TABLE 2. Thermodynamic Properties of
Water
TABLE 1. Saturated Solid/Vapor Water* Temperature Pressure
No.
K MPa
Temperature Pressure
No. Saturated Properties
(oF) (lb/in2 abs)
1 273.16 0.000612
1 −160 4.949.−8
2 280 0.000992
2 −150 1.620.−7
3 290 0.001920
3 −140 4.928.−7
4 300 0.003537
4 −130 1.403.−6
5 310 0.006231
5 −120 3.757.−6
6 320 0.010546
6 −110 9.517.−6
7 330 0.017213
7 −100 2.291.−5
8 340 0.027188
8 −90 5.260.−5
9 350 0.041682
9 −80 1.157.−4
10 360 0.062194
10 −70 2.443.−4
11 370 0.090535
11 −60 4.972.−4
12 380 0.12885
12 −50 9.776.−4
13 390 0.17964
13 −45 1.354.−3
14 400 0.24577
14 −40 1.861.−3
15 410 0.33045
15 −35 2.540.−3
16 420 0.43730
16 −30 3.440.−3
17 430 0.57026
17 −25 4.627.−3
18 440 0.73367
18 −20 6.181.−3
19 450 0.9322
19 −15 8.204.−3
20 460 1.1709
20 −10 1.082.−2
21 470 1.4551
21 −5 1.419.−2
22 480 1.7905
22 0 1.849.−2
23 490 2.1831
23 5 2.396.−2
24 500 2.6392
24 10 3.087.−2
25 510 3.1655
25 15 3.957.−2
26 520 3.7690
26 16 4.156.−2
27 530 4.4569
27 18 4.581.−2
28 540 5.2369
28 20 5.045.−2
29 550 6.1172
29 22 5.552.−2
30 560 7.1062
30 24 6.105.−2
31 570 8.2132
31 26 6.708.−2
32 580 9.448
32 28 7.365.−2
33 590 10.821
33 30 8.080.−2
34 600 12.345
35 610 14.033 82 400 0.1
36 620 15.901 83 500 0.1
37 630 17.969 84 600 0.1
38 640 20.265 85 700 0.1
39 647.1 22.064 86 800 0.1
Saturated Properties 87 900 0.1
40 273.16 0.000612 88 1000 0.1
41 280 0.000992 89 1100 0.1
42 290 0.001920 90 1200 0.1
43 300 0.003537 91 300 1
44 310 0.006231 92 400 1
45 320 0.010546 93 453.03 1
46 330 0.017213 94 453.03 1
47 340 0.027188 95 500 1
48 350 0.041682 96 600 1
49 360 0.062194 97 700 1
50 370 0.090535 98 800 5
51 380 0.12885 99 900 5
52 390 0.17964 100 1000 5
53 400 0.24577 101 1100 5
54 410 0.33045 102 1200 5
55 420 0.43730 103 300 10
56 430 0.57026 104 400 10
57 440 0.73367 105 500 10
58 450 0.93220 106 584.15 10
59 460 1.1709 107 584.15 10
60 470 1.4551 108 600 10
61 480 1.7905 109 700 10
62 490 2.1831 110 800 10
63 500 2.6392 111 900 10
64 510 3.1655 112 1000 10
65 520 3.7690 113 1100 10
66 530 4.4569 114 1200 10
67 540 5.2369 115 300 100
68 550 6.1172 116 400 100
69 560 7.1062 117 500 100
70 570 8.2132 118 600 100
71 580 9.4480 119 700 100
72 590 10.821 120 800 100
73 600 12.345 121 900 100
74 610 14.033 122 1000 100
75 620 15.901 123 1100 100
76 630 17.969 124 1200 100
77 640 20.265 125 300 500
78 647.1 22.064 126 400 500
Single-Phase Properties 127 500 500
79 300 0.1 128 600 500
80 372.76 0.1 129 700 500
81 372.76 0.1 130 800 500
131 900 500 8 −2.3206 300
132 1000 500 9 −3.1532 400
133 1100 500 10 −4.0156 500
134 1200 500 11 −4.909 600
135 400 1000 12 −6.790 800
136 500 1000 13 −8.803 1000
Condensed from U. Grigull, Private communication, January 18, 1995.
137 600 1000
138 700 1000 Materials prepared at Technical University München, Germany by U. Grigull
139 800 1000 and S. Marek. For a table as a function of tem-perature, see Grigull, U. and S.
Marek, Warme u. Stoff., 30 (1994): 1–8.
140 900 1000
141 1000 1000 t = the triple point (at 6.117 × 10−3 bar, 0.01 °C); vf = 0.0010021 m3/ kg: αf
= −67.42 × 10−6/K.
142 1100 1000
143 1200 1000 Other equations for properties are given by Jones, F. E. and G. L. Harris, J.
The values in these tables were generated from the NIST REFPROP software Res. N.I.S.T., 97, 3 (1992): 335–340, and by Wag-ner, W. and A. Pruss, J.
(Lemmon, E. W., McLinden, M. O., and Huber, M. L., NIST Standard Reference Phys. Chem. Ref. Data, 22, 3 (1993): 783–787. Steam tables include Walker,
Database 23: Reference Fluid Thermodynamic and Transport Properties— W. A., U.S. Naval Ordn. Lab. rept. NOLTR NOLTR-66-217 = AD 651105
REFPROP, National Institute of Standards and Technology, Standard Reference (0–1000 bar, 0–150°C), 1967 (72 pp.); Grigull, U., J. Straub, et al., Steam
Data Program, Gaithersburg, Md., 2002, Version 7.1). The primary source for the
Tables in S.I. Units (0.01–1000 bar, 0–1000 °C), Springer-Verlag, Berlin,
thermodynamic properties is Wagner, W., and Pruss, A., “The IAPWS Formulation
1995 for the Thermodynamic Properties of Ordinary Water Substance for General 1990 (133 pp.); Tseng, C. M., T. A. Hamp, et al., Atomic Energy of Canada
and Scientific Use,” J. Phys. Chem. Ref. Data 31(2):387–535, 2002. The source for rept. (30 props, sat liq & vap., 1–220 bar), AECL-5910 1977 (90 pp.). For
viscosity is International Association for the Properties of Water and Steam, Revised dissociation, see e.g., Knonicek, V., Rozpr. Cesko Acad Ved., Rada techn ved
Release on the IAPS Formulation 1985 for the Viscosity of Ordinary Water (0.01–100 bar, 1000–5000 K). 77, 1 (1967). The proceedings of the 10th
Substance, IAPWS, 1997. The source for thermal con-ductivity is the International
Association for the Properties of Water and Steam, Revised Release on the IAPS
international conference on the properties of steam were edited by Sytchev,
Formulation 1985 for the Thermal Conductivity of Ordinary Water Substance, V. V. and A. A. Aleksandrov, Plenum, NY, 1984; and for the 11th conference
IAPWS, 1998. Properties at the triple point temperature and the critical point by Pichal, M. and O. Sifner, Hemisphere, 1989 (550 pp.). Current information
temperature are given in the first and last entries of the saturation tables, on the properties of solid, vapor, and liquid water properties can be found at
respectively. In the single-phase table, when the temperature range for a given http://www.iapws.org.
isobar includes a vapor-liquid phase boundary, the temperature of phase
equilibrium is noted, and properties for both the saturated liquid and saturated For electrical conductivity, see e.g., Marshall, W. L., J. Chem. Eng. Data, 32
vapor are given (with liquid properties given in the upper line). Lines are (1987): 221–226.
omitted from the temperature-pressure grid of the single-phase table, when
the system would be in the solid phase or if there are potential problems with
the source property surface. The uncertainty in density of the equation of state is
0.0001% at 1 atm in the liquid phase, and 0.001% at other liquid states at pressures
up to 10 MPa and temperatures to 423 K. In the vapor phase, the uncertainty is
0.05% or less. The uncertainties rise at higher temperatures and/or pressures, but are
generally less than 0.1% in density except at extreme conditions. The uncertainty in
pressure in the critical region is 0.1%. The uncertainty of the speed of sound is
0.15% in the vapor and 0.1% or less in the liquid, and increases near the critical
region and at high temperatures and pressures. The uncertainty in isobaric heat
capacity is 0.2% in the vapor and 0.1% in the liquid, with increasing values in the
critical region and at high pressures. The uncertainties of saturation conditions are
0.025% in vapor pressure, 0.0025% in saturated-liquid density, and 0.1% in
saturated-vapor density. The uncertainties in the saturated densities increase
substantially as the critical region is approached. For the uncertainties in the
viscosity and thermal conductivity, see the IAPWS Release.

TABLE Thermodynamic Properties


of Water Substance along the Melting
Line.
T P
No. o
C Bar
1 0.0100 6.117 10-3t
2 0.0026 1.01325
3 −0.3618 50
4 −0.7410 100
5 −1.1249 150
6 −1.5166 200
7 −1.9151 250
Tabel Tekanan (P) dan Temperature (T) untuk CO2
Tabel Tekanan (P) dan Temperature (T) untuk Propana