Вы находитесь на странице: 1из 9

This simplifieddesign sheet takes the following limitations/assumptions

1) There is no moment on the footing base, ie pinned column


2) Punching shear reinforcement design is not included. Need to keep ratio less than 1
Sankhe Associates ISOLATED FOOTING DESIGN

Designer N.P.
LOGO DESIGN OF ISOLATED FOOTING Checker
Component: Date 5/23/2014 SHEAR TABLE
One-way shear strength
Input Params:
Length of Footing: 2.3 m
Width of Footing: 2.3 m
Depth of Footing: 0.5 m
Maximum Axial Load at SLS: 1000 kN
Maximum Axial Load at ULS: 1500 kN
Column Length: 0.3 m
Column Width: 0.55 m
Soil Bearing Capacity: 200 kPa
Grade of Concrete 20 Mpa
Grade of Steel 500 Mpa
cover to rebars 40 mm

Calculations:
Bearing pressure under footing 189.03592 kPa
O.K. IN BEARING …………1)

Punching Check
Effective Depth 0.46 βc 0.5454545
Control Perimeter 3.54 m ks 1
Stress at Contr. P 0.9211496 Mpa
Concrete Cap. 1.118034 Mpa
O.K. IN PUNCHING
Reinforcement Calculation
Along Length Along Width

Moment at face of column(kN): 141.77694 Moment at face of column(kN): 108.54797 Bearing pressure ULS
Status: OK Status: OK
Area of Steel Required mm2/m: 738.14204 Area of Steel Required mm2/m:: 600
ρst 0.16% ρst 0.13%
Oneway Shear Check
Along Length Along Width
Shear at distance d from face 153.11909 Shear at distance d from face 117.67486
vc 0.5 Mpa vc 0.5 Mpa
Fcap 230 kN Fcap 230 kN
OK IN ONE WAY SHEAR OK IN ONE WAY SHEAR

Structural Calculations. 2
Sankhe Associates ISOLATED FOOTING DESIGN

Structural Calculations. 3
Sankhe Associates ISOLATED FOOTING DESIGN

SHEAR TABLE
One-way shear strength

Bearing pressure ULS 283.55388 kPA

Structural Calculations. 4
Created By: Project:
Nimish P. Company Logo P.E. N.P.
BEAM FLEXURE DESIGN(MODIFIED FOR FOOTINGS) Chckd by:
BASED ON IS 456 Date
Moment = 108.54797 kN.m
Width = 1000 mm
Depth = 500 mm
Ten.Cover = 40 mm Comp, Cover 40 mm Covers till Steel CGS
Eff. Depth = 460 !The effective depth needs to be inputted by user to account for
bar dia subtraction
fc' = 20 Mpa Ec = 22360.6798 mpa
fy = 500 Mpa
Ductile Design 2 1: Yes 2: No Ductile design not working yet!!
Es = 200000 Mpa
Ast,min = 0.12% mm2
Ast,max = 4.00% mm2
Ast = 559.48047 mm2 ρ,st = 0.122% DESIGN
OK
Ast' = 0 mm2
Bar Table Ast,total 600 mm2
Dia 6 8 10 12 14 16 20 25 32 40
Area(mm2) 28.3 50.3 78.5 113 154 201 314 491 804 1257 for two type of bars
No of Tensionbars 22 12 8 6 4 3 2 2 2 2 R1 8 N1 2
No of compr bars ### ### ### ### ### ### ### ### ### ### R2 16 N2 2.48
Calculations:
xu,limit = 209.77 mm
Mu,limit = 561.69586 kN.m
fy/fck = 25 modular ratio
(M/0.87fckbd^2)= 0.029482 dimensionless quant
compression steel calculations
esc = 0.002833
fsc = 435 Mpa stress
0
Yes 2
No

2
600
0.12%
Created By: Project:
Nimish P. Company Logo P.E. N.P.
BEAM FLEXURE DESIGN(MODIFIED FOR FOOTINGS) Chckd by:
BASED ON IS 456 Date
Moment = 141.77694 kN.m
Width = 1000 mm
Depth = 500 mm
Ten.Cover = 40 mm Comp, Cover 40 mm Covers till Steel CGS
Eff. Depth = 460 !The effective depth needs to be inputted by user to account for
bar dia subtraction
fc' = 20 Mpa Ec = 22360.6798 mpa
fy = 500 Mpa
Ductile Design 2 1: Yes 2: No Ductile design not working yet!!
Es = 200000 Mpa
Ast,min = 0.12% mm2
Ast,max = 4.00% mm2
Ast = 738.14204 mm2 ρ,st = 0.160% DESIGN
OK
Ast' = 0 mm2
Bar Table Ast,total 738.142035 mm2
Dia 6 8 10 12 14 16 20 25 32 40
Area(mm2) 28.3 50.3 78.5 113 154 201 314 491 804 1257 for two type of bars
No of Tensionbars 27 15 10 7 5 4 3 2 2 2 R1 8 N1 2
No of compr bars ### ### ### ### ### ### ### ### ### ### R2 16 N2 3.17
Calculations:
xu,limit = 209.77 mm
Mu,limit = 561.69586 kN.m
fy/fck = 25 modular ratio
(M/0.87fckbd^2)= 0.0385071 dimensionless quant
compression steel calculations
esc = 0.002833
fsc = 435 Mpa stress
0
Yes 2
No

2
738.142
0.15%
Percentage Reinft for columns Percentage Reinft for beams

b 500 b 500
d 1200 d 1000
Bar dia 20 rho 32
Number along b 4 N 6
Number along d 12
% 0.97%
N 28
AST 8796.459
rho 1.47%

Вам также может понравиться