Вы находитесь на странице: 1из 12

SYSTEM CABLES

PRODUCT BROCHURE
2 www. MESCcables.com

Introduction
MESC is considered the leading Cables, Railway Signaling and power
manufacturer and supplier of all types cables and any types of customized
of cables to EPC contractor for mega cables manufactured as per the
projects in the Middle East and North customers’ needs and specifications.
Africa.
MESC offers the following types
Middle East Specialized Cable Co. of cables:
(MESC) was founded as a privately
owned in Riyadh in 1993 to cater the • Instrumentation & Data
growing industry of specialized cables in • Thermocouple Extension
the region. Started rolling its machines • Fire Resistance
in 1994 and selling in 1995. After • Control
consolidating its presence in KSA as • LAN/Computer/Nurse Call/HVAC/
the market leader, MESC succeeded in BMS/Audio
penetrating other markets in GCC, Middle • Telephone (Filled/Unfilled/VRB/
East, North Africa, Europe and USA. In Pilot)
2007 it became a joint stock company • Coaxial
and its shares floated on Saudi Stock
• Power
market.
• Fire Alarm
Over the years, MESC has expanded • NYMHY/NYLHY
its production to cover all types and • FLEX/NYAF/SIS/NYZ
ranges of cables by acquiring existing • THHN/THWN/TFFN/XHHW/THW
companies, establishing new companies • NYA/THWN/Cu-XLPE/Irrigation
and joint ventures. Its products range • LV & Control
includes the Industrial, Instrumentation
• Miscellaneous (ABC, ATC, HDBC)
and process Control Cables, Special
Cables (BMS), Low Voltage Power cables,
Medium Voltage Power cables, Offshore
System cables | CATALOGUE 2018 3

Our Clients
4 www. MESCcables.com

CAT 5e UTP
TIA/EIA 568-A-5

CABLE CODE: M662-04P24AWG-U0GY8-00


FOR LSHF CODE: M662-04P24AWG-U0GY8-H0
APPLICATIONS: This cable is
intended to be used for data
CHARACTERISTICS
transmission rate of up to 150 Mb/s
Frequency 1 – 100 MHz
CONSTRUCTION
Impedance 100+/‑ 15 Ω
Conductor 8, twisted in 4 pairs, 24 AWG Solid annealed
Direct cur conductor resistance 93.8 Ω/km
Insulation Polyethylene
Nominal capacitance 46 pF/m
Color code White/blue+blue, white/orange+orange, white/green+green, white/
Halogen acid gas (for LSHF only) ≤0.5% (IEC 60754‑1) (outer sheath)
brown+brown
Limiting Oxygen index (for LSHF only): ≥ 30 ASTM D2863 (outer sheath)
Pair assembly Twisted pairs assembled

Outer jacket Grey color PVC jacket (LSHF outer sheath material can also supplied) Cable overall diameter 5.3 mm

PRINTING TEXT (EXAMPLE):


MESC LAN CAT5e 4PX24AWG UTP
System cables | CATALOGUE 2018 5

LAN CAT 6 UTP


TIA/EIA 568-C.2 & UL 444

APPLICATIONS: This cables are


intended to be used for low loss CABLE CODE: MA62-04P23AWG-U0GYM-00
extended frequency data systems
that operate up to 250 MHz, Suitable
for building structured cabling CHARACTERISTICS
supports IP-based security and
building automation systems. Frequency 1 - 250 MHz

Impedance 100+/- 15 Ω
CONSTRUCTION
Flame Retardance IEC 60332-1
Conductor 8, twisted in 4 pairs, 23 AWG solid copper
Halogen acid gas ≤ 17% IEC 60754-1(outer sheath)
Insulation Polyethylene insulated Halogen acid gas (for LSHF only) ≤0.5% (IEC 60754‑1) (outer sheath)
Pair assembly Twisted pairs assembled with a center separator Limiting Oxygen index ≥ 30 ASTM D 2863 (outer sheath)
Outer jacket PVC with Grey color jacket
Operating temperature –20 to +60 ºC
White/blue+blue, white/orange+orange, white/green+green,
Color code Cable overall diameter 6.5 mm
зwhite/brown+brown

PRINTING TEXT (EXAMPLE):


MESC LAN CAT6 4PX23AWG UTP
6 www. MESCcables.com

CAT 6A, Twisted Pair, S/FTP, LSHF


TIA/EIA 568-C.2

APPLICATIONS: Suitable for


enterprise applications designed
to deliver robust standards based
performance ensuring optimum
bandwidth for today’s high speed
network applications. The cable CABLE CODE: MD63-04P23AWG-U2GYM-H0
is designed to support horizontal
networking applications over
CHARACTERISTICS
distances up to 100 meters,
10GBASE-T Ethernet. Fully compliant Frequency 1 – 500 MHz
to Category 6A requirements,
including alien crosstalk (AXT). Impedance 100+/- 15 Ω

Mutual Capacitance ≤ 56 nF/km


CONSTRUCTION
Direct cur conductor resistance 72.0 Ω/km
Conductor 8, twisted in 4 pairs, 23AWG solid annealed copper
Min.insulation resistance >2GΩ•km
Insulation Foam polyethylene
Propagation velocity 74 %
Pair shield Each pair is shielded with an aluminum polyester tape
Halogen acid gas ≤0.5% IEC 60754-1(outer sheath)
Assembly Shielded twisted pairs are assembled with a solid tinned copper drain and
braided with tinned copper wires Limiting Oxygen index ≥ 30 ASTM D2863 (outer sheath)

Outer jacket Flame retardant LSHF with color Grey Operating temperature -20 to 70 ºC

Color code White/Blue, White/Orange, White/Green, White/Brown Cable overall diameter 8.7 mm

PRINTING TEXT (EXAMPLE):


MESC CAT 6A 4PX23AWG LSHF EIA/TIA 568-C.2
System cables | CATALOGUE 2018 7

Frequency MHz Attenuation, dB/100m 20 °C PS NEXT Loss, dB NEXT Loss, dB RL, dB (ELFEXT), dB PS (ELFEXT), dB

4 3.8 65.3 63.3 23.0 55.8 52.8


10 5.9 59.3 57.3 25.0 47.8 44.8
16 7.5 56.2 54.2 25.0 43.7 40.7
20 8.4 54.8 52.8 25.0 41.8 38.8
31.25 10.5 51.9 49.9 23.6 37.9 34.9
62.5 15.0 47.4 45.4 21.5 31.9 28.9
100 19.1 44.3 42.3 20.1 27.8 24.8
200 27.6 39.8 37.8 18.0 21.8 18.8
250 31.1 38.3 36.3 17.3 19.8 16.8
500 45.3 33.8 31.8 15.2 13.8 10.8
8 www. MESCcables.com

FIRE ALARM SYSTEMS BUILDING MANAGEMENT SYSTEM


FIRE ALARM CABLES (SHIELDED & UNSHIELDED) 105 °C (UL 1424) INSTRUMENTATION / PROCESS CONTROL CABLES
POWER LIMITED FIRE PROTECTIVE SIGNALLING CIRCUIT CABLES 300 V (TYPE PLTC 300 VOLTS)
PVC INSULATED SINGLE PAIR / TRIAD OVERALL SHIELDED

STANDARD

UL 13
TEMPERATURE RANGE :
- 40 °C to +90 °C
APPLICATIONS: Can be used in
cable tray, conduit or direct burial
application for instrumentation /
APPLICATIONS: Can be used as process control, in dry or wet location.
a fixed wiring within buildings in
accordance with NEC Article 760
Power limited circuits. Also suitable CONSTRUCTION
as a power limited circuit cable in
accordance with NEC Article 725 Conductor Plain copper to ASTM B3 , stranded to class B of ASTM B8.
class 2 or 3 circuits.
Insulation Flame retardant PVC insulation rated 90° C as per UL13.

CONSTRUCTION Pair Colour


White and Black.
Code
Conductor Solid Annealed Copper Conductor as per ASTM B3. Triple Colour
White, Black and Red.
Code
Insulation Extruded Solid PVC rated 105 °C.
Overall Twisted pair / triple is shielded with aluminum polyester tape and a tinned
Colour coded insulated cores cabled. When the assembly is shielded an Shielding copper drain wire.
Assembly Aluminium Mylar Tape is used with a stranded tinned copper drain wire in
Extruded black PVC as per UL13, oil and sunlight resistant, passes flame
contact with Aluminium part of the screen.
Jacket test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and
Outer jacket Red Coloured PVC jacked passes the IEEE-383 Flame Test. moisture penetration.

PRINTING TEXT (EXAMPLE): PRINTING TEXT (EXAMPLE):


FIRE ALARM CABLE (UL) FPLR MESC 2014 INSTRUMENTATIONTYPE PLTC (UL) 300 V MESC 2016
System cables | CATALOGUE 2018 9

PUBLIC ADDRESS SYSTEMS INTERCOM SYSTEMS SECURITY SYSTEMS


SPEAKER CABLES AUDIO CABLES EI RS-485 APPLICATIONS

14 AWG (19 X 27) 22AWG (7 X 30), 18 AWG (16 X 30) 22 AWG (7 X 30)

Stranded tinned copper, PVC Stranded tinned copper, PVC Stranded tinned copper, foam
insulated, twisted pair, overall Description insulated, twisted pair, Grey PVC polyethylene insulated, twisted pairs
Description aluminum polyster shield, 16 AWG jacket. overall aluminum polyester shield, 22
Description
stranded tinned copper drain wire, AWG stranded tinned copper drain
Grey PVC jacket. Color code Red, Black. wire, overall tinned copper braid
shield (90% coverage).
Color code Black & White.
Color code Black PVC jacket

PRINTING TEXT (EXAMPLE): PRINTING TEXT (EXAMPLE): PRINTING TEXT (EXAMPLE):


TYPE CM (UL) MESC 2016 TYPE CM (UL) MESC 2016 TYPE CM (RS-485) MESC 2014
10 www. MESCcables.com

CAT 7, Twisted Pair, S/FTP, LSHF


ISO / IEC 11801 requirements

APPLICATIONS: Suitable for


enterprise applications designed
to deliver robust standards based
performance ensuring optimum
bandwidth for today’s high speed CABLE CODE: MB63-04P23AWG-U2GYM-H0
network applications support all
CLASS EA applications such as .POTS/
CATV, 10GBASE-T, 4G FCBASE-T CHARACTERISTICS
and 1000BASE-T (Gigabit Ethernet)
over single cable. Fully compliant to Frequency 1 – 600 MHz
Category 7 requirements, including
alien crosstalk (AXT). Impedance 100+/- 15 Ω

Direct cur conductor resistance 72.0 Ω/km


CONSTRUCTION
Min.insulation resistance >2GΩ•km
Conductor 8, twisted in 4 pairs, 23 AWG Solid annealed copper

Insulation Foam polyethylene Propagation velocity 74 %

Pair shield Each pair is shielded with an Aluminum polyester tape Halogen acid gas ≤0.5% (IEC 60754-1)(outer sheath)

Shielded twisted pairs are assembled with a solid tinned Copper drain & Limiting Oxygen index ≥ 30 ASTM D2863 (outer sheath)
Assembly
Braided with tinned copper wires
Operating temperature -20 to 70 ºC
Outer jacket Flame retardant LSHF with color Grey

Color code White/Blue, White/Orange, White/Green, White/Brown Cable overall diameter 8.7 mm

PRINTING TEXT (EXAMPLE):


MESC CAT 7 S/FTP 4PX23AWG LSHF ISO IEC 11801
System cables | CATALOGUE 2018 11

Frequency MHz Attenuation, dB/100m 20 °C PS NEXT Loss, dB NEXT Loss, dB RL, dB (ELFEXT), dB PS (ELFEXT), dB

4 3.7 80.0 77.0 75.0 73.3 23


10 5.9 80.0 77.0 71.0 71.1 25
16 7.4 80.0 77.0 66.9 69.6 25
20 8.3 80.0 77.0 65.0 68.7 25
31.2 10.4 80.0 77.0 61.1 66.6 23.7
62.5 14.9 75.5 72.5 55.1 57.6 21.5
100 19.0 72.4 69.4 51.0 50.4 20.1
155 24.0 69.5 66.5 47.2 42.6 18.8
250 31.0 66.4 63.4 43.0 32.5 17.3
600 50.1 60.7 57.7 35.4 7.6 17.3

Contacts
CORPORATE AND SALES OFFICE JEDDAH OFFICE
Salah Uddin Street Jeddah – Sari Street
Al Bait Building 1- Floor 1 & 3 Sari Gate 1floor – Near Jarir Store Dammam
P.O Box 60536, Riyadh 11555 P.O.Box 122048, Jeddah 21332
KSA KSA
Dubai
Tel: +966 11-476-7373 Tel: +966 12 606 8044 Riyadh
Fax: +966 11 472-3192 Fax: +966 12 606 8011
general@MESCcables.com general@MESCcables.com

DAMMAM BRANCH DUBAI REGIONAL OFFICE


King Abdulaziz St. Al Hawai Tower, 101 Shaikh Zayed
Electricity World Building Flor # 2 Road Jeddah
P.O Box 32257, Khobar 31952 P.O. Box 73750, Dubai, UAE
Saudi Arabia Tel.: +971 4 343 7885
Tel: +966 13 833 4474 Fax: +971 4 343 7488
Fax:  +966 13 832 2605 dubai.sales@MESCcables.com​
general@MESCcables.com
SYSTEM CABLES
PRODUCT BROCHURE
SALAH UDDIN STREET
Al Bait Building 1- Floor 1 & 3 P.O
Box 60536, Riyadh 11555 KSA
Tel: +966 11-476-7373
Fax: +966 11-476-0712
General@MESCcables.com
Br2017Dec-E

www. MESCcables.com

Вам также может понравиться