ELECTRIC ACTUATOR AUMA SA 07.2÷16.2

 Multi-turn actuator for the CLOSED-OPEN function;


 Electric engine, with three-phase operation ( one phase operation), with
induction winding cage, insolation class F, with three thermistors wrapped in
Design: stator’s coils for overload protection.
 Cycle: S2-15 min.
 2 limit switches and 2 moment switches.
 Wheel for manual operation in case of emergency with hand lever for
triggering and automatically disconnecting the mechanism at engine turn-on.
 Wiring diagram KMS.
 Water protection IP67 according to EN60529
 Standard coating SILVER GREY ( similar to RAL 9007)
Environment  -25˚C and up to +80˚C
temperature:
Connecting  According to DIN ISO 5210.
flange:
 220V;230V;380V;400V;500V
Power  50HZ ( for the three-phase alternative power engines)
supply:  220V;240V;50Hz ( for the one-phase alternative power engines)
 24VDC ( continuous power)
Protection  IP 67
 IP58 protection
 Mechanical position indicator
 Potentiometer 4÷20mA
 Thermistors PTC ( according to DIN 44082)
Optional:  Cycle: S2-30min.
 Tandem moment and cycle limiter ( 2NC and 2NO for each direction)
 Explosion protection: II2G Eex IIC T4
 Control panel AUMA MATIC
 Control panel AUMATIC

Body, Caps, wheel: Aluminium alloy


Internal parts: Steel, Bronze alloy, Stainless Steel
Drive bush, gear cogs, pinions Carbon steel
IV- AUMA 1
IV- AUMA 1

 Local control
 OPEN-STOP-CLOSED buttons and indicating lamps ( OPEN-green light; DAMAGE- red light,
CLOSED- yellow light)
 Selective switch LOCAL-CLOSED-DISTANCE ( Lockable in all three positions)
 Reversing contactor switch with mechanical and electrical stopping devices.
 Entry/Exit signals.
 Entry signal OPEN – (STOP)-CLOSED at 24V cc from internal or external power source.
 Exit signal for the limit positions CLOSED/OPEN and selective switch in the
LOCAL/DISTANCE position.
 Warning signal with control relay ( phase warning, engine protection launched at half
cycle)
 Logical programmed control
 Automatic phase correction
 Power supply panel with control transformer at 24V cc
 Wiring diagram MSP 1110 KC3-A18E1 KMS TP 114/001
 Water protection IP67 according to EN60529
 Standard coating Silver-Grey ( similar to RAL 9007)
 Working environment temperature: -20˚C up to 40˚C
 Power supply connector with sealed terminal panel with double inside sealing and with an
entry bonnet for 3 wires (2xM25x1,5 and 1xM20x1,5)

 Local control
 OPEN-STOP-CLOSED buttons and indicating lamps ( OPEN-green light; DAMAGE- red light,
CLOSED- yellow light)
 Selective switch LOCAL-CLOSED-DISTANCE ( Lockable in all three positions) with double
contacts for distance indication
 Signal for collective damage through monitoring relay ( phase warning, engine protection
launched at half cycle)
 Logical programmed control
 Automatic phase correction
 Auto-adaptable positioner ( optional)
 Programmable signal relays
 Communication interface PROFIBUS or MODBUS
 Alfa-numerical display
 Monitoring and diagnostic
 Registration of functioning data
 Serial programming interface
 Power supply control panel with 24Vcc transformer
 Wiring diagram MSP 111700-F28E1 KMS TP104/201
 Water protection IP67 according to EN60529
 Standard coating Silver-Grey ( similar to RAL 9007)
 Working environment temperature: -25˚C up to 60˚C
 Power supply connector with terminal panel with an entry bonnet for 3 wires (2xM25x1,5
and 1xM20x1,5)