durabond GP

Single-pack acrylic emulsion, bonding and curing agent

DESCRIPTION 1. Priming/bonding agent: ± 7 m²/litre


TYPICAL PHYSICAL PROPERTIES 2. Curing compound: ± 5 m²/litre
durabond GP is a modified, single-
Liquid acrylic Note: Wastage and irregular surface
pack acrylic emulsion which is milky in Type
emulsion profiles will reduce the practical
colour.
Colour Milky coverage rates.
USES
Minimum film APPLICATION
• As a primer/bonding medium for forming o
+ 11 C
cementitious repairs to concrete temperature For priming/bonding
elements in both internal and (MFT) The prepared surface is to be
external applications. thoroughly saturated using clean water
Typical solids
• Typically used with durarep GT, + 47% prior to applying durabond GP. The
content
HS, FR and FS range of repair surface saturation is generally carried
systems where normal or high Average density 1,060 out 1 to 2 hours before application but
build applications are required in may require more depending on the
vertical, horizontal or overhead pH value + 10 substrate porosity, temperature and
locations. wind conditions. All excess free water
Solvent resistance Not Resistant
• durabond GP is an excellent must be removed. A saturated surface
curing compound for repairs Very High ensures ease of product spread and
carried out in both internal and (do not use in application, and reduces suction
external applications. Water resistance permanent caused by porous substrates resulting
• durabond GP is not suitable for immersion in good bonding properties.
repairs that will be subjected to applications)
continuous immersed conditions. durabond GP is applied to the
Freeze/thaw surface, at the recommended
• For structural bonding, where cycles
Not stable
the bond strength is to be equal application rate, using a stiff-bristle
or greater than the tensile brush ensuring that the total area of
strength of the parent concrete, SURFACE PREPARATION repair is thoroughly coated. Care
use epidermix 344 or 345. should be taken not to apply excessive
The substrate must be clean, sound, amounts i.e. pooling and ponding must
and free of any oil, grease, loose be avoided as this could result in the
FEATURES & BENEFITS repair mortar 'hogging' or slipping on
particles, cement laitance and other
contaminants. Should compressed air the surface, resulting in cracking and
• Ease of application, single or poor adhesion.
component product with a long be employed, ensure that the air is
Immediately apply the repair mortar
open time. clean and oil free.
while the primed surface is still tacky
• Resistant to hydrolysis – alkali and finish off accordingly.
stable. All edges to be repaired must be
Should the durabond GP surface dry,
• Economical. square-cut to a minimum of 10 mm
then a second bond coat must be
• Suitable for internal & external deep, perpendicular to the surface,
applied to receive the repair mortar.
applications. followed by the removal of all unsound
Drying may occur in 3 to 4 hours at
• One product - used as a bonding material to a minimum depth as o
25 C but may vary subject to wind
agent and curing compound. prescribed in the product selected for
conditions.
• Bond strengths between repair the repair. A sound exposed aggregate
mortar and concrete are surface is recommended. Never
For curing the repair mortar
excellent. feather edge the repair products.
durabond GP is applied by brush to
• Excellent curing properties. The substrate must be well dampened, the entire repaired area at the
• Compatible with our duracote with no free water on the surface prior recommended coverage rate for
range of protective coatings. to applying durabond GP. optimum performance. The application
• Non-toxic. must commence as soon as the
COVERAGE surface will not be marred by brushing
and have an unbroken film to provide a
durabond GP applied as high curing efficiency.

Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384
Note: For bonding and curing,
durabond GP must be applied neat HEALTH & SAFETY
and must not be diluted. All equipment,
paint trays or containers, must be Cured or wet durabond GP is non-
clean. toxic, non-flammable and slightly
alkaline. Always wear gloves, eyewear
CLEANING and protective clothing when working
with the material and avoid excessive
Clean tools and equipment with water inhalation, ingestion and skin contact.
before the material hardens. If material is splashed in the eye, wash
with of clean water and seek medical
PROTECTION ON COMPLETION attention.

In rapid drying conditions caused by IMPORTANT NOTE


high winds or direct sunlight additional
precautions should be included, like This data sheet is issued as a guide to
sealing with polythene sheeting having the use of the product(s) concerned.
the edges taped down. This may Whilst abe Construction Chemicals
include damp hessian behind the endeavours to ensure that any advice,
sheeting to prevent moisture loss. recommendation, specification or
Similarly in cold conditions, the information is accurate and correct, the
repaired area must be protected from company cannot - because abe has no
freezing. direct or continuous control over where
For additional protection properties, and how abe products are applied -
durabond GP is fully compatible with accept any liability either directly or
the duracote range of protective indirectly arising from the use of abe
coatings and may be overcoated as products, whether or not in accordance
required. with any advice, specification,
recommendation, or information given
TEMPERATURE AND RELATIVE by the company.
HUMIDITY
FURTHER INFORMATION
Surface and ambient temperature
must be at least + 5° C and growing, Where other products are to be used
o o
ideally between 20 C and 30 C. in conjunction with this material, the
relevant technical data sheets should
be consulted to determine total
MODEL SPECIFICATION FOR
requirements. abe Construction
durabond GP Chemicals has a wealth of technical
and practical experience built up over
Acrylic bonding/curing agent for years in the company’s pursuit of
use with durarep repair mortars. excellence in building and construction
The bonding agent will be durabond technology.
GP, an acrylic bonding and curing
agent and will be applied in
accordance with the recommendations
of abe Construction Chemicals.

PACKAGING

durabond GP is supplied in 5 litre and


25 litre yield plastic containers.

HANDLING & STORAGE

This product has a shelf life of


12 months if kept in a dry cool place in
the original packaging. In more
extreme conditions this period might
be shortened.
durabond GP must be protected from
freezing during storage. Product which
has been allowed to freeze at any
stage must be discarded.
Revision 9203

Karachi: Room No.1, Mezzanine Floor, Al-Hayat Chambers, A-7, Block-7/8, K.C.H.S. Tel: +92 21 4535898-99, Fax: +92 21 4558071
Lahore: 25-A, FCC, Syed Maratib Ali Road, Gulberg 4, Tel: +92 42 5763360 Fax: +92 42 5875384

Вам также может понравиться