1.

Work done on 10/7/2018


case 55980 (2h) - Beam bottom bar and tabulated report not tally - Change the way
to obtain the data
case 52028 (1h) - Custom Parameter setting: Beam cover - Implement the custom
cover
case 55849 (1h) - Column Full Report - explain the value
case 55909 (2h) - Wall foundation Pilecap profile error - pilecap grouping issue
case 56024 (2h) - Wall slenderness check: Slab and beam relative stiffness
calculation - debug to get the value

2. Work to do on 11/7/2018
case 56027 (2h) - Raft design: Stay at 90% and will not continue
case 53220 (2h) - New load combination for punching slab checking
case 55983 (2h) - Beam critical region: Dimension
case 56001 (2h) - Beam critical region: Update Tabulated Report for Shear

1. Work done on 11/7/2018


case 56027 (1h) - Raft design: Stay at 90% and will not continue - send the case to
Wang
case 53220 (1h) - New load combination for punching slab checking - not able to
reproducible
case 55983 (2h) - Beam critical region: Dimension - fix the bug in detailing
case 56043 (4h) - BS VS EC Column Moments - pending

2. Work to do on 12/7/2018
case 56043 (4h) - BS VS EC Column Moments
case 56046 (2h) - Raft design result not updated
case 56032 (2h) - Internal Error in Design Slab
case 56001 - Beam critical region: Update Tabulated Report for Shear

1. Work done on 12/7/2018


case 56043 (3h) - BS VS EC Column Moments - explore the Madd calculation
case 56032 (1h) - Internal Error in Design Slab - fixed the exception
case 56046 (3h) - Raft design result not updated - fixed by save the file in plan
base
case 56034 (0.5h) - Esteem.Tests.BatchProcess unit test fails - rebaseline the
result
case 56058 (0.5h) - Esteem.Tests.Slab unit test fails - discovered that it is due
to slab moment value
case 55859 (0.5h) - Pile position - can be adjusted by selecting the wall pile
assignment

2. Work to do on 13/7/2018
case 56043 (2h) - BS VS EC Column Moments - check the minimum k factor
case 56001 (2h) - Beam critical region: Update Tabulated Report for Shear
case 55514 (2h) - DCH Detailing: Column passed but shown as failed
case 55511 (2h) - DCM Detailing: Column summary report error

1. Work done on 13/7/2018


case 56066 (1h): Esteem.Tests.BatchProcess unit test fails - fixed the breaking
code
case 56071 (1h): Esteem.Tests.CBSection unit test fails - fixed the breaking code
case 56069 (1h): Esteem.Tests.RCWallDetailing unit test fails - fixed the breaking
code
case 56043 (2h): BS VS EC Column Moments - change the k value from 1 to 0.1 for
fixed foundation
case 56001 (1.5h): Beam critical region: Update Tabulated Report for Shear (fixed
the bug)
case 55514 (1h): DCH Detailing: Column passed but shown as failed (not
reproducible)

2. Work to do on 16/7/2018
case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY)
Study on the moment capacity check (2h)
case 56086 (2h): 3D Raft/TransferSlab Contour Steel Area Band Strip Cut for Design

1. Work done on 16/7/2018


case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY) - fixed the
reporting part (send to Lau for other issue)
case 56043 (4h): BS VS EC Column Moments - beam stiffness multiplies 2 and column
stiffness only considers current column stiffness alone

2. Work to do on 17/7/2018
case 56043 (6h): BS VS EC Column Moments - Explore the beta calculation
case 56035 (2h): Esteem.Tests.BatchProcess unit test fails - revised the beam
torsion design for EC2
case 56114 (2h): Pile footing report: Check for pile load
case 56085 (2h): 2D Slab Contour Steel Area Band Strip Cut for Design : study the
implementation for the design

1. Work done on 17/7/2018


case 56043 (6h): BS VS EC Column Moments - Explore the beta calculation - done and
implement the revised rlative stiffness calculation to wall, check the limit for BS
and EC2. BS will 0.4 and EC2 will be 0.1, compare the wall beta value between
BS8110 and EC2
case 56035 (2h): Esteem.Tests.BatchProcess unit test fails - revised the beam
torsion design for EC2 - implemented

2. Work to do on 18/7/2018
case 56139 (2h): Esteem.Tests.CodeCommon unit test fails - due to relative stiffnes
set to 0.4
case 56114 (2h): Pile footing report: Check for pile load - output checking
case 56132 (2h): Beam shear and torsion failed: Section near column support -
result checking
case 56134 (2h): Unable to re-open Raft design result - file saving problem
case 55193 (2h): Detailing option for DCM and DCH (beam & column ONLY) - critical
region dimension issue

1. Work done on 18/7/2018


case 56132 (1h): Unable to re-open Raft design result - send to Wang for checking -
due to meshData3D deserialize error
case 56139 (1h): Esteem.Tests.CodeCommon unit test fails - remove the 0.4 checking
for BS 8110
case 56043 (2h): BS VS EC Column Moments - remove the 0.4 checking for BS 8110 and
multiplication of 2 only applicable to beam and slab, add in reference note and
check the k = 10 for slab
case 56114 (1.5h): Pile footing report: Check for pile load - round up the pile
length value
case 56147 (2h): Top element stiffness calculation for wall - BS 8100 - revised the
specification which the Min(kTW, kB) only applicable if one end of the wall is
restrained by the beam and the other end of the wall restrained by the wall.

2. Work to do on 19/7/2018
case 56043 (2h): BS VS EC Column Moments - follow up
case 55193 (4h): Detailing option for DCM and DCH (beam & column ONLY)
case 52028 (2h): Custom Parameter setting: Beam cover - updated the code

1. Work done on 19/7/2018


case 56043 (2h): BS VS EC Column Moments - close
case 52028 (1h): Custom Parameter setting: Beam cover - done
case 56162 (2h): unable design pilecap - governed by moment which induced by pile
spacing
case 56172 (2h): Raft not design - design the raft column even with edge beam
case 56171 (2h): Raft slab design exception - fixed the exception

2. Work to do on 20/7/2018
case 56172 (2h): Raft not design
case 56023 (4h): Parameter usage of TBeamEffect and BeamStiffInc
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 20/7/2018


case 56043 (2h): BS VS EC Column Moments - modify the layout in order to make the
column pass
case 56172 (3h): Raft not design - remove the checking of beam
case 55980 (3h): Beam bottom bar and tabulated report not tally
case 56176 (1h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button for band strip cut detailing

2. Work to do on 23/7/2018
case 55193 (3h): Detailing option for DCM and DCH (beam & column ONLY)
case 56147 (1h): Top element stiffness calculation for wall - BS 8110
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 23/7/2018


case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button and create data class to keep the As value
case 55193 (1h): Detailing option for DCM and DCH (beam & column ONLY) -
implemented the critical region length computation in the report
case 56147 (2h): Top element stiffness calculation for wall - BS 8110 -
implemented, multiplication of 2 only applied to slab and transverse beam
case 56172 (1.5h): Raft not design - provide a replacement method for
Esteem.Slab.Raft.RaftDesign.GetColumnCount(prj)
cas e56209 (1h): Raft failure message not tally with failed element list - fixed

2. Work to do on 24/7/2018
case 51101 (2h): Column Design Report for DCM Selected - Exception thrown when open
column full report
case 56023 (2h): Parameter usage of TBeamEffect and BeamStiffInc - check the Ec
usage
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create a button and create data class to keep the As value

1. Work done on 24/7/2018


case 56023 (2h): Parameter usage of TBeamEffect and BeamStiffInc - check the Ec
usage (use the original Ec)
case 56172 (2h): check the code to ensure RaftDesign class is not used in raft slab
design
case 51101 (2h): Column Design Report for DCM Selected - Exception thrown when open
column full report - fixed
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line
2. Work to do on 25/7/2018
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line (continue)
case 56230 (2h): Seismic EC8: capacity check (for checking purpose)

1. Work done on 25/7/2018


case 56172 (0.5h): Raft not design - fixed breaking code
case 56043 (0.5h): BS VS EC Column Moments - change the epsilon method to symbol, >
case 56176 (7h): Raft, slab, flat slab Detailing based on Steel area contour -
create data class for the object who intersect with the cut line (continue)

2. Work to do on 26/7/2018
case 56176 (7h): Raft, slab, flat slab Detailing based on Steel area contour
case 56230 (1h): Seismic EC8: capacity check (for checking purpose) - study the
specification

1. Work done on 26/7/2018


case 56172 (1.5h): raft not design: revised the IsColumnWithinOnSlabs() method
case 56238 (1.5h): fixed the raftslab design report
case 56242 (1.5h): Critical region length: Tapered beam - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour

2. Work to do on 27//2018
case 54573 (2h): Pad footing detailing comments from Ir Anthony
case 54618 (2h): Revise flexural shear check for pile cap design
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 27/7/2018


case 54573 (2h): Pad footing detailing comments from Ir Anthony - change the
lapping dimension style
case 54618 (2h): Revise flexural shear check for pile cap design - fixed
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 30//2018
case 53068 (2h): Raft Punching Shear Design for Floor based slab - result
verification
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 30/7/2018


case 53068 (2h): Raft Punching Shear Design for Floor based slab - result
verification
case 56277 (2h): Lot 61643 bungalow - fixed the combined footing bug case, does
not consider back fill soil load

2. Work to do on 31/7/2018
case 53068 (1h): Raft Punching Shear Design for Floor based slab - result
verification - done
case 56254 (2h): Critical region detailing not shown - fixed
case 56147 (1h): Top element stiffness calculation for wall - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 31/7/2018


case 53068 (1h): Raft Punching Shear Design for Floor based slab - result
verification - done
case 56254 (2h): Critical region detailing not shown - fixed
case 56147 (1h): Top element stiffness calculation for wall - fixed
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 1/8/2018
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 1/8/2018


case 56298 (1h): Program hangs when run slab design with P-delta = True - fixed the
index issue
case 56300 (2h): Click on Beam tabulated report will have an exception - fixed
case 56176 (5h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

2. Work to do on 2/8/2018
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour -
create the raftslab span class

1. Work done on 2/8/2018


case 56147 (1h): Top element stiffness calculation for wall - BS 8110
case 56176 (8h): Raft, slab, flat slab Detailing based on Steel area contour

2. Work to do on 3/8/2018
case 56175 (2h): Column drop profile overlap with beam
case 56176 (6h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 3/8/2018


case 56176 (5h): Raft, slab, flat slab Detailing based on Steel area contour - done
the column drop detailing
case 54573 (2h): Pad footing detailing comments from Ir Anthony - top bar diameter,
top bar spacing and top bar reinforcement strength

2. Work to do on 6/8/2018
case 56175 (4h): Column drop profile overlap with beam
case 56172 (2h): Raft not design
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 6/8/2018


case 56175 (4h): Column drop profile overlap with beam - synchronise the checking
with the raft slab design
case 56172 (2h): Raft not design - fixed the detailing issue
case 55193 & 56323 (2h): New Parameter: Seismic Detailing Style and Detailing
option for DCM and DCH (beam & column ONLY) - Point the parameter to
SeismicDetailingStyle

2. Work to do on 8/8/2018
case 56350 (6h): study on flat slab design
case 56230 (2h): Seismic EC8: capacity check (for checking purpose)

1. Work done on 8/8/2018


case 56374 (2h): Revise the torsion design in EC2 - implemented in tester version
and send to Jocelyn for testing
case 56369 (2h): Null reference exception in summary report - fixed - this is due
to one of the properties, transferslabnodeCMvalues yet to be deserialized.
case 56382 (2h): New parameter : Geometric Imperfection
case 56350 (2h): study on flat slab design

2. Work to do on 9/8/2018
case 56350 (8h): study on flat slab design

1. Work done on 9/8/2018


case 56391 (2h): Esteem.Tests.BatchProcess unit test fails - due to Timothy's code
changed
case 53068 (2h): Raft Punching Shear Design for Floor based slab - soil bearing
pressure is 0
case 56350 (3h): study on flat slab design
case 56374 (1h): Revise the torsion design in EC2 - create 2 new parameters :
Torsion Requirement Check based on BS 8110 and Torsion Stress Increment (%)

2. Work to do on 10/8/2018
case 56175 (1h): Column drop profile overlap with beam
case 55193 (3h): Detailing option for DCM and DCH (beam & column ONLY)
case 56382 (3h): New parameter : Geometric Imperfection
case 56230 (1h): Seismic EC8: capacity check (for checking purpose)

1. Work done on 10/8/2018


case 55193 (3h): Detailing option for DCM and DCH (beam & column ONLY) -
implemented for beam on wall
case 56382 (3h): New parameter : Geometric Imperfection - implemented in individual
element basis
case 56425 and case 56424 (2h): specification to define column drop thickness with
multiple slab input
case 56411 (1h): Esteem.Tests.BatchProcess unit test fails

2.Work to do on 13/8/2018
case 56411 (2h): Esteem.Tests.BatchProcess unit test fails
case 56423 (4h): Create data to store soil pressure in 2D & 3D raft
case 56176 (2h): Raft, slab, flat slab Detailing based on Steel area contour -
column drop top bar class

1. Work done on 13/8/2018


case 56423 (4h): Create data to store soil pressure in 2D & 3D raft - done but not
yet check in
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
column drop top bar class

2.Work to do on 14/8/2018
case 56423 (1h): Create data to store soil pressure in 2D & 3D raft
case 56374 (4h): Revise the torsion design in EC2
case 56176 (3h): Raft, slab, flat slab Detailing based on Steel area contour

1. Work done on 14/8/2018


case 56423 (1h): Create data to store soil pressure in 2D & 3D raft - implemented
case 56374 (4h): Revise the torsion design in EC2
case 56176 (3h): Raft, slab, flat slab Detailing based on Steel area contour -
create the bot span class

2.Work to do on 15/8/2018
case 56382 (2h): New parameter : Geometric Imperfection - report revision
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour
case 56483 (2h): Corbel design
1.Work done on 15/8/2018
case 56382 (2h): New parameter : Geometric Imperfection - report revision -
implemented
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the span class
case 56483 (2h): Corbel design

2.Work to do on 16/8/2018
case 56491 (4h): Raft : Empty Failed Report
case 56176 (4h): Raft, slab, flat slab Detailing based on Steel area contour -
create the top span class

1.Work done on 16/8/2018


case 56491 (4h): Raft : Empty Failed Report - done
case 56176 (3h): Raft, slab, flat slab Detailing based on Steel area contour -
create the top span class
case 56483 (1h): Corbel design

2.Work to do on 17/8/2018
case 53068 (2h) : Raft Punching Shear Design for Floor based slab
case 55193 (2h) : Detailing option for DCM and DCH (beam & column ONLY)
case 56323 (2h) : New Parameter: Seismic Detailing Style
case 56490 (2h) : Beam detailing DCM: COB

1. Work done on 17/8/2018


case 53068 (2h) : Raft Punching Shear Design for Floor based slab - test floor base
but turn on region base parameter = true
case 55193 (2h) : Detailing option for DCM and DCH (beam & column ONLY) - verify
with Lorita for the seismic detailing - done for Beam on Wall
case 56323 (2h) : New Parameter: Seismic Detailing Style - change the clause for
DCH
case 56490 (2h) : Beam detailing DCM: COB - revise the reporting for DCM:COB

2. Work to do on 21/8/2018
case 56176 (4h) : Raft, slab, flat slab Detailing based on Steel area contour
case 56517 (4h) : BS8110 Punching Shear

1. Work to done on 21/8/2018


case 56176 (7h) : Raft, slab, flat slab Detailing based on Steel area contour -
support class and top span class created
case 56517 (1h) : BS8110 Punching Shear - need to define the slab

2. Work to do on 27/8/2018
case 56580: Raft design should proceed if column is sitting on beam
case 55193: Detailing option for DCM and DCH (beam & column ONLY)
Please refer to columns (2,C) and (3,B). Both is to provided with 1.26mm^2/mm shear
and torsion link, but the Seismic Detailing for column (2,C) is 2T10-100, but (3,B)
is only T10-100.
case 56323: New Parameter: Seismic Detailing Style
Please update the clause for the column DCH seismic detailing report too

1. Work done on 27/8/2018


case 56580: Raft design should proceed if column is sitting on beam - verified
case 56323: New Parameter: Seismic Detailing Style - updated the column seismic
detailing report for DCH
case 55193: Detailing option for DCM and DCH (beam & column ONLY) - result
verification
case 56517: BS8110 Punching Shear
i) Detect the slab which overlaps with column
ii) Detect the column type
iii) Create column type in column properties which are corner column, edge column,
internal column and auto
iv) Generate the column drop polygon

2. Work to do on 28/8/2018
case 56176 (3h) : band strip cut detailing - do the bar labelling
case 56517 (3h) : BS8110 Punching Shear
Detect the column perimeter in polygon shape
case 56498 (2h) : 2D Precast, PC Beam Connection/Corbel Detailing

1. Work done on 28/8/2018


case 56517 (4h) : Punching Shear : create 2 methods for EC2 and BS 8110 column
control polygon
case 56176 (4h) : band strip cut detailing - do the column drop bar labelling

2. Work to do on 29/8/2018
case 56176 (4h) : band strip cut detailing - do the top bar and bottom labelling
case 56517 (4h) : Punching Shear engine

1. Work done on 29/8/2018


case 56176 (4h) : band strip cut detailing - do the top bar and bottom labelling
case 56605 (2h) : Flat slab punching shear report: Highlight failure in report
case 56517 (4h) : Punching Shear engine - two methods created : Ineffective polygon
for nearby opening and basic control polygon for internal, edge and corner

2. Work to do on 30/8/2018
case 55193 (2h) : Detailing option for DCM and DCH (beam & column ONLY)
case 56501 (3h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
case 56176 (3h) : band strip cut detailing - label the graph value and create
points for AsProv

1. Work done on 30/8/2018


case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
revise the method of control polygon
Use only control polygon EC2 for BS 8110 as well
create methods for beta value for EC2 and BS
Collect the 2D and 3D column moment (in progress)

2. Work to do on 3/9/2018
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
Collect the 2D and 3D column moment (in progress)

1. Work done on 3/9/2018


case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
Collect the 2D and 3D column moment (done)

2. Work to do on 4/9/2018
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
link the result to compute beta value

1. Work done on 4/9/2018


case 56665 (1h) : Pad Design: Column loading - fixed
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
link the result to compute beta value

2. Work to do on 5/9/2018
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
compute the slab are load and reporting presentation

1. Work done on 5/9/2018


case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
compute the slab are load and reporting presentation

2. Work to do on 6/9/2018
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
full reporting and summary reporting presentation

1. Work done on 6/9/2018


case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
full reporting and summary reporting presentation

2. Work to do on 7/9/2018
case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
full reporting and summary reporting presentation

1. Work done on 7/9/2018


case 56501 (7h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
full reporting and summary reporting presentation

2. Work to do on 8/9/2018
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
test on beta value for punching shear
case 56409 (4h) : Add Slab point load's "Dimension" & "Moment Factor"

1. Work done on 8/9/2018


case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
test on beta value for punching shear
case 56517 (4h) : BS 8110 Punching Shear

2. Work to do on 12/9/2018
case 56580 (2h) - Raft design should proceed if column is sitting on beam - fix the
detailing profile
case 56382 (2h) - Geometric imperfection - result verification
case 55193 (2h) - Detailing option for DCM and DCH (beam & column ONLY) - curve
beam
case 56409 (2h) - Add Slab point load's "Dimension" & "Moment Factor"

1. Work done on 12/9/2018


case 56580 (2h) - Raft design should proceed if column is sitting on beam - fixed
the detailing profile
case 56382 (2h) - Geometric imperfection - fixed the moment selection issue
case 55193 (2h) - Detailing option for DCM and DCH (beam & column ONLY) - curve
beam - fixed the curve beam detailing
case 50501 and case 56517 (2h) - considere opening and revise column perimeter for
ultimate load checking for EC2

2. Work to do on 13/9/2018
case 53068 (2h) - Raft Punching Shear Design for Floor based slab - check the soil
pressure value
case 53220 (2h) - New load combination for punching slab checking - check the
moment value for new EC load combination
case 56671 (2h) - Pad footing: Top Bar diameter
case 50501 and case 56517 (2h) - create the shear reinforment design methods
1. Work done on 13/9/2018
case 53068 (2h) - Raft Punching Shear Design for Floor based slab - check the soil
pressure value - find the soil pressure for every load case instead of using
minimum soil pressure
case 53220 (2h) - New load combination for punching slab checking - check the
moment value for new EC load combination - verify the moment value for new EC load
combination
case 56323 (2h) - When Ductility Class is DCM or DCH, it should ignore Seismic
Detailing setting. - implemented

2. Work to do on 14/9/2018
case 56671 (2h) - Pad footing: Top Bar diameter
case 56672 (2h) - Pile top bar: Diameter and spacing
case 56728 (2h) - Column DCM/DCH report: Highlight failure in Table of Contents
case 50501 and case 56517 (2h) - create the shear reinforment design methods

1. Work done on 14/9/2018


case 56671 (2h) - Pad footing: Top Bar diameter - implemented
case 56672 (2h) - Pile top bar: Diameter and spacing - implemented
case 56728 (2h) - Column DCM/DCH report: Highlight failure in Table of Contents -
implemented

2. Work to do on 18/9/2018
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018
case 53068 (2h) : Raft Punching Shear Design for Floor based slab
case 53220 (2h) : New load combination for punching slab checking

1. Work done on 18/9/2018


case 53068 (2h) : Raft Punching Shear Design for Floor based slab - fixed the soil
pressure value in the report
case 53220 (2h) : New load combination for punching slab checking - fixed an
execption occurs in new load combination
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear

2. Work to do on 20/9/2018
case 56767 (2h) : Pad/Pile : Side bars
case 55849 (2h) : Column Full Report - revise report
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear

1. Work done on 20/9/2018


case 56767 (2h) : Pad/Pile : Side bars - explained the outcome
case 55849 (2h) : Column Full Report - report has been revised
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear

2. Work to do on 21/9/2018
case 55193 (2h) : Detailing option for DCM and DCH (beam & column ONLY) - The
calculated critical region length is 750mm. But detailing shows otherwise
case 56323 (2h) : New Parameter: Seismic Detailing Style - When Ductility Class is
DCM or DCH, it should ignore Seismic Detailing setting.
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear

1. Work done on 21/9/2018


case 55193 (2h) : Detailing option for DCM and DCH (beam & column ONLY) - The
calculated critical region length is 750mm. But detailing shows otherwise. - fixed.
case 56323 (2h) : New Parameter: Seismic Detailing Style - When Ductility Class is
DCM or DCH, it should ignore Seismic Detailing setting - fixed
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear

2. Work to do on 24/9/2018
case 56501 (4h) : Punching Shear Check based on EC2 Seminar dated 7 Aug 2018 -
working on the shear reinforcement design for punching shear
case 56517 (4h) : BS8110 Punching Shear

1. Work done on 24/9/2018


case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 -
done for reporting. Testing on engine and reporting

2. Work to do on 25/9/2018
case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 :
Testing on engine and reporting
case 55849 (1h) : Column Full Report - release to customer version

1. Work done on 25/9/2018


case 55849 (1h) : Column Full Report - release to customer version
case 56501 and case 56517 (7h) : Punching Shear Check based on EC2 and BS 8110 :
Testing on engine and reporting

2. Work to do on 26/9/2018
case 56804 (4h) : DCH beam detailing: Transfer beam critical region
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking

1. Work done on 26/9/2018


case 56804 (2h) : DCH beam detailing: Transfer column critical region - fixed
case 53220 (2h) : New load combination for punching slab checking - fixed the
progress bar text
case 56828 (2h) : Error in slab design: Flat slab - fixed the exception case
case 56501 and case 56517 (2h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking

2. Work to do on 27/9/2018
case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking

1. Work done on 27/9/2018


case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking

2. Work to do on 28/9/2018
case 55543 (2h) : Spec revision on effective length calculation for Wall
case 55849 (2h) : Column Full Report
case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking

1. Work done on 28/9/2018


case 55543 (2h) : Spec revision on effective length calculation for Wall -
reviewed
case 55849 (2h) : Column Full Report - fixed the
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the column drop checking
1. Work done on 1/10/2018
case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking
2.Work to do on 2/10/2018
case 56804 (3h) : DCH beam detailing: Transfer beam critical region
case 56501 and case 56517 (5h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)

1. Work done on 2/10/2018


case 56804 (3h) : DCH beam detailing: Transfer beam critical region - fixed
case 56501 and case 56517 (5h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)
2.Work to do on 3/10/2018
case 56132 (2h) : Beam shear and torsion failed: Section near column support
case 55849 (2h) : Column Full Report
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)

1. Work done on 3/10/2018


case 56830 (2h) : efooting: Steel area required due to moment
case 52551 (2h) : Column punching shear RSA design - fixed
case 55849 (2h) : Column Full Report - fixed
case 56501 and case 56517 (2h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)

2. Work to do on 4/10/2018
case 56884 (1h) : A gap between 2 zones that provide the same link
case 56501 and case 56517 (7h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)

1. Work done on 4/10/2018


case 56501 and case 56517 (7h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)
2. Work to do on 5/10/2018
case 55849 (2h) : Column Full Report
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)

1. Work to do on 5/10/2018
case 55849 (2h) : Column Full Report
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS 8110 :
Code for the raft checking (continue)
2. Work to do on 8/10/2018
case 56931 (2h) : raft : column not designed
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS

1. Work done on 9/10/2018


case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS : work on
detailing

2. Work to do on 10/10/2018
case 56953 (2h) : TOC of Beam opening full report
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 10/10/2018


case 56953 (2h) : TOC of Beam opening full report
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS : work on
detailing

2. Work to do on 11/10/2018
case 56402 (2h) : Design> Pad: Show Top Bar parameter move to Detailing parameter
case 56931 (2h) : Raft : Column not designed
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 11/10/2018


case 56402 (2h) : Design> Pad: Show Top Bar parameter move to Detailing parameter -
fixed
case 56931 (2h) : Raft : Column not designed - fixed by using CGAL union method
case 56974 (1h) : Static Analysis: User defined response spectrum detail
calculation TOC - fixed
case 56975 (1h) : Static ELFA: No calculation for Sdx
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

2. Work to do on 12/10/2018
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 15/10/2018


case 56992 (2h) : Error in design slab floor 1b - fixed
case 56501 and case 56517 (6h) : Punching Shear Check based on EC2 and BS : work on
detailing

2. Work to do on 16/10/2018
case 54049 (4h) : DCM: wall boundary condition check
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 18/10/2018


case 57031 (4h) : Envelope Bending Moment Diagram for Seismic Design of r/c Walls
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 17/10/2018


case 57049 (2h) : Esteem.Tests.Slab unit test fails : to diagnose the problem
case 57031 (2h) : Envelope Bending Moment Diagram for Seismic Design of r/c Walls
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing

2. Work to do on 18/10/2018
case 57062 (2h): Seismic: Normalised axial force check
case 57031 (4h) : Envelope Bending Moment Diagram for Seismic Design of r/c Walls
case 56501 and case 56517 (2h) : Punching Shear Check based on EC2 and BS : work on
detailing

1. Work done on 19/10/2018


case 57031 (7h) : Envelope Bending Moment Diagram for Seismic Design of r/c Walls
2. Work to do on 22/10/2018
case 57031 (4h) : Envelope Bending Moment Diagram for Seismic Design of r/c Walls
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS : work on
detailing : include the beam reaction

1. Work done on 23/10/2018


case 52551 (2h) : Column punching shear RSA design
case 56501 and case 56517 (2h) : Punching Shear Check based on EC2 and BS

2. Work to do on 24/10/2018
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS
case 57114 (4h) : Post-Analysis Interactive Design

1. Work done on 26/10/2018


case 56402 (4h) : Design> Pad: Show Top Bar parameter move to Detailing parameter
case 56409 (4h) : Add Slab point load's "Dimension" & "Moment Factor"

2. Work to do on 29/10/2018
case 57146 (0.5h): Esteem.Tests.BatchProcess unit test fails
case 57163 (0.5h): Esteem.Tests.RCWallDetailing unit test fails
case 57163 (0.5h): Esteem.Tests.Slab unit test fails
case 56402 (2h): Design> Pad: Show Top Bar parameter move to Detailing parameter
case 56403 (2h): Design> Pile: Show Top Bar parameter move to Detailing parameter
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS

1. Work done on 29/10/2018


case 57146 (0.5h): Esteem.Tests.BatchProcess unit test fails
case 57163 (0.5h): Esteem.Tests.RCWallDetailing unit test fails
case 57163 (0.5h): Esteem.Tests.Slab unit test fails
case 56402 (2h): Design> Pad: Show Top Bar parameter move to Detailing parameter -
implemented
case 56403 (2h): Design> Pile: Show Top Bar parameter move to Detailing parameter -
implemented
case 56501 and case 56517 (3h) : Punching Shear Check based on EC2 and BS - testing
on edge column

2. Work to do on 30/10/2018
case 56501 and case 56517 (4h) : Punching Shear Check based on EC2 and BS
case 57114 (4h): Post-Analysis Interactive Design : Colum drop

1. Work done on 30/10/2018


case 56501 and case 56517 (8h) : Punching Shear Check based on EC2 and BS - testing
on edge column (done)

2. Work to do on 31/10/2018
case 57114 (8h): Post-Analysis Interactive Design : foundation design

Work done on 12/12/18:


case 57528 (2h) : Pile cap dimension
case 57529 (2h) : Pile cap rotation

Work to do on 13/12/18:
case 57374 (2h): Deflection check : Additional Message
case 57225 (2h): Flat Slab & Transfer Slab: Failed Element list for punching shear
checking
case 56403 (2h):
Design> Pile: Show Top Bar parameter move to Detailing parameter
case 48027 (2h): Esteem 9 to Etabs
case 48564: column moment capacity design DCM and DCH - 1.3
case 51119: beam shear capacity design DCM - 1.0 and DCH - 1.2

Вам также может понравиться