Вы находитесь на странице: 1из 2

PACKAGE : THREE PHASE TEST SEPARATOR

CLIENT : XXXX

DOCUMENT TITLE :
INSTRUMENT DATASHEET- PRESSURE CONTROLLER

SEPL PROJECT REFERENCE: TYPICAL DATASHEET

0 27/12/2014 INITIAL ISSUE JS VCD KM


Rev. Date Description By Chkd. Appr.
Title Document Number
THIS DOCUMENT SHALL NOT BE REPRODUCED, COPIED, LENT, DISCLOSED,
PUBLISHED OR DISPOSED OF DIRECTLY OR INDIRECTLY NOR USED FOR ANY
PURPOSE OTHER THAN FOR WHICH IT IS SPECIFICALLY FURNISHED, EXCEPT AS INSTRUMENT DATASHEET- SEPL-PC-00
EXPRESSLY AUTHORISED IN WRITING BY SPARKLET ENGINEERS PVT. LTD.
PRESSURE CONTROLLER
Page 1 of 2
Rev Date Description By Chkd Appr

0 27/12/2014 INITIAL ISSUE JS VCD KM

Client : XXXX Destination: XXXX

Project Ref: XXXX Package: THREE PHASE TEST SEPARATOR

Equip. Item: PRESSURE CONTROLLER Tag No: REFER BELOW

GENERAL

1 TAG NO. PC 001

2 FUNCTION TRANSMIT & CONTROL

3 SERVICE GAS

4 CASE MFR STD

5 MOUNTING YOKE

6 ENCLOSURE CLASS IP 65 MINIMUM

7 POWER SUPPLY N /A

8 CHART N /A

9 CHART DRIVE N /A

10 SCALES N /A

PROCESS DATA

11 FLUID HC VAPOUR

12 OPER / DESIGN PRESSURE (PSIG) 1330 / 1440

13 OPER / DESIGN TEMPERATURE (DEG F) 122 / 250

14 DP RANGE 400" WC

15 Transmitter Output -

CONTROLLER

16 CONTROL MODES P+I

17 ACTION REVERSE

18 AUTO-MAN SWITCH MFR STD

19 SET POINT ADJ. MANUAL

20 OUTPUT 6-30 PSIG

ELEMENT

21 SERVICE GAS

22 ELEMEN TYPE BOURDON

23 MATERIAL 316 SS

24 RANGE VTS

25 PROCESS CONNECTION 1/4" NPT

ALARMS

26 ALARM SWITCH N /A

27 FUNCTION -

OPTIONS

28 FILTER REGULATOR REQUIRED

29 INPUT SUPPLY GAUGE REQUIRED

30 OUTPUT GAUGE REQUIRED

31 MFR. MODEL NO. FISHER C1

32 QUANTITY 1 No.

THIS DOCUMENT SHALL NOT BE REPRODUCED, LENT, DISCLOSED, PUBLISHED OR Title Document
DISPOSED OF DIRECTLY OR INDIRECTLY NOR USED FOR ANY PURPOSE OTHER THAN
SEPL-PC-00
FOR WHICH IT IS SPECIFICALLY FURNISHED, EXCEPT AS EXPRESSLY AUTHORISED IN INSTRUMENT DATASHEET- PRESSURE
WRITING BY SPARKLET ENGINEERS PVT. LTD. CONTROLLER
Page 2 of 2