MTU ONSITE ENERGY

DIESEL AND GAS GENERATOR SETS


contents combining our resources
to supply you with
dependable energy:
anytime. anywhere.
04 Rating definitions for diesel and gas 34 Continuous/Peak, Prime Power (3B) – Diesel MTU Onsite Energy is one of the core brands of Our product portfolio covers diesel generator sets up
generator sets 44 Continuous/Peak, Prime Power (3B) – Gas Rolls-Royce Power Systems, which is a world-leading to 3,250 kW, gas-powered cogeneration systems up
08 Standard Backup, Standby Power (3D) – Diesel provider of high- and medium-speed diesel and gas to 2,500 kW, furthermore medium-speed engines for
46 Continuous/Peak,
engines, complete drive systems, distributed energy land-based energy solutions up to 9,300 kWe as part
16 Standard Backup, Standby Power (3D) – Gas Grid Stability Power (3G) – Diesel
systems and fuel injection systems for the most of the Rolls-Royce Power Systems product portfolio.
18 Standard Backup, 48 Container – Diesel demanding environments.
Standby Power with overload (3E) – Diesel 50 Enclosures – Diesel More than 60 years of power generation systems
20 Mission Critical, 56 Power Modules – Diesel MTU Onsite Energy offers complete power system expertise and over a century of diesel engine
Data Center Continuous Power (3F) – Diesel solutions: from standard backup to mission critical engineering experience have enabled us to provide
58 Power Modules – Gas
24 Mission Critical, power to continuous and peak power, to combined complete solutions all over the globe.
60 Classifications for Data Centers – heat and cooling. We also provide a full line of We continue to develop sustainable alternatives,
Mission Critical Power (3H) – Diesel
according to Uptime Institute service products to help you get the most from your with systems that produce greener energy from
26 Continuous/Peak,
61 Footnotes equipment. climate-neutral, regenerative fuels, such as
Continuous Power (3A) – Diesel
62 Website combined heat and power (CHP) plants.
28 Continuous/Peak, Customers around the world trust us to provide
Continuous Power (3A) – Gas 63 Local Support
reliable power for a wide range of applications.

2 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 3


rating definitions for
diesel and GAS
generator sets

Standard Backup Continuous/Peak


Standby Power (3D) Continuous Power + CHP (3A)
The application group “Standby Power” (3D) provides classical backup The application group “Continuous Power” (3A) applies to installations
power. This rating applies to installations served by a reliable utility where one or several generator sets serve as utility. At constant or
source. The standby ratings are applicable to varying loads for the varying load, the number of generator set operating hours is unlimited.
duration of a power outage.

Standby Power with Overload (A) (3E) Prime Power (3B)


The application group “Standby Power with Overload” (3E) provides The application group “Prime Power” (3B) applies to installations where
classical standby power comparable to the application group 3D utility power is unavailable or unreliable. At varying load, the number
(“Standby Power”). The difference is that this application group offers a of generator set operating hours is unlimited.
10% overload capability to cover for e.g. voltage variations or peak loads.

Grid Stability Power (A) (3G)


Mission Critical The application group “Grid Stability Power” (3G) is focused on
Data Centre Continuous Power (3F) providing additional short-term power to the grid (peak shaving). This
The application group “Data Centre Continous Power” (3F) is especially application becomes relevant whenever renewable power sources like
for the use in data centers as emergency standby units. “Data Centre solar or wind are used that might not always be able to provide the full
Continous Power” offers an economic and customer friendly solution to power demand for example during peak load times.
comply to the Uptime Institute Tier III and Tier IV standards.

Mission Critical Power (A) (3H)


The application group “Mission Critical Power” (3H) is designed for the
power supply when lives or huge economic losses are at risk. Especially
for the use in hospitals, health care facilities, governmental and public
buildings and in infrastructure. MTU Onsite Energy focuses on the
highest reliability and availability of power.

* The Uptime Institute is a pioneer in creating and operating knowledge communities


for improving uptime effectiveness in data center facilities and information technology
organizations.

4 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 5


rating definitions
Overview

Standard Backup Continuous/Peak


Standby Power (3D) MTU Onsite Energy ISO 8528-1 (ESP) Continuous Power (3A) MTU Onsite Energy ISO 8528-1 (COP)
Load variable variable Load constant constant
Load factor ≤ 85 % ≤ 70 % Load factor ≤ 100 % ≤ 100 %
10 % overload (ICXN) no not specified 10 % overload (ICXN) Gas: no not specified
Max. operating hours (per year) 500  h 200  h Diesel: yes
Uptime compliant Tier I & Tier II not specified Max. operating hours (per year) unlimited unlimited

Prime Power (3B) MTU Onsite Energy ISO 8528-1 (PRP)


Standby Power MTU Onsite Energy ISO 8528-1 (ESP) Load variable variable
with Overload (A) (3E) Load factor ≤ 75 % ≤ 70 %
Load variable variable 10 % overload (ICXN) yes not specified
Load factor ≤ 85 % ≤ 70 % Max. operating hours (per year) unlimited unlimited
10 % overload (ICXN) yes not specified
Max. operating hours (per year) 500 h 200 h Grid Stability Power (A) (3G) MTU Onsite Energy ISO 8528-1 (LTP)
Uptime compliant Tier I & Tier II not specified Load continuous continuous
Load factor ≤ 100 % ≤ 100 %
Mission Critical 10 % overload (ICXN) yes not specified
Data Center Continuous MTU Onsite Energy ISO 8528-1 Max. operating hours (per year) 1000 h; 500 h with 100% load 500 h
Power (3F) w/o interruption
Load continuous n.a.
Load factor ≤ 100 % n.a.
10 % overload (ICXN) yes n.a.
Max. operating hours (per year) unlimited (B) n.a.
Uptime compliant Tier III & Tier IV n.a.

Mission Critical MTU Onsite Energy ISO 8528-1 (ESP)


Power (A) (3H)
Load variable variable
Load factor ≤ 85 % ≤ 70 %
10 % overload (ICXN) yes not specified
Max. operating hours (per year) 1000 h 200 h

6 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 7


Standard Backup – Diesel Generator Sets

Standard Backup - 3D
Standby Power (3D) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type

50Hz - Diesel
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
6300 kV (3 Phase)
6600 kV (3 Phase)
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


380V (3 Phase)

EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
CE / IEC
ORDE
kWe kWe

25 33 (4) x x x x x x x x x F32 AM 1A A2A MTU 4R0080 DS33


MTU 0080/0113 DS

28 45 (4) x x x x x x x x x F32 SM 1A A2A MTU 4R0080 DS45


37 55 (4) x x x x x x x x x F32 TM 1A A2A MTU 4R0080 DS55
54 63 (4) x x x x x x x x x NEF45 SM 1A A2A MTU 4R0113 DS63
87 80 (4) x x x x x x x x x NEF45 SM 2A A2A MTU 4R0113 DS80
122 94 (4) x x x x x x x x x NEF45 SM 5 A2A MTU 4R0113 DS94
244 305 (4) x x x x x x x x x x x x x 6R 1600 G70F A2A MTU 6R1600 DS300
MTU 1600 DS

264 330 (4) x x x x x x x x x x x x x 6R 1600 G80F A2A MTU 6R1600 DS330


320 400 (4) x x x x x x x x x x x x x 8V 1600 G70F A2A MTU 8V1600 DS400
356 445 (4) x x x x x x x x x x x x x 8V 1600 G80F A2A MTU 8V1600 DS440
400 500 (4) x x x x x x x x x x x x x 10V 1600 G70F A2A MTU 10V1600 DS500
448 560 (4) x x x x x x x x x x x x x 10V 1600 G80F A2A MTU 10V1600 DS560
528 660 (4) x x x x x x x x x x x x 12V 1600 G70F A2A MTU 12V1600 DS660
584 730 (4) x x x x x x x x x x x x 12V 1600 G80F A2A MTU 12V1600 DS730
680 850 x x x x x x x x x x 12V 2000 G65 A2A MTU 12V2000 DS850
MTU 2000 DS-G05

712 890 x x x x x x x x x x 12V 2000 G65TB W2A MTU 12V2000 DS890


800 1000 x x x x x x x x x x 16V 2000 G25 A2A MTU 16V2000 DS1000
840 1050 x x x x x x x x x x 16V 2000 G25TB W2A MTU 16V2000 DS1050
880 1100 x x x x x x x x x x 16V 2000 G65 A2A MTU 16V2000 DS1100
912 1140 x x x x x x x x x x 16V 2000 G65TB W2A MTU 16V2000 DS1140
1000 1250 (3) x x x x x x x x x x 18V 2000 G65 A2A MTU 18V2000 DS1250
1032 1290 x x x x x x x x x x 18V 2000 G65TB W2A MTU 18V2000 DS1290
660 825 x x x x x x x x x x x x x x x 12V 2000 G76F A2A MTU 12V2000 DS825
MTU 2000 DS-G06

800 1010 x x x x x x x x x x x x x 12V 2000 G86F A2A MTU 12V2000 DS1000


880 1100 x x x x x x x x x x x x x x x 16V 2000 G76F A2A MTU 16V2000 DS1100
1000 1250 x x x x x x x x x x x x x 16V 2000 G86F A2A MTU 16V2000 DS1250
1120 1400 x x x x x x x x x x x x x x x x x x x 18V 2000 G76F A2A MTU 18V2000 DS1400
1360 1700 x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650
MTU 4000 DS

1440 1800 x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1600 2000 x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000
1840 2300 x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1920 2600 x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2160 2700 x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650
2520 3200 x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2600 3400 x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200
8 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 9
Standard Backup – Diesel Generator Sets

Standard Backup - 3D
Standby Power (3D) – 50 Hz / 1500 rpm – North and Latin America

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type

50Hz - Diesel
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


3300 V (3 Phase)
220 V (1 Phase)
220 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


CE compliant
EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
ORDE
kWe kVA
MTU 0096 DS

24 30 x x x x x x x x x x 3029 TFG89 TC only MTU 3R0096 DS34


32 40 x x x x x x x x x x 4045 TF280 TC only MTU 3R0096 DS44
40 50 x x x x x x x x x x 4045 HF280 TC only MTU 3R0096 DS55
71 89 x x x x x x x x x x x x 4R 924 G60F A2A MTU 4R0120 DS90
MTU 0120 DS

89 111 x x x x x x x x x x x x 4R 924 G70F A2A MTU 4R0120 DS110


111 139 x x x x x x x x x x x x 4R 924 G80F A2A MTU 4R0120 DS140
134 167 x x x x x x x x x x x x 6R 924 G60F A2A MTU 6R0120 DS165
160 200 x x x x x x x x x x x x 6R 924 G70F A2A MTU 6R0120 DS200
178 222 x x x x x x x x x x x x 6R 924 G80F A2A MTU 6R0120 DS220
240 300 x x x x x x x x x 6R 1600 G70F A2A MTU 6R1600 DS300
MTU 1600 DS

264 330 x x x x x x x x x 6R 1600 G80F A2A MTU 6R1600 DS330


320 400 x x x x x x x x x 8V 1600 G70F A2A MTU 8V1600 DS400
352 440 x x x x x x x x x 8V 1600 G780F A2A MTU 8V1600 DS440
400 500 x x x x x x x x x 10V 1600 G70F A2A MTU 10V1600 DS500
440 550 x x x x x x x x x 10V 1600 G80F A2A MTU 10V1600 DS550
520 650 x x x x x x x x x 12V 1600 G70F A2A MTU 12V1600 DS650
572 715 x x x x x x x x x 12V 1600 G80F A2A MTU 12V1600 DS715
1120 1400 x x x x x x x x x x 18V 2000 G76F A2A MTU 18V2000 DS1400
MTU 2000 DS

10 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 11


Standard Backup – Diesel Generator Sets

Standard Backup - 3D
Standby Power (3D) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type

60Hz - Diesel
output (1) compliant variant (3)

240 V Re-connectable (1Ph.)


240 V Dedicated (1Phase)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

30 38 x x x x x x x x x x x x x 3029 TFG89 TC only MTU 3R0096 DS30


MTU 0096/0113 DS

35 44 x x x x x x x x x x x x x x 4045 TF280 TC only MTU 4R0113 DS35


40 50 x x x x x x x x x x x x x x 4045 TF280 TC only MTU 4R0113 DS40
50 63 x x x x x x x x x x x x x x 4045 TF280 TC only MTU 4R0113 DS50
60 75 x x x x x x x x x x x x x x 4045 HF280 A2A MTU 4R0113 DS60
80 100 x x x x x x x x x x x x x x 4045 HF285 A2A MTU 4R0113 DS80
100 125 x x x x x x x x x x x x x x 4045 HF285 A2A MTU 4R0113 DS100
125 156 x x x x x x x x x x x x x x 4045 HF285 A2A MTU 4R0113 DS125
150 188 x x x x x x x x x x x x x x 6068 HF285 A2A MTU 6R0113 DS150
180 225 x x x x x x x x x x x x x x 6068 HF485 A2A MTU 6R0113 DS180
200 250 x x x x x x x x x x x x x x 6068 HF485 A2A MTU 6R0113 DS200
80 100 x x x x x x x x x x x x x 4R 924 G60S A2A MTU 4R0120 DS80
MTU 0120 DS

100 125 x x x x x x x x x x x x x 4R 924 G70S A2A MTU 4R0120 DS100


125 156 x x x x x x x x x x x x x 4R 924 G80S A2A MTU 4R0120 DS125
150 188 x x x x x x x x x x x x x 6R 926 G60S A2A MTU 6R0120 DS150
180 225 x x x x x x x x x x x x x 6R 926 G70S A2A MTU 6R0120 DS180
200 250 x x x x x x x x x x x x x 6R 926 G80S A2A MTU 6R0120 DS200
230 288 x x x x x x x x x x x x 6R 1600 G70S A2A MTU 6R1600 DS230
MTU 1600 DS

250 313 x x x x x x x x x x x x 6R 1600 G70S A2A MTU 6R1600 DS250


275 344 x x x x x x x x x x x x 6R 1600 G70S A2A MTU 6R1600 DS275
300 375 x x x x x x x x x x x x 6R 1600 G80S A2A MTU 6R1600 DS300
350 438 x x x x x x x x x x x x 8V 1600 G70S A2A MTU 8V1600 DS350
400 500 x x x x x x x x x x x x 8V 1600 G80S A2A MTU 8V1600 DS400
450 563 x x x x x x x x x x x x 10V 1600 G70S A2A MTU 10V1600 DS450
500 625 x x x x x x x x x x x x 10V 1600 G80S A2A MTU 10V1600 DS500
550 688 x x x x x x x x x x x x 12V 1600 G70S A2A MTU 12V1600 DS550
600 750 x x x x x x x x x x x x 12V 1600 G80S A2A MTU 12V1600 DS600

12 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 13


Standard Backup – Diesel Generator Sets

Standard Backup - 3D
Standby Power (3D) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type

60Hz - Diesel
output (1) compliant variant (3)

240 V Re-connectable (1Ph.)


240 V Dedicated (1Phase)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

650 813 x x x x x x x x x x x x x 12V 2000 G45 W2A MTU 12V2000 DS650


MTU 2000 DS

750 938 x x x x x x x x x x x x x 12V 2000 G85 W2A MTU 12V2000 DS750


800 1000 x x x x x x x x x x x x x 12V 2000 G85 W2A MTU 12V2000 DS800
900 1125 x x x x x x x x x x x x x 16V 2000 G45 W2A MTU 16V2000 DS900
1000 1250 x x x x x x x x x x x x x 16V 2000 G85 W2A MTU 16V2000 DS1000
1080 1475 x x x x x x x x 18V 2000 G85 A2A MTU 18V2000 DS1200
1250 1563 x x x x x x x x x 18V 2000 G76S A2A MTU 18V2000 DS1250
1500 1875 x x x x x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1500
MTU 4000 DS

1750 2188 x x x x x x x x x x x 12V 4000 G83 W2A MTU 12V4000 DS1750


2000 2500 x x x x x x x x x x x x x x 16V 4000 G43 W2A MTU 16V4000 DS2000
2250 2813 x x x x x x x x x x x x x 16V 4000 G83 W2A MTU 16V4000 DS2250
2500 3125 x x x x x x x x x x x x x 16V 4000 G83L W2A MTU 16V4000 DS2500
2500 3125 x x x x x x x x x x x x x 20V 4000 G43 W2A MTU 16V4000 DS2500
2800 3500 x x x x x x x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS2800
3000 3750 x x x x x x x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS3000
3250 4063 x x x x x x x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS3250

Standard Backup – Diesel Generator Sets


Standby Power (3D) – 60 Hz / 1500 rpm - Europe, Africa, Asia and Australia

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type
output (1) compliant variant (3)
240 V Re-connectable (1Ph.)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
400 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

CE compliant

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012

kWe kVA

1550 1938 x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1550


MTU 4000 DS

2070 2588 x x x x x x x 16V 4000 G43 W2A MTU 16V4000 DS2050


3250 4063 x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS3250

14 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 15


Standard Backup – Gas Generator Sets

Standard Backup - 3D
Standby Power (3D) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Fuel type Housing Engine type Genset type
output (1)

60Hz - Gas
240 V Re-connectable (1Ph.)
240 V Dedicated (1Phase)

13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)
4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

EPA certified

Natural Gas

Propan Gas

Enclosure

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

30 37 x x x x x x x x x x x x x 30-GC6NLT1 MTU 4R0075 GS30


MTU 0063 - 0183 GS / Natural Gas

40 50 x x x x x x x x x x x x x 40-GC6NLT1 MTU 6V0072 GS40


50 62 x x x x x x x x x x x x x 50-GC6NLT1 MTU 8V0063 GS50
60 75 x x x x x x x x x x x x x 60-GC6NLT1 MTU 8V0071 GS60
70 87 x x x x x x x x x x x x x GS75N6S-A MTU 10V0068 GS75
100 125 x x x x x x x x x x x x x GS100N6S-A MTU 10V0068 GS100
125 156 x x x x x x x x x x x x x GS125N6S-A MTU 10V0068 GS125
150 187 x x x x x x x x x x x x GS150N6S-A MTU 6R0135 GS150
200 250 x x x x x x x x x x x x GS200N6S-A MTU 6R0185 GS150
260 325 x x x x x x x x x x x GS260N6S-A MTU 8V0183 GS260
350 437 x x x x x x x x x x x GS350N6S-A MTU 10V0183 GS350
400 500 x x x x x x x x x x x GS400N6S-A MTU 12V0183 GS400
30 37 x x x x x x x x x x x x x 30-GC6NLT1 MTU 4R0075 GS30
MTU 0063 - 0183 GS / Propan Gas

40 50 x x x x x x x x x x x x x 40-GC6NLT1 MTU 6V0072 GS40


50 62 x x x x x x x x x x x x x 50-GC6NLT1 MTU 8V0063 GS50
60 75 x x x x x x x x x x x x x 60-GC6NLT1 MTU 8V0071 GS60
75 93 x x x x x x x x x x x x x GS75L6S-A MTU 10V0068 GS75
100 125 x x x x x x x x x x x x x GS100L6S-A MTU 10V0068 GS100
125 156 x x x x x x x x x x x x x GS125L6S-A MTU 10V0068 GS125
100 125 x x x x x x x x x x x x GS150L6S-A MTU 6R0135 GS150
130 162 x x x x x x x x x x x x GS200L6S-A MTU 6R0185 GS200
160 200 x x x x x x x x x x x GS260L6S-A MTU 8V0183 GS260
245 306 x x x x x x x x x x x GS350L6S-A MTU 10V0183 GS350
295 368 x x x x x x x x x x x GS400L6S-A MTU 12V0183 GS400

16 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 17


Standard Backup – Diesel Generator Sets
Standby Power with overload (3E) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
6300 kV (3 Phase)
6600 kV (3 Phase)
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528

Standard Backup - 3E
CE/IEC
ORDE

Standby Power with


kWe kVA

Overload – 50 Hz

50Hz - Diesel
600 750 x x x x x x x x x x x x x x x x 12V 2000 G16F A2A MTU 12V2000 DS825
MTU 2000 DS

640 800 x x x x x x x x x x x x x x x x 12V 2000 G26F A2A MTU 12V2000 DS1000


730 910 x x x x x x x x x x x x x x x x 16V 2000 G16F A2A MTU 16V2000 DS1000
800 1000 x x x x x x x x x x x x x x x x 16V 2000 G26F A2A MTU 16V2000 DS1100
900 1135 x x x x x x x x x x x x x x x x 16V 2000 G36F A2A MTU 16V2000 DS1250
1000 1250 x x x x x x x x x x x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400
1240 1550 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650
MTU 4000 DS

1320 1650 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1480 1850 x x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000
1680 2100 x x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1800 2250 x x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2080 2600 x x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650
2280 2850 x x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2480 3100 x x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200

18 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 19


Mission Critical – Diesel Generator Sets
Data Center Continuous Power (3F) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


6300 V (3 Phase)
6600 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
CE/IEC
ORDE
kWe kVA
MTU 2000 DS

800 1000 x x x x x x x x x x x x x x x x x 16V 2000 G26F A2A MTU 16V2000 DS1100


1000 1250 x x x x x x x x x x x x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400
1240 1550 x x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650
MTU 4000 DS

1320 1650 x x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1480 1850 x x x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000

Mission Critical - 3F
1680 2100 x x x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1800 2250 x x x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2080 2600 x x x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650

50Hz - Diesel
2280 2850 x x x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2480 3100 x x x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200

20 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 21


Mission Critical – Diesel Generator Sets
Data Center Continuous Power (3F) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type
output (1) compliant variant (3)

240 V Re-connectable (1Ph.)


240 V Dedicated (1Phase)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

1135 1419 x x x x x x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1250


MTU 4000 DS

1400 1750 x x x x x x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1500


1600 2000 x x x x x x x x x x x x 12V 4000 G83 W2A MTU 12V4000 DS1750
1825 2281 x x x x x x x x x x x x x x x 16V 4000 G43 W2A MTU 16V4000 DS2000
2045 2555 x x x x x x x x x x x x x x x 16V 4000 G83 W2A MTU 16V4000 DS2250

Mission Critical - 3F
2275 2844 x x x x x x x x x x x x x x x 20V 4000 G43 W2A MTU 20V4000 DS2500
2500 3125 x x x x x x x x x x x x x x x 20V 4000 G83 W2A MTU 20V4000 DS2800
2800 3500 x x x x x x x x x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS3000

60Hz - Diesel
22 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 23
Mission Critical – Diesel Generator Sets
Mission Critical Power (3H) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


6300 V (3 Phase)
6600 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
CE/IEC
ORDE
kWe kVA
MTU 2000 DS

800 1000 x x x x x x x x x x x x x x x x x 16V 2000 G26F A2A MTU 16V2000 DS1100


1000 1250 x x x x x x x x x x x x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400
1240 1550 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650
MTU 4000 DS

1320 1650 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1480 1850 x x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000
1680 2100 x x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1800 2250 x x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2080 2600 x x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650
2280 2850 x x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2480 3100 x x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200

Mission Critical - 3H
50Hz - Diesel
24 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 25
MTU 2000 DS

600

800
640
kWe

26 / //  /
Power
output (1)

750
800
kVA

1000
x
x
x
380 V (3 Phase)

MTU Onsite Energy


x
x
x
400 V (3 Phase)

x
x
x
415 V (3 Phase)

x
6300 V (3 Phase)
Available voltages

x
6600 V (3 Phase)

x
10000 V (3 Phase)

x
10500 V (3 Phase)
x
Continuous Power (3A) – 50 Hz / 1500 rpm

11000 V (3 Phase)
Continuous/Peak – Diesel Generator Sets

Fuel consumption
x
x
x

optimized
Emissions

Exhaust emission
optimized acc. TA-Luft

NEA Singapore for


ORDE

compliant
EPA Tier 2

Exhaust emission EU
97/68 EC Stage II

Exhaust emission EU
97/68 EC Stage IIIA
Exhaust emission EU
97/68 EC Stage IIIA
under FLEX program
x
x
x

ISO 8528
x
x
x

CE / IEC
x
x
x

NFPA 110
Certifications

x
x
x

German Grid Code


x
x
x

ISO 8528-5 - G2
class (2)

x
x
x

ISO 8528-5 - G3
Perform.

x
x
x

Tier I & Tier II


compl.

x
x
x

Tier III & Tier IV


Uptime

x
x

Enclosure
x
x
x

Container
Housing
Engine type

16V 2000 B26F


12V 2000 B26F

18V 2000 B26F


A2A
A2A
A2A
Cooling
variant (3)
Genset type

MTU Onsite Energy


/ //  /
MTU 16V2000 DS1250
MTU 12V2000 DS1000

MTU 18V2000 DS1400

27

Continuous/Peak - 3A
50Hz - Diesel
Continuous/Peak – Gas Generator Sets
Continuous Power (3A) – 50 Hz (400V / NOx < 500 mg/Nm3)

Fuel type Output Energy Efficiency Methane Engine type Genset type
input (10) number (11)

Low Temp. kWth (°C)


Exhaust (9) kWth (°C)
Therm. (8) kWth

Electr. ntot (%)


Electr. (7) kWel

Electr. nel (%)


Natural Gas

Biogas

kW
x
182 138 110 (180) ––– 491 37,0 87,5 ≥ 120 B3066 L3 MTU 6R400 GS
MTU 400 GS

x
192 118 97 (180) 29 (50) 499 38,5 81,6 ≥ 120 B3066 L4 MTU 6R400 GS
x
220 126 110 (180) 17 (40) 559 39,4 81,6 ≥ 120 B3066 Z8 MTU 6R400 GS
x
350 267 208 (180) ––– 945 37,1 87,3 ≥ 120 B3042 L3 MTU 12V400 GS
x
370 190 211 (180) 48 (50) 955 38,8 80,8 ≥ 120 B3042 L8 MTU 12V400 GS
x
400 245 222 (180) 29 (40) 1015 39,4 85,4 ≥ 120 B3042 Z7 MTU 12V400 GS
x 135 115 89 (90) ––– 371 36,4 91,4 ≥ 70 E3066 D4* MTU 6R400 GS*
x 182 122 143 (120) ––– 506 36,0 88,3 ≥ 70 E3066 L9 MTU 6R400 GS
x 191 103 149 (120) 29 (50) 534 35,8 83,0 ≥ 70 E3066 L9 MTU 6R400 GS
x 201 106 154 (120) 36 (40) 560 35,9 82,3 ≥ 70 E3066 L9 MTU 6R400 GS
x 220 117 134 (120) 17 (40) 558 39,4 84,4 ≥ 80 E3066 Z5 MTU 6R400 GS
x 245 224 154 (100) ––– 675 36,3 92,3 ≥ 70 E3042 D4* MTU 12V400 GS*
x 357 235 256 (120) ––– 952 37,5 89,1 ≥ 70 E3042 L9 MTU 12V400 GS
x 370 194 263 (120) 52 (50) 988 37,4 83,7 ≥ 70 E3042 L9 MTU 12V400 GS
x 390 233 241 (120) 28 (40) 995 39,2 86,8 ≥ 70 E3042 Z6 MTU 12V400 GS
x 420 247 257 (120) 31 (40) 1064 39,5 86,8 ≥ 80 E3042 Z6 MTU 12V400 GS
Cogeneration Module 100°/80°C heating water cicuit
x 116 110 80 (120) ––– 337 34,4 90,8 ≥ 70 E3066 DH3* MTU 6R400 GS*
x 165 111 130 (120) ––– 465 35,5 87,3 ≥ 70 E3066 LH9 MTU 6R400 GS
x 227 210 141 (120) ––– 628 36,1 92,0 ≥ 80 E3042 DH3* MTU 12V400 GS*
x 323 206 250 (120) ––– 879 36,7 88,6 ≥ 70 E3042 LH9 MTU 12V400 GS
*  = 1 with 3-Way-Catalyst, NOx < 250 mg/Nm3

Continuous/Peak - 3A
Genset with optional heat recovery module

50Hz - Gas
28 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 29
Continuous/Peak – Gas Generator Sets
Continuous Power + CHP (3A) – 50 Hz (400V / NOx < 500 mg/Nm3)

Fuel type Output Energy Efficiency Methane Engine type Genset type
input (10) number (11)

Low Temp. kWth (°C)


Exhaust (9) kWth (°C)
Therm. (8) kWth

Electr. ntot (%)


Electr. (7) kWel

Electr. nel (%)


Natural Gas

Biogas

kW
x 800 392 402 (120) 78 (40) 1861 43,0 85,7 ≥ 120 L32 MTU 8V4000 GS
MTU 4000 GS

x 1169 572 603 (120) 103 (40) 2719 43,0 86,2 ≥ 120 L32 MTU 12V4000 GS
x 1560 628 800 (120) 318 (40) 3616 43,1 82,6 ≥ 120 L32 MTU 16V4000 GS
x 1950 736 1048 (120) 394 (40) 4502 43,3 82,9 ≥ 120 L32 MTU 20V4000 GS
x 776 401 422 (120) 47 (40) 1832 42,4 87,3 ≥ 70 L33 MTU 8V4000 GS
x 854 443 448 (120) 49 (40) 1993 42,8 87,5 ≥ 80 L33 MTU 8V4000 GS
x 1012 475 461 (120) 69 (43) 2298 44,0 84,8 ≥ 80 L64 MTU 8V4000 GS
x 1286 664 659 (120) 88(40) 2974 43,2 87,7 ≥ 80 L33 MTU 12V4000 GS
x 1523 712 691 (120) 104 (43) 3438 44,3 85,1 ≥ 80 L64 MTU 12V4000 GS
x 1718 974 821 (120) 113 (40) 3991 43,0 88,0 ≥ 80 L33 MTU 16V4000 GS
x 1999 950 928 (120) 125 (43) 4511 44,3 85,9 ≥ 80 L64 MTU 16V4000 GS
x 2028 965 936 (120) 127 (43) 4573 44,3 85,9 ≥ 80 L64 MTU 16V4000 GS
x 2145 1161 1078 (120) 142 (40) 4990 43,0 87,9 ≥ 80 L33 MTU 20V4000 GS
x 2535 1186 1212 (120) 176 (43) 5751 44,1 85,8 ≥ 80 L64 MTU 20V4000 GS
Hot ambient conditions
x 776 446 420 (120) 32 (53) 1853 41,9 88,6 ≥ 80 L32 MTU 8V4000 GS
x 1169 632 638 (120) 43 (53) 2747 42,5 88,8 ≥ 80 L32 MTU 12V4000 GS
x 1560 863 805 (120) 76 (53) 3651 42,7 88,4 ≥ 80 L32 MTU 16V4000 GS
x 1948 1035 1101 (120) 78 (53) 4577 42,6 89,2 ≥ 80 L32 MTU 20V4000 GS
Low methane number
x 1560 921 937 (120) 84 (40) 3848 40,5 88,8 ≥ 60 L32 ER MTU 16V4000 GS
x 1948 1143 1181 (120) 99 (53) 4812 40,5 88,8 ≥ 60 L32 ER MTU 20V4000 GS
Genset with optional heat recovery module

CHP - 3A 50Hz - Gas


Continuous/Peak +
30 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 31
Continuous/Peak – Gas Generator Sets
Continuous Power + CHP (3A) – 60 Hz (480V / NOx < 500 mg/Nm3)

Fuel type Output Energy Efficiency Methane Engine type Genset type
input (10) number (11)

Low Temp. kWth (°C)


Exhaust (9) kWth (°C)
Therm. (8) kWth

Electr. ntot (%)


Electr. (7) kWel

Electr. nel (%)


Natural Gas

Biogas

kW
x 175 139 94 (180) ––– 491 35,6 83,0 ≥ 120 B3066 L8 MTU 6R400 GS
MTU 400 GS

x 200 150 146 (180) 13 (50) 559 35,7 88,7 ≥ 120 B3066 Z8 MTU 6R400 GS
x 350 239 226 (180) ––– 951 36,8 85,7 ≥ 120 B3042 Z7 MTU 12V400 GS
x 128 120 94 (110) ––– 376 34,0 90,9 ≥ 70 E3066 D3* MTU 6R400 GS*
x 248 254 169 (120) ––– 731 33,9 91,8 ≥ 70 E3042 D3* MTU 12V400 GS*
x 358 257 268 (120) ––– 981 36,5 90,0 ≥ 70 E3042 Z6 MTU 12V400 GS
x 762 428 353 (180) 68 (53) 1875 40,6 82,3 ≥ 120 L32 MTU 8V4000 GS
MTU 4000 GS

x 1152 620 519 (180) 90 (53) 2758 41,8 83,1 ≥ 120 L32 MTU 12V4000 GS
x 1549 648 671 (180) 330 (53) 3652 42,4 78,4 ≥ 120 L32 MTU 16V4000 GS
x 1932 766 857 (180) 434 (53) 4581 42,2 77,6 ≥ 120 L32 MTU 20V4000 GS
x 762 410 426 (120) 47 (40) 1851 41,2 86,3 ≥ 70 L33 MTU 8V4000 GS
x 840 452 453 (120) 49 (40) 2014 41,7 86,6 ≥ 80 L33 MTU 8V4000 GS
x 1272 664 659 (120) 88 (40) 2974 42,8 87,3 ≥ 80 L33 MTU 12V4000 GS
x 1705 974 821 (120) 113 (40) 3991 42,7 87,7 ≥ 80 L33 MTU 16V4000 GS
x 2129 1158 1077 (120) 142 (40) 4985 42,7 87,5 ≥ 80 L33 MTU 20V4000 GS
Hot ambient conditions
x 762 455 424 (120) 32 (53) 1872 40,7 87,7 ≥ 80 L32 MTU 8V4000 GS
x 1147 632 638 (120) 43 (53) 2747 41,8 88,0 ≥ 80 L32 MTU 12V4000 GS
x 1550 863 805 (120) 76 (53) 3651 42,5 88,1 ≥ 80 L32 MTU 16V4000 GS
x 1932 1035 1101 (120) 78 (53) 4577 42,2 88,9 ≥ 80 L32 MTU 20V4000 GS
*  = 1 with 3-Way-Catalyst, NOx < 250 mg/Nm3
Genset with optional heat recovery module

CHP - 3A 60Hz - Gas


Continuous/Peak +
32 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 33
Continuous/Peak – Diesel Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type

50Hz - Diesel
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


6300 V (3 Phase)
6600 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
CE / IEC
ORDE
kWe kVA

24 30 (4) x x x x x x x x F32 AM 1A A2A MTU 4R0080 DS33


MTU 0080/0113 DS

33 41 (4) x x x x x x x x F32 SM 1A A2A MTU 4R0080 DS45


40 50 (4) x x x x x x x x F32 TM 1A A2A MTU 4R0080 DS55
48 60 (4) x x x x x x x x NEF45 SM 1A A2A MTU 4R0113 DS63
58 73 (4) x x x x x x x x NEF45 SM 2A A2A MTU 4R0113 DS80
68 85 (4) x x x x x x x x NEF45 SM 5 A2A MTU 4R0113 DS94
224 280 (4) x x x x x x x x x x x x x 6R 1600 G10F A2A MTU 6R1600 DS300
MTU 1600 DS

240 300 (4) x x x x x x x x x x x x x 6R 1600 G20F A2A MTU 6R1600 DS330


280 350 (4) x x x x x x x x x x x x x 8V 1600 G10F A2A MTU 8V1600 DS400
320 400 (4) x x x x x x x x x x x x x 8V 1600 G20F A2A MTU 8V1600 DS440
368 460 (4) x x x x x x x x x x x x x 10V 1600 G10F A2A MTU 10V1600 DS500
408 510 (4) x x x x x x x x x x x x x 10V 1600 G20F A2A MTU 10V1600 DS560
480 600 (4) x x x x x x x x x x x x 12V 1600 G10F A2A MTU 12V1600 DS660
528 660 (4) x x x x x x x x x x x x 12V 1600 G20F A2A MTU 12V1600 DS730
616 770 x x x x x x x x x x x 12V 2000 G65 A2A MTU 12V2000 DS850
MTU 2000 DS-G05

656 820 x x x x x x x x x x 12V 2000 G65TB W2A MTU 12V2000 DS890


720 900 x x x x x x x x x x x 16V 2000 G25 A2A MTU 16V2000 DS1000
728 910 x x x x x x x x x x 16V 2000 G25TB W2A MTU 16V2000 DS1050
800 1000 x x x x x x x x x x x 16V 2000 G65 A2A MTU 16V2000 DS1100
824 1030 x x x x x x x x x x 16V 2000 G65TB W2A MTU 16V2000 DS1140
904 1130 (5) x x x x x x x x x x x 18V 2000 G65 A2A MTU 18V2000 DS1250
928 1160 x x x x x x x x x x 18V 2000 G65TB W2A MTU 18V2000 DS1290
600 750 x x x x x x x x x x x x x x x x 12V 2000 G16F A2A MTU 12V2000 DS825
MTU 2000 DS-G06

640 800 x x x x x x x x x x x x x x x x 12V 2000 G26F A2A MTU 12V2000 DS1000


730 910 x x x x x x x x x x x x x x x x 16V 2000 G16F A2A MTU 16V2000 DS1000
800 1000 x x x x x x x x x x x x x x x x 16V 2000 G26F A2A MTU 16V2000 DS1100
900 1135 x x x x x x x x x x x x x x x x 16V 2000 G36F A2A MTU 16V2000 DS1250
1000 1250 x x x x x x x x x x x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400

34 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 35


Continuous/Peak – Diesel Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type

50Hz - Diesel
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


6300 V (3 Phase)
6600 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
CE / IEC
ORDE
kWe kVA

1240 1550 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650


MTU 4000 DS

1320 1650 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1480 1850 x x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000
1680 2100 x x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1800 2250 x x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2080 2600 x x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650
2280 2850 x x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2480 3100 x x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200

36 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 37


Continuous/Peak – Diesel Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 50 Hz / 1500 rpm – North and Latin America

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type

50Hz - Diesel
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


3300 V (3 Phase)
220 V (1 Phase)
220 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


CE compliant
EPA Tier 2
compliant

Enclosure
optimized

Container
NFPA 110
ISO 8528
ORDE
kWe kVA
MTU 0096 DS

27 34 x x x x x x x x x x 3029 TFG89 TC only MTU 3R0096 DS34


35 44 x x x x x x x x x x 4045 TF280 TC only MTU 3R0096 DS44
44 55 x x x x x x x x x x 4045 HF280 TC only MTU 3R0096 DS55
64 80 x x x x x x x x x x x x 4R 924 G10F A2A MTU 4R0120 DS90
MTU 0120 DS

80 100 x x x x x x x x x x x x 4R 924 G20F A2A MTU 4R0120 DS110


100 125 x x x x x x x x x x x x 4R 924 G30F A2A MTU 4R0120 DS140
120 150 x x x x x x x x x x x x 6R 926 G10F A2A MTU 6R0120 DS165
144 180 x x x x x x x x x x x x 6R 926 G20F A2A MTU 6R0120 DS200
160 200 x x x x x x x x x x x x 6R 926 G30F A2A MTU 6R0120 DS220
220 275 x x x x x x x x x 6R 1600 G10F A2A MTU 6R1600 DS300
MTU 1600 DS

240 300 x x x x x x x x x 6R 1600 G20F A2A MTU 6R1600 DS330


292 365 x x x x x x x x x 8V 1600 G10F A2A MTU 8V1600 DS400
320 400 x x x x x x x x x 8V 1600 G20F A2A MTU 8V1600 DS440
360 450 x x x x x x x x x 10V 1600 G10F A2A MTU 10V1600 DS500
400 500 x x x x x x x x x 10V 1600 G20F A2A MTU 10V1600 DS550
472 590 x x x x x x x x x 12V 1600 G10F A2A MTU 12V1600 DS650
520 650 x x x x x x x x x 12V 1600 G20F A2A MTU 12V1600 DS715
1000 1250 x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400
MTU 2000 DS

38 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 39


Continuous/Peak – Diesel Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type

60Hz - Diesel
output (1) compliant variant (3)

240 V Re-connectable (1Ph.)


240 V Dedicated (1Phase)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

27 34 x x x x x x x x x x x x x x 3029TFG89 TC only MTU 3R0096 DS30


MTU 0096/0113 DS

35 44 x x x x x x x x x x x x x x 4045TF280 TC only MTU 4R0113 DS35


40 50 x x x x x x x x x x x x x x 4045TF280 TC only MTU 4R0113 DS40
45 56 x x x x x x x x x x x x x x 4045TF280 TC only MTU 4R0113 DS50
55 69 x x x x x x x x x x x x x x 4045HF280 A2A MTU 4R0113 DS60
80 100 x x x x x x x x x x x x x x 4045HF285 A2A MTU 4R0113 DS80
90 113 x x x x x x x x x x x x x x 4045HF285 A2A MTU 4R0113 DS100
111 139 x x x x x x x x x x x x x x 4045HF285 A2A MTU 4R0113 DS125
135 169 x x x x x x x x x x x x x x 6068HF285 A2A MTU 6R0113 DS150
180 225 x x x x x x x x x x x x x x 6068HF485 A2A MTU 6R0113 DS180
72 90 x x x x x x x x x x x x x 4R 924 G10S A2A MTU 4R0120 DS80
MTU 0120 DS

90 113 x x x x x x x x x x x x x 4R 924 G20S A2A MTU 4R0120 DS100


111 139 x x x x x x x x x x x x x 4R 924 G30S A2A MTU 4R0120 DS125
135 169 x x x x x x x x x x x x x 6R 926 G10S A2A MTU 6R0120 DS150
163 204 x x x x x x x x x x x x x 6R 926 G20S A2A MTU 6R0120 DS180
180 225 x x x x x x x x x x x x x 6R 926 G30S A2A MTU 6R0120 DS200

40 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 41


Continuous/Peak – Diesel Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Uptime Housing Engine type Cooling Genset type

60Hz - Diesel
output (1) compliant variant (3)

240 V Re-connectable (1Ph.)


240 V Dedicated (1Phase)

Fuel consumption
13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)

Tier III & Tier IV


4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

Tier I & Tier II


EPA Tier 4i

EPA Tier 3

EPA Tier 2

Enclosure
optimized

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

210 263 x x x x x x x x x x x x x x x 6R 1600 G10S A2A MTU 6R1600 DS230


MTU 1600 DS

230 288 x x x x x x x x x x x x x x x 6R 1600 G10S A2A MTU 6R1600 DS250


250 313 x x x x x x x x x x x x x x x 6R 1600 G10S A2A MTU 6R1600 DS275
275 344 x x x x x x x x x x x x x x x 6R 1600 G20S A2A MTU 6R1600 DS300
325 406 x x x x x x x x x x x x x x x 8V 1600 G10S A2A MTU 8V1600 DS350
365 456 x x x x x x x x x x x x x x x 8V 1600 G20S A2A MTU 8V1600 DS400
400 500 x x x x x x x x x x x x x x x 10V 1600 G70S A2A MTU 10V1600 DS450
450 563 x x x x x x x x x x x x x x x 10V 1600 G20S A2A MTU 10V1600 DS500
500 625 x x x x x x x x x x x x x x x 12V 1600 G10S A2A MTU 12V1600 DS550
550 688 x x x x x x x x x x x x x x x 12V 1600 G20S A2A MTU 12V1600 DS600
615 769 x x x x x x x x x x x x x x x 12V 2000 G45 W2A MTU 12V2000 DS650
MTU 2000 DS

680 850 x x x x x x x x x x x x x x x 12V 2000 G85 W2A MTU 12V2000 DS750


725 906 x x x x x x x x x x x x x x x 12V 2000 G85 W2A MTU 12V2000 DS800
800 1000 x x x x x x x x x x x x x x x 16V 2000 G45 W2A MTU 16V2000 DS900
900 1125 x x x x x x x x x x x x x x x 16V 2000 G85 A2A MTU 16V2000 DS1000
1000 1250 x x x x x x x x x x x x x x 18V 2000 B76 A2A MTU 18V2000 DS1250
1125 1406 x x x x x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1250
MTU 4000 DS

1400 1750 x x x x x x x x x x x 12V 4000 G43 W2A MTU 12V4000 DS1500


1600 2000 x x x x x x x x x x x 12V 4000 G83 W2A MTU 12V4000 DS1750
1800 2250 x x x x x x x x x x x x x x 16V 4000 G43 W2A MTU 16V4000 DS2000
2045 2556 x x x x x x x x x x x x x 16V 4000 G83 W2A MTU 16V4000 DS2250
2250 2813 x x x x x x x x x x x x x 20V 4000 G43 W2A MTU 20V4000 DS2500
2500 3125 x x x x x x x x x x x x x 20V 4000 G83 W2A MTU 20V4000 DS2800
2800 3500 x x x x x x x x x x x x x 20V 4000 G83L W2A MTU 20V4000 DS3000

42 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 43


Continuous/Peak – Gas Generator Sets

Continuous/Peak - 3B
Prime Power (3B) – 60 Hz / 1800 rpm

Power Available voltages Emissions Certifications Fuel type Housing Engine type Genset type
output (1)

60Hz - Gas
240 V Re-connectable (1Ph.)
240 V Dedicated (1Phase)

13800 V (3 Phase)
13200 V (3 Phase)
12470 V (3 Phase)
4160 V (3 Phase)
208 V (3 Phase)

380 V (3 Phase)
480 V (3 Phase)
600 V (3 Phase)
240 V (3 Phase)

EPA certified

Natural Gas

Propan Gas

Enclosure

Container
NFPA 110
ISO 8528

IBC 2012
UL2200
kWe kVA

162 130 x x x x x x x x x x x x x GS150N6S-A MTU 6R0135 GS150


MTU 0135 - 0185 GS

218 175 x x x x x x x x x x x x x GS200N6S-A MTU 6R0185 GS200


294 235 x x x x x x x x x x x x x GS260N6S-A MTU 8V0183 GS260
375 300 x x x x x x x x x x x x x GS350N6S-A MTU 10V0183 GS350
443 355 x x x x x x x x x x x x x GS400N6S-A MTU 12V0183 GS400

44 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 45


Continuous/Peak – Diesel Generator Sets
Grid Stability Power (3G) – 50 Hz / 1500 rpm

Power Available voltages Emissions Certifications Perform. Uptime Housing Engine type Cooling Genset type
output (1) class (2) compl. variant (3)

optimized acc. TA-Luft

Exhaust emission EU

Exhaust emission EU

Exhaust emission EU
97/68 EC Stage IIIA
97/68 EC Stage IIIA
NEA Singapore for
Fuel consumption

Exhaust emission

German Grid Code


97/68 EC Stage II
10000 V (3 Phase)
10500 V (3 Phase)
11000 V (3 Phase)

under FLEX program

ISO 8528-5 - G2

ISO 8528-5 - G3

Tier III & Tier IV


6300 V (3 Phase)
6600 V (3 Phase)
380 V (3 Phase)
400 V (3 Phase)
415 V (3 Phase)

Tier I & Tier II


EPA Tier 2
compliant

Enclosure

Continuous/Peak - 3G
optimized

Container
NFPA 110
ISO 8528
CE / IEC
ORDE
kWe kVA
MTU 2000 DS

50Hz - Diesel
800 1000 x x x x x x x x x x x x x x x x x 16V 2000 G26F A2A MTU 16V2000 DS1100
1000 1250 x x x x x x x x x x x x x x x x x x x x x 18V 2000 G26F A2A MTU 18V2000 DS1400
1240 1550 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1650
MTU 4000 DS

1320 1650 x x x x x x x x x x x x x x x x 12V 4000 G23 W2A MTU 12V4000 DS1750


1480 1850 x x x x x x x x x x x x x x x x 12V 4000 G63 W2A MTU 12V4000 DS2000
1680 2100 x x x x x x x x x x x x x x x x 16V 4000 G23 W2A MTU 16V4000 DS2250
1800 2250 x x x x x x x x x x x x x x x x 16V 4000 G63 W2A MTU 16V4000 DS2500
2080 2600 x x x x x x x x x x x x x x x x 20V 4000 G23 W2A MTU 20V4000 DS2650
2280 2850 x x x x x x x x x x x x x x x x 20V 4000 G63 W2A MTU 20V4000 DS3100
2480 3100 x x x x x x x x x x x x x x x x 20V 4000 G63L W2A MTU 20V4000 DS3200

46 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 47


Diesel Generator Sets
Container – 50 Hz / 1500 rpm

Dimensions Noise level * Noise level * Noise level * with silencer Fuel tank Emissions Genset type
without silencer box with silencer box box and add. exhaust silencer (option)

CSS certification
Length (mm)

Height (mm)
Width (mm)

Capacity (l)
dBA @ 1m

dBA @ 7m

dBA @ 1m

dBA @ 7m

dBA @ 1m

dBA @ 7m
Size

20ft HC 6058 2438 2896 C/F C/F C/F C/F C/F C/F 500 x MTU 12V2000 DS825
MTU 2000 DS

20ft HC 6058 2438 2896 C/F C/F C/F C/F C/F C/F 500 x MTU 12V2000 DS1000
20ft HC 6058 2438 2896 C/F C/F C/F C/F C/F C/F 500 x MTU 16V2000 DS1100
20ft HC 6058 2438 2896 C/F C/F C/F C/F C/F C/F 500 x MTU 16V2000 DS1250
20ft HC 6058 2438 2896 97 88 86 77 80 71 500 x MTU 18V2000 DS1400
* All levels in accordance with European Noise Directive (2000/14/EC)

Contiainer
50 Hz
48 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 49
Diesel Generator Sets
Enclosures – 50 Hz / 1500 rpm

Dimensions Noise level * Fuel tank Genset type


Standard (option)
Length (mm)

Height (mm)
Width (mm)

Capacity (l)
dBA @ 7m
2100 957 1349 61,7 100 MTU 4R0080 DS33
MTU 0080/0113 DS

2100 957 1349 60 100 MTU 4R0080 DS45


2300 1050 1458 59,3 130 MTU 4R0080 DS55
2750 1100 1760 61,2 288 MTU 4R0113 DS63
2750 1100 1760 61,3 288 MTU 4R0113 DS80
2750 1100 1760 61,5 288 MTU 4R0113 DS94
2750 1100 1760 C/F 288 MTU 4R0120 DS90
MTU 0120 DS

2750 1100 1760 C/F 288 MTU 4R0120 DS110


2750 1100 1760 C/F 288 MTU 4R0120 DS140
C/F C/F C/F C/F C/F MTU 6R0120 DS175
C/F C/F C/F C/F C/F MTU 6R0120 DS200
C/F C/F C/F C/F C/F MTU 6R0120 DS235
C/F C/F C/F C/F C/F MTU 6R0120 DS250
4100 1600 2200 63 597 MTU 6R1600 DS300
MTU 1600 DS

4100 1600 2200 63,2 597 MTU 6R1600 DS330


4500 1800 2340 62,8 740 MTU 8V1600 DS400
4500 1800 2340 62,8 740 MTU 8V1600 DS440

Enclosures
4500 1800 2340 62,8 740 MTU 10V1600 DS500
4500 1800 2340 62,8 740 MTU 10V1600 DS560

50 Hz
5000 2100 2369 72,2 950 MTU 12V1600 DS660
5000 2100 2369 74,5 950 MTU 12V1600 DS730
C/F C/F C/F C/F 900 MTU 12V2000 DS825
MTU 2000 DS

C/F C/F C/F C/F 900 MTU 12V2000 DS1000


7100 2190 2480 C/F 900 MTU 16V2000 DS1100
7100 2190 2480 C/F 900 MTU 16V2000 DS1250
* All levels in accordance with European Noise Directive (2000/14/EC)

50 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 51


Diesel Generator Sets
Enclosures – 60 Hz / 1800 rpm

Prime Power Standby Power Certifications Genset type


Level 1 (dBA @ 7m)

Level 2 (dBA @ 7m)

Level 3 (dBA @ 7m)

Level 1 (dBA @ 7m)

Level 2 (dBA @ 7m)

Level 3 (dBA @ 7m)

IBC 2012/OSHPD
ISO 9001:2008
UL 2200

CSA
68,2 68,4 60,8 68,8 68,1 59,2 x x x MTU 4R0060 DS30
MTU 0060/0113 DS

C/F C/F C/F C/F 73,4 66,5 x x x MTU 4R0113 DS35


C/F C/F C/F C/F 73,6 65,1 x x x MTU 4R0113 DS40
77,6 72 64,3 78,2 71,9 64,7 x x x MTU 4R0113 DS50
76,7 70,8 67,4 76,8 71,1 67,8 x x x MTU 4R0113 DS60
78,9 75,2 70,9 78,9 75,2 70,9 x x x x MTU 4R0113 DS80
79 74,9 70,9 78,9 75,2 70,9 x x x x MTU 4R0113 DS100
82,5 81,8 71,9 82,8 81,7 72 x x x x MTU 4R0113 DS125
84,3 82,9 73,1 84,5 83 73,4 x x x x MTU 6R0113 DS150
85,1 83 73,9 85,1 83 73,9 x x x x MTU 6R0113 DS180
na na na 85,1 83 73,7 x x x x MTU 6R0113 DS200
C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 4R0120 DS80
MTU 0120 DS

C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 4R0120 DS100
C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 4R0120 DS125
C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 6R0120 DS150
C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 6R0120 DS180
C/F C/F C/F C/F C/F C/F C/F C/F C/F C/F MTU 6R0120 DS200

Enclosures
79,9 78,7 69,1 80,3 78,8 69,1 x x x x MTU 6R1600 DS230
MTU 1600 DS

80,3 78,8 69,7 80,5 78,5 69,2 x x x x MTU 6R1600 DS250

60 Hz
80,5 78,5 69,8 80,9 78,4 69,3 x x x x MTU 6R1600 DS275
80,9 78,4 69,9 81 78,6 69,2 x x x x MTU 6R1600 DS300
85,5 84,2 72,7 85,3 84,3 72,8 x x x x MTU 8V1600 DS350
85,5 84,1 72,8 85,9 84,6 72,9 x x x x MTU 8V1600 DS400
C/F 87,1 C/F 87,6 87,1 75,4 x x x x MTU 10V1600 DS450
87,6 87,1 75,4 87,8 87,1 75,4 x x x x MTU 10V1600 DS500
88,5 86,9 76,1 88,5 86,9 76,5 x x x x MTU 12V1600 DS550
88,3 86,9 76,5 88,5 86,8 76,7 x x x x MTU 12V1600 DS600

52 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 53


Diesel Generator Sets
Enclosures – 60 Hz / 1800 rpm

Prime Power Standby Power Certifications Genset type


Level 1 (dBA @ 7m)

Level 2 (dBA @ 7m)

Level 3 (dBA @ 7m)

Level 1 (dBA @ 7m)

Level 2 (dBA @ 7m)

Level 3 (dBA @ 7m)

IBC 2012/OSHPD
ISO 9001:2008
UL 2200

CSA
C/F C/F C/F 89 86,4 71,9 x x x MTU 12V2000 DS650
MTU 2000 DS

C/F C/F C/F 89 86,4 71,9 x x x MTU 12V2000 DS750


86 82,1 C/F 86,1 82 76 x x x MTU 12V2000 DS800
C/F C/F C/F 89,5 86,5 80,5 x x x MTU 12V2000 DS900
C/F C/F C/F 93 91,7 81,5 x x x MTU 12V2000 DS1000
C/F C/F C/F C/F 88 75,9 x x x MTU 12V4000 DS1250*
MTU 4000 DS

C/F C/F C/F C/F 89,2 76,2 x x x MTU 12V4000 DS1500*


C/F C/F C/F C/F 90,2 77,2 x x x MTU 12V4000 DS1750*
C/F C/F C/F C/F 91,8 84 x x x MTU 16V4000 DS2000*
*  = 1 with 3-Way-Catalyst, NOx < 250 mg/Nm3

Enclosures
60 Hz
54 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 55
Diesel Generator Sets
Power Modules - 50/60Hz – North and Latin America

Power Available Emissions Dimensions Frequency Application Certifications Engine type Cooling Genset type
output (1) voltages variant (3)

50/60Hz switchable
Fuel consumption

Continuous Power

CSC certification
Standby Power
Length (mm)

Prime Power
Height (mm)
Width (mm)
EPA Tier 2
optimized

NFPA 110
ISO 8528
280 V
400 V
480 V
600 V

Size
kWe kVA Hz

520 650 x x 20ft HC 6058 2438 2896 50 x x x x 12V 1600 G20 A2A MTU 12V1600 DS550
550 688 x x x x 20ft HC 6058 2438 2896 60 x x x x 12V 1600 G20 A2A MTU 12V1600 DS550
1000 1250 x x x 40ft HC 12192 2438 2896 60 x x x x 18V 2000 G85 W2A MTU 18V2000 DS1000
1500 1875 x x 40ft HC 12203 2438 2896 50 x x x x x 16V 4000 G63 W2A MTU 16V4000 DS1955
1760 2200 x x 40ft HC 12203 2438 2896 60 x x x x x 16V 4000 G83 W2A MTU 16V4000 DS1955
1720 2150 x x 40ft HC 12203 2438 2896 50 x x x x x 16V 4000 G63 W2A MTU 16V4000 DS1955
1995 2443 x x 40ft HC 12203 2438 2896 60 x x x x x 16V 4000 G83 W2A MTU 16V4000 DS1955
1900 2375 x x 40ft HC 12203 2438 2896 50 x x x x x 16V 4000 G63 W2A MTU 16V4000 DS1955
2160 2700 x x 40ft HC 12203 2438 2896 60 x x x x x 16V 4000 G83 W2A MTU 16V4000 DS1955

Diesel Generator Sets


Power Modules - 50/60Hz – Europe, Africa, Asia and Australia

Power Available Emissions Dimensions Frequency Application Certifications Engine type Cooling Genset type
output (1) voltages variant (3)

50/60Hz switchable
Fuel consumption

Continuous Power

CSC certification
Standby Power
Length (mm)

Prime Power
Height (mm)
Width (mm)
EPA Tier 2
optimized

NFPA 110
ISO 8528
280 V
400 V
480 V
600 V

Size

kWe kVA Hz

50/60 Hz - Diesel
Power Modules
1531 1914 x x 40ft HC 12203 2438 2896 50 x x x x 16V 4000 G63 W2A MTU 16V4000 DS2560
1807 2259 x x 40ft HC 12203 2438 2896 60 x x x x 16V 4000 G83 W2A MTU 16V4000 DS2560
1836 2295 x x 40ft HC 12203 2438 2896 50 x x x x 16V 4000 G63 W2A MTU 16V4000 DS2560
2109 2636 x x 40ft HC 12203 2438 2896 60 x x x x 16V 4000 G83 W2A MTU 16V4000 DS2560
2048 2560 x x 40ft HC 12203 2438 2896 50 x x x x 16V 4000 G63 W2A MTU 16V4000 DS2560
2321 2901 x x 40ft HC 12203 2438 2896 60 x x x x 16V 4000 G83 W2A MTU 16V4000 DS2560

56 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 57


Gas Generator Sets
Power Modules - 50/60Hz

Power Available Emissions Dimensions Frequency Application Engine type Fuel type Genset type
output (1) voltages

Continuous Power
Length (mm)

Height (mm)
Width (mm)
/2 TA Luft
TA Luft
400 V

480 V

50 Hz

60 Hz
Size
kWe

1
Power Application
1151 - 1272 x x 40ft HC 12203 2438 2896 x x L32/L33/L64 NG MTU 12V4000 GS
1538 - 2030 x x x 40ft HC 12203 2438 2896 x x L32/L33/L64 NG MTU 16V4000 GS
CHP Application
116 - 200 x x x 40ft HC 12203 2438 2896 x x x D/L/Z NG/NNG MTU 6R400 GS
30+ 9000 3000 3000
234 - 420 x x x 40ft HC 12203 2438 2896 x x x D/L/Z NG/NNG MTU 12V400 GS
30+ 9000 3000 3000
762 - 800 x x x 40+ 12203 3200 3200 x x L32/L33/L64 NG/NNG MTU 8V4000 GS
1151 - 1169 x x x 40+ 12203 3200 3200 x x L32/L33/L64 NG/NNG MTU 12V4000 GS
1534 - 1562 x x x 47+ 14200 3200 3200 x x L32/L33/L64 NG/NNG MTU 16V4000 GS
1924 - 2535 x x x 47+ 14200 3200 3200 x x L32/L33/L64 NG/NNG MTU 20V4000 GS

Power Modules
50/60 Hz - Gas
58 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 59
Classification for Data Footnotes
Center Continuous Power
according to
Uptime Institute
Tier I A Only available for 50Hz markets C/F: Consult factory

Tier I is composed of a single path for power and cooling distribution, without redundant components, B Unlimited hours in data center application where D: Lambda = 1 with 2-way-catalyst
providing 99,67 % availability. a reliable grid/utility is present.
L: Leanburn with single stage intercooling
Application descriptions, e.g. load factor, applies to MTU
Tier II powered equipment. Z: Leanburn with two stage intercooling

Tier II is composed of a single path for power and cooling distribution, with redundant components, (1) P
 ower output based on 400V, fuel consumption opt. Cooling variants:
providing 99,74 % availability. emission level and standard or optional generator. A2A: air-to-air charge air cooling (TD)
For arrangements with other emissions, voltages W2A: water-to-air charge air cooling (TB)
Tier III and/or optional generators, ratings may vary. Series
4000 without cooling package. Available power for diesel generator sets –
Tier III is composed of multiple active power and cooling distribution paths, but only one active path
(2) Ambient conditions and load application acc. to 50Hz/1500 rmp
has redundant components and is concurrently maintainable, providing 99,98 % availability.
ISO 8528 Standard:
// Site altitude above sea level: 400 m
Tier IV (3) Cooling variants: A2A: air-to-air charge air cooling // Intake air temperature: 40° C
Tier IV is composed of multiple active power and cooling distribution paths, has redundant components (TD); W2A: water-to-air charge air cooling (TB)
TA-Luft:
and is fault tolerant, providing 99,99 % availability. (4) Power available up to 32°C intake air temperature/ // Site altitude above sea level: 100 m
400m site altitude above sea level // Intake air temperature: 25° C
(5) Power available up to 25°C intake air temperature/ NEA Singapore:
Tier I Tier II Tier III Tier IV 100m site altitude above sea level // Site altitude above sea level: 100 m
(6) All levels in accordance with European Noise
// Intake air temperature: 40° C
Delivery paths One One One Active + Two Active Directive (2000/14/EC)
Available power for diesel generator sets –
One Passive (7) cos  = 1,0 in accordance with VDE 0530 REM 60Hz/1800 rmp
Redundant components No Yes Yes Yes with 400 V alternator Standard:
(for active path) (for two active paths) // Site altitude above sea level: 400 m
(8) Heat output from engine cooling with tolerance
Simultaneously maintainable No No Yes Yes of ± 8%
// Intake air temperature: 25° C
Fault tolerance (single event) No No No Yes
(9) Heat output from exhaust (exhaust cooling to X°C)
Compartmentalisation No No No Yes with tolerance of ± 8%
Availability 99,67 % 99,74 % 99,98 % 99,99 %
(10) Performance data in accordance with
Suitable MTU Onsite Energy Standby Power (3D) Data Center Continuous Power (3F) ISO 3046/I-2002 with tolerance of 5%
application Standby Power with Overload (3E) Continuous Power (3A)
(11) Referenced methane number
Prime Power (3B)
Grid Stability Power (3G)
Mission Critical Power (3H)
For complete definition see http://uptimeinstitute.com/

60 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 61


Website. Local support.
Tools and Downloads. Worldwide.

From PS-SPEC sizing software to building information models (BIM) and The reliability and performance of your MTU Onsite Energy systems are crucial for your success and
spec sheets for all our products, MTU Onsite Energy has the tools and competitiveness. We are committed to your support. Our convenient global service network provides you
software to assist you with all aspects of your project design. Case studies this assurance. Whenever and wherever you need expert support, MTU Onsite Energy specialists are
and technical articles are also available for download to reference existing available. This continuous and long-term care ensures high availability, dependability and efficiency
MTU Onsite Energy projects. throughout the lifecycle of your equipment. We ensure that you receive individualized support from our
extensive, global network of authorized MTU Onsite Energy service partners – anywhere, anytime.
PS-SPEC Power System Sizing and Specification Software:
PS-SPEC Power System Sizing and Specification is a powerful, fully-featured
sizing and specification program for generator sets suitable for projects of
any size. PS-SPEC is a tool for consulting engineers, contractors, and other
professionals involved in the design, application load analysis or installation
of generator sets. PS-SPEC asks you to supply basic information about your
project requirements and then provides you with all the information you need
to select the appropriate equipment.

For detailed product information, please visit our website: To find your local dealer, please visit our website:
www.mtuonsiteenergy.com/products/diesel-generator-sets www.mtuonsiteenergy.com/find-a-dealer

62 / //  / MTU Onsite Energy MTU Onsite Energy / //  / 63



MTU Onsite Energy

www.mtuonsiteenergy.com
A Rolls-Royce Power Systems Brand
3052111 | Edition 01/16 | ENC 2016-01 CM | Subject to alteration due to technological advances. | Printed in Germany on chlorine-free bleached paper.