Вы находитесь на странице: 1из 2

AIR INDIA ENGINEERING SERVICES LTD.

ELECTRICAL O/H SHOP, DELHI


Annexure to work sheet for overhaul, check & test of A320 components

SMM APPROVAL NO. DATED:


CMM Reference: 21-53-11, Rev. 05 DATED: 01/04/2013
ANNEXURE SHEET NO. : DED/SMM/AV/EL/293, Initial Issue ,Rev.0

Nomenclature: TEMPERATURE SENSOR Current CMM Rev: Date:


Sr. No. : Part No. : 9105A0005-02
W.O. No. : IR/MIR NO.

SN. WORK DETAILS LIMITS AS PER ACTUAL SVC. INSP.


CMM/OHM ENGR.
2.A.(2) VISUAL CHECK :

Do a visual check of the


sensor for signs of damage.

(3) INSULATION TEST :

- Check pin A is connected to the


casing.

- Measure the insulation


resistance between pins B, C, D,
E, F, G interconnected
and pins H, K, J, A
interconnected. The measured Must be greater than 400
resistance must be greater than MΩ at 45 VDC
400 MΩfor an applied voltage of
45 VDC.

(4) BONDING RESISTANCE :

Supply 1 A between pin A and


any point of the equipment: the Must not
resistance must not be more than 20 mΩ.
be more than 20 mΩ.

(5) ELECTRICAL TEST : (Ref. Fig 2 of CMM 21-53-11 )

(a) Make sure that connector pins


C and D are connected.

(b) Make sure that connector pins


G and F are connected.

Page 1 of 2
(6) TEST SETUP :

(a) The sensor must be installed


in the temperature-controlled bath
or oven.

(b) Connect the resistor to an


ohmmeter with a test current of less than 0.1 mA
less than 0.1 mA.
(Connector pins B and C, and
connector pins E and F).

(7) RESISTOR TEST AT 0 °C (32 °F) :

Connect the PTC-resistor to an


ohmmeter with a test current of less than 0.1 mA
less than 0.1 mA.

Hold the PTC-resistor at a


temperature of 0 ± 3 °C (32 ± 5.4
°F) by use of the oven.

Measure Tref with a precision of ±


0.1 °C (± 0.18 °F).

Make sure that the resistance


value of the resistor is:

100 + (Tref x 0.39) ± 0.5 Ω (for 100 + (Tref x 0.39) ± 0.5


the two sensitive elements). Ω (for the two sensitive
elements).

(8) RESISTOR TEST AT 100 °C (212 °F) :

Increase the PTC-resistor


temperature to 100 ± 3 °C
(212 ± 5.4 °F) by use of the oven.

Measure Tref with a precision of


± 0.1 °C (± 0.18 °F).

Make sure that the resistance


value of the resistor is:

138.5 + ((Tref – 100) x 0.38) ± 0.5 138.5 + ((Tref – 100) x


Ω (for the two sensitive elements). 0.38) ± 0.5 Ω

Page 2 of 2

Вам также может понравиться