MAIN TROUBLESHOOTING
GENERAL SAFETY INSTRUCTIONS IRON
Fault: the iron switch does not light up when pressed.
Cause: switch broken, power cord not properly inserted, lack of power supply.
 After the removal of the package make sure of the appliance’s integrity. In case of Action: replace switch, check power cord.
doubt do not operate the appliance but take it to a qualified service person for examina-
Fault: after some minutes, the iron is still cold.
tion and repair. Plastic bags, polystyrene, etc…, must be kept out of the children’s Cause: iron switch is on OFF position, thermostat knob is set to a low temperature.
Action: turn on iron switch, set thermostat knob to a higher temperature. If iron is still
reach. cold, replace thermostat.
 Before connecting appliance, make sure that data on the plate are the same as the power
Fault: the temperature of the iron is too high.
supply network. The voltage appliance is of 230V monophasic with a plug of 16A+T. Cause: thermostat is faulty or temperature setting is too high.
Action: regulate or replace the thermostat.
 Plug appliance into grounded outlet of sufficient power as provided for by the safety
regulations in force. Fault: iron gives out water or wet steam.
Cause: too much water in the boiler.
 Do not touch appliance with wet or damp hands. Action: press the steam button on the iron until you get water.
Cause: too much water in the boiler because the water sensor in damaged.
 Always disconnect appliance from electrical outlet when not in use. Action: press the steam button on the iron until you get water.
Cause: the water sensor in the boiler is damaged, the control board does not work.
 This appliance is only and exclusively for its intended use so the manufacturer can not Action: check and clean the water sensor, check the control board.
be held responsible for any probable damage due to an illegitimate use.
Fault: steam getting out from the iron is too dry.
 Never unscrew the safety valve cap during use. Cause: the thermostat knob is set to a high temperature or thermostat is faulty.
Action: set thermostat knob to a lower temperature or replace thermostat.
 Before cleaning and maintenance make sure that appliance is disconnected from outlet.
Fault: when you press the red thumb switch, you do not get any steam.
Do not wash the appliance, do not immerse in water. Before filling the boiler, make Cause: coil is burned, switch is defective, power cord is damaged.
sure that appliance is unplugged. Action: replace coil, switch and power cord.
 In case of failure or operational defect, turn off appliance, disconnect from electrical BOILER
Fault: the pump does not start, the pump does not stop.
outlet. Do not disassemble or attempt to repair the appliance. Incorrect re-assembly or Cause: system default.
repair could cause a risk of fire, electric shock, or injury to persons when the appliance Action: turn off the appliance and empty the boiler, than start again.
Cause: the water sensor in the boiler is damaged, the control board does not work.
is used. Any repair must be executed by qualified service persons authorized by the Action: check and clean the water sensor, check the control board.
manufacturer. Ask for exclusive use of original spare-parts. Fault: the water tank is full but the sound alarm does not stop.
 Installation must be executed according to manufacturer’s instructions (space for venti- Cause: distilled water was used, the water hose or the control board does not work.
Action: check the water. Check the water hose and clean the electrical contacts on the
lation, room temperature). edge.
 Do not operate appliance with damaged cord or hose, but let it made replaced. Fault: the pump works but it does not load the boiler.
Cause: the vent valve on the boiler does not work, the limestone blocks the water inlet.
 Do not remove safety device and protective cover. Action: check the vent valve on the boiler and the water inlet under the boiler
 Before servicing make sure that appliance is unplugged from electrical outlet.
Fault: after having turned on the boiler switch and waited 15 minutes the steam ready
 The non-observance of the above OPERATING AND SAFETY INSTRUCTIONS indicator lamp does not light up.
Cause: heating element has blown, boiler is empty, pressurestat is faulty, light burned
could prejudice safety. out.
Action: check heating element, if burned replace it. If not, check pressurestat and ther-
mostat’s control over heating element.
Have a good job.
PLS NOTE: ALL REPAIRS OR REPLACEMENTS ARE TO BE MADE BY QUALI-
FIED SERVICE PERSONS.

2 7
activated. During the alarm the machine stops working. To work again CONTENTS AND LABELS
fill in the tank. Pc. 1 Iron table complete with steam generator
 When finished ironing, turn off the boiler and iron, switches (9), (10) , Pc. 1 Professional steam iron
(11) and unplug the machine. It is not necessary to pour out remaining Pc. 1 Cord holder
water from boiler. Just empty the boiler once a month.

MAINTENANCE:
EMPTYING AND CLEANING THE BOILER
 Unplug the machine and unscrew the safety valve cap counterclockwise
half a turn to release all pressure in the boiler.
 Unscrew the safety valve cap half a turn to release all pressure in the
boiler.
 When the boiler is cold and unpressured open the tap (18), under the
boiler to pour out the water.
 It is not necessary to pour out all remaining water any time you finish
ironing. It is enough to make this operation once a month. It is important
to unscrew the safety valve cap half a turn to release pressure.

WHEN FINISHED WORKING, TURN OFF ALL THE SWITCHES,


UNPLUG THE APPLIANCE AND KEEP IN A DRY PLACE.
CONSUMER NOTICE:
The BIEFFE product you have purchased is subject to Directive 2002/96/EC of the Euro-
pean Parliament and the Council of the European Union on waste electrical and electronic
equipment (WEEE) and, in jurisdictions adopting that Directive, is marked as being put on
the market after August 13, 2005, and should not be disposed of as unsorted municipal
waste. Please utilize your local WEEE collection facilities in the disposition of this product
and otherwise observe all applicable requirements.

CAUTION
DO NOT REMOVE SAFETY DEVICE AND PROTECTIVE COVER
BEFORE MAINTENANCE AND SERVICE MAKE SURE THAT APLLIANCE IS
UNPLUGGED FROM ELECTRIC OUTLET AND BOILER IS COOL AND NOT UN-
DER PRESSURE.
6 3
3 INSTALLATION AND STARTING UP
 Stand the cabinet table (B) in a safe place. Pull up the board (A) and
block it with the hook (C). Pull out the legs (D) and the cloth holder (E).
7 Connect the cord holder (F).
 Screw the box cover (1) to the wiring box (2).
 Connect the boiler cable power (3) to the power socket behind the wiring
box.
8  Connect the iron cables to the iron power socket (7) and to the solenoid
14 valve (8) under the working surface.
10 6
 Screw the safety cap (6),do not overtighten. Be sure that the draining tap
12 (18) is closed.
11
 Fill in the water tank (4) (Note: do not use distilled water). Place under
F
18 the boiler and insert the water hose (5) in it (Note: the water hose must
get always in touch with the water).
1  Plug into groud outlet.
Legenda  Turn on the the iron switch (10) and the first heater switch (11). If the
A Ironing board A boiler is empty, a pump starts to load it with water from the tank.
B Cabinet 2
C  Turn on the second heater switch (12) to get the high temperature faster
C Hook for board
D Legs and a stronger and longer steam jet.
E Cloth holder 9  Before working, wait until the pressure gauge 8 reaches 3atm.
F Cord holder G  When the pressure gauge (14) reads approximately 3 BAR, you are
G Power cable B 16 ready to iron.
1 Box cover
2 Wiring box E
3 Boiler power cable 5 OPERATING INSTRUCTIONS
4 Water tank  To get steam, press the red thumb switch (15). The first time you press,
5 Water hose 4
6 Safety cap point the iron away from the garment, in a safe direction and press the
7 Iron power socket D red thumb switch on the iron to eliminate any condensate from the iron.
8 Solenoid valve
9 General power 17  The volume of steam can be controlled turning the flow control knob
10 Iron Power Switch (normal position is half-open) in the solenoid valve under the working
11 Boiler Switch
12 End of water indicator surface.
13 Iron Thermostat Knob  The knob (16) operates the heating element of the ironing table.
14 Pressure Gauge 15
15 Iron Steam Switch  To operate the vacuum motor push the pedal (17).
16 Ironing Board Thermostat Knob 13  When the the boiler is going to be empty, the pump recharges the boiler
17 Vacuum Motors Control
18 Tap to empty the Boiler with water from the tank (4). When the tank is empty, a sound alarm is