Академический Документы
Профессиональный Документы
Культура Документы
0 Product Specification
Rev 1.0
( )Preliminary Specifications
(*
*)Final Specifications
CONTENTS
1. GENERAL DESCRIPTION ............................................................................................................................................4
3. ELECTRICAL SPECIFICATION..................................................................................................................................6
4. OPTICAL SPECIFICATION........................................................................................................................................21
5. MECHANICAL CHARACTERISTICS.......................................................................................................................25
6. PACKING........................................................................................................................................................................26
7. PRECAUTIONS .............................................................................................................................................................29
RECORD OF REVISION
Version Date Page Description
0.0 2012/12/19 First release
0.1 2013/1/8 4 Remove LCD in “This LCD Open Cell”
21 Modify Color Chromaticity ( RGBW )
Modify 2D drawing , the height of components on PCBA is 3.75mm
25
4.2mm ( Max )
th
26 Modify open cell shipping label , 4 area 12 units 11 units
Modify packing process ,change pallet dimension &
27
packing quantity
1.0 2013/2/19 4 Signal input with “A” “ABC”
11 T-Con Board Pin Map , modify pin 24 , 25 , 40 , 41 to N.C.
1. General Description
This specification applies to the 38.5 inch Color TFT-LCD SKD model T390HVN04.0. This Open Cell Unit has a
TFT active matrix type liquid crystal panel 1,920x1,080 pixels, and diagonal size of 38.5 inch. This module supports
1,920x1,080 mode. Each pixel is divided into Red, Green and Blue sub-pixels or dots which are arranged in vertical
stripes. Gray scale or the brightness of the sub-pixel color is determined with a 8-bit gray scale signal for each dot.
* General Information
3. Electrical Specification
The T390HVN04.0 Open Cell Unit requires power input which is employed to power the LCD electronics and to
drive the TFT array and liquid crystal.
3.1.2 AC Characteristics
Value
Parameter Symbol Unit Note
Min. Typ. Max
Receiver Clock : Spread Spectrum Fclk Fclk
Fclk_ss -- MHz 6
Modulation range -3% +3%
Receiver Clock : Spread Spectrum
LVDS Fss 30 -- 200 KHz 6
Modulation frequency
Interface
Receiver Data Input Margin
Fclk = 85 MHz tRMG -0.4 -- 0.4 ns 7
Fclk = 65 MHz -0.5 -- 0.5
SCL clock frequency FSCL 0 -- 400 KHZ
I2C clock high level TSCHi 0.6 -- -- us
I2C clock low level TSCLo 1.2 -- -- us
I2C
I2C data setup time TSDS 100 -- -- ns
Interface
I2C data hold time TSDH 0 -- 900 ns
SDA and SCL rise time TR -- -- 1000 ns
SDA and SCL fall time TF -- -- 300 ns
Note :
1. Test Condition:
(1) VDD = 12.0V
(2) Fv = Type Timing, 60Hz, 120Hz or Other
(3) Fclk= Max freq.
(4) Temperature = 25 ℃
(5) Typ. Input current : White Pattern
Max. Input current: Heavy loading pattern defined by AUO
>> refer to “Section:3.3 Signal Timing Specification, Typical timing”
10%
GND
400 µs
3. Test Condition:
(1) The measure point of VRP is in LCM side after connecting the System Board and LCM.
(2) Under Max. Input current spec. condition.
4. VICM = 1.25V
5. The measure points of VIH and VIL are in LCM side after connecting the System Board and LCM.
6. LVDS Receiver Clock SSCG (Spread spectrum clock generator) is defined as below figures.
tRIP2
tRIP3
tRIP4
tRIP5
tRIP6
tRIP0
tRIP1
LVDS-Rx
Rx3 Rx2 Rx1 Rx0 Rx6 Rx5 Rx4 Rx3 Rx2 Rx1 Rx0 Rx6
Input Data
LVDS-Rx
Input Clock Vdiff = 0V
1/Fclk=T
5 N.C. No connection (for AUO test only. Do not connect) 30 CH2_1- LVDS Channel 2, Signal 1-
6 N.C. No connection (for AUO test only. Do not connect) 31 CH2_1+ LVDS Channel 2, Signal 1+
8 N.C. No connection (for AUO test only. Do not connect) 33 CH2_2+ LVDS Channel 2, Signal 2+
9 N.C. No connection (for AUO test only. Do not connect) 34 GND Ground
10 N.C. No connection (for AUO test only. Do not connect) 35 CH2_CLK- LVDS Channel 2, Clock -
24 N.C. No connection (for AUO test only. Do not connect) 49 VDD Power Supply, +12V DC Regulated
25 N.C. No connection (for AUO test only. Do not connect) 50 VDD Power Supply, +12V DC Regulated
SCL/SDA WP
C lo ck
C H x_0+ R1 R0 G0 R5 R4 R3 R2 R1 R0 G0
C H x_0-
C H x_1+ G2 G1 B1 B0 G5 G4 G3 G2 G1 B1
C H x_1-
C H x_2+
C H x_2- B3 B2 DE NA NA B5 B4 B3 B2 DE
C H x_3+
C H x_3- R7 R6 NA B7 B6 G7 G6 R7 R6 NA
Note: x = 1, 2, 3, 4…
C lo ck
CH x_0+ R3 R2 G2 R7 R6 R5 R4 R3 R2 G2
CH x_0-
CH x_1+ G4 G3 B3 B2 G7 G6 G5 G4 G3 B3
CH x_1-
G7
CH x_2+
CH x_2- B5 B4 DE NA NA B7 B6 B5 B4 DE
CH x_3+
CH x_3- R1 R0 NA B1 B0 G1 G0 R1 R0 NA
Note: x = 1, 2, 3, 4…
Notes:
(1) Display position is specific by the rise of DE signal only.
st st
Horizontal display position is specified by the rising edge of 1 DCLK after the rise of 1 DE, is displayed on the
left edge of the screen.
(2)Vertical display position is specified by the rise of DE after a “Low” level period equivalent to eight times of
st st
horizontal period. The 1 data corresponding to one horizontal line after the rise of 1 DE is displayed at the top
line of screen.
(3)If a period of DE “High” is less than 1920 DCLK or less than 1080 lines, the rest of the screen displays black.
(4)The display position does not fit to the screen if a period of DE “High” and the effective data period do not
synchronize with each other.
Page 15 / 30
Tv M pixel
Tblk(v) Tdisp(v)
N L in e
Th
DE
RGB Line Invalid Data Line Line Line Line Line Invalid Data
N 1 2 3 4 N
Data
Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel
CH1 M-7 M-5 M-3 M-1
Invalid Data
1 3 5 7 9 11 M-5 M-3 M-1
Invalid Data
1 3
Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel Pixel
CH2 M-6 M-4 M-2 M
Invalid Data
2 4 6 8 10 12 M-4 M-2 M
Invalid Data
2 4
T390HVN04.0 Product Specification
Rev 1.0
The brightness of each primary color (red, green and blue) is based on the 8 bit gray scale data input for the color;
the higher the binary input, the brighter the color. The table below provides a reference for color versus data input.
Values Unit
Parameter
Min. Type. Max. Min.
t1 0.4 --- 30 ms
t2 0.1 --- 50 ms
t3 450 --- --- ms
*1
t4 0 --- --- ms
t5 0 --- --- ms
t6 --- --- --- ms
t7 500 --- --- ms
*3
t8 10 --- 50 ms
t9 0 --- --- ms
t10 450 --- --- ms
t11 150 --- --- ms
Note:
(1) t4=0 : concern for residual pattern before BLU turn off.
(2) t6 : voltage of VDD must decay smoothly after power-off. (customer system decide this value)
(3) When CMOS Interface signal is N.C. (no connection), opened in Transmitted end, t8 timing spec can be
negligible.
Step5 Reset
4. Optical Specification
Optical characteristics are determined after the open cell unit and light source has been ‘ON’ and stable for
approximately 45 minutes in a dark environment at 25°C. The values specified are at an approximate distance
50cm from the LCD surface at a viewing angle of φ and θ equal to 0°.
Fig.1 presents additional information concerning the measurement equipment and method.
SR3 or equivalent
Values
Parameter Symbol Condition Unit Notes
Min. Typ. Max
Contrast Ratio CR -- 5000 -- 1, 2
White Variation δWHITE(9P) -- -- 1.33 1, 3
With AUO Module
Response Time (G to G) Tγ -- 6.5 -- ms 4
Center Transmittance T% 5.2 % 1, 7
Color Chromaticity 5
Red RX 0.659
RY 0.324
Green GX 0.268
With CS-1000T
GY 0.594
Standard light source “C” Typ.-0.03 Typ.+0.03
Blue BX 0.139
BY 0.090
White WX 0.292
WY 0.332
Viewing Angle 1, 6
x axis, right(φ=0°) θr -- 89 -- degree
x axis, left(φ=180°) θl With AUO Module -- 89 -- degree
y axis, up(φ=90°) θu -- 89 -- degree
y axis, down (φ=270°) θd -- 89 -- degree
H/2 1 2 3
4 5 6 H
7 8
H/6
V/6 V/2
4. Response time Tγ is the average time required for display transition by switching the input signal for five
luminance ratio (0%,25%,50%,75%,100% brightness matrix) and is based on Fv=60Hz to optimize.
Measured Target
Response Time 0% 25% 50% 75% 100%
0% 0% to 25% 0% to 50% 0% to 75% 0% to 100%
25% 25% to 0% 25% to 50% 25% to 75% 25% to 100%
Start 50% 50% to 0% 50% to 25% 50% to 75% 50% to 100%
75% 75% to 0% 75% to 25% 75% to 50% 75% to 100%
100% 100% to 0% 100% to 25% 100% to 50% 100% to 75%
The response time is defined as the following figure and shall be measured by switching the input signal for
“any level of gray(bright) “ and “any level of gray(dark)”.
5. Light source here is the standard light source “C” which is defined by CIE and driving voltages are based on
suitable gamma voltages. The calculating method is as following :
A. Measure the “Module” and “BLU” optical spectrums (W, R, G, B).
B. Calculate cell spectrum from “Module” and “BLU” spectrums.
C. Calculate color chromaticity by using cell spectrum and the spectrum of standard light source “C”.
6. Viewing angle is the angle at which the contrast ratio is greater than 10. The angles are determined for the
horizontal or x axis and the vertical or y axis with respect to the z axis which is normal to the LCD surface. For
more information see FIG4.
5. Mechanical Characteristics
6. Packing
Open cell shipping label (35*7mm)
1. S/N Number
2. AUO internal use
3. Manufactured week
4. Model name
Carton Label:
T390HVN04.0
91.39XXX.XXX
XXXXX–XXXXX–XXXXX
Packing Process:
EPE Spacer
Open Cell
Hybrid Box
11 Pcs/Box
Pallet Dimension:980*740*132 mm
after stack 8 boxes/Pallet, then put EPP top cover on it.
Specification
Item Packing Remark
Qty. Dimension Weight (kg)
1 Packing BOX 11pcs/box 970(L)*720(W)*137(H) 18.5 EPP Hybrid box
2 Pallet 1 980(L)*740(W)*132(H) 12.5 Wood pallet
3 Boxes per Pallet 8 boxes/pallet
4 SKD per Pallet 88 pcs/pallet
Pallet after packing N/A 980(L)mm*740 (W)mm*1178(H)mm 166
Stretch film
Corner angle
Pallet
7. Precautions
Please pay attention to the followings when you use this TFT LCD Open Cell unit and strongly recommended
to contact AUO if module process advice is required.
7.5 Storage
When storing open cell units as spares for a long time, the following precautions are necessary.
(1) Store them in a dark place. Do not expose the open cell unit to sunlight or fluorescent light. Keep the
temperature between 5 ℃ and 35℃ at normal humidity.
(2) The polarizer surface should not come in contact with any other object. It is recommended that they be
stored in the container in which they were shipped.