Вы находитесь на странице: 1из 2

COLUMN DESIGN/ANALYSIS SOFTWARE

(Based on the NSCP 2015 Code)


Designer: GRSILOT Checked by: GRS
Date: Jan-19 Date: Jan-19

Project Name: 2STOREY COMMERCIAL BLDG.


Column I.D. : Corner Ground Columns(C-2)

INPUT:
Column Shape: Reinforcing Bars Data:
Main bar diameter = 25 mm
Dimensions: Number of bars along face X = 4 bars
Width, bx = 400 mm Number of bars along face Y = 4 bars
Breadth, by = 600 mm Total number of bars = 12 bars
Concrete cover = 40 mm Steel Ratio, rg = 2.454%

Materials: Transverse Rebars:


Concrete, fc' = 20.7 MPa Tie diameter = 10 mm
Steel rebar, fy = 230 MPa Max. Demand/Capacity Ratio = 1.051 (Fail!!!)

Factored forces: y
Pu Mux Muy Muy
(kN) (kN-m (kN-m)
Case 1 827.118 53.485 -50.601 by x
Case 2 299.716 119.663 211.943
Case 3 328.523 -111.434 -138.67 bx
Mux
Case 4 519.355 -55.766 221.316
Case 5 365.535 -6.796 -212.451

OUTPUT:
Pu fPn D/C
Remarks
(kN) (kN) Ratio
Case 1 827.118 2076.8 0.398 (Ok!) 827.1 53.49 50.601
Case 2 299.716 285.0 1.051 (Fail!!!) 299.7 119.7 211.943
Case 3 328.523 454.3 0.723 (Ok!) 328.5 111.4 138.67
Case 4 519.355 555.9 0.934 (Ok!) 519.4 55.77 221.316
Case 5 365.535 404.1 0.905 (Ok!) 365.5 6.796 212.451
INTERACTION DIAGRAM(s):
COLUMN INTERACTION DIAGRAM (Mx , Mr)
6000

5000

4000
fPnx , fPnr

3000

2000

1000
1
4
5 32
0
0 100 200 300 400 500 600

fMnx , fMnr

Note: Disregard Interaction Diagram, My below for circular columns.

COLUMN INTERACTION DIAGRAM (My)


6000

5000

4000
fPny

3000

2000

1000
1
4
3 25
0
0 50 100 150 200 250 300 350 400

fMny