WARNINGS:

1. With Vista or later, you must have Admin privileges. Right-click on CMD.EXE and
select Run As Administrator. You cannot run this from the RUN command as this will
not have Admin rights.

2. During the silent installation, the computer may reboot without warning up to
TWO times. Make sure all other programs are closed before before beginning the
installation. After the computer reboots, log on with the same account. The
installation should resume automatically. If it does not, type the same command
line at the DOS prompt that was run the first time.

3. If a version of the service tool prior to 2008C is currently installed on the


PC, the service tool must be uninstalled first before running the new service tool
install silently. The old service tool can be uninstalled through "Add or Remove
Programs" or "Programs and Features" under "Control Panel". If a procedure was
provided with the old service tool to uninstall it silently, this may be used as
well.

-----

'setup' in the commands below means the fully qualified path to setup.exe. For
example, "D:\setup.exe" /S /v/qn

-----

To install this service tool silently (no user interface shown), use the following
command line:

setup /S /v/qn

Warning: If a reboot of the PC is required by the install, this will happen


automatically.

If a log file of the install is desired, use the following command line instead:

setup /S /v"/qn /l*v %temp%\STPLInstall.log"

The log file will be created in your temp directory.

-----

To install this service tool as an unattended install (user interface shown, but no
user interaction required), use the following command line:

setup /L1033 /v/qb

The user will be prompted by the install if a PC reboot is required. The user
interface will be shown in English. To show the user interface in another language
other than English, replace '1033' with one of the following values:

French = 1036
German = 1031
Italian = 1040
Spanish = 1034
Portuguese = 2070
Japanese = 1041
Chinese (Simplified) = 2052
Danish = 1030
If a log file of the install is desired, use the following command line instead:

setup /L1033 /v"/qb /l*v %temp%\STPLInstall.log"

The log file will be created in your temp directory.

-----

The 'setup' executable will have a return code of '0' if the install was
successful. The return code will be '3010' if the install was successful, but a
reboot is required. Any other return code indicates that the install failed.

-----

To uninstall this service tool silently (no user interface shown), use the
following command line:

setup /S /x /v/qn