Section 61245003L7-5

Issue 1, April 1998


CLEI Code # T1L1B284AA
C A U T I O N !
PRACTICES SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.

MODEL DDM PLUS HTU-C


HIGH BIT-RATE DIGITAL SUBSCRIBER LINE
TRANSCEIVER UNIT - CENTRAL OFFICE
INSTALLATION/MAINTENANCE
CONTENTS
1. GENERAL .................................................................. 1
2. INSTALLATION ......................................................... 2
3. CONNECTIONS ........................................................ 4
4. HDSL SYSTEM TESTING ........................................ 4 HTU-C 7
1245003L
5. CONTROL PORT OPERATION ................................ 5
S

6. HDSL DEPLOYMENT GUIDELINES ...................... 12 T


A
T
U
S

7. TROUBLESHOOTING PROCEDURES .................. 13


8. MAINTENANCE ...................................................... 13 R
S
2
3
2

9. PRODUCT SPECIFICATIONS ................................ 13


10. WARRANTY AND CUSTOMER SERVICE ............ 13

N
3 4

O1
56
1 2
7

2 3 4 5
0

Appendix A. HDSL LOOPBACKS ............................... A-1


Appendix B. DS0 BLOCKING ..................................... B-1
Appendix C. SHELF CONFIGURATION ..................... C-1
Figure 1. ADTRAN DDM PLUS HTU-C
FIGURES
Figure 1. ADTRAN DDM Plus HTU-C ........................... 1 1. GENERAL
Figure 2. DDM Plus HTU-C Option Switch
Locations ........................................................ 3 The ADTRAN DDM Plus HTU-C, part number
Figure 3. HTU-C Edge Connector Wiring ..................... 4 1245003L7, is the central office (CO) unit used to
Figure 4. HTU-C Span Powering Diagram ................... 4 deploy a repeaterless T1 circuit using 4-wire metallic
Figure 5. HDSL Loopbacks ........................................... 5 facilities. The unit occupies one slot in an AT&T DDM
Figure 6. RS-232 (DB9) Pin Assignments .................... 5 Plus DS1 Extension shelf. The unit is illustrated in
Figure 7. Introductory Menu Screen ............................. 8 Figure 1.
Figure 8. HDSL Main Menu Screen .............................. 8
Figure 9. Current System Status Screen ...................... 9 DSX-1 signals are provided to and from the network
Figure 10. Performance History Screen ......................... 9
while 2B1Q HDSL signals are provided to the local
Figure 11. Loopback Options Screen ........................... 10
Figure 12. Self Test Options Screen ............................. 10
loop. The ADTRAN HTU-C works in conjunction with
Figure 13. Provisioning Screen ..................................... 11 the ADTRAN HTU-R and HRE to provide a DS1
Figure 14. Troubleshooting Display .............................. 11 service up to 24,000 feet on the local loop.
Figure 15. HDSL Deployment Guidelines ..................... 12
This HTU-C works with multiple list versions of the
HDSL unit remote end (HTU-R) and HDSL range
TABLES extender (HRE) as listed below:
Table A. Circuit Board Rotary Switch Option
Settings 1 ....................................................... 3 • 1242004L2, HTU-R T400 CP
Table B. SW2 Option Settings 2 .................................. 3 • 1242035L2, HTU-R SA
Table C. Front Panel Indicator ..................................... 3 • 1242031L2, HRE
Table D. Screen Abbreviations Defined ....................... 6
• 1244021L1, Low Voltage HTU-R T400 CP
Table E. HDSL Loss Values ....................................... 12
Table F. Loop Insertion Loss Data ............................. 12 • 1244022L1, Low Voltage HTU-R SA
Table G. Troubleshooting Guide ................................ 13 • 1244041LX, Low Voltage T400 HRE
Table H. HDSL DDM Plus HTU-C Unit • 1244042L1, Low Voltage 819A HRE
Specifications ............................................... 14 • 1244044L1, Low Voltage 439 HRE
Table A-1. HDSL Loopback Control Codes ................ A-1 • 1245021L1, Low Voltage HTU-R T200 CP
Table A-2. Inband Addressable Loopback Codes ...... A-2
• 1245022L1, Low Voltage HTU-R SA
• 1245026L1, Low Voltage HTU-R CI

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 1


The Low Voltage HTU-C can be deployed in circuits The DDM Plus HTU-C plugs directly into the AT&T
consisting of one HTU-C and one HTU-R. When DDM Plus shelf. The unit may be plugged into any of
deployment requires the HDSL Range Extender, the the 28 numbered slots in this shelf. No installation
Low Voltage HTU-C can be deployed with one Low wiring is required.
Voltage HRE (T400, 439, or 819A) and one Low Voltage
HTU-R. One eight-position rotary switch (SW1) and one five-
position Dipswitch pack (SW2) are used to configure
The HDSL local loop operates as two independent the mode of operation. Figure 2 shows the location of
subsystems each operating over a single twisted pair. these switches.
The HTU-C communicates over these two twisted
pairs to the HDSL Transceiver Unit Remote end A definition of each switch is shown in Tables A and B.
(HTU-R). Each subsystem carries half of the total Configuration may be performed by manually selecting
bandwidth along with a small amount of overhead each option switch, or alternatively, may be performed
used for maintenance and performance monitoring using the RS-232 craft access port.
related functions.
Faceplate Indicator
System power and alarm bus connections are made The HTU-C has one faceplate LED which indicates
through the backplane of the DDM Plus shelf. DSX-1 operational status. Table C defines this LED.
and HDSL signals are connected through the wire-wrap
pins related to each individual slot located on the rear Shelf Population (based on power requirements)
of the shelf. Typically the AT&T DDM Plus shelf is fused at 10 amps
per side (one half of the shelf). Appendix C contains
The HTU-C contains onboard fuses. If a fuse opens, a worksheet for calculating the maximum number of
it supplies a -48 VDC voltage to the fuse alarm bus and DDM PlusHTU-Cs allowed in the AT&T DDM Plus
all front panel indicators will be Off. These fuses are Shelf.
not designed to be field replaceable.
Several HTU-Cs can be mixed with other DDM Plus
The DDM Plus HTU-C uses a DC-to-DC converter to standard plug-ins, providing that the total current draw
derive its internal logic and span powering voltages per shelf side is less than or equal to 5 A. Refer to the
from the -48 VDC office supply. original equipment manufacturer's specifications for
more detail on specific power requirements of these
2. INSTALLATION units.
After unpacking the unit, immediately inspect it for
possible shipping damage. If damage is discovered,
file a claim immediately with the carrier, then contact
ADTRAN Customer Service (see subsection 10 of this
practice).
N
O1

B8ZS
FRM AMI
2 345

ESF UNFRM
3 4 SF
NIU LB
56
12

7 DIS EN
0
SW1 LBO EN
TMOUT
DIS SW2

Figure 2. DDM Plus HTU-C Option Switch Locations

Page 2 Section 61245.003L7-5, Issue 1 61245.003L7-5A


Table A. Circuit Board Rotary Switch Option Settings 1
(Default settings are indicated in bold typeface)
Switch Function Description

SW1 DSX-1 Line Build-Out .... This rotary switch is used to select operation of the line build-out equalizer in series with the
DSX-1 output.
0 ................................. Line length from 0-133 feet of ABAM cable
133 ................................. Line length from 133-266 feet of ABAM cable
266 ................................. Line length from 266-399 feet of ABAM cable
399 ................................. Line length from 399-533 feet of ABAM cable
533 ................................. Line length from 533-655 feet of ABAM cable

Table B. SW2 Option Settings 2


(Default settings are indicated in bold typeface.)

Function Description
Switch
Manual Code Select
SW2-1 ..... AMI ............................. Alternate Mark Inversion (AMI) is selected.
B8ZS .......................... B8ZS line code is selected.

T1 Framing
SW2-2 ..... Unframed ................... Selects Unframed (UFRM) operation; SW2-3 is ignored.
Framed ...................... Selects Framed operation.

Manual Frame Select


SW2-3 ..... SF ............................... Selects Superframe (SF) format.
ESF ............................ Selects Extended Superframe (ESF) format.

NIU Loopback ................. This switch programs the ADTRAN HDSL system to respond to traditional T1 network interface unit
SW2-4 ..... Enabled (NIU) loop-up and loop-down codes. See Appendix A for more information on specific codes.
Disabled

Loopback Timeout
SW2-5 ..... Enabled ...................... Loopback Timeout is Enabled.3, 4
Disabled ................... Loopback Timeout is Disabled.

HTU-C Table C. Front Panel Indicator


1245003L7
Indicator Description

STATUS ................ Blinking Red .......... Signal Quality of 0 or No Sync on at least one loop
S
T Solid Red ............... Alarm on any of HTU-C loops, HRE loops, DSX, or DS1 5
A Blinking Amber ...... Armed to accept inband loopbacks
T Solid Amber ........... Loopbacks active
U Blinking Green ....... ES, SES, or BPV occurred
S Solid Green ........... Everything functioning OK

R
S
2
3
2

1
The HTU-C transfers the local configuration to the HTU-R when circuit synchronization is achieved. The HTU-R then
sets its configuration to match the HTU-C.
2
The HTU-C transfers the local configuration to the HTU-R when circuit synchronization is achieved. The HTU-R then
sets its configuration to match the HTU-C.
3
Loopback timeout must be selected prior to initiating a loopback.
4
20-minute timeout is the default for Loopback Timeout Enabled. 60-minute and 120-minute timeouts are also
available from the craft interface.
5
The Status LED will be red if customer equipment is not installed. If this is the case, a BERT test or the craft interface
should be used to determine if HDSL loop synchronization has been achieved.

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 3


3. CONNECTIONS
T (101)
The DDM Plus HTU-C occupies one card slot in an LOOP 1
AT&T DDM Plus shelf. Power and alarm signals are R (102)
provided to the card through the backplane of the
shelf. DSX-1 and HDSL loop signals are connected to 2B1Q SPAN POWER
REGULATOR SPAN CURRENT
HDSL
the shelf connector and transmitted to the
corresponding slot the unit occupies. See Figure 3 for T1 (105)

HTU-C edge connection wiring. LOOP 2


R1 (106)
The HTU-C is capable of span powering the HTU-R by
applying simplex current to the local loop.
Approximately 100 mA of current is coupled onto the Figure 4. HTU-C Span Powering Diagram
HDSL span to power the HTU-R along with a Network Alarm Connections
Interface Unit or CSU that is located between the The following alarm signal is connected to the DDM
HTU-R and the customer. Loop 1 has the most Plus Alarm Module:
negative potential for span powering. The span
powering voltage is <-140 volts with Loop 1 providing Pin ............ 117
the negative voltage and Loop 2 the return (see Label ........ LOS and Fuse Alarm
Figure 4). Function ... Loss of signal and fuse alarm of -48 V supply

Alarm processing is actually performed by the DDM


Plus Alarm Module. Refer to the DDM Plus Alarm
100
101 LP1 TIP module documentation for further information.
LP1 RING
102
103 Alarm conditions are not reported at the DDM Plus
104
105 LP2 TIP
LP2 RING
HTU-C until the HDSL circuit is terminated by
106
107 TESTRX connecting an HTU-R. This allows circuit pack
TESTTX
108
DSX-1 RX TIP pre-provisioning. Once the HTU-C is terminated with
109
110
DSX-1 RX RING
an HTU-R, the unit will go into an in-service state.
111
112
113 4. HDSL SYSTEM TESTING
DSX-1 TX TIP
114
DSX-1 TX RING
115
116
The ADTRAN HDSL system provides extensive ability
117 ALARM (to Alarm Module)
-48V RETURN
to monitor the status and performance of the DSX-1
118
119 FRAME GROUND signals, DS1 signals, and HDSL loop signals. Detailed
200
201
performance monitoring is provided by the
202 faceplate-mounted RS-232 Control Port.
203
204
205 These features are valuable in troubleshooting and
206
207
isolating any system level problems that may occur at
208 installation or during operation of the HDSL system.
209 HDSL Loops 1 and 2 are dual duplex
210 loops--capable of simultaneously
211 transmitting and receiving data. HTU-C Loopbacks
212
213 The HTU-C responds to two different loopback
214 activation processes. First, loopback may be
215
216 commanded manually using the control port interface.
217 -48V
218
Figure 11 depicts the Loopback Options Screen which
219 provides for both HTU-C and HTU-R loopbacks.

Figure 3. HTU-C Edge Connector Wiring Secondly, the HTU-C responds to the industry defacto
standard for HDSL loopbacks, T1E1.4/92. A detailed
description of these loopback sequences is given in
Appendix A.

The loopback condition imposed in both cases is a


logic level loopback at the point within the HTU-C
where the DSX-1 signal passes into the HDSL
modulators. Figure 5 depicts all the loopback locations
possible with ADTRAN HDSL equipment.

Page 4 Section 61245.003L7-5, Issue 1 61245.003L7-5A


In addition to network-side loopbacks, the HTU-C
provides customer-side loopbacks initiated by using 1
6
the terminal control port. In this mode, an AIS signal 2 TXD (Transmit Data)
7
is supplied to the network. Customer-side loopbacks 3 RXD (Receive Data)
8
must be deactivated using the terminal. 4
9
5 SGN (Signal Ground)
When the 11000 in-band code is used to loop
the HTU-R, the HTU-R will re-enter armed
state upon loopback timeout, or upon terminal Figure 6. RS-232 (DB9) Pin Assignments
deactivation. See Appendix A for a more
detailed description of loopback element fixed at 8 data bits, no parity, and 1 stop bit. The
states. supported terminal type is VT 100 or compatible.

HTU-C Network Loopback Many portable personal computers use power-saving


programs that are known to interfere with applications
D running on the personal computer. If using a portable
LOCAL
DSX-1 DS1
LOOP personal computer with terminal emulation capability,
X
HTU-C HTU-R communication between the computer and the HDSL
unit may be periodically disrupted if power saving
programs are being used on the personal computer.
HTU-R Network Loopback
The symptoms may include misplaced characters
AIS appearing on the screen and/or the occurrence of
DSX-1 LOCAL
LOOP
DS1 screen timeouts. These symptoms are not disruptive
X to the operation of the circuit and are avoidable if the
HTU-C HTU-R
power saving options are disabled or removed.
HTU-R Customer Side Loopback
Operation
X For abbreviations used in the screen diagrams, see
LOCAL
DS1 Table D.
LOOP
D
HTU-C HTU-R The screens illustrated in Figures 7 through 14 are for
an HDSL circuit deployed with ADTRAN’s Low Voltage
NIU Loopback Feature of the HTU-R HDSL technology. The circuit includes an HTU-C,
HTU-R, and HRE. This scenario was chosen for
X inclusiveness of functionality. However, other
LOCAL
DSX-1 DS1
LOOP configurations are possible and their displays will vary
X
HTU-C HTU-R slightly from those shown in this section.

A terminal session is initiated by entering multiple


HTU-C Customer Side Loopback space bar characters, which are used by the HTU-C to
X
determine the speed of the terminal. Once the speed
LOCAL has been determined, an Introductory Menu is
LOOP DS1
AIS presented, as illustrated in Figure 7.
HTU-C HTU-R
From the Introductory Menu, the Main Menu may be
X = Signal Inactive
D = Data Sent selected. The Main Menu provides access to detailed
performance and configuration information, as
Figure 5. HDSL Loopbacks illustrated in Figure 8, HDSL Main Menu Screen.

5. CONTROL PORT OPERATION From the Main Menu, the following screens can be
accessed.
The HTU-C provides a faceplate-mounted DB9 connector
1. Current System Status
that supplies an RS-232 interface for connection to a
2. Performance History
controlling terminal. The pinout of the DB9 is illustrated 3. ADTRAN Information
in Figure 6. 4. Loopback Options
5. Self Test
The terminal interface operates at data rates from 1.2 6. Provisioning
kbps to 19.2 kbps. The asynchronous data format is 7. Troubleshooting

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 5


Table D. Screen Abbreviations Defined

Abbreviation Definition

ES ......................... Errored Seconds


DSX/DS1 .......... (SF) ....... Second in which a BPV or frame bit error occurs.
(ESF) ..... Second in which a BPV or CRC error occurs.
HDSL ................................ Second in which a CRC error occurs.

SES ....................... Severely Errored Seconds


DSX/DS1 .......... (SF) ....... Second in which 1544 BPVs or 8 frame bit errors occur.
(ESF) ..... Second in which 1544 BPVs or 320 CRC errors occur.
HDSL ................................ Second in which 165 CRC errors occur.

UAS ....................... Unavailable Seconds


DSX/DS1 .......................... Second in which there is a loss of signal or sync.
HDSL ................................ Second in which there is a loss of signal or sync.

SF ......................... Superframe Format

ESF ....................... Extended Superframe Format

B8ZS ..................... Binary 8 Zero Substitution

AMI ........................ Alternate Mark Inversion

LBO ....................... Line Build-Out

BPV ....................... Bipolar Violation


DSX/DS1 .......................... Second in which a bipolar violation occurs

NIU ........................ T1 Network Interface Unit

S/N ........................ Serial Number

15M ....................... Fifteen-Minute period

24H ....................... Twenty-Four-Hour period

The Current System Status screen illustrated in Figure By typing the letter “Z” at the Current System Status
9 provides quick access to status information for both screen, the current performance registers will be reset
the HTU-C and HTU-R. to zero on the Current System Status screen and
Performance History screen.
The Elapsed Time display indicates the period of time
since the unit began collecting performance LOSS ................. Pulse Attenuation Measurement *
information. At each 15-minute interval, the * LOSS is typically several dB less than the insertion loss
performance information is transferred to the 15-minute measured at 200 kHz. The LOSS measurement is a better
performance data register accessed from the indication of the loop’s attenuation of the 2B1Q signal than
Performance History screen. At each 24-hour interval, the insertion loss measured at a single frequency. Adtran
HDSL can operate on cables with an excess of 30 dB LOSS.
the performance data is transferred into the 24-hour
performance data register also accessed using the SYNC ................. HDSL Loop 1 and Loop 2 Sync Status
Performance History screen. The Performance History ES 15M/24H ...... Errored Seconds*
screen is shown in Figure 10. SES 15M/24H .... Severely Errored Seconds*
UAS 15M/24H .... Unavailable Seconds*

* The first number is for the current 15-minute period


and the second is the current 24-hour period (Loop 1
and Loop 2 numbers are displayed).

Page 6 Section 61245.003L7-5, Issue 1 61245.003L7-5A


An indication of Pair Reversal (if present) is given at The DS1 Output Level option in the
the bottom of the first key column. Status and Provisioning Screen of the HTU-C can only
configuration information for the DS1 and DSX-1 signals be altered if the circuit contains a 2nd or 4th
is located in the center of the screen near the bottom. generation HTU-R. (The generation of the
product is identified in the fourth digit of the
FRAME ....... T1 Framing Format selected
product number.)
CODE ......... T1 Line Code selected
LBO ............. Line Build-Out selected (for DSX-1); The Troubleshooting Display, illustrated in Figure 14,
Customer Signal of 0 or -15 dB (for graphically presents an HDSL circuit. The unit reviews
DS1) red, yellow, and blue alarm conditions in the circuit to
NIU .............. Network Interface Unit enabled? automatically predict where a fault is located. Once a
BPV ............. Bipolar Violations detected fault location is suspected, the corresponding portion
(DSX-1 and DS1) of the circuit on the screen is highlighted and a message
ES ............... Errored Seconds (DSX-1 and DS1) describing the failure is presented.
SES ............. Severely Errored Seconds (DSX-1 and
DS1)
UAS ............ Unavailable Seconds (DSX-1 and DS1)
Alarms ......... Lists current alarm condition status

A measure of signal quality for each HDSL loop is


displayed in graphic form on the bottom of the screen.
The measure is from 0 (poor signal quality) to 9
(excellent signal quality). Guidelines for interpreting
the indicators are given below.

0 ......... Noise margin is ≤ 0 dB (≈ 10-7 BER)


1-8 ...... Margin measurement above 10-7 BER in dB
9 ......... Margin is ≥ 9 dB (excellent quality) above 10-7
BER

The HDSL Loopback and Self-Test Option screens


are illustrated in Figures 11 and 12. Loopbacks and
Self-Test may be evoked or terminated using these
screens. A status of current loopback conditions is
also provided.

The Provisioning screen, illustrated in Figure 13, displays


current provisioning settings and allows for changing the
system configuration. Provisioning changes are only
allowed at the CO end of the circuit. Provisioning
changes made through this screen override the manual
switch settings. The unit retains the last provisioning
changes to determine its operating mode.

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 7


ADTRAN
901 Explorer Boulevard
Huntsville, Alabama 35806-2807

For Information or Technical Support,

Normal Support Hours ( 7am - 7pm CST ) or Emergency Support Hours ( 7x24 )
Voice Toll Free: 800.726.8663 Fax: 205.963.6217
Voice: 205.963.8100 Internet: www.adtran.com
———————————————————————————————————————----------------------------------------
HTU-C INFORMATION SIGNAL QUALITY HTU-R INFORMATION SIGNAL QUALITY
——————————---------- [X] 9 [X] ——————————---------- [X] 9 [X]
S/N : L[X] 8 L[X] S/N : L[X] 8 L[X]
CLEI: O[X] 7 O[X] CLEI: O[X] 7 O[X]
MANF: / O[X] 6 O[X] MANF: O[X] 6 O[X]
P[X] 5 P[X] P[X] 5 P[X]
HRE #1 INFORMATION [X] 4 [X] [X] 4 [X]
——————————---------- 1[X] 3 2[X] 1[X] 3 2[X]
S/N : [X] 2 [X] [X] 2 [X]
CLEI: [X] 1 [X] [X] 1 [X]
MANF: / [X] 0 [X] [X] 0 [X]
AT HTU-C AT HTU-R

Press “M” to view Main Menu.

Figure 7. Introductory Menu Screen

ADTRAN HDSL MAIN MENU

1) CURRENT SYSTEM STATUS


2) PERFORMANCE HISTORY
3) ADTRAN INFORMATION
4) LOOPBACK OPTIONS
5) SELF-TEST
6) PROVISIONING
7) TROUBLESHOOTING

Choose a screen by pressing the corresponding number._


_

Figure 8. HDSL Main Menu Screen

Page 8 Section 61245.003L7-5, Issue 1 61245.003L7-5A


HTU-C CURRENT SYSTEM STATUS HTU-R
LOOP #1 <NETWORK> LOOP #2 ELAPSED TIME 00:00:09 LOOP #1 <CUSTOMER> LOOP #2
------------------------- --------------------------
01 dB 01 dB <- LOSS -> 01 dB 01 dB
YES YES <- SYNC -> YES YES
000/00000 000/00000 <- ES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <- SES 15M/24H -> 000/00000 000/00000
000/00000 000/00000 <- UAS 15M/24H -> 000/00000 000/00000
LOOPBACKS INACTIVE LOOPBACKS INACTIVE

HTU-C SIGNAL QUALITY DSX-1 DS1 HTU-R SIGNAL QUALITY


[X] 9 [X] ----------------------------- [X] 9 [X]
L[X] 8 L[X] ESF <- FRAME -> ESF L[X] 8 L[X]
0[X] 7 0[X] B8ZS <- CODE -> B8ZS 0[X] 7 0[X]
0[X] 6 0[X] 0-133 <- LB0 -> 0 dB 0[X] 6 0[X]
P[X] 5 P[X] N/A <- NIU -> YES P[X] 5 P[X]
[X] 4 [X] 00000 <- BPV -> 00000 [X] 4 [X]
1[X] 3 2[X] 00000 <- ES -> 00000 1[X] 3 2[X]
[X] 2 [X] 00000 <- SES -> 00000 [X] 2 [X]
[X] 1 [X] 00000 <- UAS -> 00000 [X] 1 [X]
[X] 0 [X] NONE <- ALARMS -> NONE [X] 0 [X]
SEALING CURRENT PRESENT
Press “Z” to zero registers, “M” for Main Menu,
“H” for HDSL Range Extender #1 (HRE) View.

Figure 9. Current System Status Screen

PERFORMANCE HISTORY <VIEW 1 - HTU-C DSX-1 RECEIVER>


24 HOUR REGISTERS 15 MINUTE REGISTERS
---ES---SES-- --ES-SES----------ES-SES-
00000 00000 <---CURRENT---> 000 000
-1: ----- ----- <-- --> -1: 000 000 -17: 000 000
-2: ----- ----- | | -2: 000 000 -18: 000 000
-3: ----- ----- | | -3: 000 000 -19: 000 000
-4: ----- ----- | | -4: 000 000 -20: 000 000
-5: ----- ----- |PREVIOUS | -5: 000 000 -21: 000 000
-6: ----- ----- | | -6: 000 000 -22: 000 000
-7: ----- ----- <-- | -7: 000 000 -23: 000 000
| -8: 000 000 -24: 000 000
VIEW LOCATION DIAGRAM | -9: 000 000 -25: 000 000
| -10: 000 000 -26: 000 000
1->|H|<-3------|H|------4->|H|--> | -11: 000 000 -27: 000 000
|T| |R| |T| | -12: 000 000 -28: 000 000
|U| |E| |U| | -13: 000 000 -29: 000 000
<--|C|<-5------|1|------6->|R|<-2 | -14: 000 000 -30: 000 000
| -15: 000 000 -31: 000 000
--> -16: 000 000 -32: 000 000

Press view number to select view, “M” to return to Main Menu


Press “H” to view HRE #1 history

Figure 10. Performance History Screen

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 9


LOOPBACK OPTIONS

_____ _____ _____


|HTU-C| |HRE 1| |HTU-R|
| | | | | |
| | LP1 | | LP1 | |
--->|-----|<=========>| |<=========>|-----|<---
| | | | | |
NET| | | | | |CUST
| | LP2 | | LP2 | |
<---|-----|<=========>| |<=========>|-----|<---
| | | | | |
| | | | | |
|_____| |_____| |_____|

1) LOOPBACK TO NETWORK AT HTU-C = INACTIVE


2) LOOPBACK TO CUSTOMER AT HTU-C = INACTIVE
3) LOOPBACK TO NETWORK AT HTU-R = INACTIVE
4) LOOPBACK TO CUSTOMER AT HTU-R = INACTIVE
5) LOOPBACK TO NETWORK AT HRE1 = INACTIVE

Press corresponding number to toggle loopback option.


Press “M” for Main Menu.

Figure 11. Loopback Options Screen

SELF-TEST

Press “S” to initiate HTU-C and HTU-R self-tests._


_

Press “M” to return to the Main Menu.

Figure 12. Self Test Options Screen

Page 10 Section 61245.003L7-5, Issue 1 61245.003L7-5A


PROVISIONING
________________________________________________ ______________________
| | |
| PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS |
| ——————————————————---------------------——— | ————————--------- |
| 1. DSX-1 LINE BUILDOUT = 0-133 FEET | 0-133 FEET |
| 2. DSX-1/DS1 LINE CODE = B8ZS | B8ZS |
| 3. DSX-1/DS1 FRAMING = ESF | ESF |
| 4. NIU LOOPBACK = ENABLED | ENABLED |
| 5. LOOPBACK TIMEOUT = 20 MIN | 20 MIN |
| 6. DS1 TX LEVEL = 0 dB | |
| 7. DS0 BLOCKING | |
| | |
| 00000000 00000000 00000000 | |
| CHANNELS 1 24 | |
| “X” INDICATES A BLOCKED CHANNEL.| |
|________________________________________________|______________________|

Press: “n” — to change corresponding provision (ex. “3” for FRAMING)


“H” — to copy hardware settings to current settings
“I” — to implement and save current setting changes
“M” — to return to the main menu

Figure 13. Provisioning Screen

TROUBLESHOOTING DISPLAY

_____ _____ _____


|HTU-C| |HRE 1| |HTU-R|
| | | | | |
| | | | | |
--->|-----|<=========>| |<=========>|-----|<---
| | | | | |
NET| | | | | |CUST
| | | | | |
<---|-----|<=========>| |<=========>|-----|<---
| | | | | |
| | | | | |
|_____| |_____| |_____|

NO ALARM CONDITIONS

Press “M” for Main Menu.

Figure 14. Troubleshooting Display

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 11


12 Loop loss per Kft for other wire is summarized in
Table E.
11
WORKING LENGTH OF 24 GAUGE (OR COARSER) CABLE (KFT)

INVALID HDSL CABLE LENGTHS Table E. HDSL Loss Values


10 (200 kHz cable loss in dB/Kft at 135Ω)
___________________________________________
TOTAL
9 BRIDGED
2.5 Cable Cable Temperature:
TAP
8
2.0
1.5 LENGTH Gauge Type 68° 90° 120°
1.0 ___________________________________________
0.5 (KFT)
7 0.0
26 ............. PIC ........... 3.902 .... 4.051 ... 4.253
6 26 ............. Pulp .......... 4.030 .... 4.179 ... 4.381
24 ............. PIC ........... 2.863 .... 2.957 ... 3.083
5 24 ............. Pulp .......... 3.159 .... 3.257 ... 3.391
22 ............. PIC ........... 2.198 .... 2.255 ... 2.333
4 22 ............. Pulp .......... 2.483 .... 2.45 ..... 2.629
19 ............. PIC ........... 1.551 .... 1.587 ... 1.634
3 19 ............. Pulp .......... 1.817 .... 1.856 ... 1.909
___________________________________________
2
VALID HDSL CABLE LENGTHS Recommended maximum local loop loss information
1 for PIC cable at 70°F, 135Ω, resistive termination is
provided in Table F.
0
0 1 2 3 4 5 6 7 8 9 Table F. Loop Insertion Loss Data
WORKING LENGTH OF 26 GAUGE CABLE (KFT) __________________________________

Frequency (Hz) Maximum Loss (dB)


Figure 15. HDSL Deployment Guidelines __________________________________

3,000 ....................... 12.0


6. HDSL DEPLOYMENT GUIDELINES 10,000 ....................... 15.0
50,000 ....................... 25.5
The ADTRAN HDSL system is designed to provide 100,000 ....................... 30.0
DS1 based services over loops designed to comply 150,000 ...................... 32.75
with carrier service area (CSA) guidelines. CSA 200,000 ...................... 35.25
deployment guidelines are given below. __________________________________

1. All loops are non-loaded only. An approximation for the maximum amount of wideband
2. For loops with 26-AWG cable, the maximum loop noise on an HDSL local loop as measured by a 50 kbps
length including bridged tap lengths is 9 kft. filter is ≤ 31 dBrn.
3. For loops with 24-AWG cable, the maximum loop
length including bridged tap lengths is 12 kft.
An approximation for the maximum level of impulse
noise as measured using a 50 kbps filter on an HDSL
4. Any single bridged tap is limited to 2 kft.
loop is ≤ 50 dBrn.
5. Total bridged tap length is limited to 2.5 kft.
6. The total length of multi-gauge cable containing These approximations are to be used as
26-AWG cable must not exceed the following: guidelines only and may vary slightly on
12 - {(3*L26)/9} - LBTAP (in kft) different loops. Adhering to the guidelines
L26 = Total length of 26-AWG cable excluding
should produce performance in excess of
bridged taps (in kft) 10-7 BER.
BTAP
L = Total length of all bridged taps (in kft)

This deployment criteria is summarized in the chart


shown in Figure 15.

Page 12 Section 61245.003L7-5, Issue 1 61245.003L7-5A


7. TROUBLESHOOTING PROCEDURES 10. WARRANTY AND CUSTOMER SERVICE

Table G is a troubleshooting guide for the ADTRAN ADTRAN will replace or repair this product within ten
DDM Plus HTU-C. years from the date of shipment if it does not meet its
published specifications or fails while in service (see
8. MAINTENANCE ADTRAN Equipment Warranty, Repair, and Return
Policy and Procedure).
The ADTRAN DDM Plus HTU-C requires no routine
maintenance. In case of equipment malfunction, use Return Material Authorization (RMA) is required prior
the faceplate-mounted DB9 RS-232 terminal interface to returning equipment to ADTRAN.
to help in troubleshooting the source of the problem.
For service, RMA requests, or further information,
ADTRAN does not recommend that repairs be contact one of the following numbers:
performed in the field. Repair services may be obtained
by returning the defective unit to the ADTRAN Customer ADTRAN Customer Service:
Service RMA Department. ADTRAN Telco Technical Support . (800) 726-8663
Standard support hours ................... Monday-Friday
9. PRODUCT SPECIFICATIONS 7 a.m. - 7 p.m. CST
Emergency support ....... 7 days/week, 24 hours/day
Product specifications are detailed in Table H.
Sales ............................................... (800) 827-0807

Customer and Product Support ...... (256) 963-8722

Repair and Return Address:


ADTRAN, Inc.
Customer and Product Support (CAPS) Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807

Table G. Troubleshooting Guide

Condition Solution

Front panel indicator is off. 1. Verify that -48 VDC power is properly connected to the shelf.
2. Inspect the fuse (F1) and verify that it is not blown.
3. Insert the HTU-C into a slot known to be in good working condition, and verify
that the Status indicator is on.
4. If Steps 1 and 2 pass, but Step 3 fails, replace the HTU-C.

Status indicator is off. At least one loop has poor signal quality or loss of sync. Basic troubleshooting
procedures should identify a problem with a cable pair.

Status indicator is solid red. If customer equipment is no installed, implement an HTU-R to Network Loopback
and BERT test. If this test fails, or the craft interface indicates a loss of sync, there
is a problem with a cable pair that should be indentified through basic
troubleshooting procedures.

Status indicator is blinking green. Errors are being taken on either the DSX, DS1, or HDSL loops. The craft interface
will identify the source. BERT tests to the appropriate loopbacks should also
reveal the source of the problem.

61245.003L7-5A Section 61245.003L7-5, Issue 1 Page 13


Table H. HDSL DDM Plus HTU-C Unit Specifications
(Part Number 1245003L7)

Loop Interface

Modulation Type .................................... 2B1Q


Mode ...................................................... Full Duplex, Echo Cancelling
Number of Pairs ..................................... Two
Bit Rate .................................................. 784 kbps per pair
Baud Rate .............................................. 392K baud per pair
Service Range ....................................... Defined by Carrier Service Area Guidelines
Loop Loss .............................................. 36 dB maximum @ 200 kHz
Bridged Taps ......................................... Single Taps < 2000 feet, Total Taps < 2500 feet
Performance .......................................... Compliant with Bellcore TA-NWT-001210
HDSL Tx Signal Level ........................... 13.5 dBm
Input Impedance .................................... 135 Ω
Return Loss ........................................... 20 dB (40 kHz to 200 kHz)

Network Interface

4-WIRE DSX-1
DSX-1 Output Level .............................. 0 dB
DSX-1 Line Build Out ............................ 0-133 feet ABAM
134-266 feet ABAM
267-399 feet ABAM
400-533 feet ABAM
534-655 feet ABAM
DSX-1 Line Code ................................... AMI, B8ZS
DSX-1 Format ........................................ SF, ESF, Unframed
DSX-1 Channelization ........................... Channels 1-12 on Loop 1, Channels 13-24 on Loop 2

Power

HTU-C Power Dissipation ..................... 4.7 Watts without an HRE, 5.9 Watts with an HRE
HTU-C -42.5 VDC Current Drain .......... .19 Amps without an HRE, .40 Amps with an HRE
Span Power ........................................... <-140 VDC (Internally Generated) current limited at 250 mA
Fusing .................................................... 1.00 A

Clock

Clock Sources ....................................... Internal, DSX-1 Derived


Internal Clock Accuracy ........................ ± 25 ppm, (exceeds Stratum 4). Meets T1.101 timing requirements.

Tests

Diagnostics ............................................ Self-Test, Local Loopback (HTU-C), Remote Loopback (HTU-R)

Physical

23" DDM Plus Shelf-Mounted


Dimensions ............................................ 3.51" High, .71" Wide, 9.89" Deep
Weight .................................................... Less than 1 lb.

Environment

Temperature .......................................... Operating (Standard): -40°C to +70°C; Storage: -40°C to +85°C

Control Port

Interface ................................................. RS-232 (DB9)


Terminal Type ........................................ VT 100 or compatible
Async Speed ......................................... 2.4 kbps to 19.2 kbps
Data Format ........................................... 8 data bits, no parity, 1 stop bit

Page 14 Section 61245.003L7-5, Issue 1 61245.003L7-5A


Appendix A
HDSL LOOPBACKS
HDSL MAINTENANCE MODES The unframed method produces periodic control
sequences and the normal DS1 framing bit is omitted.
This appendix describes operation of the HDSL system
with regard to detection of in-band and ESF facility The overwrite method produces periodic control
data link loopback codes. sequences. However, once per frame, the framing bit
overwrites one of the bits in the control sequence.
Upon deactivation of a loopback, the HDSL system
will synchronize automatically. Note that the The unit can detect the loopback activation or
synchronization process of the HDSL system upon deactivation code sequence only if an error rate of
deactivation of the HRE loopback could take up to 15 1E-03 or better is present.
seconds, ensuring all system elements are
synchronized. Loopback Control Codes
A summary of control sequences is given in Tables
Loopback Process Description A-1 and A-2.
In general, the loopback process for the HDSL system
elements is modeled on the corresponding DS1 system In all control code sequences presented, the
process. Specifically, the HTU-C loopback is similar in-band codes are shown left-most bit
to an Intelligent Office Repeater loopback and the transmitted first, and the ESF data link codes
HTU-R loopbacks are similar to an inline T1 Repeater with right-most bit transmitted first.
loopback.

In-band control code sequences are transmitted over


the DS1 link by either the unframed or overwrite
method. The HDSL elements respond to either
method.

Table A-1. HDSL Loopback Control Codes


Type Source Code Name

Abbreviated (N) ................. 3in7 (1110000) .............. Loopback data from network toward network in the HTU-R.
(N) ................. 4in7 (1111000) .............. Loopback data from network toward network in the HTU-C.
(N) ................. 2in6 (110000) ................ Loopback data from network toward network in first HRE.
(C) ................. 6in7 (1111110) .............. Loopback data from customer toward customer in HTU-C.
(C) ................. 5in7 (1111100) .............. Loopback data from customer toward customer in HTU-R.
(C) ................. 4in6 (111100) ................ Loopback data from customer toward customer in first HRE.

Wescom (N) ................. FF1E .............................. Loopback data from network toward network at HTU-C.
(C) ................. 3F1E .............................. Loopback data from customer toward customer at HTU-C.
(N) ................. FF04 .............................. Loopback data from network toward network at HRE1.
(C) ................. 3F04 .............................. Loopback data from customer toward customer at HRE1.
(N) ................. FF02 .............................. Loopback data from network toward network at HTU-R.
(C) ................. 3F02 .............................. Loopback data from customer toward customer at HTU-R.
(C) ................. FF48 (ESF-DL) .............. Loopback data from customer toward customer at HTU-R.
(N) ................. 1in6 (100000) ................ Loopback data from network toward network at HTU-R.
(N) ................. FF48 (ESF-DL) .............. Loopback data from network toward network at HTU-R.
(N/C) ............. 1in3 (100) ...................... Loopdown everything.
(N/C) ............. FF24 (ESF-DL) .............. Loopdown everything.

Notes: The Source column indicates which side of the interface the control codes are sent from. For example, an (N) indicates a network
sourced code while a (C) indicates a customer sourced code.
All codes are inband unless labeled ESF-DL
All codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.

61245.003L7-5A Section 61245003L7-5, Issue 1 A-1


Table A-2. Inband Addressable Loopback Codes

Function Code Response

ARM ............................................................... 11000 NIU LOOPBACK ENABLED: The HTU-R will loopup towards the
(also known network. No AIS or errors will be sent as a result of this loopback. The
as a 2-in-5 HTU-C and HRE will ARM.
pattern)

DISARM ......................................................... 11100 The HTU-C and HRE are removed from the armed state. If any of the
(also known units are in loopback when the 11100 pattern is received, they will
as a 3-in-5 loopdown. The LBK LEDs will turn off on all units.
pattern)

HTU-C NETWORK LOOPUP ........................ D3D3 If the units have been armed and no units are in loopback*, the HTU-C
(1101 0011 will loopup towards the network, 2 seconds of AIS (all 1s) will be sent, 5
1101 0011) seconds of data will pass, and then 231 bit errors will be injected into the
DSX-1 signal. As long as the pattern continues to be sent, 231 errors will
be injected every 20 seconds. When the pattern is removed, the unit will
remain in loopback. If the pattern is reinstated, the injection of 231 bit
errors will resume at 20 second intervals.

HRE NETWORK LOOPUP ........................... C741 If an HRE is present, the units have been armed, the HRE will loopup
(1100 0111 towards the network, 2 seconds of AIS (all 1s) will be sent, 5 seconds of
0100 0001) data will pass, and then 10 bit errors will be injected into the DSX-1
signal. As long as the pattern continues to be sent, 10 errors will be
injected every 20 seconds. When the pattern is removed, the unit will
remain in loopback. If the pattern is reinstated, the injection of 10 bit
errors will resume at 20 second intervals.

LOOPDOWN ................................................. 9393 Any HTU-C and HRE units currently in loopback towards the network will
(1001 0011 loopdown and will not attain the armed state.
1001 0011)

QUERY LOOPBACK ..................................... D5D5 If the units are armed and the HTU-C, HRE, or HTU-R are in network
(1101 0101 loopback, errors are injected into the DSX-1 signal upon detection of the
1101 0101) query loopback pattern. As long as the pattern continues to be sent,
errors are injected again every 20 seconds. The number of errors
injected each time depends on which unit is in loopback. 231 errors are
injected if the HTU-C is in network loopback, 20 at a time if the HTU-R
is in network loopback, and 10 at a time if the HRE is in network loopback.

LOOPBACK TIMEOUT OVERRIDE ............. D5D6 If the units are armed and this pattern is sent, the loopback timeout will
(1101 0101 be disabled. The timeout option will be updated on the PROVISIONING
1101 0110) menu of the HTU-R (viewable through the RS-232 port) to NONE. As
long as the units remain armed, the timeout will remain disabled. When
the units are disarmed, the loopback timeout will return to the value it had
before the D5D6 code was sent.

SPAN POWER DISABLE .............................. 6767 If the units are armed and this pattern is sent, the HTU-C will deactivate
(0110 0111 its span power supply, turning off the HTU-R and HRE (if present). As
0110 0111) long as the pattern continues to be sent, the span power supply will
remain disabled. When the pattern is no longer being sent, the HTU-C
will reactivate its span power supply, turning the remote unit(s) on. All
units will retrain and return to the disarmed and unlooped state.

Note: all codes listed above must be sent for a minimum of 5 seconds in order for them to be detected and acted upon.
* If NIU is enabled, then the HTU-R can be in network loopback when the HTU-C or HRE loopup codes are sent.

A-2 Section 61245003L7-5, Issue 1 61245.003L7-5A


Appendix B
DS0 BLOCKING

ADTRAN has implemented the DS0 blocking feature The result of this blocking is that the CRC checksum
enabling the HDSL system to remain transparent to delivered to the remote end will not match the checksum
customer data. This allows ADTRAN products to calculated by the remote T1 CSU. This implies errors
comply with the transparency requirements of Bellcore are being made on the loop when actually the blocking
TA-NWT-001210. However, when the circuit is function created the CRC errors. Enabled DS0 channels
provisioned for ESF operation, this transparency results pass error-free.
in a condition described below.
In order to avoid this condition, Fractional T1 customers
If a customer of a Fractional T1 service fills any of the are encouraged to fill the unused timeslots with an idle
unused DS0 channels with information other than an code. This is a common capability on Fractional T1
all 1s idle code, the ADTRAN HDSL system will block CSU/DSU, D4 channel banks, and other CPE devices
this information from reaching the remote end of the capable of connecting to Fractional T1 service.
circuit. This forces information in those DS0 channels
to be an all 1s idle code.

61245.004L7-5A Section 61245004L7-5, Issue 1 B-1


Appendix C
SHELF CONFIGURATION

DDM Plus Shelf Population (Power Requirements)

1. Determine shelf fusing (A). ............................................................................................ _____ Amps


Typically: 20 Amp for DDM Plus shelf (10 amp per side)

2. Divide (A) by 2 to provide 100% over current protection (B). ....................................... _____ Amps

3. Determine the mix of HDSL circuits.


Percentage of circuits without an HRE in the circuit (C) ........................................ _____ Percent
Percentage of circuits with an HRE in the circuit (D) ............................................. _____ Percent

4. Determine current draw of HDSL circuits.


Multiply (C) by .19 Amps (without an HRE) (E) ...................................................... _____ Amps/Unit
Multiply (D) by .40 Amps (with an HRE) (F) ........................................................... _____ Amps/Unit

5. Add (E) and (F) to get total current draw (G) ................................................................ _____ Amps/Unit

6. Divide (B) by (G) to get the number of Units per shelf .................................................. _____ Units/Shelf *

* DDM Plus Shelf is physically limited to only 28 units per shelf.