Equipment&TechnicalDetails
Equipment Make and model number Magnaflux Y7 Yoke Equipment SL.NO. 2016023708
Type of Magnetization
Calibration done and due date 27-02-19 TO 26-08-19 Yoke longitudinal
technique used
Magnetization current used
Type of magnetic field Longitududinal magnetic Field 1.6-2.2 amps(AC&DC)
and Amps
Method Non Florescent Application of particles Continuous spray
Magnetic particle brand name MAGNAFLUX Sensitivity Calibration
ASTM TEST BLOCK
Batch number and Expiry date 18E1005 MFD:MAY 2020 details
Ambient light intensity
Light intensity (Black light) 1095-1100 Lux (in case of florescent method)
---
Type of light intensity meter used Visible lite Calibration details 26-08-2019
Demagnetization details --- Remarks ---
Test observations
Total Number of indications found Total Number Non- Total Number
--- Acceptable -- Recordable/Acceptable --
Indications Indications
Indication location Map reference Results:No defect indications are observed hence the tested
----
No. component is acceptable according to the above standard.
Cleaning with
Post examination cleaning details
Solvent
Tested By Authorized signatory Reviewed By
Name:B. SANDEEP Name: V. VEERAMOHAN RAO Name:
LEVEL OF QUALIFICATION:ASNT LEVEL-II Signature:
LEVEL OF QUALIFICATION: ASNT LEVEL III
Signature:
Signature:
Format No: CMSS/FM/48B(MPT)
Rev.No: 00; DT: 01/01/2016
Page 01 of 01