TO AC FAIL MONITOR
V1000 - ACM CONTACTS ON POWER
SUPPLY
TO BATTERY FAIL MONITOR
CONTACTS ON POWER SUPPLY
V200 - INPUT MONITOR
Embedded Controller TO ENCLOSURE
TAMPER SWITCH
TO 12 VDC POWER SUPPLY INTERFACE (OPTIONAL -
TO 12 VDC POWER SUPPLY

(REQUIRED) ADDITIONAL MONITORING)


SEE NOTE 6 + - + - + - - + + - + - + - - +
TAMPER AC BAT 12VDC GLASS BREAK
TAMPER AC BAT +12-24VDC + + SEE NOTE 4
D WHITE/BLUE P3 FAIL FAIL IN P4 TO 12 VDC
PIR’S INPUT 1
FAIL FAIL IN
INPUT 9 (SONIC)
A (Input 6) (Input 7) A POWER SUPPLY - -
BLUE P7
B P7 B + +
SHIELD RS-485 RS-485 SHIELD SEE NOTE 2 INPUT 2 INPUT 10 GLASS BREAK
PORT 1 PORT 3 - - (SONIC)
NC NC + +
NC NC INPUT 3 P1 P4 INPUT 11
A
V1000 A
-
+ V200-2 -
+
B B INPUT 4 POWER RESET COMM INPUT 12
RS-485 POWER RESET COMM RS-485
SHIELD - -
SEE NOTE 2 SHIELD PORT 4 + +
PORT 2 NC INPUT 5
NC TX - GREEN INPUT 13
NC - RX - RED -
NC GREEN - COMM OK
RED - COMM FAIL + +
+ P 14 P11 - CAUTION: Some magnetic locks exhibit both high INPUT 6 INPUT 14
-
AUX INPUT 2 -
- AUX INPUT 1
+ inrush current when activated and a high + P2 P5 +
INPUT 7 INPUT 15
NO NO instantaneous break voltage whende-energized - -
C C 15 0 1
RELAY 1 RELAY 2 due to magnetic field collapse. It is recommended + 14 2 +
WARNING: The V1000 is a NC Access Control Manager NC you use of a snubber circuit across the
INPUT 8 13 3 INPUT 16
- 12 4 -
NON-PoE device. DO NOT connect J1 P17 Embedded Controller P18 controlling relay terminals to protect the 5
9 NOT USED P3
11 P6 NOT USED
(Ethernet port) to a PoE capable port. P6 P5 P10 P13 P8 controlling relay contacts. 10 6
NO 98 7 NO
This applies to both direct PoE Power USB PORT1 PORT2 PORT3 PORT4 P8 P9
J1 RS232 C RELAY 1 RELAY 2 C
Sourcing Equipment (Endspan PSE) and TERM TERM BATT TERM TERM
TERM RS-485 RS-485 12VDC
RES RES RES RES NC NC
PoE injector (Midspan PSE) equipment. 1
RES LOOP IN LOOP OUT IN
TCP/IP
Not all PSE's correctly detect Non-PoE- IN OUT IN OUT OFF ON IN OUT IN OUT + - - +
IN OUT
ETHERNET A B SHIELD A B SHIELD - +
capable devices, and such PSE's may not 12 OR 24
HORN OR
function as expected when connected to STROBE VDC POWER
Non-PoE equipment. SUPPLY SEE NOTE 5
Installation Note: Carefully peel the GND
SEE NOTE 3
attached Warning Label from the bottom LAN / WAN / BLUE
WHITE/BLUE
C
of the unit and leave the label attached to
the unit's cover for future reference.
INTERNET C

V100 - DOOR/READER INTERFACE V100 - DOOR/READER INTERFACE


CARD IN / FREE OUT TO 12 VDC POWER SUPPLY CARD IN / FREE OUT TO 12 VDC POWER SUPPLY
(MOST COMMON OPTION) (MOST COMMON OPTION)
RS-485

+ - + - + - - + + - + - + - - +
TAMPER AC BAT 12VDC RED TAMPER AC BAT 12VDC RED
RED FAIL FAIL RED FAIL FAIL
IN IN
BLACK READER PWR READER PWR BLACK BLACK READER PWR READER PWR BLACK
GREEN GROUND P7 GROUND GREEN GREEN GROUND P7 GROUND GREEN
WHITE DATA0/DATA DATA0/DATA WHITE + PIR OR WHITE DATA0/DATA DATA0/DATA WHITE + PIR OR
DATA1/CLOCK READER 1 READER 2 DATA1/CLOCK - REX READER DATA1/CLOCK READER 1 READER 2 DATA1/CLOCK - REX READER
READER READER
DATA RETURN P1 DATA RETURN ORANGE
DATA RETURN P1 DATA RETURN ORANGE
ORANGE P4 ORANGE P4
BROWN
GREEN LED
RED LED V100-0 GREEN LED
RED LED
BROWN BROWN
GREEN LED
RED LED V100-1 GREEN LED
RED LED
BROWN
YELLOW POWER RESET COMM YELLOW YELLOW POWER RESET COMM YELLOW
BEEPER BEEPER + - BEEPER BEEPER + -
- + - + BLUE BLUE DOOR MONITOR - + - + BLUE BLUE DOOR MONITOR
STANDARD DOOR MONITOR HOLD/CD PRESS HOLD/CD PRES STANDARD DOOR MONITOR HOLD/CD PRESS HOLD/CD PRES
SHIELD SHIELD TX - GREEN SHIELD SHIELD SWITCH N/C SHIELD SHIELD TX - GREEN SHIELD SHIELD SWITCH N/C
MAG LOCK SWITCH N/C MAG LOCK SWITCH N/C
RX - RED RX - RED
+ (IN1) DOOR DOOR (IN3) + + (IN1) DOOR DOOR (IN3) +
- (IN1) MONITOR MONITOR(IN3) - - (IN1) MONITOR MONITOR(IN3) -

RS-485
P2 P5 P2 P5
+ (IN2) (IN4) + + (IN2) (IN4) +
REX REX REX REX
- (IN2) (IN4) - - (IN2) (IN4) -
15 0 1 15 0 1
- 14 2 - ELECTRIC DOOR - 14 2 - ELECTRIC DOOR
MAG LOCK NO STRIKE RELAY 13 3 NO MAG LOCK NO STRIKE RELAY 13 3 NO
B + C STRIKE RELAY + STRIKE (LOCK)
+ C STRIKE RELAY + STRIKE (LOCK) B
CRASH SWITCH (OUT 1) 12 4
(OUT 3) C CRASH SWITCH (OUT 1) 12 4
(OUT 3) C
BAR + 11 5 BAR + 11 5
REX SWITCH NC P3 10 6 P6 NC REX SWITCH NC P3 10 6 P6 NC
IN CRASH BAR - NO 98 7 NO IN CRASH BAR - NO 98 7 NO
AUX RELAY P8 P9 AUX RELAY AUX RELAY P8 P9 AUX RELAY
C (OUT 2) (OUT 4) C C (OUT 2) (OUT 4) C
TERM RS-485 RS-485 12VDC TERM RS-485 RS-485 12VDC
NC NC NC NC
RES LOOP IN LOOP OUT IN DOOR #2 RES LOOP IN LOOP OUT IN DOOR #2
DOOR #1 IN OUT DOOR #1 IN OUT
A B SHIELD A B SHIELD - + A B SHIELD A B SHIELD - +
WHITE/BLUE

WHITE/BLUE
SEE NOTE 3 SEE NOTE 5 SEE NOTE 3 SEE NOTE 5
+ - + - + - + -
BLUE

- + - + - + - +

BLUE
+ - - + + - - +
GND

GND
12 OR 24 12 OR 24 HORN OR 12 OR 24 12 OR 24 12 OR 24 12 OR 24 HORN OR 12 OR 24 12 OR 24
HORN OR HORN OR
VDC POWER VDC POWER STROBE VDC POWER VDC POWER VDC POWER VDC POWER STROBE VDC POWER VDC POWER
STROBE STROBE
SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY

RS-485

NOTES, UNLESS OTHERWISE SPECIFIED:


1. THIS INSTALLATION WIRING DIAGRAM IS INTE NDED AS AN EXAMPLE ONLY, AND SHOULD NOT BE INTERPRETED AS THE MANUFACTURER RECOMMENDATION.
2. THE V1000 PHYSICAL RS-485 PORT 1 AND 2 RESIDE ON LOGICAL BUS 1 (P3), WHILE PORT 3 AND 4 RESIDE ON RS-485 LOGICAL BUS 2 (P4).
EXCEPT AS NOTED DO NOT SCALE DRAWING
3. THE TERMINATION JUMPER SHOULD BE IN THE "OUT" POSITION FOR ALL HID VERTX SERIES PANELS EXCEPT FOR THE LAST VERTX SERIES PANEL ON THE RS-485 RUN. DIMENSIONS ARE IN INCHES APPROVALS DATE
A PER ANSI Y14.5M A
THE LAST VERTX SERIES PANEL MUST HAVE THE TERMINATION JUMPER IN THE "IN" POSITION. © 2011, 2015 HID Corporation. All rights
.XX .XXX ANGLES DWN DWG TITLE
4. THE DEFAULT SETTINGS FOR ALL INPUT D EVICES ARE NORMALLY OPEN (N/O), EXCEPT DOOR MONITOR INPUT WHICH IS NORMALLY CLOSED (N/C).
reserved. This document contains
proprietary information and may not be +/- .01 +/- .005 +/- 1 DSGN ACM Embedded Controller
5. THIS NUMBER INDICATES THE INTERFACE ADDRESS OF THE HID VERTX UNIT. (DASH NUMBER NOT PRINTED ON ACTUAL COVER).
used for manufacturing purposes without
permission from the copyright owner.
MATERIAL
CHK Wiring Diagram Example
AVIGILON, the AVIGILON logo, ACCESS SIZE CAGE CODE DWG NO REV
DO NOT DUPLICATE ADDRESSES ON THE SAME BUS. APVD
6. SUPPORTS UP TO (ANY COMBINATION OF) 8 INTERFACE PANELS. SEE THE QUICK INSTALL GUIDE FOR DETAILS.
CONTROL MANAGER and ACM are
trademarks of Avigilon Corporation. HID,
VertX, V1000 and V100 are registered
FINISH
APVD B 3
042616 SCALE: N/A SHEET: 1 of 1
trademarks of HID Global Corporation.
8 7 6 5 4 3 2 1