Вы находитесь на странице: 1из 2

INDONESIA NATIONAL STANDARD OF ENVIRONMENTAL AIR

QUALITY
(Ministry of Environment Decree No. 4 year 1999)

Measure
Quality Checking
No. Item ment Apparatus
Standard Method
Time
1 hour 900μg/Nm3
Sulfur dioxide Basic Red
1 24 hours 365μg/Nm3 Spectrophotometry
(SO2) 9
1 year 60μg/Nm3
1 hour 30,000μg/Nm Nondispers
3
Carbon 24 hours ive infrared
2 NDIR Sensor
monoxide (CO) 1 year 10,000μg/Nm technology
3
(NDIR)
1 hour 400μg/Nm3 B.E
Nitrogen
3 24 hours 150μg/Nm3 Saltzman Spectrophotometry
dioxide (NO2)
1 year 100μg/Nm3 Method
1 hour 235μg/Nm3 Chemilumi
4 Ozone (O3) Spectrophotometry
1 year 50μg/Nm3 nescence
Hydrocarbon 3 hours 160μg/Nm3 Flame
5 Gas chromatography
(HC) ionization
24 hours 150μg/Nm3 Hi-Volume
<10μm
6 Gravimetry Gravimetric Sample
particles (PM10) Collector

24 hours 65μg/Nm3 Hi-Volume


<2.5μm
1 hour 15μg/Nm3 Gravimetry Gravimetric Sample
7 particles
(PM2.5) Collector

24 hours 230μg/Nm3 Gravimetry Hi-Volume


Total
1 hour 90μg/Nm3 Gravimetric Sample
8 Suspended
Solids (TSS) Collector

24 hours 2μg/Nm3 Hi-Volume


1 hour 1μg/Nm3 Gravimetry Gravimetric Sample
9 Lead (Pb) Extraction Collector
ashing Atomic Absorption
Spectrophotometer
10 Settled dust 30 days 10 ton/Km2/ Gravimetry Dust Tank
month
(settlement)
20
ton/Km2/mont
h (Plant Area)
24 hours 3μg/Nm3
90 days 0.5μg/Nm3 Ion- Dust collecting flask
Total fluoride
11 Selective or Continues Flow
(F)
Electrode Analytical System
(CFA)
30 days 40μg/100cm2
Colorimetr Lime sand filter
12 Fluorine index (Lime sand
y paper
filter paper)
Chlorine and 24 hours 150μg/Nm3 Dust collecting flask
Ion-
chlorine or Continues Flow
13 Selective
dioxide Analytical System
Electrode
(CFA)
Sulphuric acid 30 days 1mg
Colorimetr Lead peroxide
14 index SO3/100cm
y candle
(lithanode)
Notes:
 PM2.5 has started to be implemented on 2002。
 Analysis for item number 11 to 14 can only be conducted in Laboratory near Plant
Area