MARTIN-DECKER
SPECTRUM 1000—Numerical and bar graph liquid • Keyboard operations for setting alarms and zero-
crystal displays (LCD) are highly visible, even in ing bit weight are greatly simplified to make
direct sunlight. viewing or changing alarm limits easy.
• Flexible — Customer determines size, number of • Displays flash if alarm limits are exceeded.
displays,'sensors, and configuration or layout. To order: Contact your nearest Martin-Decker
• Console is designed to be "intrinsically safe" for sales office or Martin-Decker oilfield products
hazardous environments. distributor.
• Large 3/4" digits.
• Easy-to-follow instructions are clearly labeled
on the front panels. No special training
is necessary.
Ex defined: The generic term of all methods of protection The Martin-Decker Purged/Pressurized System
IX/iised in Europe, "Explosiongeschutzen," is used to With the Martin-Decker system, pressurization is maintained
cover all techniques of protection. by leakage compensation which is achieved by topping-off the
Electrical equipment installed on oil rigs, in oil refineries, system to maintain pressure, resulting in considerably less air
and similar places has long been recognized as a potential usage.
explosive hazard due to the risk of sparks or hot surfaces Beside explosion-proof versions of standard instrumentation,
igniting the highly flammable gasses or vapors which may be Martin-Decker offers a full line of explosion-proof support equip-
present. Early recognition of these potential hazards led to ment. Consult your Martin-Decker sales representative for spe-
many of the industrialized nations developing standards for cific requirements.
construction and testing of such apparatus. For additional information, request data sheet P-203.
• Designed to CENELEC Standards; EN 50 014, 016, 018, 019
and 020
• Certified for Europe by BASEEFA, PTB, NEMKO,
DEMKO, and INTEX
• Recognized by 17 countries in the European community
• Meets or exceeds many international inspection and
approval agency standards
Method 2. Elimination of the spark energy to a level well below the minimum needed to ignite
the flammable mixture.
Type of Protection Symbol Apparatus is.....
Increased Safety Ex'e' non-sparking plus additional measures taken to ensure safety.
Intrinsically Safe Ex'i' Capable of causing only very small sparks, which are less than required to
ignite explosive gasses.
For more than half a century, Martin-Decker has been in Decker's highly-trained service technicians, on call
the forefront of drilling control. Why? Because we know 24-hours a day.
drilling and what it takes to design instrumentation pack- Martin-Decker puts it all together to give you total con-
ages to match your particular rig requirements ... what- trol in your choice of three compact, variable configura-
ever they may be. Martin-Decker's reputation for quality tion, space-efficient packages.
is unexcelled in the oil industry. And it's backed by Martin-
DEVIATION OF MUD VOLUME
TRIP TANK VOLUME MUD PUMP SPM
TOTAL MUD VQLUME
WEIGHT ON BIT;
TOTAL HOOK LOAD
Straight-line,
space saving
design for use
where working
room is at a
minimum.
Compact L-shaped consoles have
a low profile so the driller can watch
console and rotary table simultaneously.
4434
The M/D-3200
THE FIRST RIG DATA PROCESSOR BUILT
WITH OILMEN IN MIND
If you can read and punch buttons, you can instantly have
information from up to 29 separate drilling parameters at
your fingertips. The M/D-3200 not only gives you raw digi-
tal data readouts, it gives you analog charts of all drilling
parameters to let you see conditions at a glance, to help
you spot trends, and make drilling safer and more
efficient.
SIMPLE TO USE
The M/D-3200 is completely self prompted. This means
that if you're not sure what to do next, all you have to do is
punch the "HELP" button. The M/D-3200 will ask you
what you want to accomplish, then tell you exactly how to
doit.
But just because it's simple to operate doesn't mean
it's short on capability. The M/D-3200 is one of the most
powerful and versatile rig data processing systems on the
market.
Basically, the M/D-3200 is made up of a processor, a
CRT video screen, Print-O-Graph dot matrix printer
(POG), an Analog Signal Conditioner and a Line Regula-
tor to protect the unit from fluctuations in the power sys- Certified Version for
tem. The CRT-monitor displays up to 29 separate para- Hazardous Use Available
meters in an easy-to-read dot matrix format on a 15"
screen.
The unit will accept line variations from 100-135V AC at
frequencies from 47 to 63 Hz.
THE MARTIN-DECKER DRILLING CHOKE High-torque hydraulic motor that drives a ball-
WHEN YOUR LIFE DEPENDS ON IT, YOU screw ram to open and close the choke, allowing
WANT A CHOKE TO KEEP YOU RIGHT the driller to move the plug out of the seat in fine
increments, thus preventing the plug from drifting.
ON THE NUMBERS Backup hydraulic system in the event of rig air
loss.
Rugged construction for most severe service.
Both API-certified and H2s compatible.
THE TOUGH OSE • Large 81/2" gauges make it easierto show immediate
pressure gain or loss for both drill pipe and casing.
Standard gauges show rig air supply and the
choke system's hydraulic pressure.
• Simple knock-off hammer nut design permits easy
inspection, faster service, and quicker replacement
of wear parts.
To order— Specify CHK11 OB for 10,000 psi or CHK115B
for 15,000 psi.
BALL HEAVY-DUTY
SIMPLE KNOCK-OFF
SCREW-DRIVEN HYDRAULIC MOTOR
HAMMER NUT DESIGN
ACTUATOR
HEAVY-DUTY
TUNGSTEN
CARBIDE
»» WEAR SLEEVES
TAPERED TUNGSTEN
CARBIDE SEALING PLUG
ANCHOR TYPE WEIGHT INDICATORS ANCHORS FOR E, EB, 125 & 150 WEIGHT
FOR THE LARGEST RIGS INDICATOR SYSTEMS
Type E/Series AWE with deadline loads of 75,000 Ib. for The National Type EB, for Type E or
6, 8,10 and 12 lines strung. Type EB Weight Indicators, with E80
Tension Load Sensor. Mounts on floor
Type EB/Series AWE with deadline loads of 100,000 Ib. or substructure. Type E System
for 8, 10,12 and 14 lines strung.* designed for 1-1/4", 1-3/8", and 1-1/2"
Type 125/Series AWE with deadline loads of 125,000 Ib. wireline sizes. Type EB Systems
designed for 1-1/2" and 1-5/8" wireline
for 8,10,12 and 14 lines strung.* sizes. Drum diameter 28". Net weight
Typo 150/Series AWE with deadline loads of 150,000 Ib. 1560 Ib.*"
for 10,12,14, and 16 lines strung.** The Hercules Model HA 131T, for Type
Type 200/Series AWE with deadline loads of 200,000 Ib. E or Type EB Weight Indicators, with
for 10,12,14, and 16 lines strung. E80 Tension Load Sensor. Mounts on
•Optional 16 lines on request "Optional 8 lines on request floor or substructure. Type E System
designed for 1-1/4", 1-3/8", and 1-1/2"
New Stainless Steel Driller's Panel Model wirelines. Type EB Systems designed
A10600A, with space for six gauges or HA 131T for 1-1/2" and 1-5/8" wirelines. Drum
meters plus weight indicator.
diameter 28". Net weight 1460 Ib.***
The Hercules Model HA 120T, for Type
E or EB Weight Indicators, with E551
Compression Load Sensor. Designed
Model for 1-1/4", 1-3/8", 1-1/2" and 1-5/8"
HA 120T wirelines. Drum diameter 28". Net
weight 1475 Ib.***
The Hercules Model HA 130T, for Type
125 Weight Indicator, with E551 Com-
Type E (typical) pression Load Sensor. Designed for
AWE Series 1-1/2", 1-5/8" and 1-3/4" wirelines.
Weight Indicator
Model Drum diameter 31". Net weight 2200
• Helps driller maintain consistent weight on bit to drill faster, IA 130T Ib.***
more efficiently and more economically. The Hercules Model HA 150T, for Type
• Available as separate -unit or, for greater convenience, 150 Weight Indicator with E551 Com-
mounted in driller's console with a choice of the following pression Load Sensor. Designed for
instruments: mud pump pressure gauge, mud pump stroke 1-5/8", 1-3/4", 1-7/8" and 2" wireline
meter (SPM), rotary table meter (RPM), electric torque meter, sizes. Drum diameter 36". Net weight
tong-torque gauge, automatic driller. 3050 Ib.***
• Cuts down on time consuming fishing jobs; detects stuck pipe, JiModel ***Wireline size must be specified when
tight holes. ~A150T ordering.
• Gauge consists of: outer dial for direct reading of weight on • Systems available in pound, kilogram and decaNewton
bit, inner dial for total hook load. models.
• Equipped with vernier bit weight indicator for 4:1 sensitivity, • System consists of weight indicator and wireline anchor with
greater accuracy. load sensor.
• Anchor secures deadline, with load cell mounted in anchor to To order: Specify size of rig, derrick capacity in pounds, size of
produce precise weight signals. These signals are drilling wireline, number of lines strung.
«
transmitted instantly to the gauge mounted in front of the
driller. ANCHORS FOR D
• Compatible with either National or Hercules deadline WEIGHT INDICATOR SYSTEMS
anchors. The National Type D, for Type D
Weight Indicator, with E80 Tension
ANCHOR TYPE WEIGHT INDICATORS Load Sensor. Mounts on floor or sub-
FOR LARGE RIGS structure. Designed for 1", 1-1/8" and
ypeD 1-1/4" wireline sizes. Drum diameter
24". Net weight 1080 Ib.***
Type D/Series AW with deadline
loads of 50,000 Ib. for 6, 8,10 and The Hercules Model HA 129T, for Type
12 lines strung. D Weight Indicator, with E80 Tension
Load Sensor. Mounts on floor or sub-
structure. Designed for 1", 1-1/8" and
Model 1-1/4" wirelines. Drum diameter 24".
HA129T Net weight 810 Ib..*
The Hercules Model HA 119T, for Type
D Weight Indicator, with E543 Compres-
sion Load Sensor. Mounts on floor or
substructure. Designed for 1", 1-1/8"
and 1-1/4" wireline sizes. Drum diame-
ter 24". Net weight 820 Ib.***
AW Series ***Wireline size must be specified when
Weight Indicator ordering.
4436
41
COOPER
INDUSTRIES
MARTIN-DECKER DRILLING RIG INSTRUMENTATION
SATELLITE AUTOMATIC DRILLER, • Provides automatic control of feed-off, yet retains de-
SERIES SA100 OR SA102 pendability of manual control.
• Eliminates the need to manually manipujate the brake,
while constantly watching the weight indicator by auto-
matically maintaining preset weight on the bit, which
can be increased or decreased in moments.
• Line feed governed entirely by bit weight for smoother,
Unit/zed satellite automatic faster drilling rate.
drilling controller unit... has a
straightforward, uncluttered • Drilling string is always under control of drawworks
design when installed in brake.
console.
• Available for all drawworks used in medium and deep
drilling programs.
To order—Specify make and model of drawworks.
For additional information, request data sheet P-117.
Measurement of return
mud flow in mud flow
lines.
Direct
SPM PUMP SPEED INDICATOR SERIES connection
• Measures pump speed, shows pump or hole trouble at to pinion-
shaft.
a glance—information not indicated on mud pressure
gauge.
• Powered by generator (supplied), which can operate
any number of meters. Needs no outside power or
batteries.
• Available in capacities from 0-100 to 0-500 spm. Direct connection
to piston rod oiler.
To order—Specify make and model of pump, capacity
desired, length of electric cable.
For additional information, request data sheet P-126. As an idler whee
to the V-belt
driving the oiler.
SPM Indicator
V-belt
pulley drive
from any shaft
turning in direct
Combination 150-300 RPM
proportion with
ELECTRIC TORQUE METERS Rotary Speed tachometer the rotary.
A combination of isolation amplifier and torque meter, the
system is for precise measurement of rotary-table torque,
giving you a guide to down-hole conditions. Helps avoid
twisting off the drill string, tells if a cone is missing from the
drill bit, and provides trend indication of formation
changes.
• Meter scales are available in a broad selection of
capacities and units such as ft. Ibs. and amperes,
metric, etc.
• Wide choice of options, including strip-chart recorders.
To order—Contact your nearest Martin-Decker repre-
sentative for Electric Torque Meter questionnaire.
HYDRO-MECH ROTARY TORQUE • Provides sensitive torque indication for any rig with a
ASSEMBLY, SERIES FA9 chain drive powered rotary table. Capacity is 500 and
1000 points (relative torque indication.)
• Helps determine hole conditions and torque patterns
giving the driller an indication of when to change bits.
• Warns driller of potential twist offs, locked cones, bit
trouble, gage loss or out-of-gage holes by showing
stress on drill pipe.
• Gauge dampener minimizes pointer oscillations
caused by movements in the drill string.
To order—Specify chain pitch and double or single chain
drive; specify if unit is to be attached to a recorder.
For additional information, request data sheet P-111.
TONG TORQUE ASSEMBLY, SERIES H6B • Provides an accurate check on critical make-up or
break out torque for all tool joints, drill collars, etc., used
with casing or tubing.
• Capacity up to 25,000 Ibs. and metric equivalent.
Tong Torque Gauge Portable Installation. The • Target pointer can be set to required torque to give
Torque assembly attached
has two pointers. to the tang itself can be driller an easily visible mark to work to.
used for spot checks on
power tongs. • Box or console mounted permanent installation pro-
vides tool joint make-up torque each time drill collars
are run in. No extra hook-ups are necessary.
• Can also be used with power tongs.
Permanent Installation.
The sensor attached
To order — Specify Ibs. line pull capacity required (in
to the back-up line English or Metric); for permanent or portable installation.
provides torque indi-
cation each time col- For additional information, request data sheet P-112.
lars are run.
POWER TONG TORQUE ASSEMBLY, Assures uniform and proper make-up of the string by indi-
SERIES H29A cating precise torque applied to each joint when running
pipe or casing with power tongs. Helps prevent loose
joints, galled threads and human or mechanical errors.
Compatible with Electric or Hydraulic Recorders.
• Capacities to 120,000 foot pounds or metric equivalent.
• Gauge features both indicator pointer and target
pointer which can be set manually.
• Load sensing piston is sturdy and allows accurate and
sensitive reading even in low torque range.
To order — Specify:
1. Tong make and model.
2. Tong capacity or desired torque value.
3. Tong handle length (Center line of casing or tubing to
sensor or long mounting).
11
4440
• Instrument offers precise readouts of mud deviations in • Standard power requirement: 120/240, 50/60 Hz.
each mud tank. As accurate as ± one barrel or ±1% of To order—Specify:
full scale, whichever is greater.
1. Number of tanks to be monitored.
• Quickly identifies sudden mud volume changes caused
by intrusion of formation gases into the well bore (a sign 2. Dimension of tanks.
of impending kicks) or mud loss into weak formations. 3. Capacity of tanks.
• Provides continuous surveillance of mud pit volume 4. Probe length required.
whether making hole or tripping. 5. Specify if visual or audible alarms are required.
• Visual and audible alarms can,be set to report mud in- 6. Specify readout in barrels or cubic meters.
crease or decrease beyond predetermined limits. 7. Specify optional two-channel recorder if required.
• Unique float/transducer design is highly sensitive: A 8. Distance from each tank to driller's position.
smoothing potentiometer minimizes the effects of off- 9. Dependent on working conditions on rig, specify ex-
shore rig motion or pit agitation. plosion proof or non-explosion proof model.
• Solid-state electronics for faster response. 10. Miscellaneous connectors, cable and J-boxes are
• Mud volume totalizer probe is explosion proof and UL available through Martin-Decker, or to be supplied by
approved (if required). client at rig-up.
• -50° to + 150°F operating temperature range. For additional information, request data sheet P-144.
• Models available to monitor up to six pits. Probe lengths
of 8', 10' and 12' (other lengths available on request).
• Instrument can be calibrated to any mud pit size up to
3000 bbl.
12
4441
Recording/monitoring....
• Can be supplied with optional MR series recorder for
remote readings. Can also be recorded on remote Dril-
logger or Circular Recorder.
To order—Provide the following information:
1. Diameter of return mud flow line.
2. Power requirements: 120/240 VAC, 50/60 Hz, 2.5 amp. Pump stroke sensor no. 1
3. Is a recorder required? What type?
For additional information, request data sheet P-150.
Certified Version for
Hazardous Use Available
UNIVERSAL TRIP TANK MONITORING SYSTEM, SERIES TTS Certified Version for
Hazardous Use Available
• Used to monitor mud volume in
replacing volume lost to drill pipe
coming put of the hole.
• Convenient dial display instantly tells
exact level of mud in trip tank. Elimi-
nates time-consuming calculations
and possibility of error.
• Alarms for high and low level condi-
tions immediately advise of impend-
ing problems.When trip tank level is
too low, system can drive fill pump
from main mud tank to refill.When
level is too high, system can take
mud from tank via drain output.
• Can be used with Martin-Decker Mud
Volume Totalizer and recorder to
supply a permanent record of each trip.
To order—Specify:
1. Dual or single trip tank system.
2. Dimensions and total capacity of each
trip tank.
3. Desired probe length.
4. Trip tank recorder, if required.
5. Specify readout in barrels or cubic
meters.
For additional information request data
sheet P-172.
Universal Trip-Tank Moni-
toring Console with Float
and Probe Sensor. 0 Dual trip tank systems.
HEET-RITE ELECTRONIC STRIP • Continuous strip chart paper can accommodate ap-
CHART RECORDER, SERIES MR proximately twenty-seven 24 hour periods.
• Purgeable models available for hazard reduction.
• Thermal writing element eliminates inking problems • Power requirements — choice of 115V AC, 50/60 Hz, 1
and pen replacement. amp or 230V AC, 50/60 Hz, 1/2 amp with step down
• Compact two-channel recorder ideal for rig floor moni- transformer.
toring of mud functions (other functions on request). To order—specify functions to be recorded, voltage and
• Displays a 5-hour record at all times. frequency (power requirements).
Certified Version for For additional information, request data sheet P-171.
Hazardous Use Available
To order —Specify:
Compression or tension system, indicator dial size, num-
ber of cells required, capacity.
Four cell compression totalizer for
vertical tank weighing.
Two cell compression totalizer for
horizontal tank weighing.
TANK WEIGHING SYSTEMS NEMA 4X enclosure for long lasting service and to help
DIGITAL INDICATOR SERIES DWC204A-11 withstand washdowns and hostile environments.
• Meets NBS Standards.
The DWC204A-11 Digital Indicator is the heart of an • Displays weight, thrust, force, pressure or torque.
advanced electronic tank weighing system'that may be • Microprocessor based system.
configured in a virtually infinite number of ways to suit • Accepts up to four load cell inputs.
various applications. • Zero and span controls.
The unit is housed in a water resistant, stainless steel • Large easy to read digits.
• Readings up to 16,000 x 1; 32,000 x 2; 80,000 x 5;
Single Cell Vertical Tanks 160,000 x 10; 320,000 x 20; 800,000 x 50; 999,900 x
Pivoted 2
Cell Vertical 100.
Bin or • Optional thumbwheel tare
Hopper For additional information, request data sheet P-199.
DWC204A-11 Digital
Indicator
Hydraulic Compression
Load Cell
DC 322/DC 310
Pressure
Transducer 15
4444
To order—Specify:
1. Functions desired.
2.1, 2, 3, 4, 5, 6 or 7-pen recorders.
3. Rig floor or dog house installation.
4. Whether drilling, hydrostatic testing or hydraulic casing
tong recorder required.
Rate of Penetration unit retrofits to
5. Consult your Martin-Decker sales representative for existing Martin-Decker
specific requirements. Record-O-Graphs easily in the field.
For additional information, request data sheet P-153.
Series
Crane Load &
Radius Indicator.
COMPRESSION LOAD CELLS FOR 6. Distance from winch or windlass to control console.
ANCHOR CHAIN AND/OR WIRE ROPE 7. Indicator size (6" or 81/2" dial).
TENSION MONITORING, SERIES CTW 8. Optional indicator and transducer console require-
ments.
• Instantly transmits signals of chain and/or wire rope 9. Recorder type.
tension loads to full 360° gauge indicator.
10. General arrangement information as to relative con-
• No external power source needed — all hydraulic! figuration and location of windlass or winch and all
• Mooring systems range from 200,000 to 1,000,000 Ibs. fairlead wildcats or sheaves.
• Accuracy: 0.5 of 1% of full scale. For additional information,
To order—Specify: request data sheets M-59
1. Rig name and type (semi-submersible or surface and M-73.
floater).
2. Number of anchors.
3. Windlass or winch make and model.
4. Chain and/or wire rope size.
5. Cell load, chain or wire rope and pivot ratios.
20
4449
i \ i i i i\——— r-ji-
Olfa-J
ii
t— WINCH
_1 /*^t=a/—
HOSE TO
WINCH
•^TIE-BAR
ASSEMBLY
CONTROL
STATION
DYNA-LINE
(3-SHEAVE ELEMENT) - SWIVEL
FAIRLEAD 7
-WINCH
t— WINCH
23
4452
0-5,000 Ibs.
To order—Specify indicator capacity, intended load on
cell. (50' hose is standard. 60', 75' and 100' hoses also
can be specified.)
24
4453
• Designed for small rigs or well service units. DEFLECTION TYPE WEIGHT INDICATOR
• Instrument has two pointers on one gauge; shows hook SERIES AA15 CLIPPER SEALTITE PRODUCTION
load with one pointer and vernier points with other. WEIGHT INDICATOR
• Portable console can be set up near well operator or
mounted on mast or derrick. Load Sensor
Diaphragm
• Equipped with 10 different dials calibrated for number Clipper Sea/We attaches
and size of line strung in pounds, kilograms or Portable production model easily to
mounted in metal box. wireline.
decaNewtons.
To order—Specify size of rig, derrick capacity in pounds,
size of drilling wireline, number of lines strung. Note: 25'
hose is standard; specify if more required. Also specify if
metric dials are needed.
For additional information, request data sheet P-33B.
• Designed for small drilling and production rigs. DEADEND TYPE WEIGHT INDICATORS
• Gauge has two pointers: one can be set as a target to SERIES WS8A MIDGET AND WS16 SUPER MIDGET
"pull to" or used as a reference of total load when set- WEIGHT INDICATORS
ting a packer, drilling, or pulling on stuck pipe.
• Weight sensor needs no deadline anchor.
• WS8A single line capacity is 25,000 Ibs. for small ser-
vice units or workover rigs. WS16 single line capacity is
30,000 Ibs. for small drilling and production rigs.
To order — Specify model number, size of rig, derrick
capacity in pounds, size of drilling wireline, number of
lines strung, English or metric dial.
For additional information, request data sheet P-125. Piston Cylinder Load Cell Sensor. Midget weight Indicator
Sensor. mounted in metal box.
• Makeup torque requirements are more critical on TUBING AND ROD TORQUE ASSEMBLY,
sucker rods and small tubing than on other SERIES H40A.
connections.
• Indicates actual torque output of long for each joint run
in the hole.
• Designed for makeup of all downhole tools.
• Fluid-filled 6" gauge mounts on long, load cell attaches
to tong handle, then to back-up line.
• Line pull model indicates to 6,000 Ibs.; joint torque mod-
els to 10,000-foot Ibs. or metric equivalents. Tubing and Rod
To order—Specify space available for load cell (length) Torque System.
Gauge mounts on
installation. Specify tong make and model. Models can tongs or tong hanger.
be ordered in pound, foot-pound, kilogram or meter-
kilogram calibration.
For additional information, request data sheet P-129.
• Compression load cell system consists of 6" or 81/2" TENSIOMETER CONVERSION UNITS,
dial indicator, hose and load cell for installation in
customer-supplied tensionmeter unit. For complete SERIES SW28,
systems, including tensionmeter force frame, see SW29, SW30,
Dynameter Tension Indicator, page 22. Used in well SW31 & SW36
survey and other downhole operations.
• Capacities from 4,000 to 20,000 Ibs., 1:1 or 10:1.
To order — Specify:
1. Tensionmeter make and model number.
2. Indicator size,
a. single pointer
b. dual pointer (10:1 ratio for greater sensitivity)
3. Capacity in either English or metric scale.
4. Intended application.
For additional information, request data sheets M-59 and
M-73.
25
4454
HYDRAULIC HYDRAULIC
SUM-MASTER CRANE
LOAD CELL SCALES
TOTALIZER
SYSTEMS
26
4455
MARTIN-DECKER
27
4456