Вы находитесь на странице: 1из 2

BRICK MASONARY STRENGTH CHECK

m
Basic wind speed vb := 39
s

k1 := 1

Class-A
k2 := 1
Terrain cat-2
k3 := 1

Design wind speed vz := 39 ⋅ k1 ⋅ k2 ⋅ k3


m
vz = 39
s

2
Design wind pressure pz := 0.6 ⋅ ( vz)

N
pz = 912.6
mm2

Force Coefficient Cf := 1.2 Table 24, IS875 Part3

1
Design wind force F := Cf ⋅ pz ⋅
1000
KN
F = 1.095
m
Effective Height h := 1.8 m

3 2 TABLE 13 IS 1905:1987
Design Moment M := ( 1 ) + .5 ⋅ .33 ⋅ 10 ⋅ 1

KN - m
M = 2.65
m
for 230mm thick masonary wall

2 3
1000 ⋅ 345 mm
Z :=
6

2
A := 1000 ⋅ 345 mm

A
Dead load of wall P := 19 ⋅ 5.15 ⋅
1000000

P = 33.758 KN

3 6
P ⋅ 10 M ⋅ 10
ft := -
A Z

N No Tension
ft = -0.036
2
mm

Allowable permissible stress in tension =0.05 N/mm^2 Cl5.4.2 IS1905:1987

HENCE SAFE