Вы находитесь на странице: 1из 3

Error

Error Message
Message Codes
Codes

Value Error
-1001 Failed to create the specified Pre/Post Processor
-1002 Pre/Post Processor has crashed
-1003 Pre/Post processor has timed out and the external process has been killed
-1004 Pre/Post processor has timed out but the external process cannot be terminated (and is therefore still running)
-1 Error in Isogen data. Check message file
-2 Isogen dll failed to load (possible installation problem, missing dependent file etc) or crash occurred during
execution, which has been trapped by the error handler.
-3 Isogen thread failed to finish – possible execution loop which has been terminated by Personal Isogen
0 Iso created successfully
1 Personal ISOGEN cannot find the isometric directory specified.

2 Invalid Style for this project. The specified Style cannot be found under the specified project
3 Specified Project not found. The specified project cannot be found
4 IDFGEN handshake failed. The handshake passed to the idfdll.dll has not been verified.

Note that a number of other “unexpected” failures have been found to generate this error.
5 Could not access specified PCF in TEMFILES.

6 ISOGEN DLL failed to establish current directory


7 ISOGEN DLL failed to change directory
8 The handshake passed to the pisodll.dll has not been verified.

9 Personal ISOGEN failed to produce a valid drawing. View message file for details as there are many possible
causes
10 ISOGEN DLL failed to restore working directory
11 IDFGEN DLL failed to establish current directory
12 IDFGEN DLL failed to change directory
13 IDFGEN did not complete successfully. View message file for details. One common cause is that the
components in the PCF do not form a connected system
14 IDFGEN DLL failed to restore working directory
15 IDFGEN could not delete IPISOGEN\PROGRAMS\FOR036.DAT from a previous run.
16 IDFGEN was unable to create ISOGEN.IDX file. Error opening isogen.idx
Error closing isogen.idx
17 IDFGEN was unable to copy ISOGEN.FLS to the PROGRAMS directory:-
Error allocating memory to store a line
Zero line length encountered
Error opening source isogen.fls (in specified project\isotype)
Error opening target isogen.fls (in pisogen\programs)
Error closing source isogen.fls (in specified project\isotype)
Error closing target isogen.fls (in pisogen\programs)
18
19 Personal ISOGEN handshake failed. The handshake passed to the pisogen.dll has not been verified.

20 Unknown Error in Personal ISOGEN. An unexpected path through the program has occurred.

21 PISOGEN DLL could not find Current W orking Directory. The current directory cannot be identified.
22 PISOGEN DLL could not Change Directory to \PISOGEN\PROGRAMS.
23 ISOGEN failed to write banner to message file. (Probably can’t find m essage file path):-
Error opening isogen.fls
Unable to find MESSAGE line in isogen.fls
Error closing isogen.fls
Error opening m essage file
Error closing message file
24 PISOGEN DLL has been unable to restore current working directory.
25 Error opening i-gen.fls for reading
Error opening isogen.fls for writing
Error opening options file specified in i-gen.fls
Error closing options file specified in i-gen.fls
Error opening i-gen.opl for writing
Error closing i-gen.opl
Error closing i-gen.fls
Error closing isogen.fls
26 Problem with the specified isom etric root directory
27 Problem setting the current isom etric root directory
28 Invalid file extension
29 Not applicable when running Isogen
30 W arning occurred creating a POD (intermediate) file
31 Error occurred creating a POD (intermediate) file. Error occurred during “pass 1” when the input IDF file is
preprocessed
32 Error occurred creating a POD (intermediate) file. Error occurred during “pass 2” when the POD file is being
created from Isogen data
33 Failed to load PODGRAPHICS DLL – used in the creation of graphics output files such as DW G and IGR.
34 PODGRAPHICS process failed – ie a graphics specific process has failed – for example, user requested IGR
output but SmartSketch is not installed
41 Cannot get path to system temp directory
42 System temp directory does not exist
43 Unable to set bore units to those specified in the input file
44 Unable to perform macro substitution in style ISOGEN.FLS
45 Unable to restore original style ISOGEN.FLS
50 Project disk is full – unable to create new output files
51 File containing temp directory is full – unable to process files
1000 Expected files missing in Style – eg no FLS, no options file
1001 Requested units combination is inconsistent – probably means a combination of metric bore and imperial co-
ordinates
1002 Invalid drawing format requested
1003 Problem deleting an ISOGEN message file
1004 Line in the options file has invalid format
1005 Too many switches in the options file
1006 Too few switches in the options files
1007 MicroStation design file output requested but MS_EXE environment variable is not defined
1008 MicroStation design file output requested but MicroStation not installed
1009 MS_EXE environment variable does not end with a \
1010 ISOGEN.FLS missing in Style
1011 Options file missing specified in ISOGEN.FLS is missing
Warning messages
1999 Isogen has returned a FAIL for one or more drawings in the set. This means it has been unable to layout the
drawing successfully
2001 Inconsistent units combination (imperial co-ordinates and metric bores)
2022 IDFGEN has detected disconnected pipeline. Drawings have still been created that will indicate the cause of the
disconnection.

Вам также может понравиться