Академический Документы
Профессиональный Документы
Культура Документы
Agregates 20mm,10mm,crus
sand,river sand, and admixtu
Sample Description
(Fosroc conplast Sp 440
superplasticizer)
1
Agregates
2 20mm,10mm,crus
sand,river sand, and admixtu
Sample Description
(Fosroc conplast Sp 440
superplasticizer)
Dt. of Sample
12/9/2018
Received
Dt. of Test
From 12/10/2018 Onwards
Conducted
CO
A -1 STIPULATIONS FOR PROPORTIONING
a) Grade designation
b) Type of Cement
c) Maximum nominal size of aggregate
A -2 SOURCE OF MATERIALS
1
3
a) Coarse Aggregate (20mm & 10mm)
b) Fine aggregate (Crushed sand)
c) Fine aggregate (Natural sand)
d) Cement
1
4
1
5
A - 4 TARGET STRENGTH FOR MIX PROPORTIONIN
Characteristic Strength of Concrete
Current Margin as per IS code (4x1.65)
Therefore, Target strength
CONDITION
1
6
CONDITION
Volume of C
corrected volume for 0.47 W/c
ratio
A-9MIX CALCULATIONS
The mix calculations per unit volume of concrete
a) Volume of Concrete 1.0
b) Volume of Cement Mas
Specific
= (250/3.15x1/10
= 0.0789
c) Volume of water Ma
Specific
1
7
= (165/1x1/1000
= 0.165
= 0.0037
f) Volume of all in aggregate
agg = [a - (b+c+d+e)
= 0.705
g) Mass of 20mm aggregate
=
e x volume of
= (0.705 x 0.38 x
1
8
= 780
h) Mass of 10mm aggregate
=
e x volume of
= (0.705 x 0.17 x
= 348
i) Mass of Fine aggregate (crushed sand)
=
= 529.554
= (0.705 x 0.18 x
= 337
A-10 MIX PROPORTIONS& WATER CORRECTION
In case of dry condition of aggregate, the excess
Ingredients SSD W
Cementitious (cement+fly ash)
Cement
Fly ash
Water
1
9
Coarse aggregate (20mm)
Coarse aggregate (10mm)
Natural sand
Crushed sand
Admixture
Density
A-11 Compressiv
Date 25/11/2018
S.n
weight in gms Density (gm/cc)
o.
1 8676 2.571
1
10
2 8676 2.571
3 8246 2.443
4 8365 2.479
5 8536 2.529
6 8632 2.558
Verified by
P.S. Chouhan
Quality Head
1
11
TEST REPORT
D. Page No.
ver at Butibori -
KM 26.280 on
the state of Report No.
xecuted on EPC
Report Date
1, Vishnu
Customer Ref
ondhwa Road,
No.
11037
1
12
Sampled By
Name of Test
M25
Ultra tech OPC 53 Grade Confirming to IS:269_2015
20 mm
0.55
200 mm
130 mm
Moderate
Chute
Good
Crushed angular aggregate
300 kg/cum (As per IS 456:2000 table no.5)
450 kg/cum ( As per clause no. 8.2.4.2 of IS 456 2000)
Fosroc conplast Sp 440 superplasticizer
1
13
= Robo Silicon pvt. ltd.
= Robo Silicon pvt. ltd.
= Bhandara river
= Ultra tech Cement
OPC
3.168
1
14
Natural Crushed
20mm 10mm
sand sand
1
15
ROPORTIONING
=
=
=
US CONTENT
0.47
351.1 kg/cum
re, minimum cement content =
350Kgs/Cum
Cementitious content 100.03
= = 350-100 250
= 165Kgs.
COARSE AGGREGATE AND FINE AGGREGATE CONTENT
ADJUSTMENT
1
16
Volume of Coarse Aggregate(%) Volume of Fine
61.0 39.
= 56%
= 100-56 = 45
(Hence, Conforming to All In Agregate Gradation, IS-383)
1
17
(165/1x1/1000)
cum
= 4.20Kgs
0.0037 cum
[a - (b+c+d+e) ]
0.705 Cum
1
19
780 772
348 345
337 334
530 520
4.20 4.20
2514 2514
Load at
Date of
Failure Strength (N/mm2) Average
casting
(KN)
462.50 20.56
1
20
458.30 20.37
463.80 20.61
20.45 15/11/18
458.50 20.38
459.60 20.43
457.80 20.35
For Becque
Mr.
autho
1
21
1 of 4
2205
12/24/2018
Nil
1
22
Customer
IS10262:2009
269_2015
)
S 456 2000)
1
23
1 of 1
N
1
24
Natural % Passing
As Per Table 5 of IS-383
sand combine
1
25
20N/mm2
6.6N/mm2
26.6N/mm2
0.55
0.47
165Kgs/Cum
Say 350Kgs/Cum
300Kgs/Cum
say 100Kgs/cum
Kgs/cum
ONTENT
ENT
1
26
Volume of Fine Aggregate(%)
39.0
1 of 2
, IS-383)
1
27
1
28
ne aggregate x 1000
1 of 3
1
29
772 3.12 3.09
345 1.39 1.38
334 1.35 1.34
520 2.12 2.08
4.20 0.02 0.02
2514
( As per IS 516 )
Volume in CC 3375
Area mm2 22500
Date of Age in
Remarks
testing days
1
30
28 day compressive
22/11/18 7
strength awaited
1 of 4
1
TEST REPORT
Name of Customer T AND T INFRA LTD. Page No. 1 of 5
Construction of Flyover at
Butibori - MIDC T- Junction at KM
T & T/NHAI/Butibori/2018/14 Date
Name of Work 26.280 on NH-44 (old NH-7) in Customer Ref No.
09/12/2018
the state of Maharashtra to be
executed on EPC mode.
Dt. of Sample
12/9/2018 Name of Test Mix Design of M25 Grade concrete
Received
Dt. of Test
From 12/10/2018 Onwards Test Method IS10262:2009
Conducted
CONCRETE MIX PROPORTIONING
A -1 STIPULATIONS FOR PROPORTIONING
a)Grade designation M25
b)Type of Cement OPC 53 Grade Ultra tech Cement Confirming to IS:269_2015
c)Maximum nominal size of aggregate 20 mm
e)Maximum water - cement ratio 0.55
f)Workability Initial 220 mm
30 min 130 mm
g)Exposure condition Moderate
h)Method of concrete placing Chute
i)Degree of supervision Good
j)Type of aggregate Crushed angular aggregate
k)Minimum cement content 300 kg/cum (As per IS 456:2000 table no.5)
l)Maximum cement content 450 kg/cum
m)Chemical admixture type Fosroc Conplast SP 440 Superplatiziser Admixture used
A -2 SOURCE OF MATERIALS
a) Coarse Aggregate (20mm & 10 = Robo Silicon PVT LTD
b) Fine aggregate (Natural sand) = Bhandara river
c) Cement = Ultra tech Cement
20mm 10mm
Sieve
Size(mm)
40 100.00 100.00
20 88.12 100.00
4.75 0.00 6.56
0.600 0.00 0.65
0.150 0.00 0.30
120
100
80
f passing
60
% of passing
60
40
20
0
0
A-7CALCULATION OF CEMENT C
Adopted Water cement ratio =
Cement content = 154/0.44=
As Per IS 456 at Moderate Expo
350 > 300 Hence O.K.
Therefore, Adopted Cement Con
And Water Content
10 mm aggregate & Fine Aggregates - TABLE 5 o
COMBINED AGGREGATE GRADATION
% Passing of All in agrregates ( Blending
Natural
20mm 10mm
sand
38.00% 22.00%
OR MIX PROPORTIONING
of Concrete =
code (4x1.65) =
=
CEMENT RATIO
Ratio as per IS 456 from tab =
opt water - cement ratio as =
CONTENT
ed workability
en as - =
ENT CONTENT
tio = 0.44
44= kg/cum
e Exposure, minimum cement content =
Natural % Passing
As Per Table 5 o
sand combine
25N/mm2
6.6N/mm2
31.6N/mm2
0.55
0.44
154Kgs/Cum
Say 350Kgs/Cum
nt = 300Kgs/Cum
dation)
er Table 5 of IS-383
Upper limt
100
100
50
35
6
100
2 of 5
A-8PROPORTION OF VOLU
CONDITION
c) Volume of wate
d) Volume of Chem
Chembond @ percen
by mass of cem
e) Volume of all in
f) Mass of 20mm
g) Mass of 10mm
h) Mass of Fine a
OF VOLUME OF COARSE AGGREGA
NDITION
Volume of Coa
of Chemical Admixture
percent 0.70%
s of cementitious material)
Mass of Che
Specific Gra
=0.0021
of all in aggregate
agg =[a - (b+c+d) ]
= 0.733
f 20mm aggregate
= e x volume of C
1000
= (0.733 x 0.38 x
= 792
f 10mm aggregate
= e x volume of C
1000
e x volume of C
1000
= (0.733 x 0.22 x
= 455
f Fine aggregate (River sand)
=(0.733x 0.4 x 2.
= 777
GGREGATE AND FINE AGGREGATE
ADJUSTMENT
me of Coarse Aggregate(%)
64.0
te shall be as follows:
Cum
Mass of Cement
ecific Gravity of Cement
168x1/1000)
Cum
Mass of water
ecific Gravity of Cement
1/1000)
cum
= 2.45
ss of Chemical Admixture
cific Gravity of admixture
cum
c+d) ]
0.733 Cum
kgs
kgs
36.0
uld be Reduced by 6%
say 60
mix no.1
x (1/1000)
x (1/1000)
Kgs
x (1/1000)
x specific gravity of Coarse aggregate
gregate x
3 of 5
Similar Calculation are made for different trial mix as trial mix no. 1
materials Trial no.1 Trial no.2 Trial no.3 Trial no.4 Trial no.5
SSD DRY SSD DRY SSD DRY SSD DRY SSD DRY
Slump
45min
60min
compressive strength
4 of 5
A-11PROPOSED MIX PROPORTIONS WITH WATER
Cement 3
River sand 7
Water 1
Admixture 4
Density 2
Note: - Aggregates should be used in saturated s
allowance shall be made for the free (surface) mo
aggregates are dry, the amount of mixing water s
aggregates. necessary adjustments are also requ
absorption of aggregates shall be determined to IS
A-12 Compressive
Date 25/11/2018
1 8540 2.530
2 8550 2.533
3 8684 2.573
4 8656 2.565
5 8534 2.529
6 8658 2.565
Verified by
Quality Head
WATER CORRECTION FOR SITE
360 360
772 763
786 777
452 447
155 178
4.50 4.50
2529 2529
rated surface dry condition. If otherwise, when computing the r
ce) moisture contributed by the fine and coarse aggregates. O
water should be increased by an amount equal to the moisture
o required to be made in mass of aggregates. The surface wa
ed to IS: 2386.
essive strength of Concrete Cubes ( As per IS 516 )
Volume in CC
Area mm2
Load at
Strength Date of
Failure Average
(N/mm2) casting
(KN)
636.50 28.29
669.90 29.77
837.10 37.20
32.22 12/14/2018
765.80 34.04
786.70 34.96
653.60 29.05
For Becquerel
Mr. Jeevan G
Authorized sig
of ssd materials
Ratio by wt of
in Kg/cum
cement
0 1.00 1.00
3 2.14 2.12
7 2.18 2.16
7 1.26 1.24
8 0.43 0.49
50 0.01 0.01
29
en computing the requirement of mixing water,
rse aggregates. On the other hand, if the
ual to the moisture likely to be absorbed by the
es. The surface water and percent water
per IS 516 )
ume in CC 3375
Age in
Date of testing Remarks
days
12/21/2018 28
For Becquerel Industries Pvt. Ltd.
Authorized signatory
5 of 5