Вы находитесь на странице: 1из 26

1.

1 Analysis of Sheet Pile Structure


1.1.1 Structural Model
Stress – deformation analysis is performed with PLAXIS a finite element computer
program (PLAXIS, B.V, 2013), and stiffness of structural element have been calculated as
follow.
1.1.1.1 Bored Pile
Bored pile is modelled into two elements, as a beam and node to node anchor elements,
in accordance to consider difference of lateral soil resistance at Row A and B. Stiffness of
bored pile is also reduced 50% to consider reducing in lateral soil resistance. Table 5.4.
shows stiffness of bored pile
Table Error! No text of specified style in document..1 Stiffness of bored pile

Structure Bored Pile


Diameter (m) 1.00
E (kPa) 2.00E+07
2
A (m ) 0.785
4
I (m ) 0.049
EA (kN) 1.57E+07
EI (kNm2) 9.82E+05
Space (m) 4.6
EA/space(kN/m) 3.41E+06
2
EI/space (kNm /m) 2.13E+05

EA/space (kN/m) x 50% 1.71E+06


INPUT PLAXIS
(Beam Element)
EI/space (kNm2/m) x 50% 1.07E+05

INPUT PLAXIS (Node to


EA (kN/m) x 50% 7.85E+06
Node Anchor Element)

1.1.1.2 Slab
Slab modelled as beam element and stiffness calculation is shown in Table 5.5. Stiffness
of Slab is also reduced 50% to consider Live load to be penetrated to Soil
Table Error! No text of specified style in document..2 Stiffness of Slab

Structure Slab
Thickness (m) 0.3
E (kPa) 2.00E+07
2
A (m ) 0.300
I (m4) 0.002
EA (kN) 6.00E+06
2
EI (kNm ) 4.50E+04
Space (m) 1
EA/space (kN/m) 6.00E+06
2
EI/space (kNm /m) 4.50E+04

EA/space(kN/m) x 50% 3.00E+06


INPUT
PLAXIS
EI/space(kNm2/m) x 50% 2.25E+04
1.1.1.3 Steel Sheet Pile
1.1.1.3.1 Initial Condition (Up to Installation in year 1993)
Sheet pile Larssen 32W was keep in storage for 20 years, before installation. Corrosion
rate at atmospheric zone 0.07 mm/year. So initial corrosion after 20 years storage = 20
years x 0.07 mm/year = 1.40 mm. (Refer to Scott-Wilson Documents “Matak Wharf Load
Restriction”)
1.1.1.3.2 Existing Condition
With reference to corrosion investigation report (ID-F-MA-CC0-PRT-JY-90-0001),
corrosion rate for each chainage 20 years after installation of sheet pile, the corrosion of
sheet pile summarize in Table 5.6.
Table Error! No text of specified style in document..3 Sheet pile corrosion rate

Corrosion Rate
(mm/year)
Zone Elevation
Bollard
1-4 4-9
Atmospheric 1.4 0.03 0.03
Splash 0.8 0.14 0.12
Tidal -0.6 0.11 0.09
Submerged - 0.07 0.07
Seabed - 0.03 0.03

Table Error! No text of specified style in document..4 Sheet pile capacity zone chainage 4 - 50

Larssen 32w Zone Chainage 4 -50


Zone Seabed Submerged Tidal Splash Atmospheric

Section Modulus Without


3216 3216 3216 3216 3216
Corrosion (cm3/m)

Moment Capacity Without


868 868 868 868 868
Corrosion (kNm/m)

Corrosion Rate(mm/year) 0.03 0.07 0.11 0.14 0.025


Age (year) after Installation 20 20 20 20 20

Corrosion rate x Age + Initial


2.00 2.78 3.59 4.18 1.90
Corrosion(mm)

Section Modulus After Corrosion


2840 2693 2542 2431 2859
(cm3/mm)
Cpacity Moment After
767 727 686 656 772
Corrosion(kNm/m)
Remaining (%) Capacity 88 84 79 76 89
Table Error! No text of specified style in document..5 Stiffness of sheet pile zone chainage 4 - 50

Larssen 32w Zone Chainage 4 -50

Zone Seabed Submerged Tidal Splash Atmospheric

E (kPa) 2.00E+08 2.00E+08 2.00E+08 2.00E+08 2.00E+08

A (m2) 0.0252 0.0252 0.0252 0.0252 0.0252

I (m4) 0.00070003 0.00070003 0.00070003 0.00070003 0.00070003

EA (kN) 5.04E+06 5.04E+06 5.04E+06 5.04E+06 5.04E+06

EI (kNm2) 1.40E+05 1.40E+05 1.40E+05 1.40E+05 1.40E+05

Remaining (%) Capacity 88 84 79 76 89


Remaining EA (kN/m) 4.45E+06 4.22E+06 3.98E+06 3.81E+06 4.48E+06
2
Remaining EI (kNm /m) 1.24E+05 1.17E+05 1.11E+05 1.06E+05 1.24E+05

Table Error! No text of specified style in document..6 Stiffness of sheet pile zone chainage 50 - 86

Larssen 32w Zone Chainage 50 - 86


Zone Seabed Submerged Tidal Splash Atmospheric

E (kPa) 2.00E+08 2.00E+08 2.00E+08 2.00E+08 2.00E+08

A (m2) 0.0252 0.0252 0.0252 0.0252 0.0252

I (m4) 0.00070003 0.00070003 0.00070003 0.00070003 0.00070003

EA (kN) 5.04E+06 5.04E+06 5.04E+06 5.04E+06 5.04E+06

EI (kNm2) 1.40E+05 1.40E+05 1.40E+05 1.40E+05 1.40E+05

Remaining (%) Capacity 88 84 79 76 89


Remaining EA (kN/m) 4.45E+06 4.22E+06 3.98E+06 3.81E+06 4.48E+06
Remaining EI (kNm2/m) 1.24E+05 1.17E+05 1.11E+05 1.06E+05 1.24E+05
Table Error! No text of specified style in document..7 Stiffness of sheet pile zone chainage 86 – 178.8

Larssen 32w Zone Chainage 86 - 178.8

Zone Seabed Submerged Tidal Splash Atmospheric

E (kPa) 2.00E+08 2.00E+08 2.00E+08 2.00E+08 2.00E+08

A (m2) 0.0252 0.0252 0.0252 0.0252 0.0252

I (m4) 0.00070003 0.00070003 0.00070003 0.00070003 0.00070003

EA (kN) 5.04E+06 5.04E+06 5.04E+06 5.04E+06 5.04E+06

EI (kNm2) 1.40E+05 1.40E+05 1.40E+05 1.40E+05 1.40E+05

Remaining (%) Capacity 88 84 81 78 89


Remaining EA (kN/m) 4.45E+06 4.22E+06 4.10E+06 3.95E+06 4.48E+06
2
Remaining EI (kNm /m) 1.24E+05 1.17E+05 1.14E+05 1.10E+05 1.24E+05

1.1.1.3.3 2023 Condition (Based on Design Life)


Corrosion rate for next 10 years (up to 2023) is based on Corrosion investigation report
(ID-F-MA-CC0-PRT-JY-90-0001). Bare condition and retrofitting condition are apply for
next 10 years. Its depends at the end of retrofitting construction schedule.
1.1.1.4 Deadman
Table Error! No text of specified style in document..8 Stiffness of deadman

Structure Deadman
Thickness (m) 6.00E-01
E (kPa) 2.00E+07
A (m2) 6.00E-01
4
I (m ) 1.80E-02
EA (kN) 1.20E+07
2
EI (kNm ) 3.60E+05
Space (m) 1.00E+00

EA/space (kN/m) 1.20E+07


2
EI/space (kNm /m) 3.60E+05

EA/space (kN/m) x 50% 6.00E+06


INPUT PLAXIS
(Beam Element)
EI/space (kNm2/m) x 50% 1.80E+05
1.1.1.5 UC350
Table Error! No text of specified style in document..9 Stiffness of UC350

UC350-Pile with Weight =137 kg/m actually


Structure
H-Beam 350.350.12.19

E (kPa) 2.00E+08
2
A (m ) 1.74E-02
4
I (m ) 1.36E-04
EA (kN) 3.48E+06
EI (kNm2) 2.72E+04
Space (m) 1.8
EA/space (kN/m) 1.93E+06
2
EI/space (kNm /m) 1.51E+04

EA/space (kN/m) x 50% 9.66E+05


INPUT PLAXIS
(Beam Element)
EI/space (kNm2/m) x 50% 7.56E+03

1.1.1.6 Steel Pipe Pile


Table Error! No text of specified style in document..10 Stiffness of steel pipe pile

Structure Steel Pipe Pile Zone 4 - 50, 86 -178.8


Outside Diamaeter (m) 5.08E-01
Thickness (m) 1.90E-02

Inside Diamaeter (m) 4.70E-01

A (m2) 2.92E-02
I (m4) 8.74E-04
E (kPa) 2.00E+08
EA (kN) 5.84E+06
2
EI (kNm ) 1.75E+05
Space (m) 4.00E+00
EA/space (kN/m) 1.46E+06
2
EI/space (kNm /m) 4.37E+04

EA/space (kN/m) x 50% 7.30E+05


INPUT PLAXIS
(Beam Element)
EI/space (kNm2/m) x 50% 2.18E+04
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 6 of 25

1.1.1.7 Tie Rod


Table Error! No text of specified style in document..11 Tie rod remaining capacity

Area Yield
Yield Yield Diameter Yield
Diameter Actual Corrosion Age of Corrosion at After at Working
Diameter Stress Working Year of After at Stress
Actual Area Rate Tie Rod Life Time Life Load % Remaining
(mm) of Steel Load Actual Installed Life Time of Steel
(mm) (mm2) (mm/year) (year) (mm) Time After Life
(N/mm) Area (kN) (mm) (N/mm)
(mm2) Time (kN)

(13) = (14) =
(1) (2) (3) (4) (5) = (3) x (4) (6) (7) (8) (9) (10) (11) (12)
(12) x (11) (13) x 100%/(5)

32 32 804.25 687 552.52 0.2 1993 20 8.0 24 452.39 687 310.79 56.25

36 36 1017.88 687 699.28 0.2 1993 20 8.0 28 615.75 687 423.02 60.49

40 34.4 929.41 432 401.50 0.2 1996 17 6.8 27.6 598.28 432 258.46 64.37

42 38.85 1185.42 432 512.10 0.2 1996 17 6.8 32.05 806.76 432 348.52 68.06

45 41.63 1361.14 432 588.01 0.2 1996 17 6.8 34.83 952.79 432 411.60 70.00

63.5 58.74 2709.93 555 1504.01 0.2 1996 17 6.8 51.94 2118.82 555 1175.94 78.19
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 7 of 25

1.1.2 Loading on Deck


1.1.2.1 Berthing Effect
1.1.3 Analysis Result
1.1.3.1 Model with berthing Load
Table 5.15 shows the resume of safety factor / unity check for model with berthing load in two
conditions, ultimate and service condition with two load cases for each zone.
Table Error! No text of specified style in document..12 Resume of safety factor / unity check for model with
berthing load

Safety Factor / Unity Chainage 4 - 50 Chainage 50 - 86 Chainage 86 - 178.8


No.
Check Load Case-1 Load Case-2 Load Case-1 Load Case-2 Load Case-1 Load Case-2
Ultimate Condition
SF Geotechnical
1 2 1.98 1.97 1.92 1.39 1.77
Stability
2 Unity Check Tie Rod Compression Compression Compression Compression Compression Compression
Unity Check of Old
3 Sheet Pile at 0.79 0.79 1.08 1.06 1.24 1.21
Submerged
Unity Check of Old
4 0.51 0.5 0.5 0.49 0.54 0.53
Sheet Pile at Tidal
Service Condition
1 Allowed SF for Tie Rod 2 2 2 2 2 2
2 SF Tie Rod Compression Compression Compression Compression 2.2 2.06
Allowed SF of Moment
3 Sheet Pile at 1.6 1.6 1.6 1.6 1.6 1.6
Submerged

SF of Old Sheet Pile at


4 1.64 1.64 2.06 2.01 2.53 2.55
Submerged
Allowed SF of Moment
5 1.6 1.6 1.6 1.6 1.6 1.6
Sheet Pile at Tidal
SF of Old Sheet Pile at
6 0.75 0.75 0.74 0.74 0.85 0.87
Tidal
Allowed SF
7 1.5 1.5 1.5 1.5 1.5 1.5
Geotechnical Stability
SF Geotechnical
8 2.51 2.46 2.35 2.4 2.07 1.8
Stability

1.1.3.1.1 Ultimate Condition


The analysis was conducted for 3 zone chainage, i.e., chainage 4 – 50, chainage 50 – 86,
and chainage 86 – 178.8. Tables below show the analysis result for load case-1 and load
case-2 for ultimate condition and safety factor. The minimum safety factor / unity check for
ultimate condition is 1, under 1 is considered fail (shown by grey mark).
Table Error! No text of specified style in document..13 Internal force on model with berthing load for ultimate
condition chainage 4 - 50

No. Chainage 4 - 50 Unit Condition


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 8 of 25

Ultimate Load Ultimate Load


Case-1 Case-2
1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 303 303


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 839.50 836.30
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 1226.00 1241.00
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686
Allowable Moment Capacity Old Sheet Pile at Tidal
11 kNm/m 624 624
= (10) / 1.1
12 Deformation Old Sheet Pile-Max cm -46.17 -45.96

Table Error! No text of specified style in document..14 Safety factor on model with berthing load for ultimate
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Ultimate Load Ultimate Load
Case-1 Case-2
1 SF Geotechnical Stability 2.00 1.98

2 Unity Check Tie Rod Compression Compression

3 Unity Check of Old Sheet Pile at Submerged 0.79 0.79

4 Unity Check of Old Sheet Pile at Tidal 0.51 0.50

Table Error! No text of specified style in document..15 Internal force on model with berthing load for ultimate
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Unit Ultimate Load Ultimate Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.55 1.55

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 436 436

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 396 396


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 614.10 624.00
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 9 of 25

Allowable Moment Capacity Old Sheet Pile at


8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 1246.00 1266.00
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686
Allowable Moment Capacity Old Sheet Pile at Tidal
11 kNm/m 624 624
= (10) / 1.1
12 Deformation Old Sheet Pile-Max cm -40.09 -40.03
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 10 of 25

Table Error! No text of specified style in document..16 Safety factor on model with berthing load for ultimate
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Ultimate Load Ultimate Load
Case-1 Case-2
1 SF Geotechnical Stability 1.97 1.92

2 Unity Check Tie Rod Compression Compression

3 Unity Check of Old Sheet Pile at Submerged 1.08 1.06

4 Unity Check of Old Sheet Pile at Tidal 0.50 0.49

Table Error! No text of specified style in document..17 Internal force on model with berthing load for ultimate
condition chainage 86 – 178.8

Condition
No. Chainage 86 - 178.8 Unit Ultimate Load Ultimate Load
Case-1 Case-2
1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.23 1.23

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 350 350

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 318 318


Max Bending Moment Old Sheet Pile PLAXIS output
6 kNm/m 535.30 548.20
at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS output
9 kNm/m 1184.00 1205.00
at Tidal

10 Moment Capacity Old Sheet Pile at Tidal kNm/m 707 707


Allowable Moment Capacity Old Sheet Pile at Tidal =
11 kNm/m 643 643
(10) / 1.1
12 Deformation Old Sheet Pile-Max cm -15.81 -15.7

Table Error! No text of specified style in document..18 Safety factor on model with berthing load for ultimate
condition chainage 86 – 178.8

Condition
No. Chainage 86 - 178.8 Ultimate Load Ultimate Load
Case-1 Case-2

1 SF Geotechnical Stability 1.39 1.77

2 Unity Check Tie Rod Compression Compression

3 Unity Check of Old Sheet Pile at Submerged 1.24 1.21

4 Unity Check of Old Sheet Pile at Tidal 0.54 0.53


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 11 of 25

1.1.3.1.2 Service Condition


The analysis was conducted for 3 zone chainage, i.e., chainage 4 – 50, chainage 50 – 86,
and chainage 86 – 178.8. Tables below show the analysis result for load case-1 and load
case-2 for service condition and the safety factors. The allowable safety factor is represented
in the table, safety factor below the allowed SF is shown by the grey mark.
Table Error! No text of specified style in document..19 Internal force on model with berthing load for service
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod kN 167 167


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 442.70 444.00
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727

Allowable Moment Capacity Old Sheet Pile at


8 kNm/m 455 455
Submerged

Max Bending Moment Old Sheet Pile PLAXIS


9 kNm/m 910.00 916.50
output at Tidal

10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 429 429
12 Deformation Old Sheet Pile-Max cm -25.33 -25.05

Table Error! No text of specified style in document..20 Safety factor on model with berthing load for service
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Service Load Service Load
Case-1 Case-2

1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod Compression Compression


3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6
4 SF of Old Sheet Pile at Submerged 1.64 1.64
5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6
6 SF of Old Sheet Pile at Tidal 0.75 0.75
7 Allowed SF Geotechnical Stability 1.50 1.50
8 SF Geotechnical Stability 2.51 2.47

Table Error! No text of specified style in document..21 Internal force on model with berthing load for service
condition chainage 50 - 86

No. Chainage 50 - 86 Unit Condition


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 12 of 25

Service Load Service Load


Case-1 Case-2

1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.55 1.55

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 436 436

5 Allowable Capacity of Tie Rod kN 218 218


Max Bending Moment Old Sheet Pile PLAXIS output
6 kNm/m 353.60 361.70
at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS output
9 kNm/m 921.30 927.60
at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 429 429

12 Deformation Old Sheet Pile-Max cm -24.01 -23.71

Table Error! No text of specified style in document..22 Safety factor on model with berthing load for service
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Service Load Service Load
Case-1 Case-2

1 Allowed SF for Tie Rod 2 2


2 SF Tie Rod Compression Compression
3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6
4 SF of Old Sheet Pile at Submerged 2.06 2.01
5 Allowed SF of Moment Sheet Pile at Tidal+H29 1.6 1.6
6 SF of Old Sheet Pile at Tidal 0.74 0.74
7 Allowed SF Geotechnical Stability 1.50 1.50
8 SF Geotechnical Stability 2.36 2.40

Table Error! No text of specified style in document..23 Internal force on model with berthing load for service
condition chainage 86 – 178.8

Condition
No. Chainage 86 – 178.8 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 129.00 138.32

2 Space m 1.23 1.23

3 Tie Force PLAXIS Output x Spacing kN 158.61 170.06

4 Yield Capacity of Tie Rod kN 350 350

5 Allowable Capacity of Tie Rod kN 175 175


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 13 of 25

Condition
No. Chainage 86 – 178.8 Unit Service Load Service Load
Case-1 Case-2
Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 287.50 285.10
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 829.50 812.60
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 707 707

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 442 442

12 Deformation Old Sheet Pile-Max cm -9.018 -8.701

Table Error! No text of specified style in document..24 Safety factor on model with berthing load for service
condition chainage 86 – 178.8

Condition
No. Chainage 86 – 178.8 Service Load Service Load
Case-1 Case-2
1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 2.20 2.06

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6

4 SF of Old Sheet Pile at Submerged 2.53 2.55

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 0.85 0.87

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 2.07 1.80

1.1.3.2 Model without berthing Load


Table 5.28 shows the resume of safety factor / unity check for model without berthing load in
two conditions, ultimate and service condition with two load cases for each zone.
Table Error! No text of specified style in document..25 Resume of safety factor / unity check for model without
berthing load

Safety Factor / Unity Chainage 4 - 50 Chainage 50 - 86 Chainage 86 - 178.8


No.
Check Load Case-1 Load Case-2 Load Case-1 Load Case-2 Load Case-1 Load Case-2
Ultimate Condition
SF Geotechnical
1 1.39 1.41 1.4 1.44 1.48 1.54
Stability
2 Unity Check Tie Rod 1.87 1.6 1.53 1.43 0.89 0.89
Unity Check of Old
3 Sheet Pile at 1.13 1.04 1.27 1.13 1.14 1.08
Submerged
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 14 of 25

Safety Factor / Unity Chainage 4 - 50 Chainage 50 - 86 Chainage 86 - 178.8


No.
Check Load Case-1 Load Case-2 Load Case-1 Load Case-2 Load Case-1 Load Case-2
Unity Check of Old
4 55.65 52.29 25.01 26.41 13.43 13.69
Sheet Pile at Tidal
Service Condition
1 Allowed SF for Tie Rod 2 2 2 2 2 2
2 SF Tie Rod 2.31 2.2 1.87 1.81 0.94 0.92
Allowed SF of Moment
3 Sheet Pile at 1.6 1.6 1.6 1.6 1.6 1.6
Submerged
SF of Old Sheet Pile at
4 2.01 1.94 2.35 2.22 2.44 2.37
Submerged
Allowed SF of Moment
5 1.6 1.6 1.6 1.6 1.6 1.6
Sheet Pile at Tidal
SF of Old Sheet Pile at
6 31.09 31.71 24.85 25.58 12.45 11.9
Tidal
Allowed SF
7 1.5 1.5 1.5 1.5 1.5 1.5
Geotechnical Stability
SF Geotechnical
8 1.81 1.81 1.66 1.64 1.78 1.85
Stability

1.1.3.2.1 Ultimate Condition


The analysis was conducted for 3 zone chainage, i.e., chainage 4 – 50, chainage 50 – 86,
and chainage 86 – 178.8. Tables below show the analysis result for load case-1 and load
case-2 for ultimate condition and safety factor. The minimum safety factor / unity check for
ultimate condition is 1, under 1 is considered fail (shown by grey mark).
Table Error! No text of specified style in document..26 Internal force on model without berthing load for ultimate
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Ultimate Load Ultimate Load
Unit
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 156.31 182.19

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN 162.60 189.52

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 303 303


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 585 634.20
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 11.21 11.93
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686
Allowable Moment Capacity Old Sheet Pile at Tidal
11 kNm/m 624 624
= (10) / 1.1
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 15 of 25

12 Deformation Old Sheet Pile-Max cm 13.22 16.54

Table Error! No text of specified style in document..27 Safety factor on model without berthing load for ultimate
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Ultimate Load Ultimate Load
Case-1 Case-2

1 SF Geotechnical Stability 1.39 1.41

2 Unity Check Tie Rod 1.87 1.60

3 Unity Check of Old Sheet Pile at Submerged 1.13 1.04

4 Unity Check of Old Sheet Pile at Tidal 55.65 52.29


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 16 of 25

Table Error! No text of specified style in document..28 Internal force on model without berthing load for ultimate
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Ultimate Load Ultimate Load
Unit
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 166.46 178.75

2 Space m 1.55 1.55

3 Tie Force PLAXIS Output x Spacing kN 258.66 277.76

4 Yield Capacity of Tie Rod kN 436 436

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 396 396


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 519 584.90
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 24.94 23.62
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686
Allowable Moment Capacity Old Sheet Pile at Tidal
11 kNm/m 624 624
= (10) / 1.1
12 Deformation Old Sheet Pile-Max cm 12.07 16.23

Table Error! No text of specified style in document..29 Safety factor on model without berthing load for ultimate
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Ultimate Load Ultimate Load
Case-1 Case-2
1 SF Geotechnical Stability 1.40 1.44

2 Unity Check Tie Rod 1.53 1.43

3 Unity Check of Old Sheet Pile at Submerged 1.27 1.13

4 Unity Check of Old Sheet Pile at Tidal 25.01 26.41

Table Error! No text of specified style in document..30 Internal force on model without berthing load for ultimate
condition chainage 86 – 178.8

Condition
No. Chainage 86 - 178.8 Ultimate Load Ultimate Load
Unit
Case-1 Case-2
1 Tie Force PLAXIS Output kN/m 291.29 290.33

2 Space m 1.23 1.23

3 Tie Force PLAXIS Output x Spacing kN 358.14 356.96

4 Yield Capacity of Tie Rod kN 350 350

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 318 318

Max Bending Moment Old Sheet Pile PLAXIS


6 kNm/m 578 613
output at Submerged
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 17 of 25

Condition
No. Chainage 86 - 178.8 Ultimate Load Ultimate Load
Unit
Case-1 Case-2
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 48 47
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 707 707
Allowable Moment Capacity Old Sheet Pile at Tidal
11 kNm/m 643 643
= (10) / 1.1
12 Deformation Old Sheet Pile-Max cm 7.913 10.24

Table Error! No text of specified style in document..31 Safety factor on model without berthing load for ultimate
condition chainage 86 – 178.8

Condition
No. Chainage 86 – 178.8 Ultimate Load Ultimate Load
Case-1 Case-2
1 SF Geotechnical Stability 1.48 1.54

2 Unity Check Tie Rod 0.89 0.89

3 Unity Check of Old Sheet Pile at Submerged 1.14 1.08

4 Unity Check of Old Sheet Pile at Tidal 13.43 13.69

1.1.3.2.2 Service Condition


The analysis was conducted for 3 zone chainage, i.e., chainage 4 – 50, chainage 50 – 86,
and chainage 86 – 178.8. Tables below show the analysis result for load case-1 and load
case-2 for service condition and the safety factors. The allowable safety factor is represented
in the table, safety factor below the allowed SF is shown by the grey mark.
Table Error! No text of specified style in document..32 Internal force on model without berthing load for service
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 138.64 145.79

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN 144.21 151.66

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod kN 167 167


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 361.40 374.20
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 22.07 21.64
output at Tidal
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 18 of 25

10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 429 429

12 Deformation Old Sheet Pile-Max cm 3.146 4.128


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 19 of 25

Table Error! No text of specified style in document..33 Safety factor on model without berthing load for service
condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Service Load Service Load
Case-1 Case-2
1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 2.31 2.20

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6

4 SF of Old Sheet Pile at Submerged 2.01 1.94

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 31 32

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 1.81 1.81

Table Error! No text of specified style in document..34 Internal force on model without berthing load for service
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 150.18 154.77

2 Space m 1.55 1.55

3 Tie Force PLAXIS Output x Spacing kN 233.37 240.50

4 Yield Capacity of Tie Rod kN 436 436

5 Allowable Capacity of Tie Rod kN 218 218


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 309.80 327.70
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 27.61 26.83
output at Tidal

10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 429 429

12 Deformation Old Sheet Pile-Max cm 4.119 5.224


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 20 of 25

Table Error! No text of specified style in document..35 Safety factor on model without berthing load for service
condition chainage 50 - 86

Condition
No. Chainage 50 - 86 Service Load Service Load
Case-1 Case-2
1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 1.87 1.81

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6

4 SF of Old Sheet Pile at Submerged 2.35 2.22

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 25 26

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 1.66 1.64

Table Error! No text of specified style in document..36 Internal force on model without berthing load for service
condition chainage 86 – 178.8

Condition
No. Chainage 86 - 178.8 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 301.49 307.66

2 Space m 1.23 1.23

3 Tie Force PLAXIS Output x Spacing kN 370.68 378.27

4 Yield Capacity of Tie Rod kN 350 350

5 Allowable Capacity of Tie Rod kN 175 175


Max Bending Moment Old Sheet Pile PLAXIS
6 kNm/m 298.50 307.00
output at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS
9 kNm/m 56.79 59.43
output at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 707 707

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 442 442

12 Deformation Old Sheet Pile-Max cm 2.494 3.168


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 21 of 25

Table Error! No text of specified style in document..37 Safety factor on model without berthing load for service
condition chainage 86 – 178.8

Condition
No. Chainage 86 - 178.8 Service Load Service Load
Case-1 Case-2
1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 0.94 0.92

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6

4 SF of Old Sheet Pile at Submerged 2.44 2.37

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 12 12

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 1.78 1.85

1.1.3.3 Model with berthing load (SF = 1), to determine Max berthing load allowed
1.1.3.3.1 Model with berthing load at Tie rod elevation (SF = 1), to determine Max berthing load
allowed for existing condition (2013)
Table 5.41 and Table 5.42 shows the analysis result to determine the maximum berthing
load allowed for existing condition on chainage 4 – 50 with the applied berthing load of 750
kN/m for ultimate condition.
Table Error! No text of specified style in document..38 Internal force on model with berthing load at tie rod
elevation for ultimate condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Ultimate Load Ultimate Load
Case-1 Case-2
1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 303 303


Max Bending Moment Old Sheet Pile PLAXIS output at
6 kNm/m 560.60 588.00
Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 661 661
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS output at
9 kNm/m 620 625
Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686
Allowable Moment Capacity Old Sheet Pile at Tidal =
11 kNm/m 624 624
(10) / 1.1
12 Deformation Old Sheet Pile-Max cm -16.68 -16.74
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 22 of 25
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 23 of 25

Table Error! No text of specified style in document..39 Safety factor on model with berthing load at tie rod
elevation for ultimate condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Ultimate Load Ultimate Load
Case-1 Case-2

1 SF Geotechnical Stability 2.21 2.14

2 Unity Check Tie Rod Compression Compression

3 Unity Check of Old Sheet Pile at Submerged 1.18 1.12

4 Unity Check of Old Sheet Pile at Tidal 1.01 1.00

Table 5.43 and Table 5.44 shows the analysis result to determine the maximum berthing
load allowed for existing condition on chainage 4 – 50 with the applied berthing load of 480
kN/m for service condition.
Table Error! No text of specified style in document..40 Internal force on model with berthing load at tie rod
elevation for service condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 44.09 47.28

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN 45.86 49.18

4 Yield Capacity of Tie Rod kN 334 334

5 Allowable Capacity of Tie Rod kN 167 167


Max Bending Moment Old Sheet Pile PLAXIS output
6 kNm/m 366.80 372.70
at Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 727 727
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 455 455
Submerged
Max Bending Moment Old Sheet Pile PLAXIS output
9 kNm/m 425 424
at Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 686 686

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 429 429

12 Deformation Old Sheet Pile-Max cm -9.967 -9.595


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 24 of 25

Table Error! No text of specified style in document..41 Safety factor on model with berthing load at tie rod
elevation for service condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Service Load Service Load
Case-1 Case-2
1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 7.28 6.78

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6

4 SF of Old Sheet Pile at Submerged 1.98 1.95

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 1.62 1.62

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 2.50 2.78

1.1.3.3.2 Model with berthing load at LWL elevation (SF = 1), to determine Max berthing load
allowed until 2017
Table 5.45 and Table 5.46 shows the analysis result to determine the maximum berthing
load allowed until 2017 on chainage 4 – 50 with the applied berthing load of 720 kN/m for
ultimate condition.
Table Error! No text of specified style in document..42 Internal force on model with berthing load at LWL
elevation for ultimate condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Ultimate Load Ultimate Load
Case-1 Case-2
1 Tie Force PLAXIS Output kN/m Compression Compression

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN Compression Compression

4 Yield Capacity of Tie Rod kN 298 298

5 Allowable Capacity of Tie Rod = (4) / 1.1 kN 271 271

Max Bending Moment Old Sheet Pile PLAXIS output at


6 kNm/m 548 580
Submerged
7 Moment Capacity Old Sheet Pile at Submerged kNm/m 713 713
Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 648 648
Submerged = (7) / 1.1
Max Bending Moment Old Sheet Pile PLAXIS output at
9 kNm/m 602 607
Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 664 664
Allowable Moment Capacity Old Sheet Pile at Tidal =
11 kNm/m 604 604
(10) / 1.1
12 Deformation Old Sheet Pile-Max cm -15.88 -16.02
Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 25 of 25

Table Error! No text of specified style in document..43 Safety factor on model with berthing load at LWL
elevation for ultimate condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Ultimate Load Ultimate Load
Case-1 Case-2

1 SF Geotechnical Stability 2.16 2.08

2 Unity Check Tie Rod Compression Compression

3 Unity Check of Old Sheet Pile at Submerged 1.18 1.12

4 Unity Check of Old Sheet Pile at Tidal 1.00 0.99

Table 5.47 and Table 5.48 shows the analysis result to determine the maximum berthing
load allowed until 2017 on chainage 4 – 50 with the applied berthing load of 460 kN/m for
service condition.
Table Error! No text of specified style in document..44 Internal force on model with berthing load at LWL
elevation for service condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Unit Service Load Service Load
Case-1 Case-2

1 Tie Force PLAXIS Output kN/m 51.20 54.87

2 Space m 1.04 1.04

3 Tie Force PLAXIS Output x Spacing kN 53.26 57.08

4 Yield Capacity of Tie Rod kN 298 298

5 Allowable Capacity of Tie Rod kN 149 149

Max Bending Moment Old Sheet Pile PLAXIS output at


6 kNm/m 363.40 377.00
Submerged

7 Moment Capacity Old Sheet Pile at Submerged kNm/m 713 713


Allowable Moment Capacity Old Sheet Pile at
8 kNm/m 446 446
Submerged
Max Bending Moment Old Sheet Pile PLAXIS output at
9 kNm/m 411.90 408.00
Tidal
10 Moment Capacity Old Sheet Pile at Tidal kNm/m 664 664

11 Allowable Moment Capacity Old Sheet Pile at Tidal kNm/m 415 415

12 Deformation Old Sheet Pile-Max cm -9.271 -9.071

Table Error! No text of specified style in document..45 Safety factor on model with berthing load at LWL
elevation for service condition chainage 4 - 50

Condition
No. Chainage 4 - 50 Service Load Service Load
Case-1 Case-2

1 Allowed SF for Tie Rod 2 2

2 SF Tie Rod 5.59 5.22

3 Allowed SF of Moment Sheet Pile at Submerged 1.6 1.6


Design Criteria ID-F-MA-CC0-DRT-JY-90-0001 Rev. 0B
Matak Jetty Integrity
ConocoPhillips Indonesia Inc. Ltd Page 26 of 26

Condition
No. Chainage 4 - 50 Service Load Service Load
Case-1 Case-2

4 SF of Old Sheet Pile at Submerged 1.96 1.89

5 Allowed SF of Moment Sheet Pile at Tidal 1.6 1.6

6 SF of Old Sheet Pile at Tidal 1.61 1.63

7 Allowed SF Geotechnical Stability 1.50 1.50

8 SF Geotechnical Stability 2.75 2.64