Вы находитесь на странице: 1из 21

O.W.

Andersen

USER’S MANUAL FLD6


LAPLACIAN ELECTROSTATIC FIELDS

PROGRAM INSTALLATION

FLD6 is transmitted as a zip-file. It is extracted and installed in any directory (folder). The program can
also be installed on a memory stick and run from there.

RUNNING THE DEMO INPUT

Here all the Command Prompt commands and file names will be in capital letters. However, they are
case insensitive, and small letters can also be used.

To run the program with an input file DEMO.INP, enter:

RUN DEMO.INP

After a few seconds, a field plot with 19 equipotential lines appears on the screen. It has been drawn on
a Visual Basic Form. If the picture appears to be cropped or too small, adjust the file SIZESCR.FIL. At
the same time a bitmap picture file PLOTFILE.BMP has been produced. Close the form and enter
command:

PLOT

The plot now reappears in a standard Windows program. The tic-marks to the left and at the bottom
show the positions of horizontal and vertical finite element grid lines. Electrodes are red, and insulation
is green.

If it is now desired to print the field plot, crop the picture file first to remove empty space and save it.
Microsoft Office Picture Manager or Microsoft Paint can be used for that. Rather than printing it
directly, it is recommended to transfer the picture file to Microsoft Word. Here it can easily be resized
and comments added before printing.

Output from FLD6 is stored in file OUTPUT. To display it on the screen, enter:

FILE OUTPUT

Batch command FILE starts the standard Windows program NOTEPAD. It will be used here for
viewing, editing and printing text files. The first time it is invoked, it should be set to Courier New size
9, word wrap, and to no top and bottom extra text when printing. The window should always be
maximized.
-2-

To display the finite element grid on the screen, enter:


GRID
After the form is closed, the grid also reappears with the command:
PLOT

INPUT

The demo input file can be viewed with the command:

FILE DEMO.INP

What the numbers mean can be found on the input sheet, page 5. For an explanation of what else can be
done with the input file, copy it first to a new file with the command:

COPY DEMO.INP NEW.INP

Introduce headings with the command:

HEADINGS NEW.INP

To see how the file now has been modified, enter:

FILE NEW.INP

The abbreviated headings on the input file also explain the numbers. With a little experience, that
explanation suffices to enter new numbers and to make up new input files.

Old input as similar as possible is first copied to a new input file. Then headings are introduced and the
file changed. Numbers always start in columns 1, 11, 21 and so on. They can be entered with or without
decimal point.

Before the new file can be run, the headings must be removed. Do this first with:

CLEANUP NEW.INP

A file without headings can have headings introduced and be viewed at the same time with:

HEADFILE NEW.INP
-3-

Input must be entered very carefully, following explanations on the input sheets and instructions
elsewhere in this manual. Small mistakes like a comma instead of a decimal point or a number starting
in the wrong column are not tolerated. Some mistakes are caught by the program and are explained on
the output. Another way to catch mistakes is by giving a command such as:

CHECK NEW.INP

The input must here be in the standard format, without headings. A picture similar to a flux plot, but
without flux lines, will be displayed on the screen. Mistakes with the geometry can be caught this way.

Headings can also be removed and the file run at the same time with:

CLEANRUN NEW.INP

Another command which does the same, and also modifies the input grid automatically, if necessary to
satisfy program requirements, is:

CORRECT NEW.INP

Modified input will replace the original input, in this case in file NEW.INP. If desired, the original input
can be retrieved from file INP1.FIL.

Before modification of the grid with CORRECT, it should be reasonably close to being right, and the
number of vertical and horizontal break lines should be less than the maximum 64 with a good margin.
However, even so, there is no guarantee of a successful modification.
-4-

PROGRAM DESCRIPTION

An early version of the program is described in the paper:

O.W. Andersen, "Laplacian Electrostatic Field Calculations by Finite Elements with Automatic Grid
Generation", IEEE Transactions on Power Apparatus and Systems, vol. PAS-92, Sept./Oct. 1973,
pp. 1485-1492.

Numerous improvements have been made since this paper was written. One of them is that the finite
element equations are now solved directly by Gaussian elimination, instead of as previously by iteration.
Iterative solution used to have significant advantages in terms of speed and storage requirements, but
with newer computers, it is more important that Gaussian elimination is safer and more accurate.

The grid generation has also been vastly improved, to give the best possible grid under all circumstances
with maximum numerical accuracy, and a minimum of restrictions on the input specifications.
LAPLACIAN ELECTROSTATIC FIELDS PROGRAM FLD6 INPUT SHEET

Numerical data are entered with the first digit in columns 1,11,21 etc., as indicated. (Does not apply to coordinate lines.)
Decimal point is optional.

IDENTIFICATION (line 1): No commas and max. 80 characters, including blanks

Col. Data Line


FLAT / AXI-SYMMETRIC FIELD (1 or 2) 1
MINIMUM RADIUS (zero if flat field) 11 2
SCALE, INPUT DRAWING (usually 1) 21
CAPACITANCE REQUIRED (0 or 1) 31
1 3
VERTICAL GRID 11 4
DENSITY BREAK LINES 21 5
(Remainder of lines must 31 6
be filled out with zeros. 41 7
Max. 300 grid lines and 51 8
60000 nodes.) 61 9
71 10
COORDINATE LINE(S) *1 11
1 12
HORIZONTAL GRID 11 13
DENSITY BREAK LINES 21 14
(Remainder of lines must 31 15
be filled out with zeros. 41 16
Max. 300 grid lines and 51 17
60000 nodes.) 61 18
71 19
COORDINATE LINE(S) *1 20
DETAILED INFORMATION REQUIRED BETWEEN
FIRST HORIZONTAL LINE ) 1 21
LAST HORIZONTAL LINE ) zeros, if not 11 22
FIRST VERTICAL LINE ) required 21 23
LAST VERTICAL LINE ) 31
SCALE, FIELD PLOT (used only for printer or plotter, not on screen) 1
NUMBER OF EQUIPOTENTIAL LINES (19 gives 5% volts per line) 11 24
RELATIVE PERMITTIVITY, IF NOT GIVEN OTHERWISE 21
NUMBER OF CONTOUR LINES (max. 500) 31

For each contour line:


NUMBER OF POINTS (max. 150, 1500 total) *2 1 25
RELATIVE PERMITTIVITY (zero for electrodes) 11 27
POTENTIAL, VOLTS (zero, except at electrodes) 21 29
CODE (2 at electrodes, otherwise usually zero) *3 31
COORDINATE LINE(S) *1 26,28,30

NUMBER OF POINTS (max. 150, 1500 total) *2 1 31


RELATIVE PERMITTIVITY (zero for electrodes) 11 33
POTENTIAL, VOLTS (zero, except at electrodes) 21 35
CODE *3 31
COORDINATE LINE(S) *1 32,34,36

NUMBER OF POINTS (max. 150, 1500 total) *2 1 37


RELATIVE PERMITTIVITY (zero for electrodes) 11 39
POTENTIAL, VOLTS (zero, except at electrodes) 21 41
CODE *3 31
COORDINATE LINE(S) *1 38,40,42

*1: See separate description.


*2: Actually pairs of coordinates, codes, etc.
*3: Code 1 excludes an area from the calculations, with equipotential lines perpendicular.
-6-

SPECIFICATION OF INPUT

LINE 1. The identification can consist of up to 80 characters, including blanks. Most combinations of
letters, numbers and special symbols on the keyboard can be used.

LINE 2. The drawing is always oriented with the x or r-axis horizontally, and with the y or z-axis
vertically. The origin for input coordinates must be in a position where all the coordinates come out
positive, and is often in the bottom left corner. For axi-symmetric fields, true radii are often given as
input.

Axi-symmetric problems always have the z-axis to the left. The minimum radius is the true radius from
the axis of symmetry. It will be equal to zero if the axis of symmetry is the left field boundary.

The scale of the input drawing (a smaller drawing has a smaller scale) should nearly always be specified
as one. In any case, it should be between 0.1 and 10, for the output to contain a sufficient number of
significant digits. If in fact the scale is outside of this range, it should be multiplied by an appropriate
factor, for example 0.1 or 10, to make it come out right. The specified minimum radius (col. 11) and the
output information must then also be modified accordingly.

LINES 3 TO 10. Line numbers are entered for vertical grid lines, where the grid density changes (grid
density break lines). In the example in figures 3 and 4 of the IEEE paper, they are 1, 13 and 25.

Field strengths are assumed to be constant within each triangle in the numerical solution, and the grid
should be fine enough for this to be true within acceptable accuracy, especially in critical regions. In any
case, the grid lines must be close enough, so that contour line points are at least as far apart as the grid
lines in the same region.

LINE(S) 11. One or more lines which contain x or r-coordinates of the grid density break lines are
entered here. Up to 10 coordinates are entered on one line. Each coordinate consists of a five digit
number with one digit after the decimal point. Then there is a blank before the next coordinate. When a
coordinate is less than 1000 mm, it is entered with leading zeros. In the example, the coordinates are:

0000.0 0050.0 0120.0

LINES 12 TO 19. In the example, horizontal grid density break line numbers are 1, 9 and 39.

LINE(S) 20. y-coordinates in the example:

0000.0 0040.0 0100.0


-7-

LINES 21 TO 23. The detailed output information increases the bulk of the output and the computing
time significantly, and should therefore be limited to those areas where it is of real interest. The field
strengths in triangles adjoining those with the highest calculated values will give valuable information
about the accuracy of the results.

If only one area of detailed output is desired, lines 22 and 23 are filled out with zeros.

LINE 24. The scale of the field plot is unimportant for the plot on the screen. It is used for the plot on
the printer or plotter, but if the value is given too large, it is reduced automatically by the program. The
plot is automatically tilted 90 degrees, if this permits a better utilization of the paper.

LINES  25. It is important that the contour lines are entered in a proper sequence, since the grid is
fitted to line segments that are common for two or more lines only the first time they are entered. This
usually means that electrodes should be entered first, so that they receive the proper potentials and codes
throughout.

Along straight line boundaries, it is sometimes desirable to be able to specify a linear variation of
potential. This can be done by using code 2.1, with the potential of the first point in column 11, and of
the last point in column 21.

The number of points (col. 1, line 25) is used only to enable the program to read the input properly. It
actually means the number of pairs of five digit numbers, entered in coordinate line format. This should
be kept in mind when preprogrammed shapes (see separate instructions) are used to describe the contour
lines.

COORDINATE LINES

A line can contain one, two, three, four or five pairs of coordinates, codes, etc. When more lines are
needed because there are more than five pairs, only the last line can have fewer than five.

Each coordinate usually consists of a five digit number, with one digit after the decimal point. Then
there is a blank before the next coordinate. The x or r-coordinate is entered first, then the y or
z-coordinate. When a coordinate is less than 1000 mm, it is entered with leading zeros. Example:

0000.0 0100.0 0030.2 0400.5 0102.6 1206.8


x y x y x y
point 1 point 2 point 3

Other possibilities are:

123.45 Normally coordinates can be rounded to the nearest 1/10 mm.


1234.56 To be avoided, because no blank will separate the next number.
-123.4 Permissible as coordinate of center of circular arc.
-8-

PREPARATION OF INPUT DRAWING

The preparation of the input drawing for transfer of coordinates should be done with great care.

1. A rectangular section is framed (by pencil), where the field is to be calculated.

2. If the boundary conditions make it desirable, estimated flux lines can be drawn in, deleting parts of
the section from the calculations (Fig. 10 of the IEEE paper). This is rarely necessary.

3. Positions of grid density break lines (Fig. 3 of the IEEE paper), whose coordinates are to be entered
on input lines 11 and 20, are marked on a horizontal and a vertical line on the drawing. The spacing
between the lines can also be put in, and the line numbers which are to be entered on input lines 3-10
and 12-19. During this process it is important to make mesh sizes reasonably in accordance with the
requirements in the various areas, with the finest meshes in the regions of the highest field strengths. It
is also important to observe requirements 8 and 10 in the "Instructions for Entry of Coordinates". Grid
lines must always be spaced at least as close to each other as the contour line points in the same region.
If they are not, the situation may be remedied by running program CORRECT (see page 3).

4. Now all the points along electrodes, dielectric materials and estimated flux lines, which are to be
entered, are marked on the drawing with their coordinates. This is done in accordance with "Instructions
for Entry of Coordinates".

INSTRUCTIONS FOR ENTRY OF COORDINATES

1. The position of the reference point (origin) should normally be at the bottom left corner. However,
for axi-symmetric fields, true radii can be given as input.

2. The grid lines are horizontal and vertical, and the drawing should be oriented accordingly. For axi-
symmetric problems, the axis of symmetry must be in the vertical direction (the same as the y-direction
in flat, two dimensional problems), with the axis to the left.

3. On input line 11 only x(r)-coordinates are entered, on line 20 only y(z)-coordinates.

4. Contour lines can be open or closed curves. Single points can also be entered. For closed curves, the
last point must have the same coordinates as the first. Only for closed curves, relative permittivity can
be given different from zero. Whether the curves are entered in a clockwise or counter-clockwise
direction is unimportant.

5. When points are supposed to have the same coordinates, or a point is supposed to be on a line
segment belonging to another contour line, a maximum error of 0.01 mm is permitted, to allow for slight
inaccuracies.

6. When the same line segment is entered twice, the grid is only fitted to the line segment the first time.
Therefore, whenever electrodes have line segments in common with other contour lines, the electrodes
should be entered first, to make sure that all the points on the electrodes receive the proper potential and
code.
-9-

7. A maximum of 150 points is permitted per contour line, for a maximum of 500 lines, but the total
number of points must not exceed 1500. If more than 150 points are required for a contour line, it must
be divided up into two or more parts.

8. The points should not be closer to each other than necessary, and with a spacing at least equal to the
mesh size in that region (except when the points coincide).

9. If a contour line is put in outside of the section boundary, the program will move it to the section
boundary.

10. When part of a contour line follows a section boundary, this part must be entered first, and points
inside of the boundary must be further away from it than half a mesh size. This avoids problems that
otherwise might arise due to grid points being unavailable on the boundary when this part of the line is
fitted.

11. If a portion of the section is to be excluded from the calculations, a closed curve around this portion
is specified with code=1. Permittivity and potential should be given as zero. Equipotential lines will
enter at right angles.

12. In program FLD6, conducting media with floating potentials can be entered only as closed curves
(conducting bodies). If in fact it is an open line (a surface), it must be approximated as a thin body.
Conducting bodies are treated as dielectric materials with a high fictitious permittivity, such as 9000.

For conducting surfaces, more accurate solutions are obtained by using program FLD7, Complex
Potential Electric Fields (see separate instructions). A high fictitious surface conductivity is specified,
such as 9000 1/Gohm.

13. Problems have sometimes arisen when three lines meet in a point at sharp
angles, as shown in the figure. In such a case, the middle line must not be entered
last, because grid points may then no longer be available for the line fitting.

14. An insulated electrode is entered with the outer contour first, with specifications for the insulation,
and then the inner contour, with specifications for the electrode.

15. An electrode could have a shape as shown in the figure,


an open line connected to a closed curve. In such a case, the 1 2 3
two parts should be specified as two separate contour lines.
Only then the points within the area 2-3-4-5-2 will be recognized 5 4
as being inside a closed curve, and will receive fixed potentials.

If only one contour line is used to describe the electrode, the program will still work if point 2 is put in
twice, also as an intermediate point between points 1 and 3. But the program running time will be longer
than necessary, and the field strengths inside of the electrode might not come out exactly zero, because
of numerical errors.

Intermediate points are only put in automatically by the program when they come from other contour
lines, as in the example in the section "Preprogrammed Shapes".
- 10 -

ERROR MESSAGES

The program aborts and prints out one or more of the following error messages, if it is necessary to
modify the input.

1. The number of horizontal or vertical grid lines is more than 300.

2. The number of nodes in the grid is more than 60000.

3. There are more than 500 contour lines.

4. The contour line is described by more than 150 points.

5. The total number of points exceeds 1500.

6. The permittivity is given different from zero, and the last point on the contour line is not equal to the
first.

7. The line fitting was interrupted for line segment - near -. (Coordinates define the line segment and the
point where the line fitting got stuck.)

8. This point is too close to the preceding point -. (The point is defined by its coordinates.)

9. The program has moved node no. - from one line to another line which is too close. (The node is
defined by its number and its coordinates.)

10. The area came out negative or zero for triangle with -. (The triangle is defined by its node numbers
and coordinates.) Change line sequence or move grid lines.

11. Coordinates of grid density break lines are not in increasing order.
- 11 -

PREPROGRAMMED SHAPES

Two preprogrammed shapes that can be entered in a simplified manner are used very frequently, circular
arcs and rectangles with horizontal and vertical sides. The way they are entered will be explained by
means of the example in the figure.

mm electrode
50

30
25

=2 =3
10

electrode
0 30 45 65 95 110

The bottom electrode is specified only by its two end points. The intermediate points are put in
automatically by the program.

The region with  = 2 includes a circular arc at the upper left corner. It is somewhat roughly drawn,
but is supposed to have 5 points, between which straight line segments are drawn by the program. It can
be specified as follows:

0030.0 0000.0
0065.0 0000.0
0065.0 0025.0
9000.0 0001.0 Codes
0005.0 0015.0 Number of points and radius
0045.0 0010.0 Coordinates of center (can be negative)
0090.0 0180.0 Starting angle and finish angle (degrees)
0030.0 0000.0

An x-coordinate 9000 mm is recognized by the program as a code, telling it that a preprogrammed


shape of some kind follows. The value 1 in the corresponding y-position indicates that the shape is a
circular arc.

Angles are measured counter-clockwise from the horizontal, in the usual way. If the contour line
progresses through the arc counter-clockwise, as in the example, the finish angle must be greater than
the starting angle. Conversely, if the progression is clockwise, the finish angle must be smaller than the
starting angle.

The region with  = 3 is a rectangle with horizontal and vertical sides, which can be specified as
follows:

9000.0 0002.0 Codes


0065.0 0000.0 Coordinates of lower left corner
0095.0 0030.0 Coordinates of upper right corner
- 12 -

Right angle insulation barriers with sharp and rounded corners have also been preprogrammed, because
of their use in insulation structures of large transformers and reactors.

SHARP RIGHT ANGLE BARRIERS (4 possible orientations)

X2, Y2
9000.0 0004.0 Codes
X1 Y1
X2 Y2
T1 T2
Th’k = T2

Th’k = T1

X1, Y1 X1, Y1

X2, Y2

CURVED RIGHT ANGLE BARRIERS (4 possible orientations)

The angles are similar to the ones shown above, except that the right angle corner is rounded. This
makes T1=T2=T, and the specifications are:

9000.0 0005.0 Codes


X1 Y1
X2 Y2
T R Thickness and inside radius of corner

In the region of the rounded corner, it is important that the grid is sufficiently dense. It will usually be
satisfactory to have the line spacing no more than T or (outside radius)/5, whichever is smaller.
7 contour line points are generated along the inside radius, 8 along the outside radius.
- 13 -

POST PROCESSING

After the main program has been run, the run identification and all the essential calculated and input
information are in file FOR.FIL, and can be retrieved for further processing. This includes all the
potentials and node and contour line coordinates.

Two post processors are supplied with the program, both in source code and in executable versions.
One of them draws a graph of field strengths along or perpendicular to a specified line, and is started
with the command:

GRAPH

If an open contour line is drawn only for the purpose of calculating field strengths along it, permittivity,
potential and code should all be given as zero. Points along it must be specified wherever it crosses or
touches other contour lines.

Another post processor is for analysis of breakdown stresses in oil and creepage stresses along
transformer board in oil. Curves are drawn for stress distribution, and comparisons can be made
directly with permissible limits. It is based on a method proposed by the Swiss insulation manufacturer
Weidmann and is started with the command:

WEIDMANN

It is recommended to have printed output available before running GRAPH and WEIDMANN, in order
to answer the questions on the screen. Coordinates must be given accurately, down to the last digit.

The Fortran source code for both post processors is in file PPROC.FOR. It contains numerous
comment lines, and new post processors can be added by the user, if desired.
- 14 -

POLARITY REVERSAL

When a dc voltage is applied to an insulation structure, at first there will be a capacitive distribution of
potentials. The distribution can be found by running FLD6 in the normal way, with permittivities
specified for the different materials.

After considerable time, in the order of minutes or even hours, the charges throughout the structure will
have reached an equilibrium state, and the potential distribution will be resistive. It can be found by
running FLD6 with permittivities replaced by conductivities.

If now the polarity of the dc voltage is reversed, this involves a sudden change equal to twice the
original voltage. Since again considerable time will elapse before the charges reach their new
equilibrium state, at first there will be a capacitive distribution due to the step voltage, superimposed on
the resistive distribution before the change. If Vac is the potential at a point in the insulation calculated
for capacitive distribution, and Vdc is the potential calculated at the same point for resistive distribution,
immediately after the polarity reversal, the potential will be (or with opposite signs):

Vpr = 2Vac - Vdc

The highest and lowest potentials are no longer necessarily at the electrodes, and the difference between
them will normally be considerably higher than for the purely capacitive or resistive distribution,
sometimes approaching twice the value. This, combined with a very uneven distribution across materials
of different characteristics, can result in extremely high stresses in sometimes unexpected areas.

Two input files PRAC.INP and PRDC.INP are supplied with the program. They are for ac and dc
distribution respectively, for a very simple insulation structure. The only difference between them is that
permittivities in PRAC.INP have been replaced by conductivities in PRDC.INP.

If it is desired to study the capacitive and resistive distributions first, this can be done in the normal way
with the commands:

RUN PRAC.INP and


RUN PRDC.INP

To get the solution at polarity reversal, use the command:

PR PRAC.INP PRDC.INP

The program then solves the two cases in sequence, and superimposes the potentials from the two
solutions in the proper way. The field plot and the program output will be for polarity reversal.

One application of this is in transformers for HVDC transmission lines. The insulation structures are
partly stressed by dc voltages, which change polarity during transitions between rectifier and inverter
operation.
- 15 -

ANALYSIS OF BREAKDOWN AND CREEPAGE STRESSES IN OIL

It was mentioned on page 13 that the program has a post processor called WEIDMANN. It is used for
the analysis of breakdown stresses in oil and for creepage stresses along transformer board in oil. The
method was developed by H. Weidmann AG, Switzerland.

Creepage strength is a function of the length of the creepage path, and follows a hyperbolic function in a
homogeneous field, similar to the breakdown strength of oil versus gap length.

Creepage strength of transformer board in oil, approximately:

kV/mm = 15 * mm-0.37 rms

Breakdown strength of oil, approximately:

kV/mm = 21.5 * mm-0.37 rms

These curves are drawn by the post processor, and can be compared with actual stresses. The problem,
however, is how to relate actual stresses to those in a homogeneous field. An example will explain the
procedure.

Fig. 1 shows a field plot for a 400 kV "Faltenbalg" terminal connection in a transformer, and Fig. 2
shows a bar graph of the creepage stress along the surface of the insulation. Post processor
WEIDMANN analyses this stress, and draws the creepage stress distribution curve on Fig. 3. The
criterion for a satisfactory design is that this curve is under the creepage stress limit curve with a
sufficient margin. The kV/mm at a certain point on the stress distribution curve is the maximum average
stress for the corresponding length.

As an example, the stress at the 100 mm point is found by taking a length 100 mm as shown on Fig. 2,
and moving it back and forth to a position where the average stress for this length is a maximum. This
average stress is the 100 mm point on the stress distribution curve on Fig. 3.

The first point on the stress distribution curve gives the maximum calculated stress along the creepage
path, at a length equal to the corresponding length of the triangle side in the finite element calculation.
The last point on the stress distribution curve gives the average stress along the whole length of the
creepage path.

The end points of a creepage path are points where either the stress changes direction, or where it goes
down to zero and remains there for a considerable length.

Analysis of breakdown stresses must be made for one oil gap at a time (between insulation barriers or
electrodes).
After
RUN FALTENBG.INP (not in demo)

Fig. 1
After
GRAPH
Contour line 17

Fig. 2
After
WEIDMANN
Actual/calculated field strengths 6300
Contour line 17

Fig. 3
- 19 -

THE COMMAND PROMPT ENVIRONMENT

The Command Prompt window should be maximized and the size adjusted to fill the screen after right
clicking the top title bar. Cursor size small and letter size 12x16 pixels are recommended. If Command
Prompt goes into full screen mode by an application, it can be brought back with Alt-Enter.

Since many PC users are not familiar with Command Prompt, here are some hints and frequently used
commands. The commands are examples and may be modified in obvious manners. Large and small
letters are interchangeable.

Commands given once on startup, perhaps in a STARTUP.BAT file:


SET COPYCMD=/Y Deactivates warning on overwriting existing files.
PATH=C:\SYSTEM;C:\QBASIC Specifies search paths for executable files.
SUBST P: C:\DRIVEP Substitutes drive P for directory (or folder) C:\DRIVEP making P a virtual
drive (or unit).

Other commands:
C: Moves to unit C or another unit.
CD\ Changes to base directory.
MD GRAPHICS Makes directory GRAPHICS.
CD\GRAPHICS Changes directory to GRAPHICS, just below the base directory.
COPY OLD.INP NEW.INP Copies old file OLD.INP to a new file NEW.INP.
COPY /? Explains options available for command COPY.
REN OLD.INP NEW.INP Renames OLD.INP as NEW.INP.
DEL OLD.INP Deletes OLD.INP.
DIR *.INP Lists all files in the directory with extension INP.
DIR *.I?? Lists all files in the directory with three letter extension starting with I.
START NOTEPAD OUTPUT Invokes Windows program NOTEPAD with file OUTPUT.
START PLOTFILE.BMP Starts a standard Windows program to process the bitmap file.
After
RUN DEMO.INP
After
GRAPH