TYPE OF AREAS OF APPROVED

WATERPROOFING APPLICATION BRANDS

 Cementtitious/ Potable Water Tanks, Reservoirs, Vandex, Xypex


Capillary/ Sump pit, Elevator pit, Basement or equal
Crystallization type interior walls (Negative application)

 Elastomeric Fluid Areas above or below grade where Neogard-Permagard,


Applied type concrete topping is required with or Hyflex, Finflex or equal
without surface finishes: Roof Decks,
Swimming Pools, Ponds, Balconies,
Terraces, Planterboxes, T&Bs,
Basement Walls (positive application)
And slabs, Retaining walls, Plaza decks,
Parking decks, Firewall

 Elastomeric, Roll/ Areas above or below grade where


Sheet type concrete topping is required with or
without surface finishes: Roof Decks,
Swimming Pools, Ponds, Balconies,
Terraces, T&Bs, ,Plaza decks,
Parking decks

 Geomembrane Roll/ Basement Walls (positive application) Volclay Swelltite or equal


Sheet type and slabs, Retaining walls

 Bentonite Geotextile Below grade horizontal and vertical Voltex or equal


Surfaces, such as underslab and
Property line or blind-side
waterproofing, metal sheet piling,
Concrete caisson construction

 Surface applied liquid Exposed type for Roof Decks, carpark Neogard-Autogard or
Type coating/ decks, Parking Ramps equal
waterproofing
SCHEDULE OF WATERPROOFING

I. SUB-STRUCTURE

A. Basement Perimeter Walls Capillary/cementitious type, negative application

or Below Grade Concrete


Walls

B. Retaining walls Capillary/cementitious type, negative application

C. Sump pits, Elevator pits Capillary/cementitious type, negative application

D. RC Water Tanks Capillary/cementitious type, negative application;


Apply before epoxy tank lining coating

E. Cistern Tank Capillary/cementitious type, negative application

F. Ramp Down (from Ground floor) Elastomeric waterproofing, cold-applied, liquid type
concealed application before installation of non-skid
tiles; Apply from Ground floor ramp down to steel
trench grating

G. Plantboxes/Tree pits Elastomeric waterproofing, cold-applied, liquid type;


Apply before installation of “Nordrain” system

H. Basement Floors’ Toilets/ Elastomeric waterproofing, cold-applied, liquid type;


Grnd. Flr. Male & Female concealed application before installation of Toilet
Toilets floor tiles

I. Ground Floor Hardscape/ Elastomeric waterproofing, cold-applied, liquid type;


Landscape areas concealed application before installation of paving
materials

II. WEST TOWER (Superstructure)

A. Upper Floors’ Toilets Elastomeric waterproofing, cold-applied, liquid type;


(including Residential units’ concealed application before installation of Toilet
T&Bs) floor tiles

B. Residential Units-Kitchen/ Elastomeric waterproofing, cold-applied, liquid type;


Washer-Dryer areas concealed application before installation of floor tiles

C. Balconies Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of floor tiles

D. Swimming Pool Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of pool tiles

E. Pool Deck Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of
deck or paver tiles

F. RC Water Tanks Capillary/cementitious type, negative application;


Apply before epoxy tank lining coating

G. Decks/Roof Decks Elastomeric waterproofing, cold-applied, liquid type;


(with foot traffic) concealed application before installation of floor or
paver or finish tiles.

H. Roof Slab/Roof Decks Elastomeric waterproofing, cold-applied, liquid type;


(without foot traffic) exposed application

I. Other areas requiring wet Elastomeric waterproofing, cold-applied, liquid type;


activities concealed application before installation of floor tiles

III. EAST TOWER (Superstructure)

A. Upper Floors’ Toilets Elastomeric waterproofing, cold-applied, liquid type;


(including Residential units’ concealed application before installation of Toilet
T&Bs) floor tiles

B. Residential Units-Kitchen/ Elastomeric waterproofing, cold-applied, liquid type;


Washer-Dryer areas concealed application before installation of floor tiles

C. Balconies Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of floor tiles

D. Swimming Pool Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of pool tiles

E. Pool Deck Elastomeric waterproofing, cold-applied, liquid type;


concealed application before installation of
deck or paver tiles

F. Domestic Water & Fire Water Capillary/cementitious type, negative application;


Storage Tanks Apply before epoxy tank lining coating

G. Decks/Roof Decks Elastomeric waterproofing, cold-applied, liquid type;


(with foot traffic) concealed application before installation of floor or
paver or finish tiles.

H. Roof Slab/Roof Decks Elastomeric waterproofing, cold-applied, liquid type;


(without foot traffic) exposed application

I. Other areas requiring wet Elastomeric waterproofing, cold-applied, liquid type;


activities concealed application before installation of floor tiles