DATE/TIME

OPERATOR NAME

PETROSEAL ENGINEERING PUMP TAG NO

Mechanical Seal Failure Operator Info

Pump Duty: ___________________________________________________________________

Equipment Observations: (check box and fill where required)

Seal Temperature: Low (< 10℃) Normal (10-80℃) High (>80℃)

Pump Temperature: Low (< 10℃) Normal (10-80℃) High (>80℃)

Vibration Level: Normal High

Cavitation: Yes No

Abnormal sound: Yes No

Seal Flush Working: Yes No

Cooler Fitted: Yes No

Temp. Difference (℃): Coolant:_________ Product:__________

Quench: On Off Pressure: _________

Seal Leakage: Drips :____/min Stream Spray

When Pump: Running Stationary

Which Side: Drive End Non-Drive End Both

Leak path: Between Gland and Pump Face

Gland Drain Port

Between Sleeve & Shaft

Gland pipe works

Elsewhere (specify): _______________________________

API Piping Plan: Pressurized (specify):________________________

Unpressurized (specify):______________________

Reservoir level: Low Normal High

Reservoir pressure: Low Normal High

Reservoir when filled: Rise Fall Rapidly Slowly

Fill frequency: ________ times per: days weeks

Vent port: Opened Closed

*Please return this form to Petroseal Engineering Sdn Bhd field representative.
Guidelines for mechanical seal failure info checklist

1. Please fill up the date, time operator’s name and pump identification tag.

2. Specify the duty of the equipment and indicate any abnormal operating condition.

3. Indicate the seal operating temperature was normal or not and compare with pump’s

measurement.

4. Indicate whether vibration level is beyond normal.

5. Is cavitation or abnormal sound (example: squeaking from dry running) present?

6. Compare inlet and outlet temperature of seal cooler if fitted.

7. Specify the quench medium used (steam/wet) and pressure if used.

8. Specify the seal leakage pattern. Drips per minutes or spray/stream.

9. Is the leakage occurring during equipment stationary/running?

10. Specify which side of seal is leaking if it is double ended.

11. Specify where the leakage appears to come from.

12. Specify API piping plan (Plan 11/ 52/ etc.) of seal and if it should be pressurized or not.

13. Indicate the seal pot level is normal or not and the frequency of refilling.

14. Indicate whether vent port was opened or closed/plugged for unpressurized system.

Contact Petroseal Engineering Sdn Bhd’s personnel for any further clarification needed.

(HEADQUARTERS)
PETROSEAL ENGINEERING SDN BHD,
36, JLN. PUTRA A/2 BANDAR PUTRA,
24000 KEMAMAN, TERENGGANU.

+609 8686825 (TEL)


+609 8686979 (FAX)

*Please return this form to Petroseal Engineering Sdn Bhd field representative.

Вам также может понравиться