AIR DRIES, NO HEAT CURING REQUIRED HIGH PERFORMANCE INDUSTRIAL HEAT RESISTANT COATING *Maximum Service Temperature 500ºF (260ºC)
CHARACTERISTICS: * Heat Resistance of Standard Colors:
DESCRIPTION: Finish. . . . . . . .. . . . . . . . . . . . . (*) Gloss No. 1 Black . . . . . . Up to 500ºF (260ºC) TemperKote No. 500 High No. 2 Silver. . . . . . . Up to 500ºF (260ºC) Performance Heat Resistant Coatings Resin Type. . . . . . . Modified epoxy ester *No. 3 Lagoon . . . . . Up to 200ºF ( 93ºC) are based on a one component *No. 4 Topaz . . . . . . Up to 250ºF (121ºC) Primer. . . . . . . . . . . . . . . Phenolic Alkyd *No. 5 Horizon . . . . . Up to 200ºF ( 93ºC) specially modified epoxy ester resin. Type of Cure. . . . . . Solvent evaporation/ *No. 6 Newport . . . . Up to 250ºF (121ºC) The coatings air dry by polymerization oxidation *No. 7 Mauve . . . . . . Up to 200ºF ( 93ºC) and oxidation to form a tough, No. 8 Walnut . . . . . Up to 500ºF (260ºC) durable, heat, chemical, and moisture Drying Time @ 77ºF (25ºC) & 50% *No. 9 Fawn . . . . . . . Up to 200ºF ( 93ºC) R.H. vapor resistant film. They do not *No.10 Russet . . . . . Up to 400ºF (204ºC) (:) To touch. . . . . . . . . . . . . . . . . . . ½ hour require any complex heat-curing (:) To recoat . . . . . . . . . . . . . ½ - 1 ½ hours *No.11 Quarry . . . . . Up to 200ºF ( 93ºC) schedule to obtain their heat resistant If recoating cannot be done within that *No.12 Camouflage . Up to 350ºF (177ºC) properties. time, allow to cure for 7 days before *No. 13 Dusty . . . . . Up to 200ºF ( 93ºC) recoating. *No. 14 Golden . . . . Up to 350ºF (177ºC) *No. 15 Charcoal . . . Up to 450ºF (232ºC) No. 500 Series coatings are also Curing Temperature & Time *No. 16 Steel . . . . . . Up to 200ºF ( 93ºC) suitable for use on stainless steel Minimum curing *No. 17 Pewter . . . . . Up to 200ºF ( 93ºC) surfaces; they are formulated with temperature. . . . . . . . . . . . . . . 50ºF (10ºC) *No. 18 White . . . . . Up to 200ºF ( 93ºC) special ingredients to minimize Minimum curing Primer . . . . . . . . . . . . Up to 500ºF (260ºC) contamination from chlorides, other time . . . . . . . . . . . . . . . . N/A (See drying halides, sulfides, nitrates and metals time above) *NOTE: All standard colors will withstand dry which are known to induce external service temperatures up to 500ºF (260ºC). Application Temperature . . . . . . . . . . . . However, the temperature listed for each color stress corrosion cracking. They 50ºF (10ºC) to (:) 150ºF (66ºC) indicates the maximum temperature that color contain no free metallic zinc and, will withstand, with minimal color change. Spreading Rate therefore, will not contribute to Above the temperature shown, a significant Per Coat . . . . . . . . . . . 420-560 sq.ft./gal. color change will occur. This color change is embrittlement of stainless steel welds. (10.3-13.7 m2L) not reversible. 2.9-3.8 mils wet, 1-1.3 mils dry RECOMMENDED USES: Solids by Weight . . . . . Varies with color SURFACE PREPARTION: Wherever resistance to heat, humidity Solids by Volume . . . . . Varies with color and corrosive atmospheric conditions Weight Per Gallon . . . . Varies with color STEEL: Sandblast or mechanically is required. Can be used as a wire brush surface. Remove all protective and decorative coating on Flash Point contaminants. i.e. rust, grease, wax, of Liquid Coating . . . . . . . 80ºF (26.6ºC) oil, mill scale, etc. See application metal parts, mufflers, hot water and (closed cup) steam lines, where operating below for primers. A low profile temperatures will not exceed 500ºF Reducer/Cleaner . . . . . . Xylol or Xylene sandblasted surface will give best (260ºC). Not recommended for use Shelf Life . . . . . . . . . . 2 years (unopened) results, especially where the higher on the inside of ovens, stacks, etc. DO temperature limits will be reached. Packaging . . . . . 1, 5 & 55 gal. containers NOT USE OVER GALVANIZED METAL OR ZINC RICH Shipping Weight. . . . . . 4 gals. - 45 lbs. AGED MASONRY: Scrape, wire COATINGS. 5 gals. - 54 lbs. brush, or sandblast to remove loose 55 gals. - 600 lbs. particles of concrete and foreign PERFORMANCE INFORMATION: Application . . . Brush,roller, conventional matter. All oil, grease, and form and airless spray release compounds must be removed Provides excellent resistance to prior to painting surfaces. corrosive atmospheres, hostile (*) Gloss diminishes at higher temp- environmental conditions, and eratures. temperatures up to 500ºF (260ºC). (:) Varies with drying conditions; also, due to the thermoplasticity of the coating, when applied to hot surfaces (100º to 150ºF [38º to 66ºC)], it is important to note that the drying times will be greatly increased, as the coating stays soft and tacky for longer periods and full cure (hardness) may not be obtained for 7 days. TEMPERKOTE® 500 (Formerly Flame Control No. 500 Series) AIR DRIES, NO HEAT CURING REQUIRED HIGH PERFORMANCE INDUSTRIAL HEAT RESISTANT COATING *Maximum Service Temperature 500ºF (260ºC)
APPLICATION: APPLICATION EQUIPMENT: wear an appropriate, properly fitted
respirator (NIOSH/MSHA approved) Conventional Spray Mix paint thoroughly by boxing or during and after application. Air supply . . . . . . . . . . . . . . 12 CFM, stirring. Can be applied by brush, Follow respirator manufacturer's 50 psi at nozzle, fluid 15-20 psi roller or spray. Spray application is directions for respirator use. Close Gun. . . . . Graco 217-800 to 217-816 preferred, as a more uniform film is container after each use. Avoid Type . . . . . . . . . . . . . . External mix generally obtained. contact with eyes, skin and clothing. Reduction. . . . . . . . . . . . . . Up to 7% Wash thoroughly after handling. Do not apply heavier films than specified, as the coating may Airless Spray FIRST AID: If you experience blister. Titan 740 Impact (or Equivalent) difficulty in breathing, leave the area Pump to obtain fresh air. If continued STEEL: Where maximum corrosion Fluid Pressure. . . . . 2700-3100 psi difficulty is experienced, get medical resistance is desired, apply one coat Manifold Filter . . . . . . . . 60 Mesh assistance immediately. In case of of TemperKote No. 500 Fast Dry Gun Filter . . . . . . . . . . . 60 Mesh eye contact, flush immediately with Primer to achieve a maximum dry Fluid Hose . . . . . . . . ¼" diameter plenty of water for at least 15 film thickness of 1.5 mils (500 sq. Gun . . . . . . . . . . . . . . . . . LX-80 II minutes and get medical attention; ft./gal.). Under normal drying Tip. . . . . . . . . . . . . . . . .015 - .021 for skin, wash thoroughly with soap conditions. No. 500 Primer can be and water. If swallowed, get medical topcoated in 45 minutes. After the attention immediately. If spilled, primer is dry, apply one uniform coat PRECAUTIONS: contain spilled material and remove of No. 500 Series, in the desired WARNING! FLAMMABLE with inert absorbent. Dispose of color, to achieve a dry film thickness LIQUID & VAPOR: CONTAINS contaminated absorbent container of 1 to 1.3 mils per coat or No. 500 XYLENE & PETROLEUM and unused contents in accordance Series may be applied direct to low DISTILLATES. with local, state and federal profile sandblasted metal without a VAPOR HARMFUL. MAY regulations. primer, in two uniform coats at the AFFECT THE BRAIN OR above film thickness. NERVOUS SYSTEM CAUSING FOR INDUSTRIAL USE ONLY DIZZINESS, HEADACHE OR Note: TemperKote No. 500 Series NAUSEA. CAUSES EYE, SKIN, Read MSDS before opening No. 2 SILVER Heat Resistant NOSE AND THROAT containers. Coating should be applied direct to IRRITATION. NOTICE: Reports metal, without primer. Two coats are have associated repeated and KEEP OUT OF THE REACH OF recommended for best results. prolonged occupational overexposure CHILDREN to solvents with permanent brain and nervous system damage. Intentional AGED MASONRY: Apply No. 500 misuse by deliberately concentrating Series direct to clean masonry and inhaling the contents may be surfaces, without primer. Best results harmful or fatal. Keep away from As we cannot anticipate all conditions under which are obtained by applying two heat, sparks and flame. VAPORS this information and our products, or the products of uniform coats at a wet film thickness MAY CAUSE FLASH FIRE. Do not other manufacturers in combination with our of 4 to 5 mils per coat (320 to 400 smoke. Extinguish all flames and products, may be used, we accept no responsibility sq.ft./gallon/coat). pilot lights, and turn off stoves, for results obtained by the application of this Note: No. 500 Series Heat Resistant heaters, electric motors and other information or the safety or suitability of our Coatings air-cures, and, unlike other sources of ignition during use and products, either alone or in combination with other heat resistant paints, they do not until all vapors are gone. Prevent products. Users are advised to make their own tests require a complex heat-curing build-up of vapors by opening all to determine the safety and suitability of each such schedule to obtain the indicated heat windows and doors to achieve cross- product or product combination for their own resistance ventilation. purposes. We sell the products without warranty or guarantee, and buyers and users assume all responsibility and liability for loss or damage from USE ONLY WITH ADEQUATE For best performance, it is essential the handling and use of our products, whether used that the temperature be taken up VENTILATION. Do not breathe alone or in combination with other products. slowly, over a period of hours, to the vapors or spray mist. Ensure fresh air normal operating temperature. entry during application and drying. If you experience eye watering, headache or dizziness or if air monitoring demonstrates vapor/mist Revised 02/13 levels are above applicable limits,