Вы находитесь на странице: 1из 5

Save a life today

Be ready every time,


everywhere, with a
Mediana AED
š 7kjecWj_Yi[b\#j[ij
š L_ikWbikffehj_Yedi MEDIANA
š 7kZ_Xb[le_Y[fhecfji HEARTON
š H[Wbj_c[]k_ZWdY[
AED A10
Mediana Automated
External Defibrillator A10
š;Wiojeki[m_j^ehm_j^ekjjhW_d_d]
MEDIANA 1 SOFT CARRY CASE to protect and easily transport
the AED. Clear cover to view the status indicator. Side 9 VISUAL ICONS LED indicator lights flash with the
HEARTON Pockets for manual, spare pads, spare battery. corresponding voice prompts. Visual Icons clarify the

AED A10 necessary actions.

EASY TO USE
1. STATUS INDICATOR.
Ensure the status indicator displays ‘O.’

LCD TYPE ECG and text display.

J SPEAKER Acoustic indicator for real time guidance.


2 STATUS INDICATOR Unit status and
battery capacity.

K SHOCK BUTTON Flashing button


2. PUSH BUTTON.
indicates ‘Ready for shock delivery.’ Push the
Open the lid using the push button. 3 CONNECTING SOCKET Defibrillator button to deliver shock.
pads connector socket.

4 POWER ON BUTTON The toggle key for L PUSH BUTTON to open the cover.
turn on/off.

3. PLUG IN PADS. 5 IRDA PORT IR communication port


Remove pads from protective between PC and AED.
packaging, then plug into the AED and
apply to the patient. 6 DC INPUT
PORT (TRAINER
ONLY) 15V/1.5A

7 SERIAL PORT
(OPTION) Exterior
8 SD CARD INSERT AND printer demanded.
USB PORT Review stored data M PADS Adult pads for over 8 year olds.
and software upgrade. Pediatric pads for under 8 year old.

4. PUSH THE ‘POWER ON’ BUTTON.


Voice prompt will respond:
“Unit OK” 14 reasons to N BATTERY Disposable
LiMnO2 (non-rechargeable).
“Adult Pads”
choose Mediana...
SPECIFICATIONS
DEFIBRILLATION ELECTRIC SHOCK

MEDIANA MEDIANA Waveform: Biphasic Truncated Exponential (BTE)


Waveform (impedance compensation)

HEARTON HEARTON
Energy: Adult: 185 to 200J (±5%)
Paediatric: 45 to 50J (±5%)
Operating Mode: Semi-Auto

AED A10 AED A10 ECG


Lead:
Patient Impedance:
II (RA, LL)
25 to 175ohm

š 7kjecWj_Yi[b\#j[ij ™ ;dgZkZgndcZb^cjiZYZaVn!Vk^Xi^bh
Heart Rate:
Accuracy:
20 to 300 per min
1 per min

š L_ikWbikffehj_Yedi X]VcXZd[hjgk^k^c\VhjYYZcXVgY^VXVggZhi Detection: V/F more than 200 µV


V/F more than 160 per min
YgdehWn,"&%# Lead off detection: Detected and voiced

š 7kZ_Xb[le_Y[fhecfji ™ 6abdhi.*d[hjYYZcXVgY^VXVggZhi
Filter:

INDICATION
0.5 to 30Hz

k^Xi^bhY^ZWZ[dgZgZVX]^c\]dhe^iVa# CONTROLS
š H[Wbj_c[]k_ZWdY[
Don’
Standard: Green Power on/off button. Red Shock button

™ 8EGZ[[ZXi^kZanVYb^c^hiZgZY^bbZY^ViZan INDICATORS

Miss t
š;Wiojeki[m_j^ehm_j^ekjjhW_d_d] V[iZghjYYZcXVgY^VXVggZhi!XVcYdjWaZi]Z
Visible: ICON (LED) Indicator, Status LCD (unit status
and battery capacity).

X]VcXZd[hjgk^kVa[dgVk^Xi^b# Audible: Audio speaker (Voice prompt), Beep (CPR

Our FREE E-learning course at: UNIT 1


! ™ HZkZcdjid[iZcXVgY^VXVggZhihdXXjg
djih^YZd[]dhe^iVa#8jggZcian^ci]ZJ@!
PHYSICAL
Dimensions:
indication).

314H x 259W x 109mmD


Weight: Approx. 2.95kg (including battery,
dcan'"(d[i]ZhZeZdeaZhjgk^kZ# excluding pads).
www.medianadefib.co.uk/e-learning SELF-TEST
™ I]Z9ZeVgibZcid[=ZVai]]VhViVg\Zid[ Cycle: Every 24 hours, 1 week, 1 month

You do not need training to use the Mediana AED, as it is eaVX^c\(!%%%cZlYZÄWg^aaVidgh^cejWa^X Test Result:
Power on self-test, battery insertion self-test
Status LCD displays ‘O’ / ‘X’
designed for untrained persons. It talks you through step-by- eaVXZhi]gdj\]dji:c\aVcY#
DATA BACKUP AND COMMUNICATION
step directions, so there is no risk of shocking a casualty in UNIT 2
error. ™ :meadgZg!H^gGVcjae];^ZccZh!^hVa^kZidYVn Standard SD card, infrared communication port

aVg\Zani]Vc`hidVYZÄWg^aaVidgadXViZYVi ACCESSORY SPECIFICATIONS


ADULT/PAEDIATRIC PADS
Training however, can save vital seconds and dispel any 7g^hidaV^gedgi# Standby Life: 2 years from date of manufacture
confusion if you encounter a Cardiac Emergency. This course Electrodes: Disposable pads

has been designed for people with little knowledge of First Aid, ™ :VganYZÄWg^aaVi^dcXVcig^eaZVk^Xi^bh Placement: Adult: Anterior-lateral
Paediatric: Anterior-posterior
providing information in four bite-size sections that are easy to X]VcXZd[hjgk^kVa# Minimum active gel area: Adult: 96.25cm²
remember. UNIT 3
Paediatric: 69.53cm²
Cable Length: 1.7m
Environmental Conditions
You will be guided through four units; Temperature: Operation: 0 to 43°C (32 to 109.4°F).
Storage: 0 to 43°C (32 to 109.4°F).
Unit 1: Encountering a Casualty having a Cardiac Arrest Relative Humidity: 5 to 95% RH (non-condensing).

Unit 2: Airway, Breathing, Circulation Altitude: Operation: 0 to 4,575m


Storage: 0 to 12,192m
Unit 3: Using the Mediana AED A15 Shock: Acceleration: 100G (+/- 10%).
Vibration: Frequency: 10Hz to 2000Hz
Unit 4: After the defibrillation of the Casualty UNIT 4 Acceleration: 10Hz to 100Hz: 5,0 (m/s²)²/Hz
10Hz to 200Hz: -7 dB per octave
100Hz to 2000Hz: 1,0 (m/s²)²/Hz
All information included in this E-Learning Resource Drop Height: 1m
has been based on the guidelines of: Water and Dust Resistance: IP54 (IEC60529)
BATTERY
The European Resuscitation Council Type: Disposable LiMnO2, long-life primary cell
Voltage/Capacity: 15V, 4200 mAh
The UK Resuscitation Council Shelf Life: 2 years from date of manufacture
(in the original packaging).
Standby Life: 5 years from date of manufacture
PLEASE NOTE: J^[h[Wh[ib_]^jlWh_Wj_edi_def[hWj_d]\[Wjkh[ie\j^[C[Z_WdW7'+WdZ7'&CeZ[bi$IjkZ[dji (inserted in the AED).
efj_d]\ehj^[[#b[Whd_d]Yekhi[m_bbX[d[Åj]h[Wjbo"h[]WhZb[iie\j^_i"XkjWh[WZl_i[Z"j^Wj_dijhkYj_edi_dj^[ Discharge: A minimum of 200 shocks
Yekhi[Wffboexclusivelyjej^[A15 Model$<ehj^[]h[Wj[ijX[d[Åj"WbbijkZ[djii^ekbZh[\[hjej^[ef[hWj_d] (except the CPR period between the
cWdkWb\ehj^[A10 Modelm^_Y^Yb[Whbo[nfbW_dij^[ib_]^jZ_\\[h[dY[m^[dijWhj_d]kfj^[7'&$ defibrillation therapy), or 10 hours of
operating time at 20°C
>c[dgbVi^dcXdggZXiVii^bZd[\d^c\idegZhh#HjW_ZXiidX]Vc\Zl^i]djicdi^XZ#
MEDIANA MEDIANA
HEARTON HEARTON
AED A10 AED A10
C[Z_WdW7'&>[WhjEd7;: 8[Wj9FH
HeartOn AED Semi-Automatic Resuscitation Aid

Semi-Automatic. Compact.
Support LED Icons. Audible tone guides CPR compression speed.
Voice Prompt. Pre-programmed to 110 beats per minute, adjustable.
Self-Test. Display visible in all light conditions.
Status Indicator. Long-life renewable battery included.
Adult and Paediatric Pads.
Suitable for schools, teams and clubs.
REF PRODUCT DESCRIPTION UNIT PACK
2860 Beat CPR Resuscitation Aid 1 1

REF PRODUCT DESCRIPTION UNIT PACK


2864 Mediana A10 HeartOn Semi-Automatic 1 1
AED

IeÅWC[jWbMWbb9WX_d[j
White

Ideal first aid room cabinet

C[Z_WdW7'&7;:JhW_d[h Suitable for clinical environments


Durable stove-enamelled construction
HeartOn AED Semi-Automatic Not recommended for medicine storage

Semi-Automatic.
Ten Available Training Scenarios. REF PRODUCT DESCRIPTION SIZE UNIT PACK
Infrared Remote Control. 214 Sofia Metal Wall Cabinet White 46cmH x 30cmW x 14cmD 1 1
Suitable for schools, teams and clubs.

REF PRODUCT DESCRIPTION UNIT PACK


2885 Mediana A10 HeartOn Trainer 1 1
AED
2886 Mediana A10 Training Pads Adult Only 1 1

EkjZeeh>[Wj[ZMWbb9WX_d[j
with Alarm

C[Z_WdW7'&FWZi Carbon steel cabinet.


Adult and Paediatric Anti-theft radio with magnetic sensor.
Thermally regulated heating system.
For outdoor use.
Replacement Pads. Alarm system.
2 years Standby life. Safe and visible.
1.7m Cable length. Wall mountable.
AED not included.

REF PRODUCT DESCRIPTION UNIT PACK


2866 Mediana A10 Adult Pad Disposable 1 1 REF PRODUCT DESCRIPTION SIZE UNIT PACK
2103 Outdoor Heated Wall with Alarm 48cmH x 42.5cmW x 21.5cmD 1 1
2867 Mediana A10 Paediatric Disposable 1 1 Cabinet
Pad

7;:Fh[fA_j Kd_l[hiWb7;:8hWYa[j
Contains the basic items typically required
C[Z_WdW7'&8Wjj[hoFWYa for an AED Emergency Universal AED bracket.
Sturdy metal bracket is ideal for mounting any AED on a wall.
Disposable.
LiMnO2 Non-Rechargeable. CONTENTS 12.3cmH x 19cmW x 9.5cmD
Two years shelf life. 1 Cleansing Wipe
Five years standby life. 1 Clinical Waste Bag
1 Disposable Razor
1 Gloves (Pair)
2 Hand Towels
REF PRODUCT DESCRIPTION UNIT PACK 1 Resuscitation Device
2865 Mediana A10 Battery Pack 1 1 1 Shears

REF PRODUCT DESCRIPTION UNIT PACK REF PRODUCT DESCRIPTION UNIT PACK
2877 AED Prep Kit 1 1 2879 Universal AED Bracket 1 1
MEDIANA
HEARTON
AED A10
Mediana Automated
External Defibrillator A10

Open Briefing
The Workbox
4th Floor, PZ360
St Mary's Terrace
Penzance
Cornwall TR18 4DZ

01736 800 767


info@openbriefing.org
www.openbriefing.org