-P6C
P6C-08P
G6CK-1114P-US-P6C
G6CK-1117P-US-P6C
Removal Tool P6B-Y1
1
Hold-down Clips P6B-C2
Note 1. Use the G6C-@@@@P-US-P6C to mount to a P6C Socket.
2. When using by combining sockets, the rated current will be 5A due to its rated switching current.

3
G6C PCB Power Relay

■Ratings
Coil: 1-Pole, Single-side Stable Type (Including models for ultrasonically cleanable)
Item Must operate Must release Max.
Rated Coil voltage voltage voltage Power
current resistance (V) (V) (V) consumption
(mA) (Ω) (mW)
Rated voltage % of rated voltage
3 VDC 67 45
5 VDC 40 125
160%
6 VDC 33.3 180 70% max. 10% min. Approx. 200
(at 23°C)
12 VDC 16.7 720
24 VDC 8.3 2,880

Coil: Single-winding Latching Type (Including models for ultrasonically cleanable)


Item Must set Must reset Max. Power consumption
Rated Coil voltage voltage voltage
current resistance (V) (V) (V) Set coil Reset coil
(mA) (Ω) (mW) (mW)
Rated voltage % of rated voltage
3 VDC 67 45
5 VDC 40 125
160%
6 VDC 33.3 180 70% max. 70% max. 200 200
(at 23°C)
12 VDC 16.7 720
24 VDC 8.3 2,880

Coil: Double-winding Latching Type (Including models for ultrasonically cleanable)


Item Rated current (mA) Coil resistance (Ω) Must set Must reset Max. Power consumption
G voltage voltage voltage
6 (V) (V) (V) Set coil Reset coil
Set coil Reset coil Set coil Reset coil
C (mW) (mW)
Rated voltage % of rated voltage
3 VDC 93.5 93.5 32.1 32.1
5 VDC 56.0 56.0 89.3 89.3
130%
6 VDC 46.7 46.7 129 129 70% max. 70% max. 280 280
(at 23°C)
12 VDC 23.3 23.3 514 514
24 VDC 11.7 11.7 2,056 2,056
Note 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The “Max. voltage” is the maximum voltage that can be applied to the relay coil.

Contact
Contact Form SPST-NO (1a) SPST-NO (1a) + SPST-NC (1b)
Inductive load Inductive load
Resistive load Resistive load
(cosφ = 0.4; L/R = 7 ms) (cosφ = 0.4; L/R = 7 ms)
Rated load
10 A (8 A) at 250 VAC 5 A (5 A) at 250 VAC 8 A (8 A) at 250 VAC 3.5 A (3.5 A) at 250 VAC
Item 10 A (10 A) at 30 VDC 5 A (5 A) at 30 VDC 8 A (8 A) at 30 VDC 3.5 A (3.5 A) at 30 VDC
Contact type Single
Contact material Ag-Alloy (Cd free)
Rated carry current 10 A (10 A) 8 A (8 A)
Max. switching voltage 380 VAC, 125 VDC
Max. switching current 10 A (10 A) 8 A (8 A)
Note. The values shown in parentheses ( ) are for -FD models only.

4
G6C PCB Power Relay

■Characteristics (Including models for ultrasonically cleanable)


Item Classification Single-side Stable Single-winding Latching Double-winding Latching
Contact resistance *1 30 mΩ max.
Operate (set) time 10 ms max.
Release (reset) time 10 ms max.
Min. set pulse width − 20 ms (at 23°C)
Min. reset pulse width − 20 ms (at 23°C)
Between coil and
1,000 MΩ min.
contacts
Between contacts of the
1,000 MΩ min.
Insulation same polarity
resistance *2 Between contacts of
1,000 MΩ min. (SPST-NO, SPST-NC)
different polarity
Between set and reset
− − 1,000 MΩ min.
coils
Between coil and
2,000 VAC 50/60Hz for 1min
contacts
Between contacts of the
1,000 VAC 50/60Hz for 1min
Dielectric same polarity
strength Between contacts of
2,000 VAC 50/60Hz for 1min (SPST-NO, SPST-NC)
different polarity
Between set and reset 250 VAC 50/60Hz for
− −
coils 1min
Vibration Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
resistance Malfunction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Shock Destruction 1,000 m/s2
Note. The given values are initial values.
resistance Malfunction 100 m/s2 *1. Measurement conditions: 5 VDC, 1 A, voltage
Mechanical 50,000,000 operations min. (at 18,000 operations/hr) drop method.
Durability
Electrical 100,000 operation min. (at 1,800 operations/hr under rated load) *2. Testing conditions: measured with a 500 VDC
Failure rate (P level) (reference value) *3 10 mA at 5 VDC megohmmeter (at 250 VDC between set/reset G
Ambient operating temperature -25°C to 70°C (with no icing or condensation) coil). 6
Ambient operating humidity 5% to 85% *3. This value was measured at a switching C
Weight Approx. 5.6 g frequency of 120 operations/min.

■Engineering Data
● Maximum Switching Capacity
G6C-1114@-US G6C-1114@-FD-US
G6C-1117@-US G6C-1117@-FD-US
Switching current (A)
Switching current (A)

50 50
30 30

AC resistive load AC resistive load


10 10
8
7
5 5

3 AC inductive 3
DC resistive load AC inductive
load 2 DC resistive load load
DC inductive load (cosφ = 0.4) (cosφ = 0.4)
1 (L/R = 7 ms) 1 DC inductive load
0.7 0.7 (L/R = 7 ms)
0.5 0.5

0.3 0.3
0.2 0.2

0.1 0.1
1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000
Switching voltage (V) Switching voltage (V)

G6C-2114@-US G6C-2114@-FD-US
G6C-2117@-US G6C-2117@-FD-US
Switching current (A)

Switching current (A)

50 50
30 30

AC resistive load AC resistive load


10 10
8 8
5 5
3 3
DC resistive load AC inductive
2 2 AC inductive
DC inductive load load load
(cosφ = 0.4) DC resistive load
1 (L/R = 7 ms) 1 (cosφ = 0.4)
0.7 0.7 DC inductive load
0.5 0.5 (L/R = 7 ms)
0.3 0.3
0.2 0.2

0.1 0.1
1 3 5 7 10 30 50 100 250 380 1,000 1 3 5 7 10 30 50 100 250 380 1,000
Switching voltage (V) Switching voltage (V)

5
G6C PCB Power Relay

● Durability
G6C-1114@-US, G6C-2114@-US G6C-1114@-FD-US, G6C-2114@-FD-US
G6C-1117@-US, G6C-2117@-US G6C-1117@-FD-US, G6C-2117@-FD-US

Durability (x 104 operations)


Durability (× 104 operations)

500 500
G6C-2114@-FD-US
300 300 G6C-2117@-FD-US
250 VAC resistive
G6C-1114@-FD-US
30 VDC resistive
G6C-1117@-FD-US
G6C-2114@-US
100 100 250 VAC resistive
G6C-2117@-US
250 VAC resistive G6C-1114@-US G6C-1114@
50 30 VDC resistive G6C-1117@-US 50
-FD-US
250 VAC resistive G6C-1117@
30 30 VDC resistive 30
-FD-US
30 VDC resistive

10 10
G6C-2114@-US G6C-1114@-US G6C-1114@-FD-US
5 G6C-2117@-US G6C-1117@-US 5 G6C-2114@-FD-US
250 VAC inductive G6C-2117@-FD-US G6C-1117@-FD-US
250 VAC inductive 250 VAC inductive
3 (cosφ = 0.4) 3 250 VAC inductive
(cosφ = 0.4) (cosφ = 0.4) (cosφ = 0.4)
30 VDC inductive 30 VDC inductive
(L/R = 7 ms) 30 VDC inductive 30 VDC inductive
(L/R = 7 ms) (L/R = 7 ms) (L/R = 7 ms)
1 1
0 1 2 3 4 5 6 7 8 9 10 11 0 1 2 3 4 5 6 7 8 9 10 11
Switching current (A) Switching current (A)

● Ambient Temperature vs. ● Ambient Temperature vs Must


Maximum Coil Voltage Operate and Must Release voltages
Must Operate and Must Release voltages (%)

100
Maximum coil voltage (%)

200
Sample: Must operate voltage
G6C-114P-US Must release voltage
180 Number of Relays: max.
80 5 pcs X

160 min.
G
6 140
60

C 130
120
40
max.
100 X
20 min.
80

60 0
10 20 23 30 40 50 60 70 80 90 -40 -20 0 20 40 60 80
Ambient temperature (°C) Ambient temperature (°C)
Note. The maximum coil voltage refers to the
maximum value in a varying range of
operating power voltage, not a continuous
voltage.
● Shock Malfunction ● Magnetic Interference (between Relays)
Energized De-energized
Change rate on the basis of rated value (OV) (%)

Y Y 3
(a contact) 600 (b contact) 600

2
400 400
X Z X Z
600 600 600 600 1
200 400 200 400 max.
400 400
200 200 200 200 X
0 min.
200 200
200 200 400 l2
200 200 Sample
500
400 600 400 600 -1
Z' X' Z' X' l1
600 400 600 400
Shock direction
-2
X X'
600 600 Y
Y' Unit: m/s2 Y' Unit: m/s2 Z (Mounting pitch)
-3
Z' Initial l1=2.54a l1=5.08a l1=7.62a
Y' l2=5.08a l2=7.62a l2=10.16a
(coil)
Sample: G6C-2114P-US DC24V
Number of Relays: 6 pcs
Test conditions: Shock is applied in ±X, ±Y, and ±Z
directions three times each with without energizing the
Relays to check the number of malfunctions.
Requirement: 100 m/s2

6
G6C PCB Power Relay

■Dimensions
Flux Protection Model
PCB Mounting Holes Terminal Arrangement/
(Straight PCB) (Bottom View) Internal Connections
20 max. 15 max.
G6C-@117P (-FD) -US (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)
1-pole
10 max. 2.54
0.3 (9.9)* Four, 1.1-dia. holes
1-pole
2.54
3.5
1 3 4
0.5 −
0.65<0.7> 0.9<1.0> <0.4>
0.9<1.0>

10.16 1.11 10.16


7.62 +
(2.4) 8
* Average value
Dimensions in pointed brackets < > are
for the Relay mounted to Socket (-P6C). 10.16 7.62
(1.1)

Flux Protection Model


2-pole
(Self-clinching PCB) 2.54
Six, 1.1-dia. holes
G6C-@117C-US 20 max. 15 max.
2-pole
(19.9)* (14.9)* 2.54
1 3 4

10 max.
0.3 (9.9)*

3.2 3.5 +
(0.8)* (2.4) 8 6 5
(1.0)*
0.65 0.9 0.5
0.9 Note: Check carefully the coil
10.16 1.11 10.16
7.62
10.16 7.62
(1.1) polarity of the Relay.
G
* Average value
6
C
Fully Sealed Model PCB Mounting Holes Terminal Arrangement/
20 max. 15 max. 1-pole (Bottom View) Internal Connections
(Straight PCB) (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)
G6C-@114P (-FD) -US 2.54
Four, 1.1-dia. holes
10 max. 1-pole
0.3 (9.9)* 2.54
1 3 4

3.5

0.65<0.7> 0.9<1.0> 0.5


0.9<1.0> <0.4>
+
(2.4) 8
10.16 1.11 10.16
7.62
* Average value 10.16 7.62
Dimensions in pointed brackets < > are (1.1)
for the Relay mounted to Socket (-P6C).
2-pole
Fully Sealed Model
2.54
(Self-clinching PCB) 20 max. 15 max. Six, 1.1-dia. holes
2-pole
(19.9)* (14.9)*
G6C-@114C-US 2.54
1 3 4
10 max. −
0.3 (9.9)*

3.2 3.5 +
(0.8)* (2.4)
(1.0)* 8 6 5
0.65 0.9 0.5
0.9 Note: Check carefully the coil
10.16 1.11 10.16
7.62 10.16 7.62 polarity of the Relay.
* Average value (1.1)

Note: Orientation marks are indicated as follows:

7
G6C PCB Power Relay

Flux Protective
PCB Mounting Holes Terminal Arrangement/
Single-winding Latching Model (Bottom View) Internal Connections
(Straight PCB) 20 max. 15 max. Tolerance: ±0.1 (Bottom View)
(19.9)* (14.9)*
G6CU-@117P (-FD) -US 1-pole
10 max. 2.54
0.3 (9.9)* Four, 1.1-dia. holes
1-pole
2.54
3.5 1 3 4
− +
0.65<0.7> 0.9<1.0> 0.5
<0.4>
0.9<1.0> SR

10.16 1.11 10.16 + −


7.62 (2.4) 8
* Average value
S: Set coil
Dimensions in pointed brackets < > 10.16 7.62
R: Reset coil
are for the Relay mounted to Socket (-P6C). (1.1)

Flux Protective 2-pole


Single-winding Latching Model 2.54
(Self-clinching PCB) 20 max. 15 max.
Six, 1.1-dia. holes
2-pole
G6CU-@117C-US (19.9)* (14.9)* 2.54
1 3 4
− +
10max.
0.3 (9.9)* SR

3.2 + −
3.5 (2.4) 8 6 5
(0.8)*
(1.0)*
0.65 0.9 0.5
0.9 Note: Check carefully the coil
10.16 1.11 10.16 10.16 7.62
7.62 (1.1)
polarity of the Relay.
G * Average value
6
C Fully Sealed Model PCB Mounting Holes Terminal Arrangement/
(Bottom View) Internal Connections
Single Latching Models 20 max. 15 max. Tolerance: ±0.1 (Bottom View)
(Straight PCB) (19.9)* (14.9)*
1-pole
G6CU-@114P (-FD) -US 2.54
10 max. Four, 1.1-dia. holes
0.3 (9.9)* 1-pole
2.54
1 3 4
3.5 − +
0.5
0.65<0.7> 0.9<1.0> <0.4> SR
0.9<1.0>
+ −
10.16 1.11 10.16 (2.4) 8
7.62
* Average value S: Set coil
Dimensions in pointed brackets < > are 10.16 7.62 R: Reset coil
(1.1)
for the Relay mounted to Socket (-P6C).

Fully Sealed Model


Single Latching Models 2-pole
(Self-clinching PCB) 2.54
Six, 1.1-dia. holes
G6CU-@114C-US 20 max. 15 max. 2-pole
(19.9)* (14.9)* 2.54
1 3 4
− +
10 max.
0.3 (9.9)*
SR

3.2 + −
3.5 (2.4) 8 6 5
(0.8)*
(1.0)*
0.65 0.9 0.5
0.9 Note: Check carefully the coil
10.16 1.11 10.16 10.16 7.62
7.62 polarity of the Relay.
(1.1)
* Average value

Note: Orientation marks are indicated as follows:

8
G6C PCB Power Relay

Flux Protective
Double-winding Latching Model
PCB Mounting Holes Terminal Arrangement/
(Straight PCB) 20 max. 15 max. (Bottom View) Internal Connections
G6CK-@117P (-FD) -US (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)
1-pole
10 max. 2.54
0.3 (9.9)* Six, 1.1-dia. holes
1-pole
2.54
0.9 3.5
1 2 3 4
<1.0> − −
0.65<0.7> 0.5
0.9<1.0> 0.9 <0.4>
<1.0> S R
10.16 1.11 10.16 + +
7.62 (2.4) 8 7
* Average value
S: Set coil
Dimensions in pointed brackets < > are
2.54 7.62 7.62 R: Reset coil
for the Relay mounted to Socket (-P6C). (1.1)

Flux Protective 2-pole


2.54
Double-winding Latching Model Eight, 1.1-dia. holes
2-pole
(Self-clinching PCB) 20 max. 15 max. 2.54
G6CK-@117C-US (19.9)* (14.9)* 1 2 3 4
− −

10 max. S R
0.3 (9.9)*
+ +
(2.4) 8 7 6 5
3.2 3.5 (0.8)*
0.9 (1.0)*
0.65 0.9 0.5 7.62 7.62 Note: Check carefully the coil
0.9 polarity of the Relay.
10.16 1.11 10.16 2.54 (1.1)
7.62
* Average value G
6
C
Fully Sealed
Double-winding Latching Model
PCB Mounting Holes Terminal Arrangement/
(Straight PCB) 20 max. 15 max. (Bottom View) Internal Connections
G6CK-@114P (-FD) -US (19.9)* (14.9)* Tolerance: ±0.1 (Bottom View)

10 max. 1-pole
0.3 (9.9)*
2.54
Six, 1.1-dia. holes
3.5
1-pole
0.9 2.54
<1.0>
0.65<0.7> 0.5 1 2 3 4
0.9<1.0>
0.9 <0.4> − −
<1.0>
10.16 1.11 10.16 S R
7.62
* Average value + +
(2.4) 8 7
Dimensions in pointed brackets < > are
for the Relay mounted to Socket (-P6C).
7.62 7.62 S: Set coil
2.54 (1.1) R: Reset coil
Fully Sealed
Double-winding Latching Model
2-pole
(Self-clinching PCB) 2.54
G6CK-@114C-US 20 max. 15 max.
Eight, 1.1-dia. holes
2-pole
(19.9)* (14.9)* 2.54
1 2 3 4
− −
10 max.
0.3 (9.9)*
S R

3.2 3.5 + +
(0.8)* (2.4) 8 7 6 5
0.9 (1.0)*
0.65 0.9 0.5
0.9 Note: Check carefully the coil
10.16 1.11 10.16 7.62 7.62
7.62
2.54 (1.1)
polarity of the Relay.
* Average value

Note: Orientation marks are indicated as follows:

9
G6C PCB Power Relay

■Connecting Sockets Dimensions


Socket for single-winding latching/single-side a table Models
P6C-06P

23.2max. PCB Mounting Holes


(23)* (BOTTOM VIEW)
Tolerance: ±0.1 mm

15max. 3.1 2.54 Six, 1.1-dia. holes


(14.9)*

2.54
(2.4)
10.8max.
(10.6)* 7.5

3.5
(2.61) 10.16 7.62
0.8 0.4
* Average value 10.16 7.62
10.16±0.1

Socket for double-winding latching Models


P6C-08P
23.2max.
(23)* PCB Mounting Holes
(BOTTOM VIEW)
Tolerance: ±0.1 mm
15max.
G (14.9)*
3.1
2.54 Eight, 1.1-dia. holes
6
C
2.54
10.8max. (2.4)
(10.6)* 7.5

3.5

0.8 0.4 (2.61) 7.62 7.62


* Average value 2.54 7.62 7.62 2.54
10.16±0.1

Note: Orientation marks are indicated as follows:

10
G6C PCB Power Relay

■Removal Tool ■Hold-down Clips


P6B-Y1 P6B-C2

■Approved Standards
●The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in
this catalog.
UL Recognized (File No. E41643)

CSA Certified (File No. LR31928)

Number of Number of test


Model Coil ratings Contact ratings
poles operations
10 A, 250 VAC (General use) 80°C
10 A, 30 VDC (Resistive) 80°C
1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C 6,000
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models) G
1
530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C 6
6,000
43.2 VA, 30 VDC (Pilot Duty) 80°C C
30,000
12 LRA, 2.2 FLA, 30 VDC 80°C
1,000 (-FD Models)
G6C ( ) 3 to 24 VDC
8 A, 250 VAC (General use) 80°C
8 A, 30 VDC (Resistive) 80°C
1/6 HP 125 VAC, 1/4 HP, 125 VAC 80°C 6,000
1/3 HP 250 VAC, 1/4 HP, 250 VAC 80°C
600 W, 120 VAC, (Tungsten) 80°C (excluding -FD Models)
2
530 VA, 20 to 265 VAC Max 2A (Pilot Duty) 80°C
6,000
43.2 VA, 30 VDC (Pilot Duty) 80°C
30,000
12 LRA, 2.2 FLA, 30 VDC 80°C
1,000 (-FD Models)

EN/IEC, VDE Certified (Certificate No. 40014439)


Number of Approved switching
Model Coil ratings Contact ratings
poles operations
10 A, 250 VAC (cosφ = 1) 40°C
1 3, 5, 6, 12, 24 VDC
5 A, 250 VAC (cosφ = 0.4) 40°C
G6C ( ) 20,000
• Single-stable: 7 A, 250 VAC (cosφ = 1) 40°C
2
3, 5, 6, 12, 24 VDC 3.5 A, 250 VAC (cosφ = 0.4) 40°C

EN/IEC, TÜV Certified (Registration No. R50158249)


Number of Approved switching
Model Coil ratings Contact ratings
poles operations
10 A, 250 VAC (cosφ = 1) 40°C
1 • Single-stable: 5 A, 250 VAC (cosφ = 0.4) 40°C
3, 5, 6, 12, 24 VDC 10 A, 30 VDC (L/R = 0 ms) 40°C
G6C ( ) 20,000
• Latching: 8 A, 250 VAC (cosφ = 1) 40°C
2 3, 5, 6, 12, 24 VDC 3.5 A, 250 VAC (cosφ = 0.4) 40°C
8 A, 30 VDC (L/R = 0 ms) 40°C

11
G6C PCB Power Relay

■Precautions
●Please refer to “PCB Relays Common Precautions” for correct use.

Correct Use
●Mounting ●Sockets ●Using SPDT contact of the
• Do not reverse the polarity of the coil SPST-NO+SPST-NC Relay
(+, −). 17 mm max. for sockets
• Do not construct a circuit so that
• When mounting more than two relays 7.5 mm overcurrent and burning occur if the
side by side, keep the gap between NO, NC and SPDT contacts are short-
Relays as shown below to ensure a circuited with the SPST-NO+SPST-NC
• When mounting the Relay, make sure Relay. Arcing may generate short-
good heat dissipation. It may result in
to insert the Relay terminals circuiting between contacts if there is
malfunction if heat is not dissipated
perpendicularly and correctly into the short-circuiting because of conversion
smoothly from the Relay.
socket contact pin. to the MBB contact caused by
• Hold-down clips (for mounting and asynchronous operation of the NO and
2.54 mm ×
3 pitch min. removal) are also available. NC contacts, the interval between the
between
terminals • The P6C model has a flux-resistant NO and NC contacts is small, or a
construction. Do not wash it down with large current is left open.
water.
2.54 mm × 2 pitch min. between terminals ●Other precautions
• The max. carry current of sockets is 5A.
• This Relay is a Power Relay which is
• Not applicable to the self-clinching type.
G suitable for power load switching. Do
6 ●Double-winding Latching Circuit
C not use the G6C for signal purposes
• It is recommended to perform wiring of such as micro load switching under
No.1 and No.2 of the negative (-) 10 mA.
terminal as COM wiring, in order to
improve the operation stability for
Double-winding Latching.
(+)

+ 8 + 7

S R

− 1 − 2

COM

Please check each region's Terms & Conditions by region website.

OMRON Corporation
Electronic and Mechanical Components Company

Regional Contact
Americas Europe
https://www.components.omron.com/ http://components.omron.eu/
Asia-Pacific China
https://ecb.omron.com.sg/ https://www.ecb.omron.com.cn/
Korea Japan
https://www.omron-ecb.co.kr/ https://www.omron.co.jp/ecb/

© OMRON Corporation 2007-2018 All Rights Reserved. Cat. No. K018-E1-11


In the interest of product improvement, specifications are subject to change without notice. 0318(0207)(O)

12

Вам также может понравиться