Вы находитесь на странице: 1из 4

AIRCRAFT

MAINTENANCE MANUAL

HIGH-STAGE BLEED VALVE - INSPECTION/CHECK

EFFECTIVITY: ALL

1. General
A. This task gives the procedure to do the visual inspection of the high-stage bleed-valve filter.

B. The high-stage bleed-valves are installed in the LH and RH bleed ducting on the outboard side of
the engines.

C. There is one high-stage bleed-valve filter in each high-stage bleed-valve.

D. The procedures in this section are given in the sequence below.

TASK NUMBER DESCRIPTION EFFECTIVITY

High-Stage Bleed-Valve Filter - General


36-11-01-210-801-A ALL
Visual Inspection

Embraer 190 - AMM 3914 General


36-11-01 Page 1 of 4
Rev 1 - Jul 15/10
Copyright © 2010 by Embraer - Empresa Brasileira de Aeronáutica S.A. All rights reserved.
AIRCRAFT
MAINTENANCE MANUAL

TASK 36-11-01-210-801-A
EFFECTIVITY: ALL

2. High-Stage Bleed-Valve Filter - General Visual Inspection


A. General

(1) This task gives the procedure to do the visual inspection of the high-stage bleed-valve filter.

(2) This maintenance technician is necessary to do this task:


• 1 - Mechanical Systems

B. References

REFERENCE DESIGNATION

Aircraft Maintenance Safety Procedures - Standard


AMM TASK 20-00-00-910-801-A/200
Procedures
AMM TASK 36-11-01-000-802-A/400 High-Stage Bleed-Valve Filter - Removal
High-Stage Bleed-Valve Filter - Cleaning (ultrasonic
AMM TASK 36-11-01-130-801-A/700
method)
AMM TASK 36-11-01-400-802-A/400 High-Stage Bleed-Valve Filter - Installation
AMM TASK 71-00-00-910-801-A/200 Powerplant - Maintenance Practices

C. Job Set-Up
WARNING: MAKE SURE THAT THE AIRCRAFT IS IN A SAFE CONDITION BEFORE YOU DO THE
MAINTENANCE PROCEDURES. THIS IS TO PREVENT INJURY TO PERSONS AND/
OR DAMAGE TO THE EQUIPMENT.

WARNING: DO NOT TOUCH THE DUCTS OR COMPONENTS OF THE AIR BLEED SYSTEM
IMMEDIATELY AFTER THE SYSTEM STOPS ITS OPERATION. THE HIGH AIR
TEMPERATURE CAN CAUSE INJURY TO PERSONS.

WARNING: MAKE SURE THAT AN ACCIDENTAL OPERATION OF THE FLIGHT CONTROL


SURFACES, LANDING GEAR SYSTEM, AND ANTI-ICING SYSTEM DOES NOT
OCCUR. AN ACCIDENTAL OPERATION OF ONE OF THEM CAN CAUSE INJURY TO
PERSONS.
SUBTASK 940-001-A
(1) Do the procedure to make the aircraft safe for maintenance (AMM TASK
20-00-00-910-801-A/200 ).

(2) Do the procedure to make the aircraft safe for maintenance of the powerplant (AMM
TASK 71-00-00-910-801-A/200 ).
SUBTASK 020-001-A
(3) Remove the high-stage bleed-valve filter (AMM TASK 36-11-01-000-802-A/400 ).

Embraer 190 - AMM 3914 210-801-A/600


36-11-01 Page 2 of 4
Rev 1 - Jul 15/10
Copyright © 2010 by Embraer - Empresa Brasileira de Aeronáutica S.A. All rights reserved.
AIRCRAFT
MAINTENANCE MANUAL

D. High-Stage Bleed-Valve Filter - Visual Inspection


SUBTASK 212-001-A
(1) Do a visual inspection of the high-stage bleed-valve filter for signs of wear, nicks, dents
and other damage..

(2) Do a check of the internal passages to be sure that they are clean and not blocked.
NOTE: Do the cleaning procedure of the high-stage bleed-valve filter (AMM TASK
36-11-01-130-801-A/700 ) if the filter is dirty and/or blocked.

(3) Do a check of the threads for rough edges and defects. Make sure that the threaded
fits are satisfactory.

(4) If the filter is not in good conditions, you must replace it (AMM TASK
36-11-01-000-802-A/400 /AMM TASK 36-11-01-400-802-A/400 ).
E. Job Close-Up
SUBTASK 420-001-A
(1) Install the high-stage bleed-valve filter (AMM TASK 36-11-01-400-802-A/400 ).

Embraer 190 - AMM 3914 210-801-A/600


36-11-01 Page 3 of 4
Rev 1 - Jul 15/10
Copyright © 2010 by Embraer - Empresa Brasileira de Aeronáutica S.A. All rights reserved.
AIRCRAFT
MAINTENANCE MANUAL

EFFECTIVITY: ALL
High-Stage Bleed-Valve Filter - Component Location
Figure 601

PACKING

FILTER

SERVO LINE
LOCKWIRE HPRSOV
EM170MPP360146A.DGN

Embraer 190 - AMM 3914 210-801-A/600


36-11-01 Page 4 of 4
Rev 1 - Jul 15/10
Copyright © 2010 by Embraer - Empresa Brasileira de Aeronáutica S.A. All rights reserved.

Вам также может понравиться