Академический Документы
Профессиональный Документы
Культура Документы
1 2
4 5
Components
– Electrical:
• Bushings up to 1,200 kVAC and 1,100 kVDC
• Tap-changers, on-load and de-energized
• Distribution and power transformer components
• Measurement and safety devices
• Smart eDevices
– Mechanical:
• Oil Treatment equipment
Insulation
– Pressboard and specialty paper manufacturing
– Winding and active part insulation kits
– Fiber composite laminates and components
– Flexible laminates
– Polymeric insulators
SE, Piteå
SE, Ludvika
SE, Figeholm RU, Moscow
PL, Lodz,
DE, Roigheim
CH, Zürich
IT, Montebello TR, Istanbul CN, Chongqing
USA, Alamo CN, Hefei,
Bushings
Tap-changers
Measurement and safety devices
Smart monitoring
Insulation
ABB has been the supplier of choice for over 100 years by meeting the diverse
needs of a global market, with global footprint.
We are closest to you, offering advanced technology solutions, tailored to individual
requirements, ensuring users can rely on the best service and highest possible
safety and reliability performance.
Our offering includes:
Oil impregnated with Resin impregnated (dry) with Conventional non-condenser Epoxy resin bushings
porcelain insulators porcelain / silicone insulators porcelain / silicone bushings 1–42 kV
24–1200 kV 24–800 kV 1–52 kV
June 4, 2018 Slide 10 Conformance: IEC, IEEE & Regional Standard Variant
Bushings
1100 kV HVDC bushings
Designed, manufactured and tested according to: Design, manufacturing and test according to:
– Switching impulse 2100 kV – Switching impulse 2100 kV
– Lightning impulse 2300 kV – Lightning impulse 2300 kV
– DC withstand 1920 kV – DC withstand 1683 kV
– DC polarity reversal 1480 kV – DC polarity reversal 1400 kV
– AC applied 1386 kV – AC applied 1190 kV
– Rated current 4137 A – Rated current 5078 A
Bushings
Tap-changers
Measurement and safety devices
Smart monitoring
Insulation
Tap-changers are essential parts of transformers, ensuring they operate reliably and safely.
ABB offers a large variation of tap-changers types for both high voltage and low voltage
regulation, in in-tank and on-tank solutions.
Full product portfolio offering for on-load Off-load tap-changers IEC and IEEE standards:
tap-changers IEC and IEEE / ANSI standards: – 125–1050 kV (BIL)
– In-tank resistance types – 250–1600 Amp.
– On-tank reactance types
ABB’s Elmek DeTC ABB’s Comem DeTC (High Voltage) ABB’s Comem DeTC (Medium Voltage)
Sel. III/F
Sel. IV/F
Sel. III/F
Sel. III/F
Sel. C
On-tank In-tank
Product name UZF UZE UBB UCG short UCG UCG UCL UCD UCC
Max voltage¹ (kV) 145 145 72.5 245 245 245 245 245 245
Max BIL (kV) 650 650 350 1050 1050 1050 1050 1050 1050
Max current (A)4 600 600 500 600 600 600 900 1000 1600
Reactance Resistive
Selec. III/F
Vacuum portfolio
Selec. III/F
On-tank In-tank
Sel. C
Product name VRLTC VUBB3 VUCG short VUCG VUCG VUCL2
Max voltage¹ (kV) 34,5 72.5 245 245 245 245
Max BIL (kV) 200 380 1050 1050 1050 1050
Max current (A)4 1500 600 800 800 800* 1300
Less maintenance
Personal safety
Environmentally friendly
Bushings
Tap-changers
Measurement and safety devices
Smart monitoring
Insulation
To secure reliable and safe service conditions of the transformer, ABB provides a
complete range of measurement and safety devices including the new generation
of smart devices and cost-effective, overall solutions, which allow to monitor the
health of your apparatus and improve equipment safety, reliability and efficiency,
while minimizing the environmental impact at the same time.
More than 50 years of experience in producing measurement and safety devices for
transformers
A comprehensive product portfolio for distribution and power transformers
Wide range of smart devices for transformer smart monitoring
State-of-the-art technology
Global coverage
After sales and customer support
June 4, 2018 Slide 22 Conformance: IEC, IEEE & Regional Standard Variant
GPG I&C
Components for power transformers
Measurement and safety devices - conventional and with analog and digital output
June 4, 2018 Slide 23 Conformance: IEC, IEEE & Regional Standard Variant
Agenda
Bushings
Tap-changers
Components
Smart monitoring
Insulation
Monitoring
Tablets &
smartphones
Oil level
Bushings
Tap-changers
Measurement and safety devices
Smart monitoring
Insulation
The quality and reliability of the insulation used, results in extending life expectancy of transformer, savings
in material costs and reducing losses.
Kraft & Press paper in sheets and rolls Figeholm Elboard HD / LD Pressboard Angle Rings, Caps and Snout
Crepe paper – Tubes / Pads Figeholm Elboard Lamination HDLC / HDLP Static Rings, Cylinders
Strips, Spacers, U Channels
Coated “Diamond Dotted Paper” (DDP) Raman Sigmacom 3.1 HD Pressboard
L-profiles for leads and cleats
Raman Sigmacom Laminated HDLC
Duct spacing, Crepe tubes
Raman Lam4Wood Laminated HDLC for Distribution transformers
Clack Bands
Corrugated Boards
Transformer manufacturers to increase their Reduction of the production costs Lead exit in tank and turret – 1200kV AC
efficiency when developing windings Flexible – up to 5 possible turns/angles
Increase in production capacities
The aim of the winding kit is to have the up to ±90 degrees possible
Reduced freight costs
insulation parts at hand or pre-mounted when No molded parts for barrier tubes needed
manufacturing and assembling windings Reduction of storage costs for insulation Layout driven Pro E models reduce
material
Design time for Trafo OEM can be used
Improving space utilization for 3D-field calculation
PD free design up to 1200 kV
Calendared board
Crepe tubes
Duct spacers
Flexible laminates
Generators, Motors & HV Apparatus Tension Rods, Power Loops For Breakers, Bushings & cable Terminations
– Low shrinkage and high strength – Load tap changer diverter and selector – Breakers live and dead tank
housings, capacitor tension rods up to 500 kV, HVDC bushings, Kabeldon
– Low power factor and partial discharge & Alcatel
http://new.abb.com/products/transfo
rmers/transformer-components
End-customer
Red Eléctrica de España
OEM
ABB Córdoba Transformers
Transformer
200 MVA single-phase transformer filled with natural
ester oil
Bushings – ABB Micafil