Вы находитесь на странице: 1из 7

NP 3231/735 3~ 480

Te chnical spe cification

[m] Head
92
88
84
80
76
72
68
64
60
82.1%
56
52
48
44
40 480 465mm
36
32
28
24
Note: Picture might not correspond to the current configuration.
20
16 Ge ne ra l

- Patented self cleaning semi-open channel impeller, ideal f or pumping in


12 most waste water applications. Modular based design with high
adaptation grade.
8
4
Impe lle r
0
0 40 80 120 160 200 240 280 320 [l/s] Impeller material Grey cast iron
Discharge Flange Diameter 200 mm
Suction Flange Diameter 250 mm
Wastewater Curve ISO Impeller diameter 465 mm
Number of blades 3

Ins ta lla tion: P - S e mi pe rma ne nt, We t


M otor

Motor # N0735.000 43-44-4AA-W 170KW


895
MAX. 2 CABLES
95-120mm¦
Standard
ADDITIONAL 150Kg
Required for 746 FM, all Stator v ariant 1
GUIDE BARS 3" cables
Frequency 50 Hz
REF. LINE 135 Rated v oltage 380 V
50 Number of poles 4
375 810
Phases 3~
2185

175
Rated power 170 kW
Rated current 310 A
Starting current 1900 A
Rated speed 1480 rpm
Power f actor
1910

1/1 Load 0.89


DN 200
3/4 Load 0.86
1/2 Load 0.79
Motor ef f iciency
40
345*
450

1/1 Load 93.0 %


695

Z
3/4 Load 94.0 %
340

Z
15° 1/2 Load 93.5 %
50
REF. LINE 1300 (TO FURTHEST POINT)
Configura tion
1730
390 320

355
250 REF. LINE *DIMENSION TO ENDS
200

Ø24(4X) OF GUIDE BARS


VIEW Z - Z
400
CL OF DISCH

500

Dimensional drwg
CP,NP 3 2 3 1 7 3 5 /7 4 5 /7 3 6 /7 4 6

Project Project ID Created by Created on Last update


1 0 /3 1 /2 0 1 8
NP 3231/735 3~ 480
Performance curve
Pump Motor
Discharge Flange Diameter 200 mm Motor # N0735.000 43-44-4AA-W 170KW Power factor
Suction Flange Diameter 250 mm 1/1 Load 0.89
Impeller diameter 465 mm Stator variant 1 3/4 Load 0.86
Number of blades 3 Frequency 50 Hz 1/2 Load 0.79
Rated voltage 380 V
Number of poles 4 Motor efficiency
Phases 3~ 1/1 Load 93.0 %
Rated power 170 kW 3/4 Load 94.0 %
Rated current 310 A 1/2 Load 93.5 %
Starting current 1900 A
Rated speed 1480 rpm
[m] Head
90
85
80
75 75 m
70
65
60
82.1%
55
50
45
40 480 465mm
35
30
25
20
15
10
5
0
[%] Pump efficiency
Overall efficiency 480 62.2 %
60 480 465mm
465mm
58.5 %
40
20
[kW]0 480
200
Pow er input P1 480 465mm
465mm (P1)
(P2)
Shaft pow er P2
150 129.1 kW
100 121.6 kW
50
0
NPSH-values 480 465mm
[m]
12
8
4 102.6 l/s 3.46 m
0 40 80 120 160 200 240 280 320 [l/s]
Wastewater Curve ISO

Project Project ID Created by Created on Last update


10/31/2018
NP 3231/735 3~ 480
Duty Analysis

[m] Head 1
94
92
90
88
86
84
82
80
78
76 75 m
74
72
70
68
66
64
62
60
58 82.1%
56
54
52
50
48
46
44
42
40 480 465mm
38
36
34
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
2 102.6 l/s
0
0 40 80 120 160 200 240 280 320 [l/s]
Wastewater Curve ISO

Curve issue 48

Indiv idua l pump Tota l

Pu mp s
r u n n in g Sp ecifi c
/System Fl ow H ead Sh aft p o wer Fl ow H ead Sh aft p o wer Pu mp eff. en er g y N PSH re

1 103 l/s 75 m 122 kW 103 l/s 75 m 122 kW 62.2 % 0.349 kWh/m³ 3.46 m

Project Project ID Created by Created on Last update


1 0 /3 1 /2 0 1 8
NP 3231/735 3~ 480
VFD Curve
[m] Head
92
88
84
80
76
72
68
64
60
82.1%
56
52
48 82.1%
44
40 480 465mm
36 82.1%
32 45 Hz
28 82.1% 40 Hz
24
20 82.1% 35 Hz
16 30 Hz
12
8
4
0
[%] Pump efficiency
70 Overall efficiency
60 30 Hz 35 Hz 40 Hz 45 Hz 480
480 465mm
465mm
50
40
30
20
10
[kW]0 Pow er input P1 480 465mm (P1)
200 Shaft pow er P2 480 465mm (P2)
160 45 Hz
120 40 Hz
80 35 Hz
40 30 Hz
0
NPSH-values 480 465mm
[m] 45 Hz
12 40 Hz
35 Hz
8 30 Hz
4

0 40 80 120 160 200 240 280 320 [l/s]


Curve ISO
Project Project ID Created by Created on Last update
10/31/2018
NP 3231/735 3~ 480
VFD Analysis
[m] Head 1
92
88
84
80
76 75 m
72
68
64
60
82.1%
56
52
48 82.1%
44
40 480 465mm
82.1%
36
45 Hz
32
28 82.1%
40 Hz
24
20 82.1% 35 Hz
16
30 Hz
12
8
4
102.6 l/s
0
0 40 80 120 160 200 240 280 320 [l/s]
Curve ISO

Pumps
running Specific
/System Frequency Flow Head Shaft power Flow Head Shaft power Pump eff. energy NPSHre
1 50 Hz 103 l/s 75 m 122 kW 103 l/s 75 m 122 kW 62.2 % 0.349 kWh/m³ 3.46 m
1 45 Hz 87.5 l/s 61.8 m 88.1 kW 87.5 l/s 61.8 m 88.1 kW 60.3 % 0.299 kWh/m³ 2.93 m
1 40 Hz 70.7 l/s 49.5 m 60.2 kW 70.7 l/s 49.5 m 60.2 kW 57.1 % 0.255 kWh/m³ 2.42 m
1 35 Hz 51.7 l/s 38.8 m 38.6 kW 51.7 l/s 38.8 m 38.6 kW 51 % 0.228 kWh/m³ 1.97 m
1 30 Hz 26.8 l/s 29.7 m 22.3 kW 26.8 l/s 29.7 m 22.3 kW 35 % 0.271 kWh/m³ 1.63 m

Project Project ID Created by Created on Last update


10/31/2018
NP 3231/735 3~ 480
Dimensional drawing

895
MAX. 2 CABLES
95-120mm¦
ADDITIONAL 150Kg
Required for 746 FM, all
GUIDE BARS 3" cables
REF. LINE 135
50
375 810

2185
175

1910

DN 200
40
345*
450

695

Z
340

Z
15°
50
REF. LINE 1300 (TO FURTHEST POINT)

1730
390 320

355
250 REF. LINE *DIMENSION TO ENDS
200

Ø24(4X) OF GUIDE BARS


VIEW Z- Z
400
CL OF DISCH

500

Dimensional drwg
CP,NP3231 735/745/736/746

Project Project ID Created by Created on Last update


10/31/2018
Version 10

NP 3231/735 3~ 480
Life cycle costs (LCC)
Total lifetime 15 Inflation rate (rate of price increases) 2%
Annual operating time 5600 Interest rate (for investment) 3%
Energy cost per kWh 0.00 USD
Power input P1

Total costs

0% 0.00 USD Energy


0% 0.00 USD Investment costs
0% 0.00 USD Installation & commissioning
0% 0.00 USD Operating cost
0% 0.00 USD Maintenance & repair
0% 0.00 USD Downtime
0% 0.00 USD Environmental
0% 0.00 USD Decommissioning

0.00
USD

First year costs

0% 0.00 USD Energy (1st year)


0% 0.00 USD Investment costs (1st year)
0% 0.00 USD Installation & commissioning (1st year)
0% 0.00 USD Operating cost (1st year)
0% 0.00 USD Maintenance & repair (1st year)
0% 0.00 USD Downtime (1st year)
0% 0.00 USD Environmental (1st year)
0% 0.00 USD Decommissioning (1st year)

0.00
USD

Disclaimer: The calculations and the results are based on user input values and general assumptions and provide only estimated
costs for the input data. Xylem inc can therefore not guarantee that the estimated savings will actually occur.

Project Project ID Created by Created on Last update


10/31/2018

Вам также может понравиться