Вы находитесь на странице: 1из 23

REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS AND HIGHWAYS


OFFICE OF THE BUILDING OFFICIAL
MUNICIPALITY OF SOGOD
PROVINCE OF SOUTHERN LEYTE

RECOMMENDING APPROVAL:

BUILDING OFFICIAL DATE

RECOMMENDING APPROVAL:

LAND USE & ZONING

SECTION HEAD DATE

RECOMMENDING APPROVAL:

LINE & GRADE

SECTION HEAD DATE

RECOMMENDING APPROVAL:

ARCHITECTURAL

SECTION HEAD DATE


KU

PROPERTY LINE
PA

RECOMMENDING APPROVAL:
TO

STRUCTURAL

SECTION HEAD DATE

PROPERTY LINE

PROPERTY LINE
TO SOGOD BU RECOMMENDING APPROVAL:
ILD
IN SANITARY
G
SECTION HEAD DATE

RECOMMENDING APPROVAL:

TH
ELECTRICAL

PROPERTY LINE
I SS
ITE TO
BA SECTION HEAD DATE
TO
PROPERTY LINE
VICINITY MAP RECOMMENDING APPROVAL:
scale 1 : 100 m
MECHANICAL
SITE DEVELOPMENT PLAN
scale 1 : 100 m SECTION HEAD DATE

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER A1
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
A B D E
Y

3.00 2.00 2.00


W3

1 1

1.00
D2

1'

2.60

1.60
W4
D3
W2

2 2

2.00
3.00
W1
W1

1.00
10.60

10.60
D2

4 X X 4
D3 W4

2.00
3.00
D3 W4
W2

D2 5
6 W1
D1

3.00
W1

2.00
W2

8 8
W2

FLOOR PLAN
scale 1 : 100 m
Y
4.00 3.00

A C E

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER A2
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
A C E
APEX 4.00 3.00

2.00
1.02
TOB
3.00
3.20

F.F.L
N.G.L

FRONT ELEVATION
scale 1 : 100 m

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER A3
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
E D B A
APEX 2.00 2.00 3.00

2.00
TOB 3.00
3.20

F.F.L
N.G.L

REA R ELEVATION
scale 1 : 100 m
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER A4
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
8 5 4 2 1' 1
3.00 2.00 3.00 1.60 1.00
2.00 APEX

TOB
3.00
3.20

F.F.L
N.G.L

RIGHT ELEVATION
scale 1 : 100 m
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER A5
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
SWING FRENCH WINDOW WITH 1/4" THK.
TEMPERED PLATE CLEAR GLASS ON
NARRA WOOD FRAMING. (SUBMIT
WIDTH WIDTH WIDTH MANUFACTURER'S DRAWING DETAILS
AND CONSULT WITH PROJECT
ENGINEER OR THE ARCHITECT)

HEIGHT CLEAR WINDOW HEIGHT


CLEAR

CLEAR HEIGHT
3-PANEL WINDOW

SILL
TYPICAL DETAILS

spanish gutter
0.20 0.20

1
4" thk mar. plywood fascia board
3
4" thk plyboard ceiling

fr 1" x 1" wood


lumber air vent
4" victorian base 0.50 0.30 0.05
board
1
4" thk mar. plywood
ceiling
0.40 0.40

detail 1 blow-up detail 1


details
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER A7
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
1 2 4 6 8
APEX 2.60 3.00 3.00 2.00
2.00

TOB
3.00
3.20

F.F.L
N.G.L

LEFT ELEVATION
scale 1 : 100 m
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER A6
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
1' 2 3 6 8
1.60 2.00 4.00 2.00
2.00 APEX

SEE TRUSS DETAIL

TOB
3.00
3.20

F.F.L
N.G.L

S E C T I O N T HR U Y - Y
scale 1 : 100 m
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER A8
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
A C E
4.00 3.00
APEX

2.00 TOB

3.00
3.20

F.F.L
N.G.L

SECTION TRHU X-X


scale 1 : 100 m

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER A9
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
schedule of doors and window
width Length no. of
location
(mm) (mm) panels
D1 1000 2100 main
swing door, glass type 2
swing
D2 800 2100 bedrooms
door,flush type 3

swing door,flush
D3 750 2100 t&b
3
type
dining
sliding window
W1 600 1200 room & bedrooms glass type 3
sliding window
W2 600 1200 living
glass type 2

sliding window
W3 600 1000 kitchen
glass type 2

sliding window
W4 600 600 t&b
glass type 1

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER A10
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
verify
FLOOR BEAM

@ 100mm on center
lateral ties spacing
TIES (SEE COLUMN

18" w/cever is greater


H/6 or Col. Depth or
SKED. FOR SPACING)

lateral ties spacing (refer col. sked.)


CLEAR HEIGHT (Hn)

2H/3
NAT. GRD. LINE

18" w/cever is greater


H/6 or Col. Depth or

lateral ties spacing @ 100mm o.c.


900 Min

verify
FLOOR BEAM
FTB FTB

18" w/cever is greater


H/6 or Col. Depth or
COLUMN TIES VERTICAL REINF.

REINF. BAR REINF. BAR


ALONG X DIRECTION ALONG Y DIRECTION
400

lateral ties spacing (refer col sked)


CLEAR HEIGHT (H1)
1000 BARS SPCD. EVENLY 50 MM
LEAN CONCRETE

2H/3
BOTH WAYS REINF. BAR
ALONG Y DIRECTION

REINF. BAR
ALONG X DIRECTION

18" w/cever is greater


H/6 or Col. Depth or
FIN. FLR LINE
1000

250

lateral ties spacing @ 100mm o.c.


verify
TIE BEAM
OPTIONAL

verify
verify
250
BASE

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER S2
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
L1/4+12D L1/4+12D L2/4+12D L2/4+12D BREATH

TOP BARS

STIRRUPS

DEPTH
(TYPICAL)
WEB BARS

D24
L/7 STIRRUPS L/5 L/5
10mm L3 (CANTILEVER SPAN) BOTTOM BARS
EXTCOL L/5 INTCOL INTCOL
L1(END SPAN) L2 (INTERIOR SPAN)

I. GENERAL NOTES
PROVIDE TWO SETS OF
1. CONSTRUCTION NOTES AND TYPICAL DETAIL APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED. STIRRUPS @ SPLICE
MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.
EXTRA TOP BARS EXTRA BOTT. BARS 2-16D
2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAM OF ALL STRUCTURAL STEEL, MISCELLANEOUS IRON,
@ END SUPPORT @ MID SPAN 2-12D
PRETRESS, PRECAST WORKS, ETC. SHALL BE SUBMITTED FOR STRUCTURAL ENGINEERS APPROVAL.

350
300
3. CONSTRUCTOR SHALL VERIFY ALL DIMENSION BEFORE ANY WORK BEGUN, CHECK MECHANICAL & ELECTRICAL L/4 BREATH

200

150
CONTRACTORS FOR CONDUITS, PIPE SLEEVES ETC. TO BE EMBEDDED IN CONCRETE. 1-12D 2-16D 2-16D
2-12D

H/4
4. IT SHALL BE THE CONSTRUCTOR RESPONSIBILITY TO PROVIDE ADEQUATE BRACING OF THE STRUCTURES FOR MAIN VERTICAL 150
150 150

DEPTH
ALL LOADS THAT MAY BE IMPOSED DURING CONSTRUCTION. 150
COLUMN REINF.
5. IN THE INTERPRETATION OF THIS DRAWINGS, INDICATED DIMENSION SHALL GOVERN AND DISTANCES OR SIZES 10D STIRRUPS 1@150, 10D STIRRUPS 1@150, 10D STIRRUPS 1@150, 10D STIRRUPS 1@150,
SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES. REST @ 300 3@200, REST @ 300 3@100, REST @ 300 3@100, REST @ 300
6. ALL CONCRETE WORKS SHALL BE DONE IN ACCORDANCE WITH THE LATEST ACI SPECIFICATIONS, IN SO FAR MAX. SPAN
MAX. SPAN MAX. SPAN MAX. SPAN
AS THEY DO NOT CONFLICT WITH LOCAL BUILDING CODE AND THIS NOTES. L/5 30Db 1.20M
30Db>16D & larger bars 2.50M 3.50M 4.0M
7. USE STRUCTURAL EPOXY FOR ALL CONSTRUCTION JOINTS AT WATER TANK, TOILET SLABS AND ROOF DECK 40Db>12D & smaller bars
SLAB
COLUMN REINF. BARS SHALL ABOVE DOOR / WINDOW OPENINGS ON CHB WALL
BE SPLICE AT TWO LEVELS (EXTEND 300MM FROM EDGES OF MASONRY OPENINGS)

H/2
WITH NUMBER OF BARS PER TYPICAL DETAIL OF COLUMN

LAP SPLICE
II. DESIGN CRITERIA LEVEL @ LEAST 50% OF NO.
LAP SPLICE & EXT. BEAM TO
E. DESIGN STRESSES OF MAIN VERT.BARS
A. LIVE LOADS
A.1 ROOF LIVE LOADS E.1 REINFORCED CONCRETE, fc' = COLUMN CONNECTION 4-12D, 2.0M LONG
12D, 1.0 METER LONG @
E.1.1 BEAMS, COLUMNS, SUSPENDED SLABS RECOMMENDED HOOPS MID-DEPTH OF SLAB @
ROOF = 1.00 KPa TOP BAR BEND DOWN
S=0.25d <100MM EACH OPENING CORNER
DUE TO PONDING = 0.75 KPa fc' = 21 MPa INTO EDGE BEAM
OMIT BARS WHERE OPENING
A.2 FLOOR LIVE LOADS E.1.2 SLAB ON FILL 0 IS FRAMED BY BEAM
COLUMN MAIN REINF. 55
OFFICE = 2.40 kPa fc' = 17.5 MPa
LOBBY = 4.80 kPa E.1.3 FOOTINGS BAR SPLICE SHALL BE

H/4
LIMITED @ MIDHEIGHT, 0
B. DEAD LOADS fc' = 21 MPa 55
= 0.24 kPa H/2 MIN.=30 Db MIN.=30 Db

55
B.1 FLOOR MORTAR FINISH E.2 REINFORCING STEEL

0
B.2 PARTITION = 0.75 kPa OPEN
E.2.1 INTERMEDIATE BARS (deformed)
B.3 CEILING AND UTILITIES = 0.40 kPa
fy = 276 MPa (10MM, 12MM, 16MM, 20MM)
E.2.2 HARD GRADE BARS 4-12D 1-12D TOP &
C. WIND LOADS BOTTOM BARS
BOTT.BARS

DEPTH
2 fy = 414 MPa (25MM)
p = 0.00256V Ch

DEPRESSION
V = WIND VELOCITY

(VERIFY)
Ch = HEIGHT CORRECTION FACTOR E.2.3 STRUCTURAL STEEL, USE ASTM A36 FOR SEISMIC REQM'T
E.3 FOUNDATION PROVIDE TIES AT LEAST
D. SEISMIC LOAD
V = ZIC W/Rw E.3.1 SOIL BEARING CAPACITY = 133 KPa THREE (3) TIES @ COLUMN
where: BEAM CONFINEMENT MIN.=30 Db DEPTH
E.3.2 IN CASE THE ACTUAL SOIL BEARING
V= BASE SHEAR CAPACITY IS LESS THAN THE ASSUMED
Z = 0.40 TYPICAL SLAB TYPICAL SLAB
VALUE THE ENGINEER IN CHARGE OF
C = 1.25S/(T^(2/3))<2.75 THE CONSTRUCTION SHALL NOTIFY THE CORNER DETAIL OPENING DETAIL
I = 1.0
TYPICAL COLUMN ELEVATION TYPICAL DETAIL FOR BEAM
STRUCTURAL ENGINEER FOR SOME
W= DEAD LOAD RECOMMENDATION. OR SLAB CHANGE SOFFIT
150MM THICK 150MM THICK
III. CONSTRUCTION NOTES CHB WALL W/ CHB WALL W/ MAIN REINF BARS
10D @ 600 E.W. 10D @ 600 E.W.
A. REINFORCED CONCRETE

T
SLAB ON GRADE SLAB ON GRADE

Y<250
A.1. THE QUALITY AND DESIGN OF ALL REINFORCED CONCRETE CONSTRUCTION SHALL CONFORM WITH
THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE (ACI - 318.95) AND MANUAL OF PROVIDE 3 ADDT'L
STIRRUPS EACH SIDE

DEPTH
STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES (ACI - 315).
OF THE SLEEVES
A.2. ALL CONCRETE SHALL BE MACHINE MIXED AND MECHANICAL VIBRATOR SHALL BE USED FOR
COMPACTING CONCRETE.
SLEEVES FOR UTILITY
A.3. MINIMUM CONCRETE COVERING FOR REINFORCING STEEL SHALL BE: 38MM - BEAMS AND NGL EARTH FILL (PIPE MIN DIAM.=50MM)
COLUMNS, 38MM - FORMED SURFACE BELOW GRADE. FOR 16MM DIA. BARS AND SMALLER = 50MM.
FOR BARS LARGER THAN 16MM DIAMETER CONCRETE POURED AGAINST EARTH = 75MM.
BREATH CONTINOUS MAIN
A.4. ALL REINFORCING STEEL, ANCHOR BOLTS, DOWELS AND OTHER INSERTS SHALL BE WELL SECURED REINFORCEMENTS

200
200

IN POSITION BEFORE PLACING THE CONCRETE.


TYPICAL SLEEVES DETAIL Db x1000
A.5. NO CONCRETING SHALL BE ALLOWED UNLESS ALL BAR PLACEMENTS HAVE BEEN INSPECTED BY THE
STRUCTURAL ENGINEER.
THRU CONCRETE BEAM @300 O.C.

19
400 400

B. CONCRETE MASONRY UNITS WF-1 WF-4 VERTICAL REINF.

t
150MM THICK 150MM THICK
COLUMN TIES

t-38
B.1. CELLS CONTAINING REINFORCEMENTS SHALL BE SOLIDLY FILLED WITH GROUTS NOT TO EXCEED CHB WALL W/ CHB WALL W/

19
1.2 METERS AND POURING SHALL BE STOPPED 38MM BELOW AT TOP OF A COURSE TO FORM A 10D @ 600 E.W. 10D @ 600 E.W. REINF. BARS
KEY AT POURED JOINTS. NGL ALONG X SLAB
REINF. BARS

MIN. D=1.2M
B.2. VERTICAL CELLS TO BE FILLED SHALL HAVE A VERTICAL ALIGNMENT TO MAINTAIN A CONTINUOUS
ALONG Y MIN.=30Db D MIN.=30Db
UNOBSTRUCTED CELL AREA NOT LESS THAN 50MM X 75MM.
50 MM LEAN
B.3. VERTICAL BARS SHALL BE HELD IN POSITION AT TOP AND BOTTOM OF THE REINFORCEMENTS AND CONCRETE

T
AT INTERVALS NOT EXCEEDING 192 BAR DIAMETER. 3-10D
3-10D 10D

50
B.4. PROVIDE 10 DIAM. DOWELS X 900MM LONG @ 600MM ON CENTERS. 10D
DEPRESSED

50
SLAB X DIRECTION

100

D
100 150

C. REINFORCING STEEL
C.1. REINFORCEMENTS SHALL BE DEFORMED BRAS CONFORMING TO ASTM A-615 (DEFORMATION).
100
100

C.2. MINIMUM LAP SPLICES UNLESS OTHERWISE INDICATED SHALL:

Y DIRECTION
PROVIDE SHEAR RODS
C.2.1 FOR CONCRETE = 30 BAR DIAMETER BUT NOT LESS THAN 300 MM. WHERE JOINT IS @
100 400 100 100 400 100
C.2.2 FOR UNIT MASONRY = 40 BAR DIAMETER. MAIN REINFORCEMENTS POINT OF STRESS
TO & BOTTOM CONT.BARS
D. FOUNDATION WF-3 WF-2
ALL FOOTINGS SHALL REST ON NATURAL GROUND. BEAM

E. DISCREPANCY TYPICAL CONCRETE HOLLOW BLOCK TYPICAL FOOTING DETAIL TYPICAL SLAB AND BEAMS
ALL DISCREPANCY BETWEEN THE DESIGNERURAL AND STRUCTURAL PLANS SHALL BE REPORTED TO WALL FOOTING (WHERE APPLICABLE) CONSTRUCTION JOINT DETAIL
THE DESIGNER BEFORE PROCEEDING WITH THE PORTION OF THE WORK INVOLVED.

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER S3
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER S4
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
SCHEDULE OF BEAMS
BEAM SECTION REINFORCEMENT
NAME SPAN STIRRUPS
width depth @ Exterior Support @ Mid Span @ Interior Support

d10 BARS U-STIRRUPS


2-d12 2-d12 2-d12 SPCD 2@75mm;
RB-1 250 250 vary 3@100mm;
2-d12 2-d12 2-d12 rest @ 200mm
2-d12 2-d12 2-d12

DIMENSION REINFORCEMENT
FOOTING
W L T
MARK
ALONG X ALONG Y
MILLIMETERS

F-1 1000 1000 400

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
MR. ELMER MOSQUITO
OWNER S5
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
5.00
SPANISH GUTTER

3.80

3
T-
T-

H
3

H 1.00
3
T-
2.00

1.60
2
T-
H
V
2.00

T-
2

2
T-
H
SPANISH GUTTER

1
10.20

12.60

T-
T-

H
1
H
T-
4

10.00
V T-1

6.40

SPANISH GUTTER
H
1
4

T-
T-

T-
H
H

1
H T- 6
6.60

H
5
T-
T-

T-
H
5

5
BEAM PLAN
scale 1 : 100 m
SPANISH GUTTER

9.00
ROOF FRAMING PLAN
scale 1 : 100 m
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.

PRC No.: 0095488


REC ALFONSO P. CINCO
CIVIL ENGINEER
Date Reg. :01-17-2003 T I N No.: 930-581-907
OWNER
MR. ELMER MOSQUITO
S6
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
2.00
6.67

2.00
0.50 1.00 1.00 1.00 1.00 1.00 0.50

1.00 1.00 1.00 1.00 1.00 0.36


V T-1
H T-1

3.70

1.11
4.9
8 5.24

2.00

1.56
1.00 1.00 0.54

H T-3
1.00 1.00 1.00 0.50
H T-4 1.00 1.00 1.00 0.95
H T-2

1.48

2.22

0.67
1.56
TRUSS DIAGRAM

1.11
0.58 0.54
ROOF PLAN scale 1 : 100 m
scale 1 : 100 m 0.71 0.71 H T-5
V T-2

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER S7
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
A B D E

3.00 2.00 2.00

1 1
C1 F1 C1 F 1
100mm thick on
1'

2.60

2.60
well tampered C1 F1
gravel based 90mm THK
ON WELL
tampered

C1 F1 C1 F 1 gravel based

2 2
C1 F1

2.00
100mm thick on
well tampered

3.00
gravel based
C1 F1 100mm thick on C1 F 1
3

1.00
10.60

10.60
well tampered C1 F1
4 gravel based
90mm thick on well
4
tampered
gravel based

2.00
90mm thick on well

3.00
tampered
gravel based

C1 F1 C1 F1
5
C1 F1
6 100mm thick on

3.00
2.00 100mm thick on well tampered
well tampered gravel based
gravel based C1 F 1 C1 F1

8 8
F O U N D A T I O N PLAN 4.00 3.00
scale 1 : 100 m
7.00

A C E
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE. REC ALFONSO P. CINCO
CIVIL ENGINEER
MR. ELMER MOSQUITO
OWNER S1
PRC No.: 0095488 Date Reg. :01-17-2003 T I N No.: 930-581-907
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. 3156730 Date: 01-03-2011 Place: Maasin City, So. Leyte
to water source
ST

CO

CO

fd

CO
CO

CO

fd

fd

CO
CO

WATER LINE LAYOUT SANITARY LAYOUT


scale 1 : 100 m scale 1 : 100 m

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
MASTER PLUMBER
MR. ELMER MOSQUITO
OWNER P1
PRC No.: Date Reg. : T I N No.:
PTR No. Date: Place:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PLUMBING SPECIFICATIONS
1. ALL PIPES PASSING THROUGH OR UNDER DRIVEWAYS SHALL BE PROPERLY PROTECTED AGAINST
BREAKAGE WITH REINFORCED CONCRETE.
2. ALL HORIZONTAL PIPINGS SHALL RUN IN A PRACTICAL ALIGNMENT AND AT UNIFORM GRADE NOT LESS
THAN ONE PERCENT (1%) AND SHALL BE ANCHORED OR SUPPORTED AT AN INTERVAL NOT TO EXCEED
1.50 METERS.
3. ALL WALLS WITH PLUMBING ROUGH-IN SHALL BE 150 mm THICK CHB.
4"0 x 45
4. WORKMANSHIP SHALL BE OF CHARACTERISTICS AS TO FULLY SECURE THE RESULT SOUGHT IN ALL
ELBOW
THE PROVISIONS OF THE NATIONAL PLUMBING CODE OF THE PHILIPPINES.
5. INSTALL ALL PIPING IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND
SPECIFICATIONS. 4"0 x 4"0
4"0 x 4"0
WYE
6. UPON COMPLETION OF THE WATER SYSTEM, FLUSH OUT LINES TO CLEAR SYSTEM OF PARTICLES, WYE 4"0 x 45
DIRT AND CLEAN ALL VALVES. ELBOW
7. ALL PLUMBING INSTALLATIONS SHALL BE DONE UNDER THE DIRECT SUPERVISION OF A DULY
LICENSED MASTER PLUMBER.

HORIZONTAL TO VERTICAL MAIN VENT STACK


CERTIFICATION:
THIS IS TO CERTIFY THAT THERE IS NO EXISTING ARTESIAN WELL WITHIN A RADIUS OF
25.00 M FROM THE PROPOSED SEPTIC TANK.

0.10 0.10
0.70
MASTER PLUMBER
0.50

0.10
FIN. FLOOR LINE
CONCRETE GROUT
R.C. FLOOR SLAB

0.70

0.50
4" THK. FLOOR DRAIN

0.10
4"0 x 45 PLAN
ELBOW
0.70

CONCRETE COVER
4"0 x 4"0
WYE
VERTICAL TO HORIZONTAL

0.70
FLOOR DRAIN DETAIL
4" THK. CHB
PLUMBING JOINTS
0.10
ELEVATION/SECTION

CATCH BASIN DETAIL


FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
MASTER PLUMBER
MR. ELMER MOSQUITO
OWNER P2
PRC No.: Date Reg. : T I N No.:
PTR No. Date: Place:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
0.70
0.10 0.10 0.10
1.5 2..50
0.10

0.70
note:

0.50 x 0.50 manhole 0.50 x 0.50 manhole @ 0.10 m.o.c bothways


2.50

0.10
co co
PLAN
0.10

0.70

plan CONCRETE COVER

co manhole co manhole co
0.10

0.30 m airspace 50 mm CONC.

0.70
inlet BAFFLE

outlet
4" THK. CHB
2.00

0.10
leaching chamber digestive chamber ELEVATION/SECTION
4" thk CHB

GREASE TRAP DETAIL


0.20

section
septic tank detail
FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
MASTER PLUMBER
MR. ELMER MOSQUITO
OWNER P3
PRC No.: Date Reg. : T I N No.:
PTR No. Date: Place:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
S 3 S1
C6
C4

S2

C8
C3
S2

S2
C2
S2 C5
S1

C1 C7

LIGHTING LAYOUT
scale 1 : 100 m P O W E R LAYOUT
scale 1 : 100 m

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
ELECTRICAL ENGINEER
MR. ELMER MOSQUITO
OWNER E1
PRC No.: Date Reg. : T I N No.:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. Date: Place:
C5
C6
C7
SINGLE LINE DIAGRAM C8

ELECTRICAL SPECIFICATIONS 220v


Spare

60Hz Spare
2-14.00 mm THHN or equivalent
1. ALL ELECTRICAL WORKS AND INSTALLATION THERE IN SHALL BE DONE IN
M
ACCORDANCE WITH THE PROVISIONS OF THE LATEST APPROVED EDITION OF
THE PHILIPPINE ELECTRICAL CODE WITH THE RULES AND REGULATIONS OF
THE NATIONAL AND LOCAL AUTHORITIES CONCERNED IN THE ENFORCEMENT
OF ELECTRICAL LAWS AND ORDINANCES AND WITH THE POLICIES OF THE
LOCAL UTILITY COMPANY CONCERNED.

2. NO WIRE SMALLER THAN No. 3.5 mm2 AWG TWGSHALL BE USED.


50AT
3. ALL MATERIALS USED SHALL BE NEW AND OF APPROVED TYPE FOR BOTH
LOCATION AND PURPOSES INTENDED.
15AT 15AT
4. ALL OUTDOOR INSTALLATION SHALL BE OF WEATHER PROOF TYPE.
3.5 mm 3.5 mm
C2 C1
5. ALL ELECTRICAL WOKS AND INSTALLATION HERE IN SHALL BE DONE
UNDER THE DIRECT SUPERVISION OF A DULY REGISTERED ELECTRICAL 15AT 15AT
ENGINEER OR MASTER ELECTRICIAN.
3.5 mm 3.5 mm
C4 C3
20AT 20AT
SAMPLE COMPUTATION 5.5 mm 5.5 mm
C6 C5

It =[ total connected load plus 25% of the larges motor x demand factor
220V ] 20AT 20AT
5.5 mm 5.5 mm
C8 C7
It =[ ] 7552W + (0.25)(746)
220V
x 0.80
20AT 15AT

It =24.14A Spare 5.5 mm 3.5 mm


Spare

NOTE: Assume 80% demand Factor


Therefore:
use 50AT main circuit protection
use 14.00 mm THHN wire or equivalent for mainline

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
ELECTRICAL ENGINEER
MR. ELMER MOSQUITO
OWNER E2
PRC No.: Date Reg. : T I N No.:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE
PTR No. Date: Place:
SCHEDULE OF LOADS
SWITCHES
Load Description Circuit
CIRCUIT POWER Voltage Current Conductor Conduit
Protection
S1 S2 S3 SW Size Size

C1 Lighting Outlet 1 1 500 W 220V 2.27A 15 AT,2P 3.5mm2 13mm

C2 Lighting Outlet 2 800 W 220V 3.64A 15 AT,2P 3.5mm2 13mm

C3 Lighting Outlet 2 1 600 W 220V 2.73A 15 AT,2P 3.5mm2 13mm

C4 Lighting Outlet 1 400 W 220V 1.82A 15 AT,2P 3.5mm2 13mm

convenience
C5 Outlet
3200W 220V 14.54A 20 AT,2P 5.5mm2 20mm

Refrigerator
C6 Outlet 560 W 220V 2.54 A 20 AT,2P 5.5mm2 20mm

C7 ACU 746 W 220V 3.39 A 20 AT,2P 5.5mm2 20mm

C8 ACU 746 W 220V 3.39 A 20 AT,2P 5.5mm2 20mm

Spare 220V 15 AT,2P

Spare 220V 20 AT,2P

FROM THE OFFICE OF: SEAL NAME OF PROJECT: APPROVED AS PER PLAN: SHEET CONTENTS: SHEET NUMBER

NO PORTION OF THIS SET OF PLAN SHOULD BE


COPIED EITHER MANUALY OR ELECTRONICALLY
WITHOUT THE WRITTEN CONSENT OF THIS OFFICE.
ELECTRICAL ENGINEER
MR. ELMER MOSQUITO
OWNER E3
PRC No.: Date Reg. : T I N No.:
PTR No. Date: Place:
LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE LOCATION: BRGY. BUENAVISTA, BONTOC, SOUTHERN LEYTE