All diamond lath should be installed in a horizontal position with
deformations in the lath directed upward. Improper installation can cause cracking. All lath must be lapped a minimum of 1/2 in. on side laps and 2 in. on end laps. When paper-backed lath is employed, the paper must be removed from one piece of lath to permit a paper-to-paper and lath-to-lath configuration in the lapped area. Improper application will cause cracking. All lath must be discontinued at control joints. A minimum 1/2-in. gap is desirable. Improper installation. If the lath is not discontinued, the joint will not function and can result in cracking. A 1/4-in. gap should be provided between all sheets of plywood. Building paper and self-furring lath or paper-backed lath should be installed. Plywood should be covered in storage and covered with building paper when applied to the structure to prevent wetting. Proper nailing is important.
Cracking can occur in a plaster membrane due to expansion of plywood sheathing.