Вы находитесь на странице: 1из 5

Semua  menggunakan  baja  BJ37  (Fy=240Mpa  Fu=370Mpa  E 

=2.105Mpa    G=8.104Mpa).  Perhitungan  menggunakan  metode 


LRFD.      (Note  :  Semua  unit  panjang  dinyatakan  dalam  mm, 
kecuali dinyatakan secara tertulis) 
Konversi :     1 Ksi = 7 Mpa            1 Mpa = 1 N/mm2                      1 Kips  = 
4516 N             1 inc= 25.4 mm          1ft=12in=304.8mm=0.3048m 
 
All used A36 (fy=36 ksi Fu = 58 ksi) or BJ 37 (Fy=240Mpa
Fu=370MPa), unless mentioned in the problem.

1
Determine Design Strength of WT 8x20 (A36) connected by 19mm diameter of bolt as shown in figure. WT8x20 : A
= 3780mm2 tf=12.8mm tw=7.94mm fy=250Mpa Fu=400Mpa

3@75mm
85mm

47.2mm 51 mm
48mm
d=202mm 100 mm 85 mm

51 mm
3@75mm
Bf=178mm
2@75mm

2
Double angle of L8x6x½ A36 (Fy=36ksi=250Mpa & Fu=50ksi=345Mpa) is connected to ¾ inch of gusset plate as
shown in Figure. Determine :
a. Yield Strength
b. Fracture strength
c. Block Shear strength
d. If 250kN of Deadload and 150KN of live load are applied, is the profile adequate?
xp L8x6x½
6” A=6.75in2=4354.83mm2
xp=0.422in=10.72mm
Pu yp=1.25in=31.75mm
8”
1”=1 in=25.4mm.
E =29.000ksi=2.105Mpa

Fig. 2

3
A double siku L8x6x⅝ A242 (Fy=50ksi=345Mpa & Fu=70ksi=482Mpa) is connected to 1/2inch of gusset plate with
4 bolts ⅞-inch in diameter as shown in figure. Determine :
a. Yield Strength
b. Fracture strength
c. Block Shear strength
d. If 250kN of Deadload and 150KN of live load are applied, is the profile adequate?

xp L8x6x⅝
A=8.36.in2=5393mm2
7½in
xp=0.522 in=13.25mm
yp=1.31 in=33.27mm
8in

1”=1 in=25.4mm.
2in 1.5in E =29.000ksi=2.105Mpa

Determine design strength of a L6x6x½ welded to


4 ½ in of gusset plate where the welded length are 9,
6 dan 3 inch as shown in figure.

L6x6x½
A=19.6in2= 2645mm2
xp=0.0.479in=12.17mm

Gambar 1

5
Double angle L80.80.8  (A total = 
2@70mm  1230mm2) are connected to 13mm 
Xp=22.6 50  2L 80x80x8
40 
gusset plate using 3 bolts with 19mm 
of diameter.  Determine : 
45 a. Yield Strength 
Pmaks? b. Fracture strength   
c. Block Shear strength 
b. Design strength 
D19    
gusset t=13mm  
6
Double angle 2L70.70.7  (A total = 
Xp=21 3 @ 70mm  2L 70x70x7
40  50 2x490mm2) are connected to 16mm 
gusset plate using 4 bolts with 19mm 
25 of diameter.  Determine : 
a.Yield Strength 
Pmaks? b.Fracture strength   
c.Block Shear strength 
D19   c. Design strength 
Fy=240Mpa 
gusset t=16mm   Fu=370Mpa 

7
Determine  design  strength    (ϕPn)  of  tension  member  made  of  WF  200x125  (A  =  1910mm2    tf=5mm     
tw=3mm)  connected by 19mm diameter of bolts as shown in figure.   

50mm 19mm

50 mm

100 mm
19mm
22.2mm
50 mm
3@75mm
125mm 3@75mm


  A WF200x125 is  connected  to 2 
  50mm
splice  plates  on  its  flange  by 
 
16mm diameter of bolts.  
  50 mm
 
 
  Determine :  
  100 mm a. Yield strength 
  b. Fracture strength 
  50 mm  
  WF200x125 : 
  A = 1910mm2   
  125mm 3@60mm   tf=5mm     tw=3mm   

Double angle L7x5x3/4   
xp=1.46in
Gusset plate 1” (A total = 1230mm2) 
A=8.42in2
made of  A572 grade 50
yp=2.32in (Fy=50ksi dan Fu = 65 ksi)  
are connected to 1 inch 
1.5” of gusset plate using 6 
bolts with 7/8 inch  of 
3”
PDL =110k
diameter. Determine : 
PLL =70k 2.5” a. Yield Strength 
b. Fracture strength   
3” 3” c. Block Shear strength 
Profil 2L 7x5x3/4
5@2. 5” d. If 110kips of 
Deadload and 70Kips 
1” of live load are 
applied, is the profile 
adequate? 

Вам также может понравиться