USB Digital Endoscope User Guide

Model No: BGV-B001

Features:

� You can have this USB Endoscope to reach the place that you cannot reach but
you still need to.
� With ultra slim snake-type scope.
� With 6 LEDs around the end of the endoscope, so you still can see in a dark
environment.
� USB 2.0 interface,no need to install the driver.
� Enough for checking even a small soldering / transistor in a PCB.
� The Endoscope total length is 103mm.
� The diameter of the Endoscope is 7.2mm.
� With the switch to control the ON/OFF of the LED (the LED can light up
gradually up to your control).
� You can bend it to see around a corner or to look directly at a feature in a bore.
� Driverless for Windows 2000, XP / Vista /win 7(see notes below).

Specifications:

� Working platforms: Windows, MAC, Linux


� Resolution: 640*480
� Light source: 6 highlighting LEDs (adjustable)
� Focusing: 2cm - infinity
� Camera OD: 7.2mm- FOV: 60°
� Display speed: 15-30fps
� Interface: USB 2.0
� Work current: 120mA(LED Turn off)
150mA(LED Turn on)

Page 1 of 13
View Play Cap User Guide
Guide:

Before useing ViewPlayCap,need to find out ViewPlayCap installer,Install it to the


computer successfully,then can be used.

1: Plug the endoscope USB2.0 into the computer's;

(a),Windows XP system screen bottom right hand corner will pop up


"found a new hardware USB video equipment",See attached picture;

(b),Windows 7 system can be heard prompt tone,for the first time connecting,the
computer need some time to find the driver,you just wait for install the driver
successfully,then will prompt"found the new hardware".

2: Double click the ViewPlayCap icon on the desktop, The will pop up
dialog box and image display.

3:The LED can be adjusted by the "LED adjuster" on the handler;

4: There are 2 ways for taking the pictures;

a) Press the Snap shot button on the handler;


b) Click the dialog box shoot icon.

Page 2 of 13
For saving the pictures,press CTRL+S,the pictures will stored in the pictures
favorites.

5: Video capture : Click‘file’option.Open the drop-down menu select"set capture


file",see below picture,

Page 3 of 13
Popup dialog box as follows: set file save file name and location, click on open to
preserve;

Popup dialog box as follows: set up the capture file size,click confirm;

Page 4 of 13
Set up the time limit: Click on the capture drop-down menu select set time limit,then
pop up dialog box(see below picture).set up the time limit press ok.

Click on " Capture" drop-down menu select"start capture"; see below capture (or
click )

Page 5 of 13
Pop up below dialog box, click confirm start the capture,To set a time limit will
automatically stop, and stored in a designated location.

AMCAP User Guide:

AMCAP is a green software,it is unnecessary to installed before use. The snap shot
button can not be used when use this program.

1: Plug the endoscope USB2.0 into the computer's;


(a),Windows XP system screen bottom right hand corner will pop up
"found a new hardware USB video equipment",See attached picture;

(b),Windows 7 system can be heard prompt tone,for the first time connecting,the
computer need some time to find the driver,you just wait for install the driver
successfully,then will prompt"found the new hardware".

Page 6 of 13
2: From the attached CD disk, find the AMCAP.EXT, copy it to "My
Computer"specified location,then double click and open it,will popup below dialog
box:

3:The LED can be adjusted by the LED adjuster on the handler;

4 : Video capture : Click‘file’option.Open the drop-down menu select"set capture


file",see below picture

Page 7 of 13
Popup dialog box as follows: set file save file name and location, click on open to
preserve;

Popup dialog box as follows: set up the capture file size,click confirm;

Page 8 of 13
Set up the time limit: Click on the capture drop-down menu select set time limit,then
popup dialog box(see below picture).set up the time limit press ok.

Pop up below dialog box: Use Time Limit select“√”,set capture time limit,then click
OK.

Page 9 of 13
Click‘capture’drop-down menu select‘Start Capture’;

Pop up below dialog box : Ready to Capture click OK start capture , it will
automatically stop, and stored in a designated location.

Page 10 of 13
If have not set up time limit,you can click ' Capture ' drop-down menu select‘Stop
Capture’。

On Windows XP system, you can see the picture from ' My computer ' ' USB
Video equipment '.

Fault detection:
It can not see the picture when endoscope connect with the computer.
1,Check the hardware connection status.
Connect the endoscope with the computer,right click ' My Computer ' ,
drop-down menu select ' manage ' ;

Windows 7 Windows XP

Page 11 of 13
Popup‘Computer manage’dialog box: Select‘device manager’ , then click on the
right‘Universal Serial Bus controllers’ See below picture.

In the drop-down menu,the need to have both and


2 items,then it will work ,see below picture;

If can not see both of them,please check whether the USB port is ok or not;

Page 12 of 13
2,Check the status of software

In View Play Cap,


Cap,Click ' Option ',open the drop-down menu,select ' preview
'.then select ' Device ' to see the drop-down menu, select ' USB video device, then
you can see the image;
In AMCAP, click ' Options' ,Open the drop-down menu,select ' preview '.then
select ' Device ' to see the drop-down menu, select ' USB video device, then you
can see the image.

Remark
Remark:
When more than one USB video equipment connected to the computer, '
Device ' will have multiple ' USB Device ',just select the one you need to use.
In software enabled suddenly cut off the electricity, or pull up the USB and
pull in again,then it will need to select the device drop-down menu ' USB Device
' to have image appear;
Choose improper USB extend wires,it may affect to slow or unable to
display the image.

Page 13 of 13