Академический Документы
Профессиональный Документы
Культура Документы
CHECKLIST
DATE: __________________
1
5 Layout Plan of the petrol station duly
signed by registered engineer
6 Building Permit
7 Construction Approval from EWURA
(applicable for Petrol Station
Constructed after April 2009)
8 Environmental Impact Assessment
(EIA) Certificate
9 Fire Safety Certificate from Fire &
Rescue Department
10 EWURA Receipt for Application Fee
b) No. of Nozzles
2
S/N Description Observation Remarks
e) Are the dispensing pumps in
good working condition?
f) Are the pumps calibrated by
WMA? When was the last
calibration?
g) Does the dispenser/pump
labelled?
3 Safety, Health & Environment
Safety
a) Does the petrol station has
clear and visible safety
warning signs (Switch off
Engine, Switch off mobile
phone, No smoking)
b) Does the pump island
protected with crush barriers
with height of 1m above the
ground?
c) Are the dispensers covered
with a canopy at least 3m
from the centre of the pump
island and 5m height
d) Is the petrol station equipped
with adequate and serviced
fire extinguishing equipment
including:
- Sand bucket for each pump
island?
- At least 2 x 9kg ABE
(powder type)
extinguishers located near
the dispensers or at least 1
extinguisher per pump
island?
e) Does petrol station allows
ease maneuverability,
accessibility (entrance/exit)
and no any hindrances such
parked vehicles etc?
f) Is an EMERGENCY SWITCH
properly installed, visible and
labelled?
g) Does petrol station conform
with minimum safety
distances requirements?
Health
h) Are the personnel provided
with protective clothing?
i) Are there clean and enough
toilet facilities for men and
women?
Environment
3
S/N Description Observation Remarks
j) Is the petrol station’s
forecourt paved with
impervious materials such as
concrete at least 4m around
the pump island?
k) Is the offloading area paved
with concrete at least 4m
around the area?
l) Is there a well-constructed
drainage system from the
paved areas to the oil/water
separator?
m) Is the oil-water separator
properly constructed with
three chambers? Each
chamber should have at least
minimum length of 1m, width
of 2m and depth of 1m.
n) Is the oil-water separator
having light removable cover
and gate valve installed at the
effluent pipe?
o) Does the petrol station have
good housekeeping? No
accumulation of combustible
materials such as wooden
pallets, tyres, cardboard,
papers, grass, overhanging
trees and above ground tanks
in the vicinity of the petrol
station.
p) Does the petrol station have
waste bins and good waste
handling management for
solid and liquid wastes
4
Licence?
b) Is the copy of the Licence
displayed?
c) Does petrol station
procure Petroleum
Products from only
licensed Wholesaler and
keep records of those
procurements?
d) Does petrol station have a
valid insurance cover to all
liabilities that may arise
from the conduct of the
Licensed Activity?
e) Does the petrol station has
customer service
standards to address its
clients concerns or
problem.
EWURA Representative(s)
Name
Signature
…………………………………
…………………………………
…………………………………
…………………………………
Name
Signature
5
…………………………………
…………………………………
…………………………………
…………………………………
NB:
NB: Fuel dispensing and offloading areas should be at least 8m from any source of