Te c h n i c a l D o c u m e n t a t i o n | V e r s i o n A . 6
MECHANICAL DRAWING
SUMMARY
Please note that the summary respect the order of mechanical drawing plan, saw on the
previous slide
Supplier: I-PEX
CONNECTOR MAPPING PREVIEW
Reference: 30046-160T-F
See next page for detailled view
M AT C H I N G C O N N E C T O R
Supplier: I-PEX
References:
straight: 30056-160T-F
right angle: 30047-160T-04F
Phased-array channel
ER1 to ER64 Phased-array probe channel 1 to 64
number 1 to 64
Phased-array channel
ER1 to ER64 Phased-array probe channel 1 to 64
number 1 to 64
C O N N E C T O R I N F O R M AT I O N CONNECTOR MAPPING
Supplier: FISCHER
Reference: DU101 A001
M AT C H I N G C O N N E C T O R
Our U.T connector is NimCAMAC standard. Many
supplier can provide matching connector.
We advice you to use one of this two :
Supplier: FISCHER
Reference: DU 101 A004 For electric safety reasons, only accessories approved
by M2M can be used with our system. Before purchasing
Supplier: LEMO any probe, please contact us.
Reference: GCA.00.255.LT
M2M use Micro-D 25 plug standard connector. Gekko system will be able to pulse ultrasound salvo at each
trigger pulse and count each of it. This input is also optocoupled.
Supplier: GLENAIR Your encoder must be able to deliver 10mA on 5V.
Reference: 654-M83513/01-DC • SYNCHRONIZE TWO GEKKO:
Synchro1 and Synchro2 are multipurpose I/O signal used for
M AT C H I N G C A B L E pulse synchronization. These two I/O can be configured as Input
or Output.
Supplier: MOLEX If configured as input, Gekko system « Pulse Repetition
Reference: 83424-9021 Frequency » can be managed be external system.
If configured as output, Gekko system can manage external
system at the same rhythm than his own internal « PRF ».
Synchronization option are not yet accessible in Gekko software.
- If the encoder output is differential this output is the opposite of encoder 1 output.
(needed current 10mA).
Encoder 1 phase A- Encoder 1 phase A negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
Encoder 1 phase B+ Encoder 1 phase B positive signal Connected to the encoder 1 output B (needed current 10mA).
- If the encoder output is differential this output is the opposite of encoder 1 output.
(needed current 10mA).
Encoder 1 phase B- Encoder 1 phase B negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
Encoder 2 phase A+ Encoder 2 phase A positive signal Connected to the encoder 2 output A (needed current 10mA).
- If the encoder output is differential this output is the opposite of encoder 2 output.
(needed current 10mA).
Encoder 2 phase A- Encoder 2 phase A negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
Encoder 2 phase B+ Encoder 2 phase B positive signal Connected to the encoder 2 output B (needed current 10mA).
- If the encoder output is differencial this output is the opposite of encoder 2 output.
(needed current 10mA).
Encoder 2 phase B- Encoder 2 phase B negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
Encoder 3 phase A+ Encoder 3 phase A positive signal Connected to the encoder 3 output A (needed current 10mA).
- If the encoder output is differencial this output is the opposite of encoder 3 output.
(needed current 10mA).
Encoder 3 phase A- Encoder 3 phase A negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
Encoder 3 phase B+ Encoder 2 phase B positive signal Connected to the encoder 3 output B (needed current 10mA).
- If the encoder output is differencial this output is the opposite of encoder 3 output.
(needed current 10mA).
Encoder 3 phase B- Encoder 2 phase B negative signal
- If the encoder output is classic one. This signal must be connected to encoder
ground.
This input is used if you want to manage ultrasound pulse salve timing with an
External Trigger+ Trigger positive signal external system. External system must generate 5V pulse signal. The output current
must be 10mA.
- If the external system who generate trigger signal have differencial output. You
need to connect negative output to « Gekko External Trigger- »
External Trigger+ Trigger negative signal
- If the external system who generate trigger signal have classic output. You need
to « Gekko External Trigger- » to external system ground.
DC5V +5V power supply This power supply can be used to power the user encoder ( 2A max.)
GND GEKKO ground Gekko ground must be connected to encoder or external system ground.
C O N N E C T O R I N F O R M AT I O N
Supplier: FISCHER
Reference: DEU 104-A037-130 (115098 ZGG0.958
M AT C H I N G C A B L E
Do not use another external power supply
Supplier: M2M
Reference: GEK_CAB.DC.WALL.ADAPTER
WAR N I N G
C O N N E C T O R I N F O R M AT I O N
Supplier: SCHURTER
Reference: 4802.2300
M AT C H I N G C A B L E
Any audio system with jack 3,5mm interface
B AT T E R Y I N F O R M AT I O N
WITHOUT WALL ADAPTER, BATTERIES ARE USED TO
PROVIDE GEKKO POWER :
Do not use another external power supply
• Gekko can work with only one battery plugged.
Supplier: M2M • If batteries have different charge level, the Gekko takes
power from the most filled one. The power is given by only
Reference: GEK_BATTERY
one battery even if two are plugged in the system.
• If the batteries have a certain level, the system takes half of
B AT T E RY C H A R G E R I N F O R M AT I O N needed power from the first battery and remaining power
from the second battery. The battery level decreases in
2 possibilities to recharge batteries : same way in the two batteries.
- Use the Gekko built in recharge system.
- Use an external dual charger : IF YOU CHOOSE TO USE EXTERNAL CHARGER SYSTEM,
THE BATTERY RECHARGE TIME IS BETTER : 4 hours for two
- Supplier: M2M batteries instead of 6 hours if you use built in charger system.
- Reference: GEK_DUAL_CHARGER
BATTERY STATUS :
You can check the batteries level even if the system is off.
System in charged, when you push the button, the LED are blinking.
ON/OFF :
If the system is frozen, you can push the ON/OFF button during 4 second to force the
power down.
OTHERS :
BATTERY
For others button see software user guide.
STATUS
ON/OFF
USB :
• The overload protection is set for 0,5A for each USB port.
VGA OUTPUT :
VGA
On this port, any VGA compatible screen or projector can be
plugged. The plugged screen will be automatically detected by
the Gekko system. The video shown on the VGA screen and the
Gekko screen are exactly the same (resolution: 1024x768).
C O N N E C T O R I N F O R M AT I O N
Supplier: SAMTEC
Reference: RPBE-01-01-E
M AT C H I N G C A B L E
Supplier: SAMTEC
Reference:
• Double end version :
RCE-01-G-XX.XX-D
• Blint cut version :
RCE-01-G-XX.XX-BC
(11) ACCESSORIES
Accessory Name Description Picture
(11) ACCESSORIES
Accessory Name Description Picture
BATTERY
Additionnal battery.
M2M ref : GEK_BATT
BATTERY CHARGER
External dual battery charger able to recharge 2
Gekko batteries in 4hours.
M2M ref : GEK_CHARGER
(11) ACCESSORIES
Accessory Name Description Picture
OLYMPUS SYSTEM
This cable is needed to connect an
ADAPTATOR
Olympus device to our Gekko
system.
M2M ref : GEK_CAB_DE15
(12) CLEANING
• Maintenance activities explained below allow you to maintain the good condition and good working of the machine. GEKKO requires little
maintenance. This chapter covers maintenance preventive and cleaning of the device.
• External surfaces of Gekko, that is to say the housing, protector of the LCD screen can be cleaned when it is necessary. This section describes
the procedures for proper cleaning the device. Make sure the unit is closed, the power cord is disconnected and the batteries are removed.
• Disconnect all cables and connectors and check that the protectors rubber are closed on all external GEKKO port. Make sure that the battery
compartment cover is securely closed. To restore the original appearance of the unit, clean the housing with a soft cloth. To remove stubborn
stains, use a damp cloth with a solution mild soap. Do not use abrasives or strong solvents which could damage the finish. Once you have
removed the protective connectors, make sure they are dry before connecting anything else. If the connectors are wet, dry it with a soft dry
cloth or let them air dry.
• Never use abrasives or strong solvents to clean the GEKKO screen. Clean with a damp cloth and washer fluid. If you have no washer fluid, use
a standard glass cleaner. If appropriate, use a soft brush to remove paper towel waste.
CONTACT US
contact@m2m-ndt.com