Вы находитесь на странице: 1из 4

Automation & Information Systems

e-terraanalyst ™
Automatic fault analysis and user
notification for predictive
maintenance

Technology Solutions Needed for Universal


Challenges

Department heads today face more demanding


challenges than ever before. Older infrastructures
are asked to work harder. In many companies,
technical staffing in operational areas gets smaller
every year, not larger.

Legacy systems were never designed nor intended


to address today’s critical Information Technology
(IT) performance and reliability issues. Legacy
systems typically address the most valuable asset
data only as historical data. While these systems
move the data, they fail to perform the meaningful
analysis needed.

Working smarter and not harder is no longer a


luxury; it has become a staple of department
survival. Improved T&D management, through IT,
has become a critical component and a powerful
ally in the battle to meet these daily challenges.

From the perspective of the bottom line, every


utility is facing similar challenges today. You’re
trying to squeeze extra life and higher capacity
out of aging equipment, and you’re attempting to
do this with ever-shrinking staffs. Dealing with
these universal challenges is why so many
invest in substation automation.

PERFORMANCE AND RELIABILITY INFORMATION MANAGEMENT


THAT MEETS THE NEEDS OF EVERY DEPARTMENT

At AREVA T&D we understand that all of your departments need to work together to
determine what specific analysis actions will mitigate, or even prevent, outage
events and save substantial amounts of time, money and embarrassment.
Customer benefits
• Increases productivity With e-terraanalyst, no one gets left behind. Your Operations Department gets fault
• Improved reliability reporting and lightning correlation; your Systems Protection Department gets
• Improved restoration times automated fault reporting and fault clearing analysis; your Maintenance Department
gets apparatus predictive maintenance and asset management; your Power Quality
• Reduced maintenance costs
Department gets fault and power quality identification and reporting; Your Customer
Services Department gets useful Commercial and Industrial customer data like
energy use and power quality.

T&D
e-terraanalyst ™
Automatic fault analysis and user notification
for predictive maintenance

INCREASES PRODUCTIVITY REDUCED MAINTENANCE COSTS

Automatic collection and analysis of data frees You’ll get better visibility of which equipment is starting
engineers from time consuming data collection and to break down and needs work, allowing a lower cost
manual analysis, allowing them to concentrate on maintenance visit instead of equipment replacement
solving problems. after a catastrophic failure.

IMPROVED RELIABILITY SAVE TIME AND MONEY WITH AREVA T&D

Automatic data analysis makes you aware of problems AREVA T&D monitors power system equipment such as
sooner. Instead of doing a post-failure analysis, transformers, breakers, and other utility assets to
e-terraanalyst proactively looks for specific conditions ensure they remain in peak operating condition and to
that cause problems on your system, and notifies you minimize usage interruptions.
of potential problems, allowing you time to fix possible
Our solutions automatically track equipment operation
issues before they cause an outage.
parameters and detect abnormal operating conditions.
This allows your substation personnel to take
IMPROVED RESTORATION TIMES immediate action to improve reliability and extend
equipment life. And, our system integrates easily with
When a fault occurs, the automatic analysis can provide other maintenance and asset management IT solutions,
you with timely information that has previously taken allowing condition-based maintenance strategies.
hours to collect and review. This can directly affect your
We use all the data available and compile it to create
restoration time statistics – and your bottom line.
meaningful performance and reliability information. In
addition, we provide state-of-the-art tools that are easy
to use so that you can utilize this information to save
time and money.

“ Reducing costs and


improving reliability
through the intelligent
analysis and correlation
of untapped system data”
How do we do it? > Active Fault Analysis

> We collect all T&D measurement data, not just Active Fault Analysis is retrieval, analysis and
operational data correlation of fault data. This data is used to produce
> We provide a method to communicate this a customized report that is the same, regardless of
information to all of the departments which manufacturer’s equipment reported the fault.
> We manage actively and analyze the
non-operational data > Active Power Quality
> We deliver reports via the web, operator interface
or proactive emails Active Power Quality is the retrieval and analysis of
> We tailor active analysis modules to address data to produce a full power quality report. These
your system’s specific requirements for: power quality reports can then be archived and
> Faster restoration of remote equipment accessed when needed.
> Automated asset predictive failure reporting
> Automated fault and event analysis > Active Substation
> Automated power quality reporting
Active Substation is a system that monitors the health
Our software comes complete with the following modules of all key components running at the substation. This
to address all your substation automation needs. gives owners and operators faster alarming and
reporting when they need it.
> Active Asset Management

Active Asset Management is an active and


comprehensive analysis of non-operational data. This
data is used to generate reliability alarms if symptoms
of pending equipment failure are detected. The data is
also used to create reliability reports and customized
analysis reviews, to determine if equipment can be
remotely restored after a fault.

“ Designed to be ‘configured’ with the ability to address


your specific challenges assuring a return on
investment is obtained”

e- terra a n alyst

> Automatically > Operations


emails intelligent Fault reporting
reports Lightning

> System Protection


e-terraanalyst Automated fault reporting
Fault clearing analysis
O PER ATI O N A L DATA
> Maintenance
Apparatus predictive
Analysis Report maintenance Asset
Data via Engine Generator
API
Report, > Reliability and Power Quality
N O N O P ER ATI ON A L DATA Smart Fault and PQ identification
Chart
Analysis
Object or Action and reporting
Script
Library
> Customer Services
> Intergrated with C&I Information system
Energy use
Billing
e-terraanalyst supplies a fault chart for
faster transformer restoration

e-terraplatform > And/Or e-terracontrol


TECHNICAL SPECIFICATIONS

e-terraanalyst is a software system with four components:


>> Data collection
>> Data storage
>> Analysis
>> User Interface
All four components can run on a standard desktop computer,
or they can run on a set of distributed computers depending on
the size of the system and the number of users.

MINIMUM SYSTEM REQUIREMENTS

>> Pentium class or greater CPU


>> 128 Mb RAM
>> 100Mb hard disk space
>> SQL Server required for data storage

AUTOMATION-L3-E-TERRAANALYST-EN - © - AREVA - 2004. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA.
The other names mentioned, registered or not, are the property of their respective companies. - 3891982 RCS PARIS - Printed in USA.

Our policy is one continuous development. Accordingly


the design of our products may change at any time. Whilst
every effort is made to produce up to date literature, this
brochure should only be regarded as a guide and is
AREVA T&D Worldwide Contact Centre: intended for information purposes only. Its content do not
constitute an offer for sale or advise on the application of
http://www.areva-td.com/contactcentre/ any product referred to in it. We cannot be held responsible
Tel: +44 (0) 1785 250 070 for any reliance on any decision taken on its content
without specific advice.

www.areva-td.com

Вам также может понравиться