maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Technical Data
Page 2/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Data Export
Protocol Q-DAS®, QDA9, IPM 5.0 Environment
Format XML, CSV, PDF Operating temperature range °C 0 ... 45
Destination USB, Server Storage temperature range °C 0 ... 50
Medium USB, Ethernet IP degree of protection (EN 60529)
Visualization via VNC®, or DIM – Connector and cable running IP 53
Interfaces downwards
Ethernet TCP/IP 100 Base TX with 2 Port Switch – Standard rail version IP 20
USB 2x USB Host, 1x Device
BUS PROFIBUS DP, PROFINET, Display Module (DIM)
EtherCAT, EtherNet/IP, Size In 10.4
2 Port Switch Color yes
Servo connection Fieldbus master SERCOS III Touchscreen yes
Resolution Pixels 600 x 800 (SVGA)
Dig-In/Out Technology TFT-LCD
Norm DIN EN61131 Backlighting LED
Level state "0" V 0 ... 5 Supply voltage (of MEM) VDC 24
Level state "1" V 10 ... 30 IP degree of protection (EN 60529)
Number of inputs 16 – Front IP 65
Input current max. mA 5 (at 24 V) – Rear IP 53
Number of outputs 16 Operating temperature range °C 0 ... 45
Output current max. (per channel) mA 500 (at 24 V)
Output current max. (in total) mA 1500 (at 24 V)
Real-time Reactions
Channel-X (2) Ethernet TCP/IP
Switching signals, NO-PASS ms <1 Digital sensors: Data export
BREAK, INFLEXION, incremental, SSI Remote access
TUNNELBOX-X, TUNNELBOX-Y Channel cascading
5847B_003-272e-02.17
Channel-Y (1)
Transmitter ±10 V Fieldbus (1)
Power Supply EtherNet/IP
Voltage VDC 24 (18 … 30) Channel-Y (2) PROFINET
Strain gage sensors
Power consumption (typical) VA 45 EtherCat
Page 3/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
DIM MEM The DIM Cable Extender is inserted at the rear portion of the
MEM with Display Module display. The DIM Cable Extender is supplied with 24 V of power
The MEM and DIM can either be installed separately from (the display is then supplied by the DIM Cable Extender). The
each other, connected via the optional connecting cable DIM Cable Extender is connected to one or several maXYmos
Type 1200A161A2,5/5. units via an Ethernet cable.
… or they can be used as a compact unit. In this case the MEM
is inserted into the rear slot of the DIM, forming a secure me-
chanical and electrical connection:
Page 4/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Charge amplifier
Cable SERCOS III Cable
Piezoelectric safety zone box KSM18029160-5 1200A161A...
force sensor KSM18029161-1 (Cable length max. 5 m)
Configuration, parameterization,
evaluation and visualization
maXYmos NC Type 5847B...
Motor control
feedback
PC
Ethernet interface
CSV, Q-DAS®, PDF, XML,
Visualization via VNC®
Functional principle of an NC joining system using the NC joining module NCFH Type 2151B... and maXYmos NC Type 5847B...
PROFIBUS
PROFINET PLC
EtherNet /IP
Y X Y X Y t Y t Y X EtherCAT
5847B_003-272e-02.17
Networking/Multiview of maXYmos NC
Page 5/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Sequencer Mode
The maXYmos NC controls the NC joining module, via the
servo amplifier through the integrated sequence control (se-
quencer). An independent sequence can be defined for each
program. The sequence can be configured freely on the basis
of the elements described below. Measurement and evaluation
take place in the main routine. The 3 sub-routines can be used
to define other sequences and execute these independently of
the main routine. A total of 255 elements can be placed per
program.
Motion Element: this element serves to actuate the Input Element: when this element is activated, the
NC joining module, e.g. to absolute/relative positi- system waits for the configured digital input signal
on, or force. In addition, force regulation, deflection and then continues the sequence.
compensation or stopping on an external signal, or
the response to an inflextion point event can be Output Element: when this element is activated, the
configured. corresponding configured output is set on the de-
vice.
Wait Element: when the sequence reaches this ele-
ment, it is paused and acknowledgment must be ob- Home Position Element: this element is contained
tained from the PLC before the sequence continues. once in the sequence and defines the basic settings.
It is approached with the predefined speed when the
element is activated or via the fieldbus.
Label Element: this element provides interaction
with the PLC. In the process, the label number is Sequence End Element: this element indicates that
transferred to the PLC when the element Label is the sequence has been stopped. Subsequent ele-
activated. ments are no longer executed.
Measurement Start/Stop Element: this element IF/ELSE Element: this element permits a conditional
starts and stops the measurement. When measu- branch, i.e. a branch in the sequential program ac-
rement stops, evaluation is performed according to cording to the query condition or result.
the parameterized evaluation elements.
Piezo Operate Element: this element is used to per-
Timer Element: this element delays execution of the form a variable measurement measure/reset of the
subsequent element by the configured time. Use as a integr. charge amplifier included in the sequence.
dwell time under force, for example.
5847B_003-272e-02.17
Page 6/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Evaluation Procedure
A large number of evaluation elements (EOs such as "Evalu-
ation Objects") can be selected for evaluation of the curve
progression: Examples:
The measurement curve must not Type ENVELOPE The line may not be crossed. Type NO-PASS
cross the upper or lower line of the Otherwise, NOK and "NO-PASS"
envelope. This evaluation object is IO NIO real-time signal. IO NIO
easy to master.
The line must be crossed once. Type LINE-X The line must be crossed once. Type LINE-Y
An X-value at the point of An Y-value at the point of
intersection is monitored.
IO NIO intersection is monitored.
IO NIO
IO NIO IO
Y Y Y
X X
Entry and exit as specified. No Type UNI-BOX Evaluates the average of all Y-values Type AVERAGE
crossing of "closed" sides allowed. in the box region.
IO NIO IO NIO
Each side can be defined as entry
or exit.
Entry and exit as specified. Crossing Type TUNNELBOX-X Entry and exit as specified. Crossing Type TUNNELBOX-Y
of the "closed" sides generates a of the "closed" sides generates a
real-time signal.
IO NIO real-time signal.
IO NIO
IO NIO IO NIO
X X
Box detects significant curve Type GET-REF Evaluation criterion is the time Type TIME
features and their XY coordinates between the entry and exit points in
in the expectancy range. This a special box. IO NIO
information can be used as X1 X2
reference points for other EOs or Y2
as an input for the CALC object Y1
Evaluation criterion is the speed Type SPEED Object references two selectable Type CALC
between the entry and exit points in process values and performs
a special box. IO NIO calculations, e.g. the X-difference IO NIO
between two ripples, and evaluates
them.
5847B_003-272e-02.17
A defined gradient change is Type INFLEXION Provides NOK and online signal Type BREAK
expected within the expectancy in case of sudden gradient change
range (box) and can be used as a IO NIO within an expectancy range (box), IO NIO
further switching condition in the e.g. in case of tool breakage.
sequence.
Page 7/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
X X
Page 8/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Product Testing Example: Distance check between two snap- Front Panel Mounting
in points of a latch. The two GET-REF boxes supply the co- After removing the fixing bracket and rear frame, push the
ordinates of the snap-in points to the CALC objects. These display through the front panel opening. Then screw the frame
calculate and evaluate the distances in the X and Y directions. back on. The measuring module (MEM) can now be pushed
into the slot of the display module if required.
Note: Lengths
>5 m can be
implemented with
accessory DIM Cable
Extender Type
1200A163.
5847B_003-272e-02.17
Page 9/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
Dimensions
Zeichnung für Datenblatt / 003-126
Measuring and evaluation module (MEM)
77 137
33 22,5
28,2 54,4 16,8
Digital I/O
Reset
X14 X10
Power
X1
24 V
GND
I/O I/O
±10 V Device
D1 state
Uout USB
X2
Type 5700A31
X3
Channel X
0,5
35 EN 60715
X15 X11 X4
±10 V
Ethernet
X5
M3 x7
32,3
198
33
X6
Channel Y
X16 X12
Fieldbus
X7
±10 V
M3 x 6
In
X8
Out
Servo X18
Display
Profibus DP
82,85
82,85
82,5
X17
X9
Piezo X13
maXYmos NC D2
Type 5847
Längenmasse * ...0,5 >0,5...3 > 3...6 > 6...30 > 30...120 >120...400 >400..1000
-0,2 +0,25
weder kopiert noch vervielfältigt, noch an Drittpersonen
Winkelmasse kürz. Schenkel ...10 > 10...50 > 50...120 >120...400 >400...
Abmasse ±1° ±0°30' ±0°20' ±0°10' ±0° 5'
mitgeteilt oder zugänglich gemacht werden.
Page 10/11
This information corresponds to the current state of knowledge. Kistler reserves ©2016 ... 2017, Kistler Group, Eulachstrasse 22, 8408 Winterthur, Switzerland
the right to make technical changes. Liability for consequential damage resulting Tel. +41 52 224 11 11, Fax +41 52 224 14 14, info@kistler.com, www.kistler.com
from the use of Kistler products is excluded. Kistler is a registered trademark of Kistler Holding AG.
maXYmos NC – XY Monitor for Monitoring and Controlling NC Joining Modules, Type 5847B...
• Log explorer opens and interprets exported test records • SERCOS III connection cable,
• Generation of an Excel® statistical file with selected process length 5 m KSM18029160-5
values • Safety zone box cable,
• Cursor measurement, bundle presentation of curves, etc. (2 cables required), length 1 m KSM18029161-1
• Final Y(X) curves can also be presented as Y(t) or X(t)
• PDF print function for test records