Вы находитесь на странице: 1из 7

VENTURIMETRO ROTAMETRO DIAFRAGMA

Q (cm^3/s) h1 (cm) h2 (cm) h3 (cm) h4 (cm) h5 (cm) h6 (cm) h7 (cm)


366.667 34.5 12 27.3 24.7 19 19.5 4
333.333 32 12.5 25.5 23.3 17.5 18 5
300 28.7 13.5 23.5 21.5 16 16.3 6
266.667 26.3 14 21.5 20 14.5 15 6.5
233.333 23.9 14.3 20 18.9 13.4 13.5 7
200 21.5 14.5 18.5 17.6 12.3 12.4 7.8
166.667 19.5 14.5 17.3 16.5 11.2 11.4 8
133.333 17.7 14.4 16.2 15.8 10.5 10.6 8.5
100 16.5 14.4 15.4 15.2 10 10.1 8.9
66.667 15.4 14.4 14.7 14.5 9.5 9.6 9

Diametro de la garganta, (cm): 1.5 Área de la garganta, A2 (cm^2): 1.77


Diametro de la Tuberia, (cm) : 3.175 Área de la tuberia, A1 (cm^2): 7.92
Diametro del orificio (cm) 2 Área del orificio, A3 (cm^2): 3.1416
Calculo de la velocidad real (garganta), v (cm/s):
�_𝑅2=𝑄_𝑅/𝐴_2

�_𝑅2=40/1.77

VR2: 207.491

Calculo de la velocidad teorica (garganta), v (cm/s): Tabla N°2. Resumen de datos TUBO VENTURI
�_𝑇2=√((2𝑔∗∆ℎ)/(1−( 〖𝐴 2/𝐴1) 〗 ^2 )) N° ∆h (cm)
1 22.5
2 19.5
VT2: 215.545 3 15.2
4 12.3
Calculo del coeficiente de velocidad 5 9.6
6 7
Cv: VR/VT 7 5
Cv: 0.9626356392 8 3.3
9 2.1
Calculo del numero del Reynolds, Re: 10 1

𝑅�=(𝐷∗�_𝑅)/�

Re2 = 311236.59605

Calculo delcoeficiente por perdida local, Kc

𝐾�=[(1/ 〖��〗 ^2 −1)(1−(𝐴_2/𝐴_1 )^2]


Kc : 0.0752

Calculo de perdidas pior contracción:

hc=Kc*(v^2/2g)
hc : 1.64998

Calculo del caudal teorico para el tubo de venturi

QT=VT*A
QT : 380.89870323 cm^3/s

Calculo del coeficiente de descarga Cd :


��=𝑄_𝑅/(𝐴_2 √2𝑔∆ℎ)

Cd : 0.9875489628

Calculo del coeficiente de perdida de carga en el medidor venturi

�_𝑖=ℎ_𝑝𝑖/∆ℎ

Ci : 0.32

Ecuación de Patronamiento para el tubo Venturi


𝑄=𝐾∆ℎ^�

k=Cd*A*(2g)^1/2
K: 74.02764027

𝑄=74.0276∆ℎ^0.5

Diafragma y medios Venturi

calculo de la velocidad teorica


�_𝑇=√((2𝑔∗∆ℎ)/(1−( 〖𝐴 3/𝐴1) 〗 ^2 ))

VT : 189.98433886 cm/s
Calculo de la velocidad real

VR: 116.71362493 cm/s

calculo del coeficiente de descarga Tabla N°3. Resultados de datos Diafragma


N° ∆h (cm)
Cd : 0.6692774725 1 15.5
2 13
Ecuacion de patronamiento 3 10.3
4 8.5
𝑄=𝐾∆ℎ^� 5 6.5
6 4.6
K: 93.133426467 7 3.4
8 2.1
𝑄=93.133∗∆ℎ^0.5 9 1.2
10 0.6

Tabla N° 4. perdidas para rotametro


N° hp (cm) VR (cm/s)
1 5.7 46.312
2 5.8 42.102
3 5.5 37.892
4 5.5 33.682
5 5.5 29.471
6 5.3 25.261
7 5.3 21.051
8 5.3 16.841
9 5.2 12.631
10 5 8.420
IAFRAGMA
h8 (cm)
9 20 L/min 366.6666666667
9
9
9.1
9.3
9.4
9.4
9.4
9.4
9.3

umen de datos TUBO VENTURI


hp (cm) VR (cm/s) VT (cm/s) Cv Re Kc hc (cm) QT (cm^3/s)
7.2 207.491 215.545 0.963 311236.596 0.075 1.650 380.899
6.5 188.628 200.661 0.940 598894.662 0.125 2.269 354.597
5.2 169.765 177.161 0.958 539005.196 0.085 1.243 313.069
4.8 150.903 159.367 0.947 479115.730 0.110 1.272 281.625
3.9 132.040 140.793 0.938 419226.263 0.130 1.157 248.802
3 113.177 120.225 0.941 359336.797 0.122 0.797 212.455
2.2 94.314 101.609 0.928 299447.331 0.153 0.692 179.557
1.5 75.451 82.547 0.914 239557.865 0.187 0.543 145.873
1.1 56.588 65.850 0.859 179668.399 0.336 0.549 116.366
0.7 37.726 45.441 0.830 119778.932 0.428 0.311 80.300
ultados de datos Diafragma
hp (cm) VR (cm/s) VT (cm/s) Cv Re Kc hc (cm) QT (cm^3/s)
10.5 116.714 189.984 0.614 233427.250 1.390 9.650 596.853
9 106.103 173.990 0.610 212206.591 1.423 8.165 546.605
7.3 95.493 154.871 0.617 190985.932 1.374 6.384 486.542
5.9 84.883 140.689 0.603 169765.273 1.472 5.406 441.989
4.2 74.272 123.029 0.604 148544.614 1.469 4.131 386.508
3 63.662 103.498 0.615 127323.954 1.384 2.860 325.148
2 53.052 88.980 0.596 106103.295 1.528 2.191 279.538
1.2 42.441 69.930 0.607 84882.636 1.445 1.326 219.691
0.7 31.831 52.862 0.602 63661.977 1.481 0.765 166.070
0.3 21.221 37.379 0.568 42441.318 1.772 0.407 117.430
Ci Cd
0.320 0.988
0.333 0.964
0.342 0.983
0.390 0.971
0.406 0.962
0.429 0.966
0.440 0.952
0.455 0.938
0.524 0.882
0.700 0.852
0.434 0.946
Ci Cd
0.677 0.669
0.692 0.664
0.709 0.672
0.694 0.657
0.646 0.658
0.652 0.670
0.588 0.650
0.571 0.661
0.583 0.656
0.500 0.618
0.631391 0.657573