Вы находитесь на странице: 1из 10

R3 – DEPROPANIZER

Components: C1 – nC8
FP: PengRobinson

Stream (Tower Feed)


T = 90 oF
P = 217.28 Psia
F = 100 lbmole/hr
xC1= 0.1955
xC2= 0.1462
xC3= 0.1058
xiC4= 0.1076
xnC4= 0.0983
xiC5= 0.0891
xnC5= 0.0768
xnC6= 0.0903
xnC7= 0.0517
xnC8= 0.0387

Column Distillation (Depropanizer)


N = 10
Inlet: TowerFeed (5)
Ovd: Ovhd (total Reflux)
Bttm: Bttms
CondQ dan RebQ
PReb = 205 psia, T = 200 oF (P = 0)
PCond = 200 psia, T = 40 oF (P = 0)
Spec:
Reflux Ratio, Condenser, Molar , 1 (active)
C3inBttms, Reboiler, Mole Fraction, Liquid, 2e-2, Propane (active)
Reboiler duty, Reboiler, 7.5e5 (est)
DEBUTHANIZER

Component: C3, iC4, nC4, iButene, iC5, nC5, nC6, nC7, nC8
FP : PengRobinson

Streams
Variable Feed1 Feed2
Temperature (F) 300 140
Pressure (Psia) 207 206
Flow (lbmole/hr 247.8 145.9
xC3 0.028 0.0198
xiC4 0.2016 0.2124
xnC4 0.2122 0.2124
xi-Butene 0.2419 0.0104
xiC5 0.1368 0.1409
xnC5 0.1795 0.1409
nC6 0 0.0927
nC7 0 0.0942
nC8 0 0.0763

Distillation Column (Debutanizer)


n=15, standard
Inlet Streams
Feed2 (4)
Feed1 (8)
Ovhd: Butanes
Bttm Outlets C5+
Pressure PCond= 205, PReb= 206.7 psia, P= 0

Condenser: Full
Energy: QCond, QReb

Specs:
C5 in Top, Condenser, Mole Fraction, Liquid, 1.798e-2, iC5, nC5
Reboiler Duty, Reboiler, 7.364e6 BTU/hr.
LPG

Komponen: N2, CO2, C1, C2, C3, iC4, nC4


FP : PR

MIX-100
Inlets: Feed 1 dan Feed 2
Outlet: MixerOut
Parameter: Equilize All

Variables Feed1 Feed2


Temperature (F) 60 60
Pressure (psia) 600 600
Molar Flow (lbmol/h) 658.8 439.2
xN2 0.01 0.0179
xCO2 0.01 0
xC1 0.6 0.6244
xC2 0.2 0.1666
xC3 0.1 0.1136
xiC4 0.04 0.0431
xnC4 0.04 0.0345

Separator (InletSep)
Inlet: MixerOut
Ovd: SepVap
Bttm: SepLiq

Valve (SepValve)
Inlet: SepLiq
Outlet: SepExit
P = 25 psia

HE (Gas/Gas)
Tube: SepVap  CoolGas (P = 10 psia, TCoolGas=43.96)
Shell: LTSVap  SalesGas ((P = 10 psia)
Parameter: Calculate Ft flow

Cooler (Chiller)
CoolGas  Cold Gas (Energy: (C3Duty = 1.076e6 BTU/hr)

Separator (LTS)
Inlet: ColdGas
Ovd: LTSVap
Bttm: LTSLiq

Valve (LTSValve)
LTSLiq  LTSExit (P = 5 psia)

MIX-101
Inlets: SepExit and LTSExit
Outlet: TowerInlet
Parameter: Equilize All

Valve (TowerValve)
TowerInlet  TowerIn (P = 363 psia)

Heater (Heater)
TowerIn  TowerFeed (Energy: HeaterQ, P = 10psi, TTowerFeed = 24.66)

Distillation Column (DePropanizer)


N = 10
Inlet: TowerFeed (5)
Ovd: Ovhd (total Reflux)
Bttm: LiquidProd
CondDuty dan RebDuty
PReb = 202.4 psia, T = 200 oF (P = 0)
PCond = 201.8 psia, T = 40 oF (P = 0)
Spec:
Reflux Ratio, Condenser, Molar , 1 (active)
Propane Fraction, Reboiler, Mole Fraction, Liquid, 2e-2, Propane (active)
Overhead Vapor Rate, Ovhd, Molar, 219.6 (est)
Comp Loop

Component: C1, C2, C3, nC4, nC5, nC6, H2O


Fluid Package: PR

Valve 103
15 → 2,
T15 = 25 oC
P15 = 105 kPa
F = 290.55 kmol/h
xC1 = 0.9
xC2 = 0.05
xC3 = 0.02
xnC4 = 0.01
xnC5 = 0.005
xnC6 = 0.005
xH2O = 0.01

V100
2 → 17 (ovd)
→ 16 (Bttm)

Mix100
Inlet: 17,1 → 3

K100: 3 → 4 (Q-100, eff. ad.= 72.053, P4=300 kPa)

E100: 4 → 5 (P = 0, T5 = 46.92)

MIX101: 5,6 → 7 (T6 = 25, M6 = 1000 Kg/h, xH2O = 1)


V101
7 → 10 (ovd), 8 (bttm)
Level (19.62%)

Tee100
10 → 11, 13 (Split 11 = 1)

Valve102
8→9
P9 = 257.6 kPa

Valve101
11 → 12 (P12 = 257.6 kPa)

RCY1
13 → 14 (F14=0)

Valve100
14 → 1
P1 = 98.3
Absorption Dehydration

Component: N2, CO2, H2S, C1, C2, C3, iC4, nC4, iC5, nC5, TEGlycol, H2O
Fluid package: PR
Stream Composition (mol fraction)
Name Inlet Gas TEG Feed Water to Make UP TEG
Saturate
N2 1.00e-003
CO2 2.84e-002
H2S 1.55e-002
C1 0.8989
C2 3.10e-002
C3 1.48e-002
iC4 5.90e-003
nC4 3.00e-003
iC5 1.00e-003
nC5 5.00e-004
TEGlycol 0.00000 0.99 (%wt) 0.99
H2O 0.00000 0.01 1 0.01

PVT Data
Name Inlet Gas TEG Feed Water to Gas+H2O
Saturate
Temperature 85 120 85
(F)
Pressure (Psia) 900 900

Molar Flow 1098 8.044 1.1


(lbmole/hr)
Name Regen Feed MekeUp TEG TEG To Pump Pump Out
Temperature 220 60
(F)
Pressure (Psia) 16

Liq Flow
(bbl/d)

Name TEG to Recy TEG Only Water DewPt


Temperature 120 7 7.556
(F)
Pressure (Psia) 895 895

Saturate (Mixer)
Inlet: Inlet Gas
Water to Saturate
Outlet: Gas+H2O
Equalize All

FWKO (Separator)
Inlet: Gas+H2O
Outlet: Gas to contactor (Vapor)
Water Out
Volume : 70.63Ft3
Liq Level: 50%

T100 (Absorber Column)


Top Stage Inlet: TEG Feed
Bottom Stage Inlet: Gas To Contactor
Vapor Outlet: Dry Gas
Liquid Outlet: Rich TEG
Number of trays: 14
P1= 885.3 psig
Pn = 885.3 psig

VLV-100 (Valve)
Inlet: Rich TEG
OutLet: LPTEG

L/R Exch (HE)


Tube In: Regen Bttms
Tube Out: Lean from L/R
Shell In: LP TEG
Shell Out: Regen Feed
HE Design (End Point)
Tube side pressure drop: 0.1 psi
Shell side pressure drop: 10 psi

TEG Regenerator (Dist. Column, 1 stage )


Regen Bttms (Bottom)
Energy: Reb Q
Condenser (Full Reflux)
Sour Gas (Vap)
Energy: Cond Q

Design Spec
TEG bottoms (TEG in battoms, reboiler, liquid, mass fract, 0.99) (active
Reboiler Temperature 400 oF (active)
Reflux Ratio 3.00 (estimate)
Sour Gas Rate 329.4 lbmole/hr (estimate)

MakeUp (Mixer)
Inlet: Lean from L/R
MakeUp TEG
Outlet: TEG to pump
Equilize All

P-100 (Pump)
Inlet: TEG to pump
Outlet: Pump Out
Energy: Pump Q
Adiabatic Eff. 75%

E101 (HE)
Tube In: Pump Out
Tube Out: TEG to Recy
Shell In: Dry Gas
Shell Out: Sales Gas
HE Design (End Point)
Tube side pressure drop: 10 psi
Shell side pressure drop: 5 psi

Remove TEG (Component Splitter)


Inlet: Sales Gas
Outlet: TEG Only (Ovd)
Water DewPt (Bttm)
Energy: Split Q
Split All zero except TEG Only=1

V-101 (Separator)
Inlet: Water DewPt

Out: Gas Out (Vap)


XS H2O (Liq)
Vol. 70.63 ft3

Adjust
Adjust Variable: Water DewPt Temperatur
Object Variable: XS H2O (Comp Mass Flow) = 0.02 lb/hr

RCY-1 (Recycle)
Inlet: TEG To Recy
Outlet: TEG Feed