Cyl. No.

5 6 7 8 9
A 875 Cylinder distance
B 1240 Distance from crankshaft centre line to foundation
B1 575 Recommended floor level for safe and easy access to crankcase
C 2755 2815 2845 2890 3005 The dimension includes a cofferdam of 600 mm and must fulfil minimum height to tank top according to classification rules
6850 6850 6850 - 6900 MAN Diesel TCA
D* - 6637 - - - ABB A100-L/200-L Dimensions according to turbocharger choice at nominal MCR
- 6800 - - - Mitsubishi MET
3630 4030 4167 4442 4967 MAN Diesel TCA
E* 3590 3959 4096 4517 4897 ABB A100-L/200-L Dimensions according to turbocharger choice at nominal MCR
3524 3934 4080 4346 4851 Mitsubishi MET
F See text See drawing: ‘Engine Top Bracing’, if top bracing fitted on camshaft side
MAN Diesel TCA
G 2900 ABB A100-L/200-L The required space to the engine room casing includes mechanical top bracing
Mitsubishi MET
H1 * 9875 Minimum overhaul height, normal lifting procedure
H2 * 9125 Minimum overhaul height, reduced height lifting procedure
H3 * 8850 The minimum distance from crankshaft centre line to lower edge of deck beam, when using MAN B&W Double Jib Crane
I 1675 Length from crankshaft centre line to outer side bedplate
J 350 Space for tightening control of holding down bolts
K See text K must be equal to or larger than the propeller shaft, if the propeller shaft is to be drawn into the engine room
nd
L* 6073 6948 7823 8698 9573 Minimum length of a basic engine, without 2 order moment compensators.
M ≈ 800 Free space in front of engine
N 3996 Distance between outer foundation girders
O 2150 Minimum crane operation area
P See text See drawing: 'Crane beam for Turbocharger' for overhaul of turbocharger
1616 1583 1491 - 1515 MAN Diesel TCA
Q - 1433 - - - ABB A100-L/200-L Dimensions according to turbocharger choice at nominal MCR
- 1533 - - - Mitsubishi MET
R
S Required crane coverage area and hook travelling width for turbocharger maintenance and overhaul to be supplied by
See text
T turbocharger maker
U
V 0°, 15°, 30°, 45°, 60°, 75°, 90° Maximum 30° when engine room has minimum headroom above the turbocharger
Y 3557 Space for water mist catcher overhaul.
Z 3977 Space for air cooler element overhaul.

Date Des. Chk. A.C. Revision change Chg. Not. Rev.

03
* 20161011 DFA OLS X2 G, H1, H2 and H3 corrected. 124039
02
01
 The min. engine room crane height is ie. dependent on the choice of crane,
20160622 DFA OLS 00
see the actual heights “H1”, “H2” or “H3”.
Basic Standards (MBD SB) Suppl. Drawing No.
 The min. engine room height is dependent on “H1”, “H2”, “H3” or “E+D”. EN21F-m Tolerances EN21C Surf. Roughness 5177819-6
 Max. length of engine see the engine outline drawing.
Material / Blank: Final User Material: Mass (Kg)
 Length of engine with PTO see corresponding space requirement.
Scale: Size: Product Type: Page No.: Projection:

A3 S50ME-C9.5 T/C aft. 1 (1) MAN Diesel


Info. No.: Item Name: Item Id.:

Copyright  2016 MAN Diesel & Turbo, branch of MAN Diesel & Turbo SE Germany, registered with the Danish Business Authority
under CVR-no. 31611792 (referred to as “MAN Diesel & Turbo”).
386600 Engine space requirement 5751039-7
This drawing is the sole property of MAN Diesel & Turbo, it must be treated as confidential by any party to whom it has been Final User Info No.: Final User Description: Final User Ident. No.:
submitted by MAN Diesel & Turbo, and it is not to be disclosed or transferred to any third party without the specific, prior written