TEMPERKOTE® 500

(Formerly Flame Control No. 500 Series)


AIR DRIES, NO HEAT CURING REQUIRED
HIGH PERFORMANCE INDUSTRIAL HEAT RESISTANT COATING
*Maximum Service Temperature 500ºF (260ºC)

CHARACTERISTICS: * Heat Resistance of Standard Colors:


DESCRIPTION:
Finish. . . . . . . .. . . . . . . . . . . . . (*) Gloss No. 1 Black . . . . . . Up to 500ºF (260ºC)
TemperKote No. 500 High No. 2 Silver. . . . . . . Up to 500ºF (260ºC)
Performance Heat Resistant Coatings Resin Type. . . . . . . Modified epoxy ester *No. 3 Lagoon . . . . . Up to 200ºF ( 93ºC)
are based on a one component *No. 4 Topaz . . . . . . Up to 250ºF (121ºC)
Primer. . . . . . . . . . . . . . . Phenolic Alkyd
*No. 5 Horizon . . . . . Up to 200ºF ( 93ºC)
specially modified epoxy ester resin.
Type of Cure. . . . . . Solvent evaporation/ *No. 6 Newport . . . . Up to 250ºF (121ºC)
The coatings air dry by polymerization oxidation *No. 7 Mauve . . . . . . Up to 200ºF ( 93ºC)
and oxidation to form a tough, No. 8 Walnut . . . . . Up to 500ºF (260ºC)
durable, heat, chemical, and moisture Drying Time @ 77ºF (25ºC) & 50%
*No. 9 Fawn . . . . . . . Up to 200ºF ( 93ºC)
R.H.
vapor resistant film. They do not *No.10 Russet . . . . . Up to 400ºF (204ºC)
(:) To touch. . . . . . . . . . . . . . . . . . . ½ hour
require any complex heat-curing (:) To recoat . . . . . . . . . . . . . ½ - 1 ½ hours *No.11 Quarry . . . . . Up to 200ºF ( 93ºC)
schedule to obtain their heat resistant If recoating cannot be done within that *No.12 Camouflage . Up to 350ºF (177ºC)
properties. time, allow to cure for 7 days before *No. 13 Dusty . . . . . Up to 200ºF ( 93ºC)
recoating. *No. 14 Golden . . . . Up to 350ºF (177ºC)
*No. 15 Charcoal . . . Up to 450ºF (232ºC)
No. 500 Series coatings are also
Curing Temperature & Time *No. 16 Steel . . . . . . Up to 200ºF ( 93ºC)
suitable for use on stainless steel Minimum curing *No. 17 Pewter . . . . . Up to 200ºF ( 93ºC)
surfaces; they are formulated with temperature. . . . . . . . . . . . . . . 50ºF (10ºC) *No. 18 White . . . . . Up to 200ºF ( 93ºC)
special ingredients to minimize Minimum curing Primer . . . . . . . . . . . . Up to 500ºF (260ºC)
contamination from chlorides, other time . . . . . . . . . . . . . . . . N/A (See drying
halides, sulfides, nitrates and metals time above) *NOTE: All standard colors will withstand dry
which are known to induce external service temperatures up to 500ºF (260ºC).
Application Temperature . . . . . . . . . . . . However, the temperature listed for each color
stress corrosion cracking. They 50ºF (10ºC) to (:) 150ºF (66ºC) indicates the maximum temperature that color
contain no free metallic zinc and, will withstand, with minimal color change.
Spreading Rate
therefore, will not contribute to Above the temperature shown, a significant
Per Coat . . . . . . . . . . . 420-560 sq.ft./gal. color change will occur. This color change is
embrittlement of stainless steel welds. (10.3-13.7 m2L) not reversible.
2.9-3.8 mils wet, 1-1.3 mils dry
RECOMMENDED USES:
Solids by Weight . . . . . Varies with color SURFACE PREPARTION:
Wherever resistance to heat, humidity Solids by Volume . . . . . Varies with color
and corrosive atmospheric conditions Weight Per Gallon . . . . Varies with color
STEEL: Sandblast or mechanically
is required. Can be used as a wire brush surface. Remove all
protective and decorative coating on Flash Point contaminants. i.e. rust, grease, wax,
of Liquid Coating . . . . . . . 80ºF (26.6ºC) oil, mill scale, etc. See application
metal parts, mufflers, hot water and (closed cup)
steam lines, where operating below for primers. A low profile
temperatures will not exceed 500ºF Reducer/Cleaner . . . . . . Xylol or Xylene sandblasted surface will give best
(260ºC). Not recommended for use Shelf Life . . . . . . . . . . 2 years (unopened) results, especially where the higher
on the inside of ovens, stacks, etc. DO temperature limits will be reached.
Packaging . . . . . 1, 5 & 55 gal. containers
NOT USE OVER GALVANIZED
METAL OR ZINC RICH Shipping Weight. . . . . . 4 gals. - 45 lbs. AGED MASONRY: Scrape, wire
COATINGS. 5 gals. - 54 lbs. brush, or sandblast to remove loose
55 gals. - 600 lbs. particles of concrete and foreign
PERFORMANCE INFORMATION: Application . . . Brush,roller, conventional matter. All oil, grease, and form
and airless spray release compounds must be removed
Provides excellent resistance to prior to painting surfaces.
corrosive atmospheres, hostile (*) Gloss diminishes at higher temp-
environmental conditions, and eratures.
temperatures up to 500ºF (260ºC).
(:) Varies with drying conditions; also, due
to the thermoplasticity of the coating,
when applied to hot surfaces (100º to
150ºF [38º to 66ºC)], it is important to note
that the drying times will be greatly
increased, as the coating stays soft and
tacky for longer periods and full cure
(hardness) may not be obtained for 7 days.
TEMPERKOTE® 500
(Formerly Flame Control No. 500 Series)
AIR DRIES, NO HEAT CURING REQUIRED
HIGH PERFORMANCE INDUSTRIAL HEAT RESISTANT COATING
*Maximum Service Temperature 500ºF (260ºC)

APPLICATION: APPLICATION EQUIPMENT: wear an appropriate, properly fitted


respirator (NIOSH/MSHA approved)
Conventional Spray
Mix paint thoroughly by boxing or during and after application.
Air supply . . . . . . . . . . . . . . 12 CFM,
stirring. Can be applied by brush, Follow respirator manufacturer's
50 psi at nozzle, fluid 15-20 psi
roller or spray. Spray application is directions for respirator use. Close
Gun. . . . . Graco 217-800 to 217-816
preferred, as a more uniform film is container after each use. Avoid
Type . . . . . . . . . . . . . . External mix
generally obtained. contact with eyes, skin and clothing.
Reduction. . . . . . . . . . . . . . Up to 7%
Wash thoroughly after handling.
Do not apply heavier films than
specified, as the coating may Airless Spray
FIRST AID: If you experience
blister. Titan 740 Impact (or Equivalent) difficulty in breathing, leave the area
Pump to obtain fresh air. If continued
STEEL: Where maximum corrosion Fluid Pressure. . . . . 2700-3100 psi difficulty is experienced, get medical
resistance is desired, apply one coat Manifold Filter . . . . . . . . 60 Mesh assistance immediately. In case of
of TemperKote No. 500 Fast Dry Gun Filter . . . . . . . . . . . 60 Mesh eye contact, flush immediately with
Primer to achieve a maximum dry Fluid Hose . . . . . . . . ¼" diameter plenty of water for at least 15
film thickness of 1.5 mils (500 sq. Gun . . . . . . . . . . . . . . . . . LX-80 II minutes and get medical attention;
ft./gal.). Under normal drying Tip. . . . . . . . . . . . . . . . .015 - .021 for skin, wash thoroughly with soap
conditions. No. 500 Primer can be and water. If swallowed, get medical
topcoated in 45 minutes. After the attention immediately. If spilled,
primer is dry, apply one uniform coat PRECAUTIONS:
contain spilled material and remove
of No. 500 Series, in the desired WARNING! FLAMMABLE with inert absorbent. Dispose of
color, to achieve a dry film thickness LIQUID & VAPOR: CONTAINS contaminated absorbent container
of 1 to 1.3 mils per coat or No. 500 XYLENE & PETROLEUM and unused contents in accordance
Series may be applied direct to low DISTILLATES. with local, state and federal
profile sandblasted metal without a VAPOR HARMFUL. MAY regulations.
primer, in two uniform coats at the AFFECT THE BRAIN OR
above film thickness. NERVOUS SYSTEM CAUSING FOR INDUSTRIAL USE ONLY
DIZZINESS, HEADACHE OR
Note: TemperKote No. 500 Series NAUSEA. CAUSES EYE, SKIN, Read MSDS before opening
No. 2 SILVER Heat Resistant NOSE AND THROAT containers.
Coating should be applied direct to IRRITATION. NOTICE: Reports
metal, without primer. Two coats are have associated repeated and KEEP OUT OF THE REACH OF
recommended for best results. prolonged occupational overexposure CHILDREN
to solvents with permanent brain and
nervous system damage. Intentional
AGED MASONRY: Apply No. 500
misuse by deliberately concentrating
Series direct to clean masonry
and inhaling the contents may be
surfaces, without primer. Best results
harmful or fatal. Keep away from As we cannot anticipate all conditions under which
are obtained by applying two
heat, sparks and flame. VAPORS this information and our products, or the products of
uniform coats at a wet film thickness
MAY CAUSE FLASH FIRE. Do not other manufacturers in combination with our
of 4 to 5 mils per coat (320 to 400
smoke. Extinguish all flames and products, may be used, we accept no responsibility
sq.ft./gallon/coat).
pilot lights, and turn off stoves, for results obtained by the application of this
Note: No. 500 Series Heat Resistant heaters, electric motors and other information or the safety or suitability of our
Coatings air-cures, and, unlike other sources of ignition during use and products, either alone or in combination with other
heat resistant paints, they do not until all vapors are gone. Prevent products. Users are advised to make their own tests
require a complex heat-curing build-up of vapors by opening all to determine the safety and suitability of each such
schedule to obtain the indicated heat windows and doors to achieve cross- product or product combination for their own
resistance ventilation. purposes. We sell the products without warranty or
guarantee, and buyers and users assume all
responsibility and liability for loss or damage from
USE ONLY WITH ADEQUATE
For best performance, it is essential the handling and use of our products, whether used
that the temperature be taken up VENTILATION. Do not breathe
alone or in combination with other products.
slowly, over a period of hours, to the vapors or spray mist. Ensure fresh air
normal operating temperature. entry during application and drying.
If you experience eye watering,
headache or dizziness or if air
monitoring demonstrates vapor/mist Revised 02/13