,,No Maintenance
The combination of these benefits and virtually zero Rue J.H. Cool 19a l B-4840 Welkenraedt
maintenance requirements, give the user a very low Tél.: +32 (0)87 899 799 l Fax: +32 (0)87 899 790
“Cost of Ownership”. E-mail: info@flow-tronic.com
www.flow-tronic.com
NON-CONTACT RADAR FLOW MEASURING SYSTEM Applications Technical specifications
How does it work ? General
Size (HxWxL) 183 x 140 x 422 mm
The RAVEN-EYE® is mounted above the water surface
Weight 3,85 kg (without cable, level sensor and mounting accessories)
and measures the flow velocity at the water surface
using a pulse wave radar and the flow depth with a
Sewer/Channel Networks Materials Enclosure: Polyurethane (PU), stainless steel
level sensor (ultrasonic, radar or pressure). The flow
rate is calculated applying the continuity equation:
Monitoring
Cable Lengths
Cable: Polyurethane jacketed
10, 20, 30 or length as needed up to 300 m
,,Large sewer channels Protection IP68
Q=vxA ,,Capacity studies Certifications CE, ATEX (option)
Temperature Range Operating: -20 to 50 °C
During each measurement cycle, the RAVEN-EYE®
,,Combined sewer overflow (CSO) studies Storage: -30 to 60 °C
makes thousands of individual velocity measurements ,,Inflow & infiltrations studies Power Required Input voltage: 4 to 26 VDC
which are analyzed and processed into an extremely Outputs 1 passive analog 4-20 mA (velocity only)
accurate average velocity measurement reading using ,,High velocity flows
Communication RS-485 (serial MODBUS ASCII open protocol) for use with PLCs
a dedicated digital signal processor making real-
,,Discharge RS-485 (proprietary protocol) for use with UNI-TRANS™, IFQ MONITOR™ or RTQ-Logger series
time spectral analysis. Average velocity is calculated
within the sensor by analyzing the surface velocity Field interchangeable: Automatic recognition between stationary or portable units
distribution and using a self-learning technology that Flow Accuracy ±5% of reading (typical : assumes pipe is 0 to 90% full)
doesn’t require theoretical modules nor site calibration.
Wastewater Treatment Plants Flow Measurement Method
,,Flow to treatment onversion from surface velocity to average velocity by analyzing surface velocity distribution using a self-learning technology that
C
doesn’t require theoretical modules nor site calibration.
,,Discharge Conversion of water level and pipe size to fluid area.
,,Plant effluent Multiplication of fluid area by average velocity to obtain the flow rate.