Вы находитесь на странице: 1из 3
KEMBANG ABADI SDN. BHD. ( Company No. : 476320-X ) "WELDER QUALIFICATION TEST Name NORIZAM BIN NORDIN @ KAMARUDIN Welder ID LEX/PI/WQT/KASB/004 WPS No. ‘WPS-LASB-O01 VC @ Pasport = 761204-08-5277 Date = 09-01-2019 ACTUAL VALUES, QUALIFICATION RANGE Process/Type : FCAW. FCAW Electrode (Single or Multiplie) NA [Current DCEP Position 2G, Weld Progression : Ni NA, Backing (Yes or No) YES ‘YES IMaterial/Spec DIR BASE METAL IN GROUP 1 Aceeptabl(YES) or (NO) GUIDED BEND TEST RESULTS Groove 2mm 3mm - 24mm Fillet: NA "ANY THICKNESS Thickness (Pipe or Tube) Groove NIA 3mm - 24mm Fillet NWA ANY THICKNESS Diameter (Pipe) Groove N/A > 600mm WITH BACKING Fillet NA > 6 600mm WITH BACKING Filler Metal eae ‘Spec No A520 A520 Class ETT. ETT-1 E-No 6 6 Gas/Flux Type : COR COR VISUAL INSPECTION S2 3 Sa FILLET TEST RESULT Appearance NA Fillet Size Fracture Test Root Penetration NA Macrotech NA |oeseribe the Location, Natureand Sie of any Crack or Tearing ofthe Specimen) inspected by NA JOrganization NAL RADIOGRAPHIC TEST RESULT Film Identification No. Result Remarks DMSB/KASB-WQT/RT-001-NO 3 PASS. interpreted by : MARDIANA MD LANA PCN L2 ‘Test Number JOrganization : DANAMIN (M) SDN BHD Date WE, THE UNDESIGNED, CERTIFY THAT THE STATEMENT IN THIS RECORD ARE CORRECT AND THE TEST WELD HERE PREPARED, WELDED AND TESTED IN CONFORMANCE WITH THE REQUIREMENTS OF CLAUSE 4, WELDING CODE - STEEL. ‘Authorized by KEMBANG ABADI SDN. BHD. (Company No. : 476320-X } "WELDER QUALIFICATION TEST Name LEONG MUN KIN Welder 1D. LEX/PLU/WQT/KASB/005 TC @ Pasport_; 760728-08-5521 WPS No. ‘WPS-LASB-001 Rev : 0 Date : 09-01-2019 VARIABLES ACTUAL VALUES, QUALIFICATION RANGE, ProcessiType : FCAW. FCAW Electrode (Single or Multiplie) : WA NA fCurrent, DCEP DCEP Position 2G ia |Weld Progression NA NA, ‘YES ‘YES ‘S275IR BASE METAL IN GROUP | Base Metal [Thickness (Plate) Groove 2mm 3mm - 24mm, Fillet NA ANY THICKNESS Thickness (Pipe or Tube) Groove N/A 3mm - 24mm Fillet NA ANY THICKNESS Diameter (Pipe) Groove NIA > 6 600mm WITH BACKING Fillet NA 5G 600mm WITH BACKING Filler Metal Spec No A520 Class ETIT-1 E7IT-1 F-No 6 6 COR Coz GUIDED BEND TEST RESULTS VISUAL INSPECTION Acceptabl(YES) or (NO) FILLET TEST RESULT Fillet Size NIN Macrotech Inspected by NA JOrganization NAL RADIOGRAPHIC TEST RESULT Film Identification No. Result Remarks DMSB/KASB-WQT/RT-001-NO 3 PASS lOrganization “: DANAMIN (M) SDN BHD JAWS D1.1/D1.1M(2015) STRUCTURA Interpreted by : MARDIANA MD LANA PCN L’ E, THE UNDESIGNED, CERTIFY THAT THE STATEMENT IN THIS RECORD ARE CORRECT AND TiiE TEST WELD HERE PREPARED, WELDED AND TESTED IN CONFORMANCE WITH THE. 2 ‘Test Number QUIREMENTS OF CLAUSE 4, KEMBANG ABADI a BHD. ( Company No. : 47632 "WELDER QUALIFICATION TEST Name :_JAKIRUL MONDAL Welder 1D LEX/PLWQT/KASB/006 VC @ Pasport - 15343990 WPS No, WPS-LASB-001 Rev = 0 Date = 09-01-2019 ‘VARIABLES ACTUAL VALUES QUALIFICATION RANGE. Process/Type FCAW FCAW Electrode (Single or Multiplie) NA {Current DCEP Position: 2G Weld Progression NA [Backing (Yes or No) : YES s IMaterial/Spec S275IR BASE METAL IN GROUP | Base Metal Thickness (Plate) Groove 12mm 3mm - 24mm Fillet NA ANY THICKNESS N/A 3mm - 24mm NA ‘ANY THICKNESS N/A > 9 600mm WITH BACKING, N/A > 9 600mm WITH BACKING A520 VISUAL INSPECTION ‘Acceptabl (YES) or (NO) GUIDED BEND TEST RESULTS a 33 St FILLET TEST RESULT Appearance N/A Fillet Size Fracture Test Root Penetration NA Maerotech {Describe the Location, Natareand Siz of any Crack of Tearing ofthe Specimen) Inspected by NA JOrganization NA RADIOGRAPHIC TEST RESULT Film Identification No. Result Remarks DMSB/KASB-WQT/RT-001-NO 3 PASS NA interpreted by : MARDIANA MD LANA PCN L2 ‘Test Number NA JOrganization : DANAMIN (M) SDN BHD. Date WE, THE UNDESIGNED, CERTIFY THAT THE STATEMENT IN THIS RECORD ARE CORRECT AND THE TEST WELD HERE PREPARED, WELDED AND TESTED IN CONFORMANCE WITH THE REQUIREMENTS OF CLAUSE 4, JAWS D1.1/D1.IM(015) STRUCTURAL-WELDING CODE - STEEL Raley Authorized by :

Вам также может понравиться