Вы находитесь на странице: 1из 5
TEST REPORT a bat mgen momen QUT ISIL 1717 05 Oct 2017 1(2) 7 . 2 Determination of the filtration performance of air media filter type 25XS Requested by: BANALE s.r. Dep. CTS Laboratori tel. +39 02 66409991 fax+39 026194115 info@ctslab.eu Air Filter Testing Laboratory Via Zucchi, 39/C 20095 Cusano Milanino (MI) - Italy Bio Analysis Laboratory Via Zucchi, 19 20095 Cusano Milanino (MI) - Italy This report must not be reproduced without the written approval ofthe CTS Laboratories. The report applies to the tested device/sample only. ‘TEST REPORT | No. Date Page n. Annexes n. 1717 05 Oct 2017 2(2) 2 Requested by: BANALE srl. Address: Via Ricotti, 15 20158 Milano - Italy Sample(s): Hand delivered sample, No.1 piece Purpose of the test Measurement of filtration efficiency for different particle size of an air filter media. Sample Supplied Filter named MEDIA FILTER TYPE 25XS. Laboratory's remarks Samples was hand delivered. There is no obvious damage, Test Method The test sample consist of one air media filter of size 600mm (length) x 600mm (width) x 4mm (thickness) mounted in the test duct inside of a galvanized steel flat cell. ‘The spectral efficiency of the filter was measured with optical particle counters (OPC) for the particles with an optical diameter between 0,2-25 wm at the air flow rate of 11,1 L/s. The test aerosol used to determine the spectral efficiency was a solid KCI (Potassium chloride). ‘The test was performed in date: 05.10.2017 Fractional Efficiency by Particle Size Results of the test: See annex: 1 Laboratory Tester Laboratory Manager Davide Degiorgi ) Luca Zucche cee z This report must not be reproduced without the written approval ofthe CTS Laboratories. The report applies to the tested device/sample only. Dep. CTS Laboratory Test Report N. 1717 Air Filter Testing Laboratory ANNEX 1 2ucehi, 39/¢ , Pag. 1di2 20095 Cusano Milanino (MI) Italy Requested by: BANALE s.r. Via Rott 15 20158 Milano tay Date of text 05 oct 2017 ‘opie — 205° | relive humidity; 463% | Atm Pressures 300,685 6a TEST DATA DETAILS Type oftest Fractional ficiency by Particle Size on ~ nie Flter Media Filter Type 25S Ale number: - Dimension Ws: 600x600x4 mm Net itering aes: Filter materia = Filter state: Test aerosol: KCl 20% Airflow rate (W/s}: 11 _ Cycles No: 6 Bee ali ‘Sampling time: 20s o ‘TEST RESULTS Partileske | ficiency Measurement by Parte Sue Interval ‘Mean Concentration (N/cf) Efficiency Uncertainty, (um) (um) Upstream Downstream (%) u 02-03 028 1e7assia 15964150 468 21457 03-05 039 sa7iasaaa 1ass2087 = 88 2081 05-07 059 9978629, 8917476 10,46 £1,828 084 1144270 995196 12,64 £1,995 141 172766 | (20,89 £0,628 245 15397 32,472,068 387 2906 55,28 22,882 7.07 42 £4,243 i _ 15.82 224 22,154 >20 571 50 23,174 The uncertainty ofthe measured efficiencies is reported on @ 95% confidence limit. Dep. CTS Laboratory Clean Tech System s e-mail info@ctslab.2u i, 3 ano Mila www.ctslab.eu T F

Вам также может понравиться