Вы находитесь на странице: 1из 23

Installation Guide for AC -6000 V1.

4
AC-6000
Fingerprint Identification Terminal

Doc.
Doc. Ver.
Ver. :: V1.10
V1.10
Sep.,01.2009
Sep.,01.2009
R&D
R&D Center
Center
Union
Union Community
Community Co.,
Co., Ltd.
Ltd.
1. Power Connector connection

P-3 Power Adapter


GND (BK) - 2 P-2
+12V (RE) - 1 P-1 Interface

* * Insert the Power Cable to VIN/ PG Terminal Block


in right color matching as the picture

Installation for AC-


AC-6000 V1.0
2
2. Connecting Ethernet & Power Cable

Adapter

UTP 10Base-T
RJ45 Switch Hub or Hub

** UTP Connector

Installation for AC-


AC-6000 V1.0
3
3. Main Board Feature
RV451 Approach Sensor Distance Control
Lo w H igh J304 Communication/ Status Input Switch Setting I [ Lock Type Selection ]
J303 Door Lock Control Output SW301 : ST/ M [ Strike/ Motor/ Dead- bolt Lock ]
A/ D [ Auto Door Selection ]
SW301~ 303 Lock Type Switch
SW302 : NO/ MT [ Normal Open Relay Contact ]
NC [ Normal Close Relay Contact ]
SW303 : ST/ AT.DR [ Strike, Auto Door, Dead bolt ]
15 MT [ Motor Lock Selection ]
14 Switch Setting II [ RS485 T_Resistor Selection ]
13 SW251 : ON [ 120ohm termination resistor ]
12 1 OFF [ Open the termination resistor ]
11 2 Switch Setting III [ RS232RS485 Selection ]
10 3 SW252,253 : RS232 [ J304 Pin 6&7 Enabled ]
9 4 RS485 [ J306 Pin 8&9 Enabled ]
8
7 1 J303 Door Lock Control Output
J351 Power Input
6 2 1[ L1 ] : Lock Output 1
5 2[ LC ] : Lock COM for Output 1
1 3[ L2 ] : Lock Output 2
4 J454 Door Phone
2 4[ G ] : Ground for Lock Control
3
SW251 RS485 Termination J304 communication/ Status Input
2 Resistor Select Switch 1 [ IO ] : Inside Open
1 2 [ M0 ] : Door Monitor 0
F351 Fuse 3 [ M1 ] : Door Monitor 1
SW252,253 RS232
RS232RS485 4 [ M2 ] : Door Monitor 2
Select Switch 5 [ G ] : Ground [ Door Status ]
6 [ R2T] : RS232 TXD Output
7 [ R2R] : RS232 RXD Input
8 [ R4A] : RS485 A
9 [ R4B] : RS485 B
10[ G ] : Ground [ Serial com Port ]
11[ WI0] : Wiegand Input 0
12[ WI1] : Wiegand Input 1
13[ WO0] : Wiegand Output 0
14[ WO1] : Wiegand Output 1
15[ G ] : Ground [ Wiegand interface ]

J351 Power Input


1 [ VIN ] : DC Power Input
J152 RJ45 Jack for Ethernet 2 [ PG ] : Ground for DC Power
J201 USB2.0 Client
J454 Door Phone Interface
J202 USB1.1 Host 1 [ DPV ] : Door Phone Voltage IN
J203 USB1.1 Host 2 [ DPS ] :Door Phone Signal

Installation for AC-


AC-6000 V1.0
4
4. Keypad Board Feature

J671 LCD/ AC97 J602 FP/ Camera/ Button


FPC 40pin FPC 50pin

J603 Camera
J601 UV LED

J605 Cover Open

J604 FP Sensor

J673 Speaker

J672 LCD
FPC 45pin

Installation for AC-


AC-6000 V1.0
5
5. Schematic for Door Lock Interface

VIN Door Lock Interface


SW301 FB301
ST//MT 1 2 Lock1_COM SW302
NC NO/MT
AT.DR K301 10 LOCK1 LOCK1
VCC_5V 9
8
C303
3 Lock1_COM J303

1
4 BI-35-DB250-04
D301 5 1
1 2 Lock 1
12 MT LOCK2 3 Lock 1 Com
3 A

2
4 Lock 2
SW303 Gnd

1
R305
LockCon1 1 2 2 Q301 C304
1 2 2 AT.DR/ST
R306 Terminal Block 4PIN
1

K302
10
VCC_5V 9
8
C305 LOCK2
3 VIN
K

4
D302 5 1 2
1 FB302

1
12
3 A

R307
LockCon2 1 2 2 Q302

2
1 2
C306
R308
1

Installation for AC-


AC-6000 V1.0
6
6. Connection of Wires to terminal blocks
J304 communication/ Status Input

15[ G ] : Ground [ Wiegand ]

14[ WO1] : Wiegand Output 1

13[ WO0] : Wiegand Output 0


J303 Door Lock Control Output
12[ WI1] : Wiegand Input 1
1 [ L1 ] : Lock Output 1
11[ WI0] : Wiegand Input 0
2 [ LC ] : Lock COM for Output 1
10[ G ] : Ground [ Serial Port ]
3 [ L2 ] : Lock Output 2
9 [ R4B] : RS485 B
4 [ G ] : Ground for Lock Control
8 [ R4A] : RS485 A

7 [ R2R] : RS232 RXD Input J351 Power Input

6 [ R2T] : RS232 TXD Output 1 [ VIN ] : DC Power Input

5 [ G ] : Ground [ Input ] 2 [ PG ] : Ground for DC Power

4 [ M2 ] : Door Monitor 2
J454 Door Phone Interface
3 [ M1 ] : Door Monitor 1
1 [ DPV ] : Door Phone Voltage IN
2 [ M0 ] : Door Monitor 0
2 [ DPS ] :Door Phone Signal
1 [ IO ] : Inside Open

Installation for AC-


AC-6000 V1.0
7
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)
8.1. Connect with One System/ One Lock

Lock Type Select S/W

AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
(-)Black
15 G SW303
wo1 SW302 (+)Red
14

13 wo0 SW301 ON

12 wi1 Lock(+) 12 3 4

L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B Lock(-)
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Inside Open
Door Monitor

Installation for AC-


AC-6000 V1.0
9
8. Connecting Dead-Bolt Type Door Lock (Fail Safe)
8.2. Connect with Two Systems/ One Lock
Lock Type Select S/ W
System 1
System 2 (-)Black
AutoDoor/ST == MT AutoDoor/ST == MT
NC ======== NO/MT NC ======== NO/MT
ST/MT == AutoDoor ST/MT == AutoDoor
(+)Red

15 G SW303 15 G SW303 ON

12 3 4
14 wo1 SW302 14 wo1 SW302

13 wo0 SW301 13 wo0 SW301

12 wi1 Lock(+) 12 wi1


L1 1 L1 1
11 wi0 11 wi0
LC 2 LC 2
10 G 10 G
L2 3 L2 3
9 R4B Lock(-) 9 R4B
G 4 G 4
8 R4A 8 R4A

R2R VIN 1 R2R VIN 1


7 7
R2T PG 2 R2T PG 2
6 6

5 G 5 G
DPV 1 DPV 1
4 M2 4 M2
DPS 2 DPS 2
3 M1 3 M1

2 M0 2 M0
SW251 SW251
1 IO 1 IO

Door Monitor

Installation for AC-


AC-6000 V1.0
10
9. Connecting Strike Type Door Lock (Fail Safe)
9.1. Connect with One system/ One Lock

Lock Type Select S/W

AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
(-)Black
15 G SW303 (+)Red
14 wo1 SW302

13 wo0 SW301

12 wi1 Lock(+)
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B Lock(-)
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Inside Open
Door Monitor

Installation for AC-


AC-6000 V1.0
11
9. Connecting Strike Type Door Lock (Fail Safe)
9.2. Connect with Two systems/ One Lock
Lock Type Select S/ W
System 1
System 2 (-)Black
AutoDoor/ST == MT AutoDoor/ST == MT
NC ======== NO/MT NC ======== NO/MT (+)Red
ST/MT == AutoDoor ST/MT == AutoDoor

15 G SW303 15 G SW303
14 wo1 SW302 14 wo1 SW302

13 wo0 SW301 13 wo0 SW301

12 wi1 Lock(+) 12 wi1


L1 1 L1 1
11 wi0 11 wi0
LC 2 LC 2
10 G 10 G
L2 3 L2 3
9 R4B Lock(-) 9 R4B
G 4 G 4
8 R4A 8 R4A

R2R VIN 1 R2R VIN 1


7 7
R2T PG 2 R2T PG 2
6 6

5 G 5 G
DPV 1 DPV 1
4 M2 4 M2
DPS 2 DPS 2
3 M1 3 M1

2 M0 2 M0
SW251 SW251
1 IO 1 IO

Door Monitor

Installation for AC-


AC-6000 V1.0
12
10. Connecting Strike Type Door Lock (Fail Secure)
10.1. Connect with One system/ One Lock

Lock Type Select S/W


AutoDoor/ST == MT
NC === === NO/MT
ST/MT == AutoDoor
(-)Black
15 G SW303 (+)Red
14 wo1 SW302

13 wo0 SW301

12 wi1 Lock(+)
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B Lock(-)
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Inside Open
Door Monitor

Installation for AC-


AC-6000 V1.0
13
10. Connecting Strike Type Door Lock (Fail Secure)
10.2. Connect with Two systems/ One Lock
Lock Type Select S/ W
System 1
System 2 (-)Black
AutoDoor/ST == MT AutoDoor/ST == MT
NC ======== NO/MT NC ======== NO/MT (+)Red
ST/MT == AutoDoor ST/MT == AutoDoor

15 G SW303 15 G SW303
14 wo1 SW302 14 wo1 SW302

13 wo0 SW301 13 wo0 SW301

12 wi1 Lock(+) 12 wi1


L1 1 L1 1
11 wi0 11 wi0
LC 2 LC 2
10 G 10 G
L2 3 L2 3
9 R4B Lock(-) 9 R4B
G 4 G 4
8 R4A 8 R4A

R2R VIN 1 R2R VIN 1


7 7
R2T PG 2 R2T PG 2
6 6

5 G 5 G
DPV 1 DPV 1
4 M2 4 M2
DPS 2 DPS 2
3 M1 3 M1

2 M0 2 M0
SW251 SW251
1 IO 1 IO

Door Monitor

Installation for AC-


AC-6000 V1.0
14
11. Connecting EM Type Door Lock (Fail Safe)
11.1. Connect with One system/ One Lock

Lock Type Select S/W


AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
(-)Black
15 G SW303 (+)Red
14 wo1 SW302

13 wo0 SW301

12 wi1 Lock(+)
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B Lock(-)
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Inside Open
Door Monitor

Installation for AC-


AC-6000 V1.0
15
11. Connecting EM Type Door Lock(Fail Safe)
11.2. Connect with Two System/ One Lock
Lock Type Select S/ W
System 1
System 2 (-)Black
AutoDoor/ST == MT AutoDoor/ST == MT
NC ======== NO/MT NC ======== NO/MT (+)Red
ST/MT == AutoDoor ST/MT == AutoDoor

15 G SW303 15 G SW303
14 wo1 SW302 14 wo1 SW302

13 wo0 SW301 13 wo0 SW301

12 wi1 Lock(+) 12 wi1


L1 1 L1 1
11 wi0 11 wi0
LC 2 LC 2
10 G 10 G
L2 3 L2 3
9 R4B Lock(-) 9 R4B
G 4 G 4
8 R4A 8 R4A

R2R VIN 1 R2R VIN 1


7 7
R2T PG 2 R2T PG 2
6 6

5 G 5 G
DPV 1 DPV 1
4 M2 4 M2
DPS 2 DPS 2
3 M1 3 M1

2 M0 2 M0
SW251 SW251
1 IO 1 IO

Door Monitor

Installation for AC-


AC-6000 V1.0
16
11. Connecting EM Type Door Lock (Fail Safe)
11.3. Connect with One system/ Two Locks * * Use external DC Power adapter

Lock 1
Lock Type Select S/W
AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor
External
15 G SW303
12V 3A
14 wo1 SW302 Adapter
13 wo0 SW301
(+) (- )
12 wi1
1
Lock(-) (-)Black
L1
11 wi0
2
LC
Lock(+) (+)Red
10 G
L2 3
9 R4B
G 4
8 R4A Door Monitor
R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Inside Open Lock 2

Installation for AC-


AC-6000 V1.0
17
12. Connecting Auto-Door (Contact Control)
12.1. Connect with One system/ One Door
Auto Door Operating Part Auto Door Motor

Lock Type Select S/W Auto-


Auto-Door Sensor
Auto-
Auto-Door Monitor
AutoDoor/ST == MT
NC === === NO/MT
ST/MT == AutoDoor Sensor Input Line

15 G SW303
14 wo1 SW302
9P CONN
13 wo0 SW301

12 wi1 Lock(+)
L1 1
11 wi0
LC 2
G
Lock(-)
10 L2 3
9 R4B
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6

5 G Inside Door
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Installation for AC-


AC-6000 V1.0
18
12. Connecting Auto-Door (Contact Control)
12.2. Connect with Two systems/ One Door
Auto Door Operating Part Auto Door Motor

Lock Type Select S/ W Auto-


Auto-Door Sensor
Auto-
Auto-Door Monitor
System 1
System 2
AutoDoor/ST == MT AutoDoor/ST == MT Sensor Input Line
NC ======== NO/MT NC ======== NO/MT
ST/MT == AutoDoor ST/MT == AutoDoor

15 G SW303 15 G SW303
14 wo1 SW302 14 wo1 SW302 9P CONN
13 wo0 SW301 13 wo0 SW301

12 wi1 Lock(+) 12 wi1 Lock(+)


L1 1 L1 1
11 wi0
LC 2 Lock(-) 11 wi0
LC 2 Lock(-)
10 G 10 G
L2 3 L2 3
9 R4B 9 R4B
G 4 G 4
8 R4A 8 R4A

R2R VIN 1 7 R2R VIN 1


7
R2T PG 2 6 R2T PG 2
6

5 G 5 G
DPV 1 DPV 1
4 M2 4 M2
DPS 2 DPS 2
3 M1 3 M1

2 M0 2 M0
SW251 SW251
1 IO 1 IO

Installation for AC-


AC-6000 V1.0
19
13. Connecting Motor Lock

Lock Type Select S/W


AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor

15 G SW303
SW302
Blue : Motor 2
14 wo1
Brown : Motor 1
SW301
13 wo0 Orange: Door Monitor
12 wi1
1
Motor 1 White : Ground
L1
wi0
Yellow : Unlock Signal
11 LC 2
Motor 2 Red : Lock Signal
10 G
L2 3 Black : Ground
9 R4B
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6
GND G Inside Door
5
DPV 1 Open S/ W
4 M2
DPS 2
3 M1

2 M0
SW251
IO
** Select motor lock 1st in the Lock setting
1
at the configuration menu.
Inside Open

Installation for AC-


AC-6000 V1.0
20
14. Connecting 2 Emergency Lamps

Emergency Emergency
Lamp 1 Lamp 2

Lock Type Select S/W

AutoDoor/ST == MT
NC ======== NO/MT
ST/MT == AutoDoor

15 G SW303
14 wo1 SW302

13 wo0 SW301 12 V (+) Ground (-


(- ) 12 V (+) Ground ( - )

12 wi1 Lock 1 (+)


L1 1
11 wi0
LC 2
10 G Lock 2 (+)
L2 3
9 R4B Lock(-)
G 4
8 R4A

R2R VIN 1
7
R2T PG 2
6

5 G
DPV 1
4 M2
DPS 2
3 M1

2 M0
SW251
1 IO

Installation for AC-


AC-6000 V1.0
21
15. Connecting Wiegand Output to External Controller

Data 0

Data 1

GND

15 G

14 wo1

13 wo0 External Access Controller Input


12 wi1
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B
G 4
AC6000 Supported Formats
8 R4A
-26 bits
R2R VIN 1 -34 bits
7

6 R2T PG 2 (Site Code + User ID) = User Card number for controller
5 G
DPV 1
4 M2
DPS 2
3 M1

2 M0

1 IO

Installation for AC-


AC-6000 V1.0
22
16. Appendix
16.1 RS-232 Interface

RS-232 TXD
RS-232 RXD
Ground
15 G

14 wo1

13 wo0

12 wi1
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B
G 4
8 R4A

7 R2R VIN 1

6 R2T PG 2

5 G
DPV 1
4 M2
DPS 2
3 M1

2 M0

1 IO
Communication Port Select S/W
SW252
SW253 RS232 === RS485

Installation for AC-


AC-6000 V1.0
23
16. Appendix
16.2 RS-485 Interface

RS-485A
RS-485B
Ground
15 G

14 wo1

13 wo0

12 wi1
L1 1
11 wi0
LC 2
10 G
L2 3
9 R4B
G 4
8 R4A

7 R2R VIN 1

6 R2T PG 2

5 G
DPV 1
4 M2
DPS 2
3 M1

2 M0

1 IO
Communication Port Select S/W
SW252
SW253 RS232 === RS485

Installation for AC-


AC-6000 V1.0
24