1.3 FRONT PANEL Usage of Front Panel and Buttons
The device has a back-lit 2.5 LCD which contains two lines as numeric and alpha-numeric, warning 1. Up button
2. Set button, for entry to menu and value entry
symbols and notification signs. There are three buttons for programming the device. Explanations
3. Down button
about the display and buttons are listed on the right side.
4. Indicates that the password protection is active.
5. Indicates the existence of communication. It blinks during communication. (DCV-10S/10CS/11S/11CS)
6. The line where measured parameters are displayed.
7. Indicates the direction of the measured voltage.
8. Indicates the notification messages or the menu where the user is.
8 9. Units belonging to measurements and analog output parameters.
1 10. Indicates that the contact or contacts are in a high fault state. When entering a value in High Alarm type,
4 DC VOLTMETER it lights up continuously. When entering a low value for Range Alarm type, it lights up continuously and
5
2 when entering a high value for Range Alarm type, it blinks.(DCV-10C/10CS/11C/11CS)
6
Rx/Tx % PASSWORD 11. Indicates that the contact or contacts are in a low fault state. When entering a value in Low Alarm type,
88888
it lights up continuously. When entering a high value for Range Alarm type, it lights up continuously and
3
10 when entering a low value for Range Alarm type, it blinks.(DCV-10C/10CS/11C/11CS)
12. 1st Contact Output (DCV-10C/10CS/11C/11CS)
7
11 13. 2nd Contact Output (DCV-10C/10CS/11C/11CS)
C1 C2 14.15. Indicates that the contacts are closed.(DCV -10C/10CS/11C/11CS)
12
14 DCV-10S
V
13 15 9
5 6
Special Functions for Buttons 1.4 HARDWARE FEATURES
- Voltage measurement connector (2-pin, V+, V-)
UP button: It helps you display maximum tension value during measurement. - 0/2-10V, 0-4/20 mA Analog Output connector (3-pin, V, GND, I)(DCV-10A/11A)
In programming mode, it is used to switch device parameters. If lock function is active,
- RS-485 connector (4-Pin)(DCV-10S/10CS/11S/11CS)
it enables alarm output contacts when tension value exceeds the configured threshold.
When the tension is between the set limits, alarm output contacts are not turned off - 2 Relay connectors ( 4-pin)(DCV-10C/10CS/11C/11CS)
(locked-hold). When pressed together with DOWN button (UP + DOWN), - Supply input (2-pin) (85-265V AC/DC (DCV-10/10A/10C/10S/10CS),
output switches are turned off. 10-56V DC (DCV-11/11A/11C/11S/11CS))
SET button: 3 seconds. When you hold down this button, MAIN MENU mode is activated.
2- USAGE OF DEVICE:
It is used to switch from MAIN MENU to SUB MENUS and to save parameter changes.
2.1 MENU USAGE AND SETTINGS:
After the device is installed according to the connection diagram in the user manual, energise the
device.(Refer to: Connection diagram)
DOWN button: It helps you display minimum tension value during measurement. In order for the measurements and applications to be accurate, necessary adjustments must be made
In programming mode, it is used to switch device parameters. If lock function is by using menus.
active, it enables alarm output contacts when tension value exceeds the configured 2.2 MAIN MENUS:
threshold. When the tension is between the set limits, alarm output contacts are There are 11 main menus on the device for measurement and usage settings. The user can access
not turned off (locked-hold). When pressed together with UP button (UP + DOWN), MAIN MENUs by pressing the SET button for 3 seconds on measurement screen. By pressing the SET
output switches are turned off. button on any MAIN MENU, SUB MENUs of the related MAIN MENU is entered.
7 8
MAIN MENU FLOW:
2.2.1 PERIOD Period Setting Menu
After the device samples for a specified time, it displays the measurement result by calculating the
mean value of those samples. You can set the sampling time in this menu. Period value can be entered
between 1-600 seconds.
Press for 3 s.
DCV-10C/10CS/
11C/11CS.
Only valid for
DCV-10A/11A.
DCV-10S/10CS/
11S/11CS.
001 050
2.2.2 ALARMS Alarms Menu
PERIOD ALARMS ANLG OUT RS 485 RESET DCV -10C/10CS/11C/11CS devices have two normally open (NO) contact outputs. Operating modes
001 NO of the alarms are set in this menu. Each alarm can be set to one of six operating modes. These modes
are high alarm, low alarm, high-low (range) alarm and their 3 inverted counterpart modes. This menu
has 2 sub-menus.
ALARM1, ALARM2
ESCAPE SECURITY FCTRY SET LANGUAGE DISPLYSET
tENG SET
SET SET
ALARMS ALARM 1 ALARM 2 BACK MENU
9 10
ALARM1Alarm 1 Setting Menu
Operating mode of the relay on the device and the parameter according to that operating mode is set CONTCT POS Contact Position Setting Menu
in this menu. All settings belonging to 1. Alarm relay is done in this menu. Settings belonging to 2. The starting position of the alarm relay output is set in this menu. If this option is selected as OFF,
Alarm relay can be done in ALARM2 menu. This menu has 1 sub-menu. contact output starts as open when there isnt a fault condition. If this option is selected as ON, contact
output will be closed when there isnt a fault condition. It is set OFF as factory default.
SET
SET
CONTCT POS
ALARM 1 ALRM STAT BACK MENU
CONTCT POS SET SET CONTCT POS
OFF ON
"ALRM STAT" Alarm Status Setting Menu
TRIP
Alarm function of the relay is activated in this menu. If "OFF" option is selected in this menu, alarm
parameters of the corresponding relay cant be accessed. If the alarm function will be used, "ALRM If the measured voltage value becomes more than 1.5 times of set maximum voltage value when the
STAT" option must be set as "ON" in this menu. When alarm status is set as ON, the 2 sub-menus TRIP function is selected as YES, related alarm contact will open without a delay. In this case, up
of this menu become accessible. These menus are "CONTCT POS", "ALRM TYPE", "TRIP" and segment on the LCD and the dot in the C1 segment turn on. If the measured voltage value becomes less
"LATCH" menus. than 0.5 times of set minimum voltage value, related alarm contact will open without a delay. In this case,
down segment on the LCD and the dot in the C1 segment turn on.
ALRM STAT
SET
TRIP
SET
ALRM STAT
CONTCT POS TRIP LATCH TRIP
OFF SET ALRM TYPE BACK MENU SET TRIP SET SET
11 12
LATCH When the alarm type is selected as High Alarm, first contact output opens after an on-delay time (H
When the latch function is selected as YES, a predefined alarm contact will open in case an alarm ON DEL) if the measured voltage becomes more than the entered maximum voltage value (HGH
state arises. When the alarm state is resolved, the contact remains open (It latches). To close the VALUE) and immediate opening option is inactive. In this case, up segment on the LCD and the dot
alarm outputs after the alarm state is resolved, SET button is pressed. When the latch function is in the C1 segment turn on. When the measured voltage drops below the set maximum value (HGH
selected as NO, the opened alarm output will close after the predefined delay time. VALUE) as much as the high hysteresis value (HIGH HYS) and immediate opening option is inactive,
LATCH first output contact closes after an off-delay time (H OFF DEL). In this case, up segment on the LCD
and the dot in the C1 segment turn off.
LATCH SET SET LATCH
NO YES When the alarm type is selected as Low Alarm, first contact output opens after an on-delay time (L
ON DEL) if the measured voltage becomes less than the entered minimum voltage value (LOW
ALRM TYPE Alarm Type Setting Menu VALUE) and immediate opening option is inactive. In this case, down segment on the LCD and the
Operating mode of the alarm is set in this menu. Alarm has 3 operating modes which are High, Low and dot in the C1 segment turn on. When the measured voltage rises above the set minimum value (LOW
Range (High-Low). VALUE) as much as the low hysteresis value (LOW HYS) and immediate opening option is inactive,
ALRM TYPE first output contact closes after an off-delay time (L OFF DEL). In this case, down segment on the
LCD and the dot in the C1 segment turn off.
When the alarm type is selected as High-Low Alarm (Range), LOW VALUE operates as low alarm
SET SET
ALRM TYPE ALRM TYPE and HGH VALUE operates as high alarm. While this alarm type is selected, minimum voltage value
HIGH LO (LOW VALUE) cant be entered higher than maximum voltage value (HGH VALUE).
13 14
HIGH ALARM H OFF DEL
HGH VALUE It is the delay time for the high voltage alarm to deactivate. The value is entered as seconds. It can be
The highest value that you want the measured current to reach is entered in this menu. A value between entered between 000.0 and 999.9 seconds.
-200....200 can be entered.
H OFF DEL H OFF DEL
HGH VALUE HGH VALUE H OFF DEL SET SET SET
H OFF DEL
HGH VALUE SET SET SET
HGH VALUE 050.0 50.0 005. 005.0
100aa
A
100 00 005 A
HIGH HYS LOW ALARM
LOW VALUE
In this menu display, you should set the percentage value of hysteresis current required to return the The lowest value that you want the measured current to reach is entered in this menu. A value between
device to normal current (in case of high current warning). This value shall be between 0 and 20.
-200.0....200.0 can be entered.
HIGH HYS HIGH HYS
HIGH HYS SET SET SET
HIGH HYS LOW VALUE LOW VALUE
10 0 2 20 LOW VALUE SET SET SET
LOW VALUE
100 A
00 05 050 A
H ON DEL LOW HYS
It is the delay time for the high voltage alarm to activate. The value is entered as seconds. It can be In this menu display, you should set the percentage value of hysteresis current required to return
entered between 000.0 and 999.9 seconds. the device to normal current (in case of low current warning). This value shall be between 0 and 20.
H ON DEL H ON DEL LOW HYS LOW HYS
H ON DEL SET SET SET
H ON DEL LOW HYS SET SET SET
LOW HYS
050.0 50.0 005. 005.0 10 0 2 20
15 16
L ON DEL 2.2.3 ANLG OUT Analog Output Setting Menu
It is the delay time for the low voltage alarm to activate. The value is entered as seconds. It can be
ANLG OUT
entered between 000.0 and 999.9 seconds.
The device can give a voltage or current output with respect to the measured voltage according to your
selection. Analog output value can be selected as 0-10V, 2-10V, 0-20mA or 4-20mA. The user can set the
L ON DEL L ON DEL
L ON DEL SET SET SET
L ON DEL analog output type, turn off the analog output, learn the active analog output type or set the minimum and
050.0 50.0 005. 005.0 maximum values which the device will take into consideration when generating an analog output.
L OFF DEL
It is the delay time for the low voltage alarm to deactivate. The value is entered as seconds. It can be SET
entered between 000.0 and 999.9 seconds. SET
ANLG OUT ANLG OUT
050.0 50.0 005. 005.0 ANLG OUT ANLG OUT ANLG OUT ANLG OUT
mA mA V V
SET SET SET SET
17 18
HIGHEST 2.2.4 RS-485 Serial Communication Setting Menu
The voltage value corresponding to the maximum value of the selected analog output type is set in All measured parameters can be transferred via RS485 line with MODBUS protocol and menus can be set
this menu. This value can be entered between -200 and 200V. remotely.
Example: When the analog output type is selected as 0 - 20 mA and HIGHEST value is set as Note: Communication feature is available only on DCV-10S/10CS/11S/11CS models. In order for the
100V, current value on the analog output will be 20 mA when the measured voltage becomes 100V. communication to be accomplished; Address, Baudrate and Parity values must be entered to the device
correctly. RS 485 menu has 3 sub-menus. ADDRESS , BAUDRATE , PARITY.
SET
HIGHEST SET
HIGHEST SET
HIGHEST HIGHEST
200 V
00 10 100 V RS-485 SET
ADDRESS BAUDRATE PARITY
001 9600 NONE
LOWEST
The voltage value corresponding to the minimum value of the selected analog output type is set in
BACK MENU
this menu. This value can be entered between -200 and 200V. SET
Example: When the analog output type is selected as 0 - 20 mA and LOWEST value is set as
10V, current value on the analog output will be 0 mA when the measured voltage becomes 10V.
ADDRESS Address Setting
Address information can be entered between 1 and 247.
LOWEST LOWEST
LOWEST SET SET SET
LOWEST
000 V
00 03 030 V ADDRESS ADDRESS
SET SET SET
ADDRESS ADDRESS
001 01 03 030
19 20
BAUDRATE Baudrate Settings MODBUS RTU PROTOCOL
Enter one of the 2400 bps, 4800 bps, 9600 bps, 19200 bps, 38400 bps values as stated in the Standart MODBUS RTU message is shown below.
communication software.
ADDRESS FUNCTION DATA
BAUDRATE Selected T 8 BIT 8 BIT N x 8 BIT CRCH CRCL T
parameter
is
displayed The T times corresponds to a time in which data must not be exchanged on the communication bus
SET SET
BAUDRATE BAUDRATE to allow the connected devices to recognize the end of one message and the beginning of another.
9600 9600 This time must be at least 3.5 characters at the selected baud rate. Adress range (1-247) is address
of the connected device. The data field contains data sent to the slave by master or data sent to
master by slave. CRC is a error check method by using MODBUS RTU protocol and consists of 2
bytes.
PARITY Parity Setting Modbus Functions:
Parity can be entered as none, odd or even.
03H READ HOLD REGISTERS 10H PRESET MULTIPLE REGISTERS
PaRITY Selected
parameter
is 06H PRESET SINGLE REGISTER 2BH READ DEVICE INFO
displayed
SET SET
PaRITY PaRITY
NONE EVEN
21 22
Read Hold (03H) function is used for reading the measured parameter (intantenaous measurement Read device info (2BH) function is used to learn the manufacturer name, the device code, hardware version
value, minimum and maximum measurement values) and other setting values of the device. If any and software version. The query packet to read the device info is as following:
01 2B 0E 01 00 70 77
register other than this area has been tried to read, the device will send an error message.
For example; below message can be sent to read the measured voltage value:
2.2.5 RESET Reset Menu
01 03 00 00 00 01 84 0A Minimum and maximum values among measured voltage values are stored on the device. Reset menu is
Device Function MSB LSB Register Register CRC LSB used in order to delete these values. There are 2 sub-menus under Reset menu: RESET MIN, RESET
Address Address Address number number MSB MAX. To see the measured minimum and maximum values, refer to the Special Functions for Buttons
MSB LSB
section of this user manual.
Preset Single Register (06H) function is used for change device settings and resetting the measured NOTE: Stored values are not affected from power outages. Measured minimum and maximum values are
minimum/maximum values. deleted after you select YES option under the value that you want to reset and approve the changes when
For example; below message can be sent to set the period value to 100:
you exit or a zero (0) value is written into the addresses that these values are stored.
01 06 80 27 00 64 11 EA
Device Function MSB LSB Data Data CRC CRC SET
Address Address Address MSB LSB MSB LSB
SET
Preset Multiple register (10H) function is used for changing more than one register value. RESET RESET MIN RESET MAX BACK MENU
For example; below message can be sent to set the contrast value to 10 and the period value to 100:
01 10 80 26 00 02 04 00 0A 00 64 31 B2
Device Function MSB LSB Register Register Byte Data Data Data Data CRC CRC
Address Addr. Addr. number number count MSB LSB MSB LSB MSB LSB
MSB LSB
23 24
RESET MIN Minimum Value Reset Menu 2.2.6 DISPLYSET Display Setting Menu
It is the menu where stored minimum voltage value is deleted. Settings about the device display are done in this menu. Display setting menu has 2 sub-menus:
BACKLIGHT, CONTRAST.
SET SET
RESET MIN RESET MIN SET
DISPLYSET BACKLIGHT CONTRAST BACK MENU
YES 15
25 26
CONTRAST Contrast Setting Menu 2.2.8 FCTRY SET Factory Setting Menu
Contrast of the device display is set in this menu. It can be set to a value between 00 and 15. Factory settings are loaded in this menu. A 4 digit password is asked when entering this menu. If password
protection is active, the password isnt asked again when entering this menu because it was entered during
entering the main menu. If YES option is selected in this menu and SAVE confirmation is approved at the
exit of main menu, factory settings are loaded (Refer to: Factory Default Values).
SET
CONTRAST SET
CONTRAST SET
CONTRAST CONTRAST
15 5 1 10 If password is inactive. If password is wrong.
000 ERROR
2.2.7 LANGUAGE Language Setting Menu
Language of the device is set in this menu. There are 2 language options as Tr Turkish and Eng If password is active. If password is correct.
English.
FCTRY SET
LANGUAGE SET SETTINGS
SET SET
DONE
LANGUAGE DIL
ENG TR SET
NOTE: When factory settings are loaded, language setting stays unchanged. The language will be the same
as the on selected last.
27 28
2.2.9 SECURITY Security Setting Menu CHNG PASS Change Password Menu
Device password settings are done in this menu. There are 2 sub-menus under SECURITY menu. Password is changed in this menu.
PASS ACTV, PASS CHNG. Password activation and changing operations are done under these
menus. Factory default password is 0000.
SET
OLD PASS SET
OLD PASS SET
NEW PASS SET
SET CHNG PASS
000 000 000
SET
SECURITY PASS ACTV PASS CHNG BACK MENU SET
REENTER SET
REENTER SET
NEW PASS
PAS CHNGD
NO 111 000 111
SET
ENTR PASS SET
ENTR PASS SET
PASS ACTV
PSIVE 000 000 SET
SET SET
BILGI SOFT VER HARD VER SERI NO BACK MENU
Selected PASS ACTV
parameter 2.00.00 2.00.00 00001
is
displayed.
ACTVE
29 30
2.2.10 ESCAPE Exiting Main Menu 3.2. CONNECTION DIAGRAM
It is used to exit the main menu. If any changes has been made in the menus, a confirmation is asked to
save those changes. If there are no changes, measurement results are displayed without a confirmation.
SAVE Changes MEASUREMENT RELAY 1 RELAY 2 V GND A TR B A GND
SET
are saved. SCREEN
1 2 3 4 * 5 6 7 ** 8 9 10 11 ***
SET
ESCAPE
SET 024.00 RS-485
85-265 V AC/DC *****
Changes
are 12 13 14 15
discarded.
+ Vin - **** + Un - ****
3. INSTALLATION
3.1. DIMENSIONS AND INSTALLATION
Dimensions Panel Cutout Dimensions Control Panel Area Dimensions
Wall
54mm 200V DC 1A
48mm
44mm
43mm
31 32
3.3. PC CONNECTION 4. FACTORY DEFAULT VALUES:
Alarms:(DCV-10C/10CS/11C/11CS)
MAX. 31 DEVICES CAN BE CONNECTED ON THE SAME LINE
1.Alarm:
MAX. 1200 mt. RS-485 / RS-232 Alarm Status : Passive
Converter Latch : Off
B Trip : Off
A PC Contact Position (Output Inverse) : Off
GND
Alarm Type : High Alarm
High Alarm Value : 100V
Low Alarm Value : 10V
...
TR B A GND TR B A GND TR B A GND
High Alarm Hysteresis : 10
Low Alarm Hysteresis : 5
DCV-10S/10CS -31. DCV-10S/10CS -2. DCV-10S/10CS -1. High Alarm On Delay (d_on_time) : 20s
DCV-11S/11CS -31. DCV-11S/11CS -2. DCV-11S/11CS -1.
High Alarm Off Delay (d_off_time) : 10s
247 DEVICES CAN BE CONNECTED ON THE SAME LINE BY USING A REPEATER Low Alarm On Delay (d_on_time) : 20s
Low Alarm Off Delay (d_off_time) : 10s
2.Alarm:
MAX. 1200 mt. MAX. 1200 mt. RS-485 / RS-232
Converter Alarm Status : Passive
B Latch : Off
A PC
GND
Trip : Off
Contact Position (Output Inverse) : Off
Alarm Type : High Alarm
... ...
GND
TR
B
A
33 34
Low Alarm Hysteresis : 5 5. TECHNICAL FEATURES:
High Alarm On Delay (d_on_time) : 20s Operating Voltage (Un) :8 5 - 2 6 5 V A C / D C ( D C V - 1 0 / 1 0 A / 1 0 C / 1 0 S / 1 0 C S ) ,
High Alarm Off Delay (d_off_time) : 10s 10-56V DC (DCV-11/11A/11C/11S/11CS)
Frequency :50/60 Hz (DCV-10/10A/10C/10S/10CS)
Low Alarm On Delay (d_on_time) : 20s
Supply Input Power Consumption :< 4 VA
Low Alarm Off Delay (d_off_time) : 10s Measuring Input Power Consumption :< 1 VA
RS 485: (DCV-10S/10CS/11S/11CS ) Measuring Input Resistance (Rin) :< 2M
Address : 1 Measuring Voltage Range :+/- 200V
Baudrate : 9600 Accuracy :0.5% ±1 Digit [(10% - 100%) x full scale] **
Relay Outputs (2 pieces) :2 N O , 5 A 1 2 5 0 V A ( D C V - 1 0 C / 1 0 C S / 1 1 C / 1 1 C S )
Parity : None Communication :MODBUS RTU (RS-485) Programmable.(DCV-10S/10CS/11S/11CS)
Analog Output: (DCV-10A/11A) Baudrate :2400 - 38400
Analog Output : 0 - 20 mA Address :1-247
Assign Hi : 200V Parity :None, Odd, Even
Analog Output :(DCV-10A/11A)
Assign Lo : 0V
Analog Voltage Output :0-10 V or 2-10 V
Period : 1 (second) Load Resistance :>= 1K2
Display Update Period :100ms (milliseconds).
Backlight : On Analog Current Output :0-20 mA or 4-20 mA
Contrast : 15 Load Resistance :<= 500ohm
Update Period :100ms (milliseconds).
Security
Accuracy :±0.01 % FS
Password Protection : Off
Period :1 - 600 seconds
Password : 0
35 36
Ambient Temperature : -20 ... 70°C 6. REGISTER TABLE:
Display : 2.5 inches Backlit LCD
Dimensions
Device Protection Class
: PR-20
: Double Insulation - Class II ( )
Bit Register Table
Casing Protection Class : IP 40 Description W/R Range Unit Multiplier Format
Terminal Protection Class : IP 00
DC Voltage Value 2
Wire Width (For Terminals) : 2.5mm2
Casing Material : Nonflammable Max. Measurement Value 2
Min. Measurement Value 2
Installation Type : Flush Mounting ( PR-20 )
Weight : 0.240 kg Shunt Current *
Shunt Voltage *
Installation Class : Class III
Panel Cutout Dimensions : 48X96 mm (PR-20)
Alarm 1 Activation Alarm 1 inactive
Alarm 1 active
** Measurement accuracy may change when measured waveform is not pure DC. (Measuring error may increase to 5% for half-wave
and full-wave rectified AC signals. Capacitive filter usage is suggested to increase the precision for measuring such signals.) It is
recommended to use Capacitive filter in order to improve accuracy of measurements. Alarm 1 Latch Function
Latch Inactive
Latch Active
37 38
Description W/R Range Unit Multiplier Format Description W/R Range Unit Multiplier Format
Alarm 1
Low Alarm
Alarm 1 F ON Delay
Contact Position Alarm 1
Inverted Low Alarm
OFF Delay
Alarm 1 Alarm 2
Alarm Type High Protection Active Activation Protection Inactive
Low Protection Active
Protection Active
Range Protection Active
Alarm 1 Alarm 2
High Warning Value 2 v Latch Function Latch Inactive
Alarm 1 Latch Active
9 Low Warning Value 2 v
Alarm 1 Alarm 2
High Hysteresis % Trip Function Trip Inactive
Trip Active
Alarm 1
c Low Hysteresis %
Alarm 2
Alarm 1 Contact Position
High Alarm second Inverted
D ON Delay
Alarm 1 Alarm 2 High Protection Active
High Alarm second Alarm Type Low Protection Active
E OFF Delay Range Protection Active
39 40
Description W/R Range Unit Multiplier Format Description W/R Alarm Status Unit Multiplier Format
Alarm 2
High Warning Value 2 v 0: Alarm doesnt count
Alarm1 Status 1: High Alarm
Alarm 2 v 2: Low Alarm
Low Warning Value 2
Alarm 2 v
High Hysteresis 1
0: Alarm doesnt count
Alarm 2 v Alarm2 Status 1: High Alarm
Low Hysteresis 1 2: Low Alarm
Alarm 2
High Alarm second
ON Delay
Alarm 2
High Alarm second
OFF Delay
Alarm 2
Low Alarm second
ON Delay
Alarm 2
Low Alarm second
OFF Delay
41 42
Description W/R Range Unit Multiplier Format Description W/R Range Unit Multiplier Format
Backlight Off
0 OUTPUT INACTIVE
Backlight On continuously
Analog Output 1 OUTPUT TYPE VOLT RANGE = 0-10 V
Type/Range Backlight Status Backlight On for 30 seconds
2 OUTPUT TYPE VOLT RANGE = 2-10 V Backlight On for 1 minute
3 OUTPUT TYPE CURRENT RANGE = 0-20 mA
Backlight On for 5 minutes
4 OUTPUT TYPE CURRENT RANGE = 4-20 mA
Backlight On for 15 minutes
Assign Hi v Contrast
v Average Period second
Comm. Address
Language
: : : : : P
43 44
7. MENU MAP
DEVICE ID DEVICE TYPE DEVICE ID DEVICE TYPE DEVICE ID DEVICE TYPE DEVICE ID DEVICE TYPE 001 01 05
ALARM 2
CNTCT POS CNTCT POS CNTCT POS
It returns to one from which
alarm setting is returned.
OFF
ALRM TYPE ALRM TYPE ALRM TYPE ALRM TYPE
HIGH
HGH VALUE LOW VALUE HGH VALUE HIGH HYS H ON DEL H OFF DEL LOW VALUE LOW HYS
Selected parameter is displayed
100 V 010 V 100 V 010 020.0 010.0 010 V 010
TRIP TRIP TRIP
L ON DEL
ALARMS
NO YKSK HIS DSK HIS D GECME S D DONME S BACK MENU
020.0
05 05 020.0 010.0
Selected parameter is displayed
L OFF DEL
47 48
Only valid for DCV-10A/11A.
0-20 mA
001 9600 NONE
mA
Last entered value is displayed.
ANLG OUT
BACK MENU
V
49 50
Selected parameter is displayed
RESET RESET MIN RESET MAX BACK MENU
LANGUAGE LANGUAGE
LANGUAGE
ENG
RESET MIN RESET MAX
If password is inactive.
If password is wrong.
FCTRY SET ENTR PASS ENTR PASS ENTR PASS
FCTRY SET
SETTINGS
DISPLYSET BACKLIGHT CONTRAST BACK MENU
DONE
YES 15
Selected parameter is displayed.
5 1
51 52
SECURITY PASS ACTV PASS CHNG BACK MENU
NO OLD PASS OLD PASS
If password is correct.
NEW PASS NEW PASS
AGAIN AGAIN
PAS CHNGD
Selected parameter is displayed.
111 000